Skip to main content
Netherlands Heart Journal logoLink to Netherlands Heart Journal
. 2010 Oct;18(10):486–492. doi: 10.1007/BF03091820

One-year clinical follow-up of a registry evaluating a percutaneous revascularisation strategy combining a pre-specified simple selection process with the use of a new thin-strut bare cobalt-chromium stent

PR Stella 1, G Pavlakis 1, P Agostoni 1, HM Nathoe 1, S Hoseyni Guyomi 1, BJ Hamer 1, TX Wildbergh 1, PA Doevendans 1, E Van Belle 1
PMCID: PMC2954301  PMID: 20978593

Abstract

Objectives. To evaluate clinical events in a specifically selected cohort of patients with obstructive coronary artery disease (CAD), using a new generation thin-strut bare cobalt-chromium coronary stent.

Methods. Patients with single- or multi-vessel, stable or unstable CAD eligible for percutaneous implantation of at least one bare cobalt-chromium stent were evaluated in a single-centre registry. Prospective pre-specified criteria for bare cobalt-chromium stent implantation in our centre were: any acute ST-elevation myocardial infarction (MI), otherwise 1) de novo coronary lesion, and 2) lesion length <20 mm, and 3) reference vessel diameter >2.6 mm, and 4) no diabetes, unless reference vessel diameter >3.5 mm. Endpoints, retrospectively collected, were death, MI and clinically driven target-lesion revascularisation (TLR) and target-vessel revascularisation (TVR) after 12 months.

Results. Between September 2005 and June 2007, 712 patients (48.7% one-vessel, 29.9% two-vessel, 20% three-vessel and 1.4% left main disease; 7.9% diabetics) were treated with 800 bare cobalt-chromium stents, for stable angina (40.9%), unstable angina (20.9%) or acute ST-elevation MI (38.2%). The procedural success rate was 99.3%. Peri-procedural MI rate was 2.2% in the semi-elective group. At 12 months there were 17 deaths (2.4%), of which nine non-cardiac, 20 (2.8%) MI, 19 (2.7%) TLR and 29 (4.1%) TVR. Early and late definite stent thrombosis occurred in four (0.6%) and three (0.4%) patients, respectively.

Conclusion. A strategy aimed at minimising drug-eluting stent use and combining a pre-specified simple selection process with the use of a new thin-strut bare cobalt-chromium stent is safe and effective at one-year clinical follow-up. (Neth Heart J 2010;18:486–92.)

Keywords: Bare Metal Stent, Coronary Artery Disease, Stable Angina, Non Stable Angina, STEMI


Percutaneous coronary interventions (PCI) are a valuable addition to treatment regimens in modern cardiology.1-3 The use of intracoronary metallic stents has improved results over balloon dilatation alone and has become standard care for patients undergoing PCI.4 However, in-stent restenosis, leading to recurrence of symptoms, has been the major drawback of bare metal stents (BMS).5 Drug-eluting stents (DES) were introduced in an attempt to overcome this problem and, due to the improved effectiveness in preventing restenosis, DES implantation has rapidly grown to up to 80% of cases in some countries.6 However, recently there have been concerns about their long-term safety,7 due to an increase in late stent thrombosis, possibly linked to delayed endothelialisation of the stent struts. Delayed endothelial cell growth is due to a non-selective inhibitory action of the drug on targeting both smooth muscle cell proliferation and endothelial cell regeneration.8 Moreover, DES definitely increases the cost of PCI when compared with BMS and debate is ongoing over the long-term cost-effectiveness of these devices.9

The beneficial clinical data on DES are mainly derived from trials comparing DES with first-generation thick-strut stainless steel BMS. However, outcomes can be different between stents depending on material and design.10-13 Stents with thinner struts have shown less restenosis and less repeated interventions.14,15 This effect may be due to more rapid re-endothelialisation after deployment of thinner-strut stents, reducing vascular injury and inflammation.14-16 With the progressive development of BMS manufacturing, the use of cobalt-chromium alloy has appeared promising. This alloy has shown good biocompatibility and appeared to limit the adverse proliferative response seen with other alloys.9-11 In addition, cobalt-chromium compared with stainless steel allows reduction in strut thickness with increased flexibility, conserving both radial strength and deliverability.17

Our aim was to evaluate the clinical outcome of a cohort of patients undergoing PCI, in whom the decision to use a new generation thin-strut bare cobalt-chromium coronary stent was pre-specified according to ‘non-DES’ criteria.

Methods

This was a single-centre registry, based on a prospective pre-specified simple selection process used to discriminate between BMS or DES implantation, and retrospective data collection. The centre consensus agreement18 limited the use of BMS to patients with the following pre-specified criteria: any acute ST-elevation myocardial infarction (MI), otherwise 1) de novo coronary lesion, and 2) lesion length <20 mm, and 3) reference vessel diameter >2.6 mm, and 4) no diabetes, unless reference vessel diameter >3.5 mm. Exceptions, with use of BMS also out of these criteria, occurred in case of predicted or suspected inability of patients to comply with long-term (one year) double antiplatelet therapy or in case of expected survival <6 months.

In this registry the Skylor thin-strut bare cobalt-chromium stent (Invatec S.p.A., Roncadelle [Brescia], Italy) was used as BMS. As the stent was already CE approved, marketed and commercially available at the beginning of the study, no formal informed consent, apart from the one related to the procedure, was requested.

Procedures

All angioplasty procedures were performed according to routine practice. According to the daily routine, direct stenting and post-dilatation were allowed and left to the discretion of the operator. Patients who received different types of stents in the index vessel were excluded. All patients were treated with standard optimal medical therapy, consisting of aspirin (at least 80 mg/day lifetime) and clopidogrel (75 mg/day after loading dose of 300 or 600 mg for at least one month up to one year in case of acute coronary syndromes). Use of β-blockers, ACE inhibitors, calcium antagonists, statins and nitrates were administered if clinically indicated.

Stent characteristics

The Skylor stent is a thin-strut bare cobalt-chromium stent with a multiple mono-type closed cell design. Strut thickness differs according to the diameter of the stent implanted: 70 μm for small vessel stents (2.00, 2.25 or 2.50 mm in diameter), 80 μm for medium vessel stents (2.75, 3.00 and 3.50 mm in diameter) and 95 μm for large vessel stents (4.00, 4.50 and 5.00 mm in diameter).19

Data collection

All PCI performed were recorded in a local data management system. Data input included medical history, risk factors, medication use, peri-procedural data and clinical follow-up. For this analysis all patients who underwent PCI involving at least one Skylor stent between September 2005 and June 2007 were included. Active follow-up by phone call following a pre-specified questionnaire is routinely performed in our institute for all patients treated with PCI at one and 12 months after the index procedure.

Endpoint definitions

If an event occurred, careful review of the in-hospital data or requirement of data from other hospitals were performed in order to classify the event. All deaths were considered cardiac unless a clear non-cardiac cause could be established. Specifically, any unexpected or unwitnessed death was considered of cardiac origin. Myocardial infarction was defined as anginal symptoms associated with creatine kinase levels >3 times the upper limit of normal and concurrent elevation of creatine kinase-MB above the upper limit of normal (according to local reference values). All reported repeated interventions in the stented segment (including the stent and the 5 mm proximal and distal to the stent) were classified as target lesion revascularisation (TLR). Repeated interventions in the same vessel were reported as target vessel revascularisation (TVR). Major adverse cardiac events (MACE) were defined as a combined endpoint of death, MI (including peri-procedural MI) and TVR. Stent thrombosis was defined according to the Academic Research Consortium criteria.20

Statistical analysis

Continuous data are reported as means and standard deviations. Dichotomous data are reported as numbers (percentages). Due to the observational, non-randomised nature of this study, only descriptive statistics are reported. For every endpoint evaluated, 95% confidence intervals (CI) of the incidence rate were calculated, using dedicated software (Confidence Interval Analysis, Version 2.0.0, available at: http://www.medschool.soton.ac.uk/cia/main.htm, access: 26 February 2009).

Results

Baseline characteristics and in-hospital clinical outcomes

A total of 712 consecutive patients treated with PCI involving deployment of at least one Skylor stent were included. Baseline patient characteristics are shown in table 1. In total 800 Skylor stents were implanted. Procedural data are shown in table 2. One Skylor stent was implanted in 603 (84.6%) of the cases and two stents in 85 (11.9%). In five PCIs, four Skylor stents were used, and in one PCI, seven Skylor stents were implanted (these six procedures concerned technically challenging chronic total occlusions). The procedural success rate was 99.3% (95% CI 98.1 to 99.9%): in three PCIs the stent could not be delivered at the lesion site; additionally one PCI in a saphenous venous graft was complicated by perforation of the vessel treated, which was successfully managed with deployment of a covered stent; a second PCI was complicated by catheter-induced (type E) left main dissection, successfully treated with uneventful urgent coronary artery bypass surgery, which was also the sole TLR in-hospital. There were four in-hospital deaths (0.6% [0.1 to 1.4%]). Three patients died in the catheterisation laboratory, all presenting with an acute MI complicated by cardiogenic shock and referred while intubated and under inotropic support. Another patient underwent successful primary PCI for acute anteroseptal MI and, because of haemodynamic instability, he was transferred to the coronary care unit, were he died two days later because of ventricular tachyarrhythmia (probably due to early stent thrombosis). There were ten peri-procedural MIs (2.2% [1.2 to 4.1%]) in the semi-elective group (440 patients, 291 stable and 149 unstable).

Table 1.

Baseline patient characteristics.

Patients (n=712)
Age (years) 64±13
Male gender 530 (74.4)
Risk factors
- Diabetes 56 (7.9)
- Hypertension 238 (33.4)
- Hypercholesterolaemia 257 (36.1)
- Current smoking 156 (21.9)
- Family history 247 (34.7)
- Previous myocardial infarction 154 (21.6)
- Previous PCI procedure 106 (14.9)
- Previous coronary bypass surgery 51 (7.2)
Previous cerebrovascular accident 36 (5.1)
Baseline angina status
- Stable 291 (40.9)
- Acute coronary syndrome 149 (20.9)
- Acute ST-elevation myocardial infarction 272 (38.2)
Extent of disease
- One vessel 347 (48.7)
- Two vessels 213 (29.9)
- Three vessels 142 (20.0)
- Left main 10 (1.4)
Left ventricular function
- Poor 21 (3.0)
- Moderate 213 (29.9)
- Normal 478 (67.1)

Values are presented as numbers (%) or mean ± SD.

Table 2.

Procedural data.

Procedures (n=712)
Lesions (n=785)
Procedures with 1 Skylor stent 603 (84.6)
Procedures with 2 Skylor stents 85 (11.9)
Procedures with >2 Skylor stents 8 (1.2)
Average stent length (mm) 15.5±6.2
Average stent diameter (mm) 3.1±0.3
Procedural success 707 (99.3 )
Type of PCI
- Single vessel 639 (89.7)
- Multi-vessel 73 (10.3)
Index vessel
- Left anterior descending artery 334 (42.5)
- Right coronary artery 278 (35.4)
- Circumflex artery 148 (18.9)
- Left main coronary artery 10 (1.3)
- Bypass graft 15 (1.9)
Lesion type (ACC/AHA classification)
- A 120 (15.3)
- B1 336 (42.8)
- B2 201 (25.6)
- C 128 (16.3)

Values are presented as numbers (%) or mean ± SD. PCI=percutaneous coronary intervention.

Thirty-day clinical outcomes

One-month clinical events are shown in table 3. There were five repeated PCI procedures between hospital discharge and one month, one of which occurred because of TLR caused by dissection which was missed at the index procedure. The remaining four procedures (0.6%) were due to early stent thrombosis, all causing an acute MI.

Table 3.

Follow-up data.

Patients (n=712)
In-hospital adverse events
- Death 4 (0.6)
- Peri-procedural MI (in semi-elective group) 10/440 (2.2)
- Cerebrovascular accident 1 (0.1)
- Target lesion revascularisation 1 (0.1)
- Access site complications 8 (1.1)
Cumulative 30-day adverse events
- Death 4 (0.6)
- Myocardial infarction 14 (2.0)
- Cerebrovascular accident 1 (0.1)
- Target lesion revascularisation 6 (0.8)
- Target vessel revascularisation 6 (0.8)
- Definite early stent thrombosis 4 (0.6)
- Probable early stent thrombosis 1 (0.1)
Cumulative 12-month adverse events
- Death 17 (2.4)
- Myocardial infarction 20 (2.8)
- Cerebrovascular accident 1 (0.1)
- Target lesion revascularisation 19 (2.6)
- Target vessel revascularisation 29 (4.1)
- Major adverse cardiac events 59 (8.3)
- Definite early and late stent thrombosis 7 (1.0)
- Probable early and late stent thrombosis 4 (0.6)
- Possible stent thrombosis 4 (0.6)

Values are presented as numbers (%).

Twelve-month clinical outcomes

One-year clinical events are presented in table 3. There were three patients lost to follow-up at 12 months (0.4%). The overall mortality rate was 2.4% (95% CI 1.3 to 4.2%) with four additional cardiac deaths (0.6%, all possible stent thromboses) between one and 12 months of follow-up and nine (1.3%) noncardiac deaths (all due to tumours). The total rate of MI was 2.8% (2.1 to 4.5%), with six additional MIs (all considered late stent thromboses, three definite and three probable) between one and 12 months. The rate of TLR was 2.7% (1.8 to 4.4%) including three PCIs performed for definite late stent thrombosis and ten revascularisation procedures performed for recurrent ischaemia. The rate of TVR was 4.1% (2.8 to 6.1%). Overall, out of the 29 TVR procedures, 28 were again percutaneous, while one was surgical. The overall rate of definite and probable stent thrombosis was 1.5% (0.9 to 3.1%), including five early cases and six late cases. Overall MACE rate was 8.3% (6.7 to 11%).

Discussion

Drug-eluting stents are more effective than BMS in reducing restenosis and preventing repeated revascularisation procedures,6 mainly by limiting intimal hyperplasia,21 with similar early rates of death or nonfatal MI. However, concern is growing that delayed endothelialisation, incomplete neointimal healing, late acquired stent malapposition or hypersensitivity reactions after the implantation of DES may lead to increased rates of late adverse events, such as cardiac death and MI, due to the occurrence of stent thrombosis.7,8

In order to minimise late thrombotic events with the use of DES, an extended dual antiplatelet regiment is recommended for at least 12 months. However, the bleeding risks associated with prolonged dual antiplatelet therapy22,23 and the increased costs for the healthcare system9 should be taken into account. Moreover, a substantial proportion of patients have contraindications to prolonged antiplatelet therapy, or are already taking oral anticoagulants or cannot afford the increased cost of clopidogrel, in countries where this drug is not reimbursed. Such a prolonged dual antiplatelet therapy may be specifically valuable in patients who are at increased risk for stent thrombosis after DES implantation, such as those with diabetes, renal failure, long lesions and bifurcation disease.24,25 Patients with these characteristics generally also have an increased risk for in-stent restenosis thus potentially getting the greatest benefit from DES in terms of reduction of restenosis. However, independently from clopidogrel use, in randomised trials as well as in large registries, very late stent thrombosis (occurring more than one year after stent implantation) is more common after DES than BMS implantation.7,26 Thus, in ‘real-world’ patients the selective use of BMS can be adequately justified, when safety is the first issue. Nonetheless, the overall efficacy of BMS is sub-optimal as compared with DES.

The detection of selected subgroups of patients and lesions where BMS can perform well with a low rate of repeated revascularisations appears a reasonable alternative. Some data from registries and post-hoc analyses of randomised controlled trials suggest that BMS favourably compare with DES in lesions located in large coronary vessels (defined as vessels in which a stent >3.0 mm in diameter was implanted).27-29 Angiographic superiority of DES remains solid, even in comparison with the newer generation BMS. In a recent randomised trial, angiographic parameters of restenosis were significantly lower in the DES group versus a thin-strut cobalt-chromium stent (late loss: 0.18±0.40 versus 0.58±0.51 mm). Though the angiographic performance of BMS in this trial was good. Furthermore, no statistically significant clinical differences between the two groups were apparent at 12 months (the trial, however, was definitely underpowered for this endpoint): freedom from target vessel failure at 12 months was 72% for DES patients and 68% for BMS patients.30

Other categories where conflicting results with DES still exist are patients with acute ST-elevation MI and lesions in saphenous vein grafts. Regarding acute ST-elevation MI, recent registries have shown no clear superiority of DES over BMS in terms of long-term repeated revascularisations,31 raising even doubts on a possible increase in long-term mortality after DES placement.32 However, in a recent meta-analysis of randomised trials, the use of DES significantly reduced the short-term rate of TVR without impact on mortality.33 Regarding vein graft stenting, the data comparing DES with BMS are scarce and even more conflicting. In a secondary post-hoc analysis of a randomised trial the use of DES was found to be associated with increased long-term mortality as compared with BMS.34 Nevertheless, these data need further verification.

In light of all these issues, it is obvious that in the modern era of interventional cardiology there is a place for the newest generation of BMS. In the aforementioned subgroups of patients in whom the use of DES does not seem completely beneficial or is based on contradictory trials, as well as in patients with relative or absolute contraindication to prolonged antiplatelet therapy, the new generation of thin-strut cobalt-chromium BMS fills the gap with very good efficacy. Currently, according to our present policy, providing that the patients do not have an acute ST-elevation MI and are able to comply with double oral antiplatelet therapy for one year, DES should be reserved for the following indications: 1) in-stent restenosis, 2) diabetes mellitus with reference vessel diameter <3.5 mm, 3) small vessel disease (reference vessel diameter <2.6 mm), and 4) lesions with length >20 mm. Our registry confirms that this policy, based on a pre-specified simple selection process to discriminate between BMS or DES implantation, provides very good results with a new generation BMS. This new generation class of cobalt chromium thin-strut bare metal stents has been adequately tested in several registries and in a variety of clinical settings. In each of these studies, newer generation BMS seem a safe and effective treatment modality (table 4).17,35-38 Besides these promising results, there are also some technical advantages related to these BMS. Since cobalt chromium is about 75% stronger than stainless steel, it allows the stent to have thinner struts, thus increasing pushability, flexibility, deliverability and trackability (potentially making the PCI procedure simpler and faster), while maintaining radial strength and radiological visibility.

Table 4.

Literature on bare cobalt-chromium coronary stents.

Stent type Follow-up duration (months) Patients (n) Procedural success (%) TLR (%) TVR (%) MACE (%) TVF (%) Stent thrombosis (%)
MultiLink Vision17 6 268 99.0 4.3 5.1 6.2 6.7 -
Medtronic Driver35 9 298 98.3 7.0 8.1 8.4 8.1 0
Medtronic Driver36 6 202 98.0 9.4 - 12.4 - 0.5
Arthos Pico37 12 203 98.0 - 8.9 15.0 - 2.0
Invatec Skylor38 9 150 97.0 6.0 - 8.0 12.4 1.4

MACE=major adverse cardiac event, TLR=target lesion revascularisation, TVF=target vessel failure, TVR=target vessel revascularisation. Each endpoint was defined according to the specific study.

A final proof of the substantial similarity in effectiveness and superiority in safety of these new generation BMS as compared with DES will come from the ongoing BASKET PROVE randomised trial, performed specifically in lesions in large coronary vessels and planning to enrol more than 2000 patients.39

Limitations

We acknowledge that this is a single centre registry. Lack of randomisation is the major limitation, together with retrospective data collection. Furthermore, patients did not undergo systematic angiographic follow-up; they received a control angiogram only if clinically indicated. Thus there is no angiographic evaluation of the performance of the stent. On the other hand, it is well known that routine angiographic follow-up tends to inflate the rate of repeated revascularisation procedures due to the so-called ‘oculo-stenotic’ reflex.40

References

  • 1.Keeley EC, Boura JA, Grines CL. Primary angioplasty versus intravenous thrombolytic therapy for acute myocardial infarction: a quantitative review of 23 randomised trials. Lancet. 2003;361:13-20. [DOI] [PubMed] [Google Scholar]
  • 2.Schomig A, Mehilli J, de Waha A, Seyfarth M, Pache J, Kastrati A. A meta-analysis of 17 randomized trials of percutaneous coronary intervention-based strategy in patients with stable coronary artery disease. J Am Coll Cardiol. 2008;52:894-904. [DOI] [PubMed] [Google Scholar]
  • 3.Biondi-Zoccai G, Abbate A, Agostoni P, Testa L, Burzotta F, Lotrionte et al. Long-term benefits of an early invasive management in acute coronary syndromes depend on intra-coronary stenting and aggressive anti-platelet treatment: a meta-regression. Am Heart J. 2005;149:504-11. [DOI] [PubMed] [Google Scholar]
  • 4.Brophy JM, Belisle P, Joseph L. Evidence for use of coronary stents: a hierarchical ayesian meta-analysis. Ann Intern Med. 2003;138:777-86. [DOI] [PubMed] [Google Scholar]
  • 5.Daemen J, Boersma E, Flather M, Booth J, Stables R, Rodriguez A, et al. Long-term safety and efficacy of percutaneous coronary intervention with stenting and coronary artery bypass surgery for multivessel coronary artery disease: a meta-analysis with 5-year patient level data from the ARTS, ERACI-II, MASS-II, and SoS trials. Circulation. 2008;118:1146-54. [DOI] [PubMed] [Google Scholar]
  • 6.Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schömig A, et al. Outcomes associated with drug-eluting and bare metal stents: a collaborative network meta-analysis. Lancet. 2007;370:937-48. [DOI] [PubMed] [Google Scholar]
  • 7.Bavry AA, Kumbhani DJ, Helton TJ, Borek PP, Mood GR, Bhatt DL. Late thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials. Am J Med. 2006;119:1056-61. [DOI] [PubMed] [Google Scholar]
  • 8.Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol. 2006;48:193-202. [DOI] [PubMed] [Google Scholar]
  • 9.Filion KB, Roy AM, Baboushkin T, Rinfret S, Eisenberg MJ. Cost-effectiveness of drug-eluting stents including the economic impact of late stent thrombosis. Am J Cardiol. 2009;103:345-9. [DOI] [PubMed] [Google Scholar]
  • 10.Sangiorgi G, Melzi G, Agostoni P, Cola C, Clementi F, Romitelli P, et al. Engineering aspects of stents design and their translation into clinical practice. Ann Ist Super Sanita. 2007;43:89-100. [PubMed] [Google Scholar]
  • 11.Hoffmann R, Mintz GS, Haager PK, Bozoglu T, Grube E, Gross M, et al. Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound. Am J Cardiol. 2002;89:1360-4. [DOI] [PubMed] [Google Scholar]
  • 12.Kastrati A, Dirschinger J, Boekstegers P, Elezi S, Schühlen H, Pache J, et al. Influence of stent design on 1-year outcome after coronary stent placement: a randomized comparison of five stent types in 1,147 unselected patients. Catheter Cardiovasc Interv. 2000;50:290-7. [DOI] [PubMed] [Google Scholar]
  • 13.Briguori C, Sarais C, Pagnotta P, Liistro F, Montorfano M, Chieffo A, et al. In-stent restenosis in small coronary arteries: impact of strut thickness. J Am Coll Cardiol. 2002;40:403-9. [DOI] [PubMed] [Google Scholar]
  • 14.Kastrati A, Mehilli J, .Dirschinger J, Dotzer F, Schunhlen H, Neumann FJ, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR STEREO) trial. Circulation. 2001;103:2816-21. [DOI] [PubMed] [Google Scholar]
  • 15.Pache J, Kastrati A, Mehilli J, Schunhlen H, Dotzer F, Hausleiter J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. J Am Coll Cardiol. 2003;41:1283-8. [DOI] [PubMed] [Google Scholar]
  • 16.Rittersma SZ, de Winter RJ, Koch KT, Bax M, Schotborgh CE, Mulder KJ, et al. Impact of strut thickness on late luminal loss after coronary artery stent placement. Am J Cardiol. 2004;93:477-80. [DOI] [PubMed] [Google Scholar]
  • 17.Kereiakes DJ, Cox DA, Hermiller JB, Midei MG, Bachinsky WB, Nukta ED, et al; Guidant Multi-Link Vision Stent Registry Investigators. Usefulness of a cobalt chromium coronary stent alloy. Am J Cardiol. 2003;92:463-6. [DOI] [PubMed] [Google Scholar]
  • 18.de Man FH, Stella PR, Nathoe H, Kirkels H, Hamer B, Meijburg HW, et al. Stent thrombosis in real-world patients: a comparison of drug-eluting with bare metal stents. Neth Heart J. 2007;15:382-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Product specifications Skylor stent system. Available at www.invatec.com/tool/home.php?s=0,1,55,56,98. Access: 5 February 2009. [Google Scholar]
  • 20.Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, Es GA, et al, on behalf of the Academic Research Consortium. Clinical end points in coronary stent trials: A case for standardized definitions. Circulation. 2007;115:2344-51. [DOI] [PubMed] [Google Scholar]
  • 21.Sousa JE, Costa MA, Abizaid A, Abizaid AS, Feres F, Pinto IM, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation. 2001;103:192-5. [DOI] [PubMed] [Google Scholar]
  • 22.Collet JP, Montalescot G, Blanchet B, Tanguy ML, Golmard JL, Choussat R, et al. Impact of prior use or recent withdrawal of oral antiplatelet agents on acute coronary syndromes. Circulation. 2004;100:2361-7. [DOI] [PubMed] [Google Scholar]
  • 23.Diner AC, Bogousslavsky J, Brass LM. Aspirin and clopidogrel compared with clopidogrel alone after recent ischemic stroke or transient ischemic attack in high-risk patients (MATCH): randomised, double-blind, placebo-controlled trial. Lancet. 2004;364:331-7. [DOI] [PubMed] [Google Scholar]
  • 24.Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA. 2005;293:2126-30. [DOI] [PubMed] [Google Scholar]
  • 25.Kuchulakanti PK, Chu WW, Torguson R, Ohlmann P, Rha SW, Clavijo LC, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus- and paclitaxel-eluting stents. Circulation. 2006;113:1108-13. [DOI] [PubMed] [Google Scholar]
  • 26.Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet. 2007;369:667-78. [DOI] [PubMed] [Google Scholar]
  • 27.Quizhpe AR, Feres F, de Ribamar Costa J Jr, Abizaid A, Maldonado G, Costa R, Abizaid A, Cano M, Moreira AC, Staico R, Mattos LA, Tanajura LF, Chaves A, Centemero M, Sousa AM, Sousa JE. Drug-eluting stents vs. bare metal stents for the treatment of large coronary vessels. Am Heart J. 2007;154:373-378. [DOI] [PubMed] [Google Scholar]
  • 28.Pfisterer M, Brunner-La Rocca HP, Rickenbacher P, Hunziker P, Mueller C, Nietlispach F, et al; BASKET. Long-term benefit-risk balance of drug-eluting vs. bare-metal stents in daily practice: does stent diameter matter? Three-year follow-up of BASKET. Eur Heart J. 2009;30:16-24. [DOI] [PubMed] [Google Scholar]
  • 29.Pache J, Dibra A, Mehilli J, Dirschinger J, Schömig A, Kastrati A. Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective, randomized trial. Eur Heart J. 2005;26:1262-8. [DOI] [PubMed] [Google Scholar]
  • 30.Ortolani P, Marzocchi A, Marrozzini C, Palmerini T, Saia F, Taglieri N, et al. Randomized comparative trial of a thin-strut bare metal cobalt-chromium stent versus a sirolimus-eluting stent for coronary revascularization. Catheter Cardiovasc Interv. 2007;69:790-8. [DOI] [PubMed] [Google Scholar]
  • 31.Daemen J, Tanimoto S, García-García HM, Kukreja N, van de Sande M, Sianos G, et al Comparison of three-year clinical outcome of sirolimus- and paclitaxel-eluting stents versus bare metal stents in patients with ST-segment elevation myocardial infarction (from the RESEARCH and T-SEARCH Registries). Am J Cardiol. 2007;99:1027-32. [DOI] [PubMed] [Google Scholar]
  • 32.Steg PG, Fox KA, Eagle KA, Furman M, Van de Werf F, Montalescot G, et al.; Global Registry of Acute Coronary Events (GRACE) Investigators. Mortality following placement of drug-eluting and bare-metal stents for ST-segment elevation acute myocardial infarction in the Global Registry of Acute Coronary Events. Eur Heart J. 2009;30:321-9. [DOI] [PubMed] [Google Scholar]
  • 33.Kastrati A, Dibra A, Spaulding C, Laarman GJ, Menichelli M, Valgimigli M, et al. Meta-analysis of randomized trials on drug-eluting stents vs. bare-metal stents in patients with acute myocardial infarction. Eur Heart. J 2007;28:2706-13. [DOI] [PubMed] [Google Scholar]
  • 34.Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Van den Branden F, et al.; DELAYED RRISC (Death and Events at Long-term follow-up AnalYsis: Extended Duration of the Reduction of Restenosis In Saphenous vein grafts with Cypher stent) Investigators. Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts: results from the randomized DELAYED RRISC Trial.J Am Coll Cardiol. 2007;50:261-7. [DOI] [PubMed] [Google Scholar]
  • 35.Sketch MH Jr, Ball M, Rutherford B, Popma JJ, Russell C, Kereiakes DJ; Driver investigators. Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system.Am J Cardiol. 2005;95:8-12. [DOI] [PubMed] [Google Scholar]
  • 36.Legrand V, Kelbaek H, Hauptmann KE, Glogar D, Rutsch W, Grollier G, et al.; CLASS Investigators. Clinical and angiographic analysis with a cobalt alloy coronary stent (driver) in stable and unstable angina pectoris.Am J Cardiol. 2006;97:349-52. [DOI] [PubMed] [Google Scholar]
  • 37.Strehblow C, Gyöngyösi M, Zenker G, Wallner H, Heigert M, Siostrzonek P, et al.. Small vessel stenting with cobalt-chromium stents (Arthos Pico) in a real world setting. Coron Artery Dis. 2007;18:305-11. [DOI] [PubMed] [Google Scholar]
  • 38.Burzotta F, Trani C, Todaro D, Mazzari MA, Porto I, De Vita MR, et al. Outcome of patients treated by a novel thin-strut cobalt-chromium stent in the drug-eluting stent era: Results of the SKICE (Skylor in real world practICE) registry. Cathet Cardiovasc Interv. 2009;73:457-65. [DOI] [PubMed] [Google Scholar]
  • 39.Pfisterer M, Bertel O, Bonetti PO, Brunner-La Rocca HP, Eberli FR, Erne P, et al.; BASKET-PROVE Investigators. Drug-eluting or bare-metal stents for large coronary vessel stenting? The BASKET-PROVE (PROspective Validation Examination) trial: study protocol and design. Am Heart J. 2008;155:609-14. [DOI] [PubMed] [Google Scholar]
  • 40.Kereiakes DJ, Kuntz RE, Mauri L, Krucoff MW. Surrogates, substudies, and real clinical end points in trials of drug-eluting stents. J Am Coll Cardiol. 2005;45:1206-12. [DOI] [PubMed] [Google Scholar]

Articles from Netherlands Heart Journal are provided here courtesy of Springer

RESOURCES