Skip to main content
Journal of the American Medical Informatics Association : JAMIA logoLink to Journal of the American Medical Informatics Association : JAMIA
letter
. 2010 Dec 18;18(1):104. doi: 10.1136/jamia.2010.008177

Performance of support-vector-machine-based classification on 15 systematic review topics evaluated with the WSS@95 measure

Aaron M Cohen
PMCID: PMC3005879  PMID: 21169622

In the July 2010 issue of JAMIA, Matwin et al published an article entitled ‘A new algorithm for reducing the workload of experts in performing systematic reviews.’1 Briefly, the work proposes a factorized variant of the complement Naïve Bayes classifier as an improvement, using weight engineering on the features (FCNB/WE). The prior work of Cohen et al in this area is cited, and the data set made public along with this prior work is used for the evaluation.2

The Matwin et al article compares the authors' proposed system against the early Cohen et al published voting perceptron (VP) classifier results, using the ‘work saved over sampling at 95% recall’ (WSS@95) measure proposed in that paper. However, the article notes that WSS@95 figures were not published in Cohen's later work based on the support vector machine (SVM) classifier,3 4 and states that these figures were not available for comparison.

Our team has not published the WSS@95 figures for the SVM classifier previously because our current investigations focus on using classification for a number of different use cases within the systematic review process. Each of these use cases, and potentially each review team and user, may prefer different recall-precision trade offs, and therefore different classification thresholds. Furthermore, this may be affected by the size of the literature base in a given review domain and/or the prevalence of articles meeting the inclusion criteria for that review. Therefore, we have chosen to use the area under the receiver-operating curve (AUC) as our measure of classifier accuracy across the range of possible operating points, instead of the single point measure WSS@95. We are currently conducting a study of systematic reviewer preferences for classification performance within these use cases to better understand how to optimize for these trade-offs.

Although not previously published, in fact, we did collect WSS@95 performance figures for the 15 systematic review topic data set used by Matwin et al. The system used is identical to that published in our prior work.4 These results were obtained using five repetitions of twofold crossvalidation, as in Matwin as well as our prior work, and are shown in table 1. As can be seen in the table, the performance of our previously published SVM-based system is generally superior to that of Matwin, outperforming the FCNB/WE system for 12 of 15 topics on WSS@95. On average, our previously published system increases WSS@95 by 0.073 over FCNB/WE. This represents a mean improvement of almost 22%.

Table 1.

WSS@95 Comparison of Cohen 20084 and Matwin 20101 Systems across 15 systematic review topics using 5×2 cross-validation

Topic Cohen 20084 support vector machine Matwin 20101 FNCB/WE Delta
ACE inhibitors 0.733 0.523 0.210
Attention deficit hyperactivity disorder 0.526 0.622 −0.096
Antihistamines 0.236 0.149 0.087
Atypical antipsychotics 0.170 0.206 −0.036
Beta blockers 0.465 0.367 0.098
Calcium-channel blockers 0.430 0.234 0.196
Estrogens 0.414 0.375 0.039
Nonsteroidal anti-inflammatory drugs 0.672 0.528 0.144
Opioids 0.364 0.554 −0.190
Oral hypoglycemics 0.136 0.085 0.051
Proton pump inhibitors 0.328 0.229 0.099
Skeletal muscle relaxants 0.374 0.265 0.109
Statins 0.491 0.315 0.176
Triptans 0.346 0.274 0.072
Urinary incontinence 0.432 0.296 0.136
Mean 0.408 0.335 0.073

FNCB/WE, Matwin et al 20101 factorized variant of the complement Naïve Bayes classifier as an improvement, using weight engineering on the features.

It is interesting that the SVM approach is inferior to our prior VP results for the attention deficit hyperactivity disorder (ADHD) topic, and that FCNB/WE is superior to both SVM and VP for the opioids topic, especially given that the SVM AUC measure is about 0.90 for both of these topics. Both the ADHD and opioids topics have very low article inclusion rates (2.4% and 0.8% respectively) and a relatively small number of positive samples (20 and 15 respectively). Clearly, there is an opportunity for future research in enhancing classifier performance at the very high recall end of the receiver-operating curve, especially with very small numbers of positive samples in the training data.

We are pleased to see other researchers investigating the important area of improving the efficiency of the systematic review process. We encourage Matwin et al to continue to improve their system, as we are, and to push the field forward, making these and other potentially effective tools available to support the systematic review process and evidence-based medicine.

Footnotes

Funding: National Institutes of Health; National Library of Medicine.

Provenance and peer review: Not commissioned; not externally peer reviewed.

References

  • 1.Matwin S, Kouznetsov A, Inkpen D, et al. A new algorithm for reducing the workload of experts in performing systematic reviews. J Am Med Inform Assoc 2010;17:446–53 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Cohen AM, Hersh WR, Peterson K, et al. Reducing workload in systematic review preparation using automated citation classification. J Am Med Inform Assoc 2006;13:206–19 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Cohen AM, Ambert K, McDonagh M. Cross-topic learning for work prioritization in systematic review creation and update. J Am Med Inform Assoc 2009;16:690–704 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Cohen A. Optimizing feature representation for automated systematic review work prioritization. AMIA Annu Symp Proc 2008:121–5 [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of the American Medical Informatics Association : JAMIA are provided here courtesy of Oxford University Press