Abstract
Aim:
The purpose of this paper is to review the literature on the clinical effectiveness of contemporary resin-based dentin bonding agents primarily focussing on the longevity of restoration.
Materials and Methods:
The literature published from June 2004 up to September 2010 was reviewed for clinical trials that tested the effectiveness of dentin bonding agents in the longevity of noncarious class V restoration. Results of each study reported using the USPHS criteria for clinical assessment of restoration were included and tabulated. The American Dental Association guidelines for dentin and enamel adhesives were used as a reference to compare the performance of individual bonding agents. Kruskal–Wallis followed by Mann–Whitney U was done to compare the mean Alfa score percentage for the three categories of bonding systems [etch-and-rinse (ER), self-etch primer (SEP), and self-etch-adhesive (SEA)].
Results:
A comparison of the mean Alfa score percentages revealed no difference between the ER, SEP, and SEA categories of bonding systems except for marginal adaptation where ER was found to be superior to SEA.
Conclusion:
The clinical effectiveness of resin-based bonding agents is comparable among the three categories.
Keywords: Bonding agents, clinical trials, noncarious cervical lesions, self-etch adhesives; systematic review, USPHS criteria
INTRODUCTION
Contemporary restorative techniques are on the basis of the adhesive properties of tooth-colored resin-based materials. Despite the significant improvements of adhesive systems, the bonded interface remains the weakest area of tooth-colored restorations. The most cited reasons for the failure of adhesive restorations placed with earlier adhesives are the loss of retention and the deficient marginal adaptation.[1,2] Current adhesive systems interact with the enamel/dentin substrate using three different strategies.[3,4]
First is by removing the smear layer (etch-and-rinse (ER) technique) using 30–40% phosphoric acid. Etch-and-rinse system bonding mechanism to dentin is diffusion-based and depends on hybridization of the resin within the exposed collagen mesh as well as into the dentin tubules,[5] creating a micromechanical interlocking of resin within the exposed collagen fibril scaffold. Simplified two-step ER adhesives combine the primer and the adhesive into one application (often referred to as “one-bottle” adhesives).
Second strategy is the “self-etch” adhesives (SEA) which employ the use of nonrinse acidic monomers that simultaneously condition and prime dentin. On dentin, they do not remove the smear layer but hybridize it to the underlying dentin. It impregnates the smear plugs fixing them to the internal tubular walls. There is simultaneous demineralization and infiltration of enamel and dentin to form a continuum in the substrate incorporating the smear plugs in the resin tag.[6] This forms a shallow but a uniform resin-infiltrated interface. Besides simplifying the bonding technique, the elimination of both rinsing and drying steps reduces the possibility of over-wetting or over-drying as they have a negative effect on bonding.[7]
A distinction should be made between “mild” and “strong” SEA. “Strong” SEA have a rather low pH (<1) and have been documented with a bonding mechanism and interfacial ultra-morphology resembling that produced by ER adhesives. Consequently, the underlying bonding mechanism of “strong” SEA is primarily diffusion-based, similar to the ER approach. “Mild” SEA (pH ± 2) only partially dissolves the dentin surface, so that a substantial amount of hydroxyapatite remains available within a submicron hybrid layer. On the basis of the steps of application they can be categorized as: a two-step “self-etch primers” (SEP) and a one-step “self-etch adhesives” (SEA).
Thirdly, glass-ionomers are still considered the only materials that are self-adhering to the tooth tissue.[8] Nevertheless, a short polyalkenoic acid pretreatment is recommended, resulting in a two-step approach. The polyalkenoic acid conditioner cleans the tooth surface; it removes the smear layer and exposes collagen fibrils up to about 0.5–1 mm depth;[9] herein, glass-ionomer components interdiffuse, establishing a micromechanical bond following the principle of hybridization.[3,10] Chemical bonding is additionally obtained by ionic interaction of the carboxyl groups of the polyalkenoic acid with calcium of hydroxyapatite that remains attached to the collagen fibrils.[8]
Although the laboratory testing of contemporary adhesives bonded to sound the tooth substrate under optimal laboratory conditions has been shown to predict clinical effectiveness,[4,11] the ultimate test method to assess bonding effectiveness remains a clinical trial. Peumans et al.,[12] in a systematic review, emphasised the need to standardize the conduct and reporting of clinical trials on bonding agents to enable interpretation of the best current evidence. Following are the criteria for conducting, evaluating, and reporting clinical trials undertaken to study the effectiveness of bonding agents: (1) Noncarious cervical lesions (NCCL), (2) Modified United States Public Health Services (USPHS) criteria, and (3) Consolidated Standards of Reporting Trials (CONSORT) statements.
Non-carious cervical lesions
Noncarious loss of dental hard tissue at the cervical region is used as a clinical model to evaluate the efficacy of dentin bonding agents in nonretentive tooth restorations, as recommended by the ADA.[13] The characteristics of NCCL are:[12] (1) cervical lesions do not provide any macromechanical retention; (2) they require for at least 50% bonding to dentin; (3) when restored, they result in an enamel as well as dentin margin; (4) they are widely available; (5) they are usually found in the anterior teeth or premolars with good access; (6) preparation and restoration of class-V lesions are minimal and relatively easy, reducing somewhat practitioner variability; (7) despite varying cavity configuration factors of class-V lesions, and thus resultant interfacial stress, the mechanical properties of the composite used are relatively unimportant; and (8) ineffective bonding commonly results in restoration loss, which is the most objective evaluation parameter.
Modified USPHS (Ryge’s criteria)
The modified USPHS/ Ryge criteria[14–17] [Table 1] have been used widely for the clinical evaluation of restorations. Although these criteria do not consider critical issues such as the oral hygiene index and number of decayed, missing and filled teeth, they are the only criteria available for long-term evaluation of restorations. They are considered valid criteria for comparison purposes among studies at different observation periods. The limitation of this system as reported by Hayashi and Wilson[18] is an overlap from Alfa to Bravo ratings for certain characteristics, including marginal adaptation. These variations for some characteristics at various recall examinations need to be interpreted with caution. To facilitate the uniformity among examiners, Fukushima et al.[19] emphasized the importance of interexaminer calibration/rating.
Table 1.
Criteria for modified U.S. Public Health Service and other direct evaluations
| Criterion | Test procedure | Score |
| Retention | Visual inspection with mirror and explore | Alfa: Yes (completely retained) |
| Charlie: No (partially or completely lost) | ||
| Color match | Visual inspection with mirror at 45 cm | Alfa: No mismatch in the room light in 3 to 4s (margins should be exempted from grading; interfacial staining should not affect grading) |
| Bravo: Perceptible mismatch (clinically acceptable) | ||
| Charlie: Esthetically unacceptable (clinically unacceptable) | ||
| Marginal discoloration | Visual inspection with mirror at 45 cm | Alfa: No |
| Bravo: Superficial staining (removable, usually localized) | ||
| Charlie: Deep staining (not removable, generalized) | ||
| Recurrent caries | Visual inspection, mirror, explorer, and radiographs | Alfa: No |
| Charlie: Yes | ||
| Loss of anatomical form (wear) | Visual inspection with a mirror and explorer, if needed | Alfa: No perceptible wear (or only localized wear) |
| Bravo: Generalized wear (clinically acceptable; 50% of margins are detectable; explorer catches going from material to tooth) | ||
| Charlie: Wear beyond dentinoenamel junction (DEJ) (clinically unacceptable) | ||
| Marginal adaptation (marginal integrity) | Visual inspection with mirror and explorer, if needed | Alfa: Undetectable |
| Bravo: Detectable (V-shaped defect in enamel only; explorer catches going both ways) | ||
| Charlie: Detectable (V-shaped defect to DEJ) | ||
| Surface texture | Visual inspection with mirror and explorer | Alfa: Smooth (better than or equal to microfilled composite) |
| Bravo: Rougher than microfilled composite | ||
| Charlie: Pitted | ||
| Postoperative sensitivity | Questioning the patients | Alfa: None |
| Charlie: Some | ||
| Other failure | Alfa: No | |
| Charlie: Yes |
CONSORT
This was initially formulated in 1996[20] and later revised in 2001.[21] The CONSORT statement (or simply CONSORT) comprises a checklist of essential items that should be included in reports of RCTs and a diagram for documenting the flow of participants through a trial. It is aimed at first reports of two-group parallel designs. The objective of CONSORT is to facilitate the critical appraisal and interpretation of RCTs by providing guidance to authors about how to improve the reporting of their trials.
To obtain provisional acceptance, dentin and enamel adhesive materials need to demonstrate that no more than 5% of the restorations are lost and that no more than 5% of the restorations show microleakage at the 6-month recall. To obtain full acceptance, dentin and enamel adhesive materials need to demonstrate that the cumulative incidence of clinical failures after 18 months is less than 10% for lost restorations and 10% for microleakage.[13]
Both laboratory and clinical studies[12,22] have shown that the GIC bonding mechanism is always superior to that achieved by adhesive resins. Hence this group of self adhering materials are not included for comparison in this review. The purpose of this paper was to review the current literature on the clinical effectiveness of resin-based adhesives when used to restore cervical noncarious class-V lesions.
MATERIALS AND METHODS
Peumans et al.[12] published a systematic review on the same research question and the review included clinical trials published until May 2004. Hence the current search included studies published from June 2004 to September 2010.
A PubMed search was conducted with the following key words: dentin bonding agents and noncarious cervical lesions. Specification of the time period in which articles were published, all articles published in English and clinical trials where the limits applied to refine the search. This yielded 366 articles on dentin bonding agents, 37 articles for noncarious cervical lesions, and 20 articles for combined search. Among the 366 articles on dentin bonding agents, 56 articles were short-listed after reading the titles (many included In vitro studies). After reviewing the abstracts of the 20 articles in the combined search and 56 articles on dentin bonding agents, 23 studies were included for the systematic review process. Clinical trials of which the data of successive recalls were reported in more than one paper were counted as separate studies.
The Alfa score percentage reported for the bonding agents tested in each study was tabulated under three categories namely, etch-and-rinse (ER), self-etch primer (SEP), and self-etch-adhesive (SEA). Among the parameters of the modified USPHS criteria, marginal discolouration, marginal adaptation, retention, secondary caries, and postoperative sensitivity were considered to be a direct measure of the effectiveness of bonding agents and hence only these parameters were tabulated. Kruskal–Wallis followed by Mann–Whitney U was done to compare the mean Afla score percentage for the three categories of bonding agents (ER, SEP, and SEA) using SPSS 15.0 (SPSS Inc, Chicago, USA).
The American Dental Association guidelines for dentin and enamel adhesives were used as a reference to compare the performance of individual bonding agents.
RESULTS
In general, in the 5.3 years of literature review of PubMed indexed articles, only 23 clinical trials have been reported. A lack of study detail was noted in most of the articles. Long-term follow-up (>5 years) was reported in 8 of the 23 studies. The list of clinical studies with comments on the methodology is shown in Table 2. Six of the 23 studies reported involved the enamel bevel and mechanical preparation of the dentin walls was performed in 16 of the studies reported. Only 5 of the reported studies have mentioned the sample size calculation.
Table 2.
List of clinical studies published in the past 5 years
| Study | Sclerotic dentin | Categorization of lesion size | Sample size calculation | Randomization | Mechanical surface preparation | Enamel bevel | USPHS criteria | Recall rate | Inter-evaluator rating |
| Van Meerbeek et al.[23] | + | + | – | + | + | + | – | + | – |
| Kubo et al.[24] | – | – | – | – | + | – | + | – | – |
| Abdalla and Garcia-Gody[25] | – | – | – | – | + | – | + | + | + |
| Loguercio et al.[26] | + | + | – | + | – | – | + | – | + |
| Burrow and Tyas[27] | – | + | – | – | – | – | – | + | – |
| Kurokawa et al.[28] | – | – | – | – | + | – | + | + | – |
| Loguercio et al.[29] | + | + | + | + | – | – | + | + | + |
| Sugizaki et al.[30] | – | – | – | – | + | – | + | + | – |
| Peumans et al.[31] | + | + | – | + | + | + | – | + | – |
| van Dijken et al.[32] | – | – | – | + | – | – | + | + | + |
| Pollington and van Noort[33] | – | – | – | – | – | – | + | + | – |
| Türkün and Celik[34] | – | + | – | – | – | – | + | – | – |
| van Dijken et al.[35] | – | – | – | + | – | – | + | + | – |
| Van Landuyt et al.[36] | + | + | + | + | + | + | – | + | – |
| Ritter et al.[37] | + | + | – | – | + | – | + | + | – |
| Kubo et al.[38] | – | – | – | + | + | + | + | + | – |
| Reis et al.[39] | – | + | + | + | – | – | + | + | + |
| Reis et al.[40] | + | + | + | + | – | – | + | – | + |
| Ritter et al.[41] | + | + | – | + | + | – | + | + | – |
| Wilder et al.[42] | + | + | – | + | + | – | + | + | – |
| Loguercio et al.[43] | + | + | + | + | – | – | + | – | + |
| Kubo et al.[44] | – | – | – | + | + | + | + | + | – |
| Yazici et al.[45] | – | – | – | – | – | + | + | + | – |
The Alfa score percentages reported in various studies is shown in Table 3. The mean Alfa score percentages for the different criteria of bonding agents are given in Table 4. There was no significant difference for retention, marginal discoloration, postoperative sensitivity, and secondary caries among the three categories [Figure 1]. However, there was a significant difference for a marginal adaptation between ER category and SEA category (P<0.05).
Table 3.
Alfa score percentage cited in modified USPHS criteria for various studies
| Adhesive category | Sample size (N/B^) | Recall period | Marginal discoloration | Marginal adaptation | Post-operative sensitivity | Retention | Secondary caries | Cumulative retention | Studies |
| Etch-and-Rinse | |||||||||
| Admira Bond | 60/65 | 2 years | 90.7 | 90.7 | 100 | – | – | – | Abdalla and Garcia-Gody[25] |
| Single Bond | 32/32 | 5 years | 84 | 94 | – | 100 | 100 | Kubo et al.[24] | |
| + QTH | 48/77 | 3 years | 68.7 | 68.7 | – | – | 100 | 84 | Yazici et al.[45] |
| + LED | 48/77 | 3 years | 77 | 77 | – | – | 100 | 84 | |
| One step plus X4 coats | 27/29 | 6 months | 84 | 100 | 100 | 96.3 | 100 | Loguercio et al.[26] | |
| 27/29 | 6 months | 60 | 86.7 | 100 | 77.8 | 100 | |||
| 23/31 | 2 years | 73.9* | 87* | 100 | 100 | 100 | Kubo et al.[38] | ||
| Clearfil LB | 27/27 | 5 years | 85 | 93 | – | 100 | 100 | Kubo et al.[24] | |
| Adper single bond | 38/39 | 3 years | 83.4* | 83.4 | 100 | 96.7 | 100 | Loguercio et al.[29] | |
| 39/42 | 3 years | 82 | 89.7 | – | 92.3 | Reis and Loguercio[39] | |||
| Allbond 2 | 53.7%# | 13 years | 4.1$ | van Dijken et al.[32]@ | |||||
| Clearfil LB | 26.3%# | 13 years | 2$ | ||||||
| Denthesive | 94.7%# | 13 years | 7.3$ | ||||||
| Gluma 2000 | 83.8%# | 13 years | 6.5$ | ||||||
| Gluma Solid bond + DS 1–2 | 25/26 | 100 | 92 | – | 100 | 100 | Ritter et al.[37] | ||
| Opti-bond | 40.6%# | 13 years | 3.1$ | van Dijken et al.[35] @ | |||||
| Permagen | 86.8%# | 13.0$ | |||||||
| Scotchbond multipurpose | 62.4%# | 4.8$ | |||||||
| Syntac classic | 36.4%# | 2.8$ | |||||||
| Opti-bond FL | 132/133 | 1 year | 93.6 | 61.7 | 90.3 | 99.3 | 100 | Van Landuyt et al.[36] | |
| One step | 39/42 | 3 years | 74.3 | 87.2 | – | 51.4 | Reis and Loguercio[29] | ||
| Opti-bond solo | 43/48 | 3 years | 88 | 98 | 98 | 98 | 100 | 93.3 | Ritter et al.[41] |
| Prime and bond 2.1 | 46/51 | 88 | 100 | 100 | 91 | 100 | 89.4 | ||
| Opti-bond solo | 29/48 | 8 years | 45 | 60 | 100 | 69 | 100 | 65.6 | |
| Prime and bond 2.1 | 27/51 | 69 | 100 | 100 | 59 | 100 | 60.6 | ||
| Opitbond dual cure | 95/100 | 1 year | 97 | 98 | 97 | 98 | 98 | Wilder et al.[42] | |
| 46/100 | 12 years | 73 | 94 | 100 | 89 | 100 | |||
| Self-Etch primers (SEP) | |||||||||
| Clearfil SE Bond | 50/50 | 2 years | 93 | 59 | 98 | 100 | 100 | Van Meerbeek et al.[23] @ | |
| + Acid etch | 50/50 | 2 years | 95 | 80 | 95 | 100 | 100 | ||
| 60/65 | 2 years | 92.3 | 92.3 | – | 100 | – | Abdalla and Garcia-Gody,[25] | ||
| 50/50 | 5 years | 68 | 17 | 100 | 98 | 100 | Peumans et al.[31] @ | ||
| + Acid etch | 50/50 | 5 years | 83 | 52 | 100 | 100 | 100 | ||
| Tyrian + one step plus | 27/29 | 6 months | 80 | 92 | 100 | 96.3 | 100 | Loguercio et al.[26] | |
| 4 × Tyrian + one step plus | 27/29 | 6 months | 75 | 87.5 | 100 | 96.3 | 100 | ||
| PUB 3 | 59.7%# | 13 years | 4.5$ | van Dijken et al.[35]@ | |||||
| Clearfil protect bond + Filtek supreme | 50/50 | 2 years | 92 | 92 | – | 100 | – | Türkün and Celik[34] | |
| Clearfil protect bond + Dyract eXtra | 50/50 | 2 years | 92 | 96 | – | 94 | – | ||
| ART bond | 41.3%# | 13 years | 3.2$ | van Dijken et al.[32] @ | |||||
| Denthesive 2 | 74.3%# | 13 years | 5.7$ | van Dijken[32] @ | |||||
| Self-Etch adhesives (SEA) | |||||||||
| Hybrid bond | 57/65 | 2 years | 64.6* | 73.8 | – | 100 | – | Abdalla and Garcia-Gody[25] | |
| One-up Bond F | 25/51 | 5 years | – | – | – | – | – | 92 | Burrow and Tyas[27] |
| Adper prompt L-Pop | 21/21 | 1 year | 100 | 52 | 100 | 100 | 100 | Kurokawa et al.[28] 2007 | |
| 34/39 | 3 years | 53.4 | 66.7 | 100 | 83.3 | 100 | Loguercio et al.[29] | ||
| Prompt L-Pop + Pertac II | 30/30 | 3 years | 92.3 | 83.3 | – | 86.6 | 100 | Pollington and van Noort[33] | |
| + Hytac | 30/30 | 3 years | 92.3 | 80 | – | 86.7 | 100 | ||
| AQ bond plus | 21/21 | 1 year | 100 | 33 | 100 | 100 | 100 | Kurokawa et al.[28] | |
| FB shake one | 24/24 | 1 year | 100 | 33 | 100 | 100 | 100 | Kurokawa et al.[28] | |
| G Bond | 14/14 | 1 year | 100 | 57 | 100 | 100 | 100 | Kurokawa et al.[28] | |
| 132/133 | 1 year | 88.6 | 43.2 | 89.5 | 98.5 | 100 | Van Landuyt et al.[36] | ||
| 54/55 | 2 years | 79 | 100 | – | 98 | 100 | Kubo et al.[38] | ||
| One up bond F+ | 18/18 | 1 year | 100 | 44 | 100 | 100 | 100 | Kurokawa et al.[28] | |
| Xeno III (SEA) | 30/30 | 18 months | 100 | 100 | 100 | 100 | 100 | Sugizaki et al.[30] | |
| iBond + DS 1–2 | 26/28 | 3 years | 69 | 81 | – | 100 | 100 | Ritter et al.[37] | |
| iBond + DS 3–4 | 20/25 | 3 years | 35 | 70 | – | 100 | 100 | ||
| iBond + DS 3–4+ Etching | 23/26 | 3 years | 75 | 85 | – | 87 | 100 | ||
| PSA | 56.6%# | 13 years | 4.4$ | van Dijken et al.[35] @ | |||||
| Clearfil S3 bond | 52/53 | 2 years | 79 | 100 | – | 98 | 100 | Kubo et al.[38] 2009 | |
| + AP-X | 46/49 | 3 years | 76 | 96 | – | 100 | 100 | Kubo et al.[44] 2010 | |
| + flow FX | 47/49 | 3 years | 74 | 98 | – | 94 | 100 | ||
| + Hydrophobic layer | 30/30 | 18 months | 53.3 | 70 | 73.3 | 76.6 | 76.6 | Reis et al.[40] | |
| 30/30 | 18 months | 76.6* | 83.3 | 86.6 | 93.3 | 93.3 | |||
| iBond Gluma inside | 30/30 | 18 months | 3.3 | 33.3 | 36.6 | 40 | 40 | ||
| iBond Gluma inside+ hydrophobic layer | 30/30 | 18 months | 56.6* | 80* | 80* | 83.3* | 83.3* | ||
| All bond SE + all bond SE liner | 28/33 | 2 years | 66.6 | 72.7 | 100 | 84.4 | 100 | Loguercio et al.[43] | |
| 30/33 | 2 years | 78.7 | 75.7 | 100 | 90.9 | 100 |
Data adapted to fit modified USPHS criteria,
B^Number of subject at baseline,
Statistically significant difference between groups,
Lost to follow up,
Annual failure rates, DS, dentin sclerosis;
ER, etch-and-rinse; SEP, self-etch-primer; SEA, self-etch-adhesive; QTH, quartz tungsten halogen unit; LED, light-emitting diode unit; AP-X, hybrid composite; Flow FX, flowable composite.
Table 4.
Mean Alfa score percentage for three categories of bonding agents
| Adhesive category | Criteria | N (number of studies) | Min% | Max% | Mean % | ± SD% |
| Etch-and-rinse (ER) | Marginal discoloration | 19 | 45.00 | 100.00 | 80.15 | 13.25 |
| Marginal adaptation | 19 | 60.00 | 100.00 | 87.43a | 12.34 | |
| Retention | 16 | 51.40 | 100.00 | 88.61 | 15.74 | |
| Post–op sensitivity | 12 | 90.30 | 100.00 | 98.77 | 2.84 | |
| Secondary caries | 16 | 98.00 | 100.00 | 99.87 | .50 | |
| Self-etch-primer (SEP) | Marginal discoloration | 9 | 68.00 | 95.00 | 85.59 | 9.55 |
| Marginal adaptation | 9 | 17.00 | 96.00 | 74.20 | 26.56 | |
| Retention | 9 | 94.00 | 100.00 | 98.29 | 2.26 | |
| Post-op sensitivity | 6 | 95.00 | 100.00 | 98.83 | 2.04 | |
| Secondary caries | 6 | 100.0 | 100.00 | 100 | 0 | |
| Self-etch-adhesive (SEA) | Marginal Discoloration | 24 | 3.30 | 100.00 | 75.55 | 23.60 |
| Marginal adaptation | 24 | 33.00 | 100.00 | 71.29b | 21.92 | |
| Retention | 24 | 40.00 | 100.00 | 91.69 | 13.17 | |
| Post-op sensitivity | 13 | 36.60 | 100.00 | 91.23 | 18.31 | |
| Secondary caries | 23 | 40.00 | 100.00 | 95.36 | 13.44 | |
Figure 1.

Mean Alfa score percentage of three categories of bonding agents
The adhesives tested in these studies are listed with the ADA full acceptance in Table 5. SEA were tested more frequently. Among the 17 ER bonding system studied in the reported trials, four bonding systems did not satisfy the ADA specification full acceptable criteria. All the four bonding systems (Scotchbond Multipurpose, One Step, Gluma 2000, and Denthesive) belonged to the two-step ER type. Among the 18 studies involving the two-step SEA (SEP, 6 agents) and one-step SEA (SEA, 12 agents), two (Denthesive 2 and Tyrian SPE), and three (Hybrid Bond, iBond Gluma inside, and PSA Dyract) bonding systems, respectively, did not satisfy ADA specification full acceptable criteria.
Table 5.
List of bonding agents tested in clinical studies with chemical composition and ADA acceptance
| Material | Composition | ADA full acceptance |
| Etch and rinse | ||
| Admira Bond (VOCO, Cuhaven, Germany) | Etchant: 36% phosphoric acid | Yes[25] |
| Adhesive: Acetone, bonding ormocer, dimethacrylates, initiators, stabilizers. | ||
| Scotchbond Multi-Purpose (3M ESPE, St.Paul, Minn.USA) | Conditioner: 10% maleic acid | No[35] |
| Primer: 40% HEMA, 13% polyalkeonic acid copolymer with methacrylate groups, water | ||
| Adhesive: HEMA, bis-GMA, hexafluorophosphate, photoinitiator | ||
| Adper Single Bond (3M ESPE, St.Paul, Minn. USA) | Scotchbond (3M ESPE): 37% phosphoric acid | Yes[29,39] |
| Adhesive: Bis-GMA, HEMA, dimethacrylates, polyalkenoic acid copolymer, initiators, water, ethanol | ||
| Clearfil LB (Kurary, Osaka, Japan) | Conditioner: 10% Citric acid, 20% CaCl2, 6 % Colloidal silica thickener, water. | Yes[24] |
| Primer: 3% 5-NMSA (N-methacryloxy 5-aminosalisic acid) | ||
| Bonding agent: 10-MDP, bis-GMA, HEMA, Photoinitiator. | ||
| All Bond 2 ((Bisco, Schaumburg, IL, USA) | Etchant: 32% phosphoric acid | Yes[32] |
| Primer A: 2% NTG-GMA (N-p-tolyl-glycine-glycidyl methacrylate), photoinitiator. | ||
| Primer B: 16% BPDM (biphenoldimethacrylate), photoinitiator, ethanol, acetone. | ||
| Adhesive: bis-GMA, UDMA, 2-HEMA. | ||
| Gluma 2000 | Etchant: Oxalic acid 6.1%, aluminium nitrate 2.6%, glycine 2.7%, water (pH 1.3) | No[32] |
| Primer/ Adhesive: N-methacryloxyethyl-N-methylformamide, bis-GMA, acetic acid, ethanol. | ||
| One Step (Bisco, Schaumburg, IL, USA) | Uni-etch: 32% Phosphoric acid | No[29] |
| Adhesive: Bis-GMA, BPDM, HEMA, initiator and Acetone. | ||
| One Step Plus (Bisco, Schaumburg, IL, USA) | Uni-etch: 32% Phosphoric acid | Yes for retention, No for marginal discoloration[26,38] |
| Adhesive: HEMA, BPDM, photoinitiator, Dental glass | ||
| Optibond Dual Cure (Kerr, Orange, CA, USA) | Etchant: 37% phosphoric acid | Yes[42] |
| Primer:2-Hydroxyethyl methacrylate (HEMA), Glycerol phosphate dimethacrylate, Mono (2-methacryloxyethyl) phthalate, Ethanol, Water | ||
| Adhesive: Catalyst resin liquid Bisphenol A glycidyldimethacrylate, HEMA, Chemical and light-cure catalyst | ||
| Accelerator paste: 48 percent filled by weight | ||
| Barium aluminum borosilicate glass, Fumed silica, Disodium hexafluorosilicate, Barium borosilicate glass, HEMA, Glycerol dimethacrylate | ||
| Optibond FL (Kerr, Orange, CA, USA) | Etchant: 38% Phosphoric acid | Yes[36] |
| Primer: HEMA, glycerol phosphate dimethacrylate (GDMA), mono-2-methacryloxyethyl phthalate (MMEP), water, ethanol, Camphoroquinone, butylhydroxy toluene | ||
| Adhesive (Optibond dual cure): | ||
| A activator: Bis-GMA, HEMA, GDPM, catalyst (benzoyl peroxide and camphoroquinone) | ||
| B paste: filler (fumed SiO2, Ba-Al-B-Si, Na2SiF2), disodium hezafluorosilicate, HEMA, tertiary amine | ||
| Permagen (Ultradent Prod Inc, Utah, USA) | Etchant: 10% phosphoric acid | No[35] |
| Primer: A:NTG-GMA (N-tolyglycine-glycidil mehtacrylate) | ||
| B: proprietary hydrophilic resin, acetone. | ||
| Adhesive: 2-HEMA, bis-GMA | ||
| Syntac Classic (Ivoclar-Vivadent, Schann, Liechtenstein) | Etchant: 36% phosphoric acid | Yes[35] |
| Primer: 25% TEGDMA, 4% maleic acid, water | ||
| Adhesive: 35% PEGDMA (polyethylene glycol dimethacrylate), 5% gluteraldehyde, 60% water | ||
| Resin (Heliobond): 60% bis-GMA, 40% TEGDMA | ||
| Single Bond (3M ESPE, St.Paul, Minn.USA) | Etchant: 37.5% phosphoric acid | Yes[24] |
| Adhesive: HEMA, bis-GMA, water, ethanol, dimethacrylates, photoinitiator system, methacrylate functional copolymer of polyacrylic acid and polyitaconic acid | ||
| Denthesive (Heraeus Kulzer, Wehrheim, Germany) | Etchant: 5% EDTA (2 NaOH to pH 4.5) | No[32] |
| Primer A: methacryloxyethylmaleate, ethanol. | ||
| B: 2-HEMA, phosphate, ethanol (pH 2.3) | ||
| Adhesive: Highly filled dimethacrylate | ||
| Gluma Solid Bond (Heraeus Kulzer Hanau, Germany) | Etchant: 20% Phosphoric acid, Pyrogenic silica, Blue dye. | Yes[37] |
| Primer: Maleic acid, HEMA, Mod. Polyacrylic acid, water, ethanol. | ||
| Adhesive: Bis-GMS, TEGDMA, HEMA, Carboxylic acid, Filler 25% (Ba-Al-B-F-Si glass and pyrogenic silica) | ||
| Prime and Bond 2.1 | Etchant: 34% Phosphoric acid | Yes[41] |
| Adhesive: BisGMA, PENTA-P, photoinitiator, cetylamine hydrofluoride, acetone | ||
| OptiBond Solo | Etchant: 37% Phosphoric acid | Yes[41] |
| Adhesive: Alkyl dimethacrylate resin, Barium aluminosilicate glass, Sodium Hexafluorosilicate, fumed silica, ethyl alcoho | ||
| Self-Etch Primer (SEP) | ||
| ART Bond (Coltene, Alstatten, Switzerland) | Primer A: 1.6% Maleic acid, NaF, water. | Yes[32] |
| Primer B: 36% HPMA (hydroxypropyl methacrylate), 6.2% PMA (polymethacrylic oligomaleic acid), 47% 2-HEMA, water. | ||
| Adhesive: 44% isopropylidenbis, 7% PMA, 49% DMA (dioxaoctamethylendimethacrylate), bis-GMA, TEGDMA. | ||
| PUB 3 (Denstply, Konstanz, Germany) | Primer: 30% HEMA, 6% PENTA (dipentaerythreitol pentacrylate phosphonate ester), ethanol. | Yes[35] |
| Adhesive: 4.5% PENTA, 25% TEGDMA, HEMA, 0.5% gluteraldehyde, 50% UDMA, photoinitiator | ||
| Clearfil SE (Kuraray, Tokyo, Japan) | Primer: 10-MDP, HEMA, hydrophilic dimethacrylate, CQ, | Yes[23,25,31] |
| N,N-diethanol p-toludine, water | ||
| Adhesive: 10-MDP, Bis-GMA, HEMA, hydrophilic dimethacrylate, CQ, N,N-diethanol p-toludine, silanized colloidal silica | ||
| Clearfil Protect Bond (Kuraray, Osaka, Japan) | Primer: 5% MDPB, MDP, HEMA, hydrophobiic dimethacrylate, photoinitiators, water | Yes[34] |
| Adhesive: MDP, Bis-GMA, HEMA, hydrophilic dimethacrylate, dicamphoroquinone, NaF, silanized colloidal silica | ||
| Denthesive 2 (Heraeus Kulzer, Wehrheim, Germany) | Primer A: 2% Maleic acid, water | No[32] |
| B: 82% HEMA, 3.6% maleic acid-mono-methacryloyl-oxy-propylester, 3.6% methacrylated polycarboxylic acid, TEGDMA, photoinitiator, stabilisator, water | ||
| Adhesive: (Adhesive Bond II) 43.5% bis-GMA, 7% maleic acid-mono-2-methacryloxyethyl, 48.5% TEGDMA, photoinitiator. | ||
| Tyrian SPE (Bisco, Schaumburg, IL, USA) | Self-etching Part A: 20-30% Ethanol | No[26] |
| Self-etching Part B: 2-acryl amido-2-methyl propane sulfonic acid (30-50%); bis2-(methacryloxyethyl) phosphate GMA (5-15%); Ethanol (40-70%) | ||
| Adhesive: bis-GMA and BPDM (15-40%); HEMA (15-40%); dental glass (1-10%) and acetone (40-70%) | ||
| Self- Etch Adhesive (SEA) | ||
| Clearfil S3 Bond (Kuraray, Osaka, Japan) | Methacryloyloxydodecyl dihydrogen phosphate (10 MDP), 2-HEMA, bisphenol A, diglycidyl methacrylate, water, ethanol, silanated colloidal silica, camphorquinone, photoinitiator. | Yes[38,44] |
| G Bond (GC Corp, Tokyo, Japan) | 4-MET, phosphoric acid monomer, UDMA, Acetone, Water, Silinated colloidal silica and initiator | Yes[28,36,38] |
| AQ Bond plus (Sun Medicals) | 4-META, UDMA, MMA, Water, Acetone, initiator, p-toluenesulphonate, reductant | Yes[28] |
| Hybrid Bond (Vivadent, Schann, Liechtenstein) | MMA, 4-META, tri (2-hydroxyethyl)-isocyanurat-triacrylate(THIT), HEMA, Acetone, Water. | No[25] |
| All Bond SE (Bisco, Inc) | Part I: Ethanol, benzene sulfinate dehydrate | Yes for SEA+Liner[43] |
| Part II: Bis(glyceryl 1,3 dimethacrylate, biphenyl dimethacrylate. | ||
| All Bond SE Liner (hydrophobic): Bisphenol A diglycidylmethacrylate, HEMA, glass frit. | ||
| iBond Gluma inside (Heraeus Kulzer, Hanau, Germany) | 4-MET, UDMA, glutaraldehyde, acetone, water, stabilizer, photoinitiator. | No[40] |
| Fluorobond Shake One (Shofu, Tokyo, Japan) | PRG, Fluoroaluminosilicate glass, 4-AET, 4-AETA, bis-GMA, HEMA, Water, solvent, initiator. | Yes[28] |
| One up Bond F+ (Tokuyama Corp, Tokyo, Japan) | MAC-10, HEMA, MMA, multifunctional methacrylic monomer, fluoroaluminosilicate glass, water, photoinitiator, arly borate catalyst | Yes[28] |
| PSA Dyract (Dentsply, Konstanz, Germany) | PENTA, TEGDMA, elastomeric urethane-modified bis-GMA resin, fluoride, acetone, photoinitiator | No[35] |
| Xeno III (Dentsply, Sankin) | Catalyst liquid: Methacryloyloxyethyl acid, UDMA, fluoride-releasing phosphozene monomer and photosensitizer. | Yes[30] |
| Universal liquid: HEMA, Ethanol, Water, Microfilled particles. | ||
| Adper Prompt L-Pop (3M ESPE, St.Paul, Minn.USA) | Liquid 1: Methacrylated phosphoric esters, Bis- GMA, initiators based on camforoquinone, stabilizers | Yes for retention, No for marginal discoloration[28,29] |
| Liquid 2: Water, HEMA, polyalkenoic acid, copolymer, stabilizers | ||
| Prompt L-Pop (3M ESPE, St.Paul, Minn.USA) | Water, methacrylated-phosphoric acid-HEMA ester, BAPO initiator, fluoride complex parabens | No[33] |
DISCUSSION
In a systematic review, Heintze[46] found that the results of bond strength tests did not correlate with laboratory tests that evaluated the marginal seal of restorations such as microleakage or gap analysis. The quantitative marginal analysis of Class V fillings in the laboratory was unable to predict the performance of the same materials In vivo. The review suggested that microleakage tests or the quantitative marginal analysis should be abandoned and research should focus on laboratory tests that are validated with regard to their ability to satisfactorily predict the clinical performance of restorative materials. Peumans et al.[12] reported the results of 32 clinical trials, and the current review on 23 trials is a clear indication of interest in understanding the clinical behaviour of adhesive materials.
Certain level of uniformity while conducting clinical trials will allow comparisons of the results with other studies, thus enabling current best evidence.[47] In some papers under the current review, the materials and methods were poorly described (insufficient information provided regarding patient selection and in-/exclusive criteria, recall rates, reasons of patient-drop out, inter-evaluator agreement, etc.). In addition, a large variety in study design (not uncommonly without a proper control or “gold standard”, a “paired-tooth” design, adequate randomization, a sample size calculation, a sufficiently long follow-up), was noticed in these clinical trials, which makes it difficult to compare the overall clinical performance of adhesives.
To increase the power of a class-V clinical trial, the study methodology must also be standardized better in the future. In many studies, patient-related factors, such as age, oral hygiene, occlusal loading and dentin sclerosis are more determining than any material property.[48,49] This patient factor can be ruled out by applying a balanced study design. In such a set-up, pairs of equal teeth (for instance, first and second premolar at the same side, left and corresponding right incisor, canine and premolar, respectively) with similar lesions are chosen in each patient and each tooth is assigned to one of the experimental treatments in a randomized manner.[48] Also an adequate number of patients, rather than restorations, are paramount to extend the results from the statistical sample to the population; statistical power analysis can help to determine the number of patients required. In addition, recall periods must be standardized more, evaluation criteria must be assessed by calibrated independent examiners following a standard index system, and recall rates and reasons for patient drop-out must be reported as well.
Retention, marginal integrity, and marginal discoloration (clinical microleakage) are usually the key parameter used to judge upon clinical effectiveness of adhesives and modified USPHS criteria allows such assessments. The use of uniform reporting criteria would enable comparison of clinical effectiveness. Although significant information was reported by some studies,[27,32,35] their retention rates could not be used for statistical analysis in the current review due to a different protocol to assess clinical effectiveness. Certain studies[23,31,36] which did not employ USPHS criteria could still be adapted to fit the criteria since the assessment criteria were similar.
In a comprehensive systematic review of contemporary bonding agents,[12] it was concluded that the clinical effectiveness of two-step ER adhesives was greater than that of one-step SE adhesives. However, the current systematic review found the clinical performance of different categories of bonding agents was similar. Postoperative sensitivity and secondary caries were not seen to be a clinical problem with any category of bonding systems. This finding may probably due to the selection of NCCL. NCCL have higher degree of dentinal sclerosis thus offering protection from sensitivity.[50] In general, all three categories of bonding systems had retention rates of 88.61–98.29%.
The ER category the mean Alfa score for retention was seen to be 88.61% which is a little lower than the other two categories. This observation is probably attributed to the studies involving ER have a longer follow-up period resulting in lesser retention. The lowest retention (51%) observed with One Step (Bisco).[39] This acetone-based material when applied, results in thin layers following solvent evaporation, which is more susceptible to inhibition of polymerization[51] and the amount of acetone[52] directly affects the bonding. Among the 17 clinical studies involving ER, three (Scotchbond MP, One Step, and Denthesive) bonding agents did not qualify the ADA full acceptance. The poor performance of Scotchbond MP[35] was due to the use of 10% maleic acid instead of 37% phosphoric acid as a dentin conditioner. A 94.7% lost to follow-up was reported for the Denthesive group following 13 years of clinical evaluation.[32] Results of a study with such a low recall rate have to be interpreted with caution. The failure of One Step was attributed to composition[12] which was addressed and reintroduced as One Step Plus.[45]
The number of studies related to SEPs reported is less with low follow-up period. Among the six reported SEP agents in the clinical studies, Denthesive 2 and Tyrian SPE did not fulfil the ADA full acceptance criteria. The reason for clinical failure of Tyrian SPE used with One Step Plus could be due to increased amount of solvent (ethanol) to promote ionization of acidic monomers, leading to entrapment of water and solvent, thus affecting the degree of conversion of polymer.[53] Denthesive 2 employs 2% maleic acid in the primer which may not produce effective etching of enamel/dentin.[32]
The clinical performance of SEA was satisfactory in all criteria except for marginal adaptation showing inferior results compared to ER category, however comparable to SEP. The reason for this could be attributed to one study involving five SEA bonding agents.[28] This study observed a marginal breakdown as early as 3 months and less than 50% had Alfa scores at the end of one year. In general, failure on marginal adaptation may be caused due to thermal and mechanical stresses in the oral environment,[54] viscoelastic property of the restorative material,[55] water sorption and hydrolysis along the tooth-restorative interface[56] and unique stress patterns at the cervical margin of the tooth.[57] However, this study could not reason their findings.
The Alfa score percentages for marginal staining and marginal adaptation in general were low when compared to ER and SEP categories. The relationship between marginal staining and marginal adaptation has been discussed in studies.[24,31,38] Approximately, 70% of the marginal discoloration was seen at the mesial and/or distal margins of the restoration, where it is difficult to access during finishing and polishing.[43] Hence, the cause of staining could have been the accumulation of stains at the marginal step and crevice and not microleakage.[24,36,38]
Among the 12 SEA tested, 4 (Hybrid Bond, iBond Gluma inside, Prompt L-Pop, and PSA Dyract) did not meet the ADA specification. Both Hybrid Bond and iBond Gluma inside contain methacryloxyethyltrimellitic anhydride (4-META) as an active monomer component. SEA containing 4-META get converted to dicarboxylic 4-MET in the aqueous medium leading to a pH of 1 with a potential to etch dental hard tissue.[58] Due to the absence of the hydrophilic bonding agent in SEA systems, following polymerization, these materials behave like semipermeable membranes leading to hydrolysis of the bond. The marginal discoloration of iBond Gluma inside was attributed to rapid hydrolysis of 4-methacryloyloxyethyl trimellitic acid– (4-MET-), which are temperature-dependent, and discoloration had appeared as early as 1 month.[59,60] SEA that contain PENTA as an acidic monomer (PSA Dyract) are known to hydrolyze overtime resulting in microleakage and compromise long-term bonding effectiveness.[61] However, Mjor and Toffenetti[62] have reported that narrow gaps, crevices, ditches, and microleakage adjacent to composite restoration do not lead to secondary caries. Therefore, monitoring marginal staining is recommended to extend the longevity of restoration as well as the teeth.
In terms of adhesion durability, 3-step ER is considered as the “gold standard” among all bonding systems.[22] The problems related to SEA arise due to[22] (1) they are too hydrophilic and act, even after polymerization, as semipermeable membranes; (2) because of the high solvent concentration, it is impossible to obtain an adhesive resin layer of adequate thickness and void from residual solvent; (3) during solvent evaporation, the monomer/water ratio may change and subsequently result in phase separations and blistering; and (4) the acidic components of these adhesives may also adversely interact with the initiator system of the composite and so weaken the bonding complex.
On the contrary, clinical performance of SEA comparable to ER system was observed in the present review. This could be attributed to the following reasons, which could help overcome the limitations of SEA:
Enamel bevel was placed in six of the studies [Table 2]. Unground enamel surfaces with the prismless structure are contaminated with oral fluid and covered with pellicle, which might prevent bonding between the adhesive and resin,[63] especially the efficacy of mild SEA.[64] Hence, the placement of enamel bevel could have enabled better etching of enamel yielding better retention rates.
Chemical composition of certain SEP (Clearfil SE Bond and Clearfil Bond Protect) contains 10-MDP as a functional monomer dissolved in water and ethanol with a pH around 2. This hydrophilic monomer improves the wetting on the moist surface[61] and in addition the hydroxyl groups chelate with calcium forming chemical bonds.[65] This leads to stabilization on the interfacial bond. These systems (Clearfil SE Bond/Bond Protect/S3 Bond, G Bond, All Bond SE, Fluorobond Shake One, One up Bond F+ and Xeno III) also contain silica nanoparticles which result in a thicker adhesive layer acts a flexible interface that relieves interfacial stress between shrinking composite and rigid dentin.[66] In addition, the presence of polyalkenoic acid copolymer (Adper Prompt L-Pop) can form Capolyalkenoate complexes at the superficial region of the hybrid layer and within the superficial 3 µm of dentinal tubules,[8] which might stabilize the bonded interface by providing water stability and a stress-relaxing effect.[67]
While employing the self-etch system, a pretreatment using 37% phosphoric acid has been found to improve retention rates.[23,24,31]
Application of two coats of adhesive has been found to increase bonding efficacy.[26,27] Consecutive coats can promote removal of water and solvent and allow more resin uptake into the collagen fibril network.[68]
The hydrophobic layer application has shown to improve retention rates of self-etch systems.[40] By applying a nonsolvent hydrophobic adhesive layer over a surface that was treated with a SEA system, the concentration of the hydrophobic monomers increases. This, in turn, reduces water sorption at the adhesive layer. In addition, the increased adhesive layer thickness leads to a thicker and more uniform adhesive layer with lower concentrations of retained water and solvent, which is known to reduce the detrimental effects of polymerization shrinkage of resin-based composite restorations.[69,70]
It must be noted that the clinical studies included for review provide short-term success rates. It would be interesting to study the long-term success rates of the same clinical studies which will enlighten on the true performance of self-etch bonding systems. In addition, the so-called self-etching systems were introduced to minimize the number of critical clinical steps involved in bonding. However, it is noted that methods to overcome the limitations of self-etching systems tend to increase the number of clinical steps.
CONCLUSIONS
With the available results of short-term clinical studies, it can be concluded that:
Early loss of retention may not be the main cause of clinical failure.
The clinical effectiveness of SEP and SEA are comparable to ER bonding systems.
Acknowledgments
The author would like to thank the Editor, Dr. Gopi Krishna for inviting to write this systematic review. The author would also like to thank all the post graduate students of the Dept. of Conservative Dentistry and Endodontics for helping in collecting the literature, in particular, Dr. Ashwin, Dr. Spoorthy and Dr. Jojo.
Footnotes
Source of Support: Nil
Conflict of Interest: None declared
REFERENCES
- 1.Mjor IA, Gordan VV. Failure, repair, refurbishing and longevity of restorations. Oper Dent. 2002;27:528–34. [PubMed] [Google Scholar]
- 2.Mjor IA, Shen C, Eliasson ST, Richter S. Placement and replacement of restorations in general dental practice in Iceland. Oper Dent. 2002;27:117–23. [PubMed] [Google Scholar]
- 3.Van Meerbeek B, Vargas S, Inoue S, Yoshida Y, Peumans M, Lambrechts P, et al. Adhesives and cements to promote preservation dentistry. Oper Dent. 2001;26:S119–44. [Google Scholar]
- 4.Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, et al. Buonocore memorial lecture. Adhesion to enamel and dentin: Current status and future challenges. Oper Dent. 2003;28:215–35. [PubMed] [Google Scholar]
- 5.Abdalla AI, Davidson CL. Bonding efficiency and interfacial morphology of one-bottle adhesives to contaminated dentin surfaces. Am J Dent. 1998;11:281–5. [PubMed] [Google Scholar]
- 6.Perdigao J, May KN, Jr, Wilder AD, Jr, Lopes M. The effect of depth of dentin demineralization on bond strengths and morphology of hybrid layer. Oper Dent. 2000;25:186–94. [PubMed] [Google Scholar]
- 7.Van Meerbeek B, Yoshida Y, De Munck J, Inoue S, Vargas M, Lambrechets P, et al. Correlative morphology and clinical characterization of tooth biomaterial interaction in: Self-etch primer: Current status and its evolution. Tokyo: Proceedings of the international symposium 2001; 2001. pp. 41–55. [Google Scholar]
- 8.Yoshida Y, Van Meerbeek B, Nakayama Y, Snauwaert J, Hellemans L, Lambrechts P, et al. Evidence of chemical bonding at biomaterial-hard tissue interfaces. J Dent Res. 2000;79:709–14. doi: 10.1177/00220345000790020301. [DOI] [PubMed] [Google Scholar]
- 9.Inoue S, Van Meerbeek B, Abe Y, Yoshida Y, Lambrechts P, Vanherle G, et al. Effect of remaining dentin thickness and the use of conditioner on micro-tensile bond strength of a glass-ionomer adhesive. Dent Mater. 2001;17:445–55. doi: 10.1016/s0109-5641(01)00003-3. [DOI] [PubMed] [Google Scholar]
- 10.Lin A, Mcintyre N, Davidson R. Studies on the adhesion of glass ionomer cements to dentin. J Dent Res. 1992;71:1836–41. doi: 10.1177/00220345920710111401. [DOI] [PubMed] [Google Scholar]
- 11.De Munck J, Peumans M, Poitevin A, Lambrechts P, Braem M, Van Meerbeek B. Durability of adhesion to tooth tissue: Methods and results. J Dent Res. 2005;84:118–32. doi: 10.1177/154405910508400204. [DOI] [PubMed] [Google Scholar]
- 12.Peumans M, Kanumilli P, De Munck J, Van Landuyt K, Lambrechts P, Van Meerbeek B. Clinical effectiveness of contemporary adhesives: A systematic review of current clinical trials. Dent Mater. 2005;21:864–81. doi: 10.1016/j.dental.2005.02.003. [DOI] [PubMed] [Google Scholar]
- 13.Acceptance program guidelines: Dentin and enamel adhesive materials. Chicago: American Dental Association; 2001. American Dental Association Council on Scientific Affairs; p. 12. [Google Scholar]
- 14.Cvar JF, Ryge G. Department of Health, Education, and Welfare, Public Health Service, National Institutes of Health, Bureau of Health Manpower Education, Division of Dental Health, Dental Health Center. San Francisco: US: DHEW publication; 1971. Criteria for the clinical evaluation of dental restorative materials. San Francisco: U.S; pp. 790–244. [Google Scholar]
- 15.Heymann HO, Sturdevant JR, Brunson WD, Wilder AD, Sluder TB, Bayne SC. Twelve-month clinical study of dentinal adhesives in class V cervical lesions. J Am Dent Assoc. 1988;116:179–83. doi: 10.14219/jada.archive.1988.0345. [DOI] [PubMed] [Google Scholar]
- 16.Barnes DM, Blank LW, Gingell JC, Gilner PP. A clinical evaluation of a resin-modified glass ionomer restorative material. J Am Dent Assoc. 1995;126:1245–53. doi: 10.14219/jada.archive.1995.0359. [DOI] [PubMed] [Google Scholar]
- 17.Cvar JF, Ryge G. Reprint of criteria for the clinical evaluation of dental restorative materials. Clin Oral Invest. 2005;9:215–32. doi: 10.1007/s00784-005-0018-z. [DOI] [PubMed] [Google Scholar]
- 18.Hayashi M, Wilson NH. Marginal deterioration as a predictor of failure of a posterior composite. Eur J Oral Sci. 2003;111:155–62. doi: 10.1034/j.1600-0722.2003.00020.x. [DOI] [PubMed] [Google Scholar]
- 19.Fukushima M, Setcos JC, Iwaku M. Posterior composite restoration failures in five-year clinical studies (abstract 792) J Dent Res. 1992;71:204. [Google Scholar]
- 20.Begg C, Cho M, Eastwood S, Horton R, Moher D, Olkin I, et al. Improving the quality of reporting of randomized controlled trials. The CONSORT statement. JAMA. 1996;276:637–9. doi: 10.1001/jama.276.8.637. [DOI] [PubMed] [Google Scholar]
- 21.Altman DG, Schulz KF, Moher D, Egger M, Davidoff F, Elbourne D, et al. The Revised CONSORT Statement for Reporting Randomized Trials: Explanation and Elaboration. Ann Intern Med. 2001;134:663–94. doi: 10.7326/0003-4819-134-8-200104170-00012. [DOI] [PubMed] [Google Scholar]
- 22.De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, et al. A critical review of the durability of adhesion to tooth tissue: Methods and results J Dent Res. 2005;84:118–32. doi: 10.1177/154405910508400204. [DOI] [PubMed] [Google Scholar]
- 23.Van Meerbeek B, Kanumilli P, De Munck J, Landuyt KV, Lambrechts P, Peumans M. A randomized controlled study evaluating the effectiveness of a two-step self-etch adhesive with and without selective phosphoric-acid etching of enamel. Dent Mater. 2005;21:375–83. doi: 10.1016/j.dental.2004.05.008. [DOI] [PubMed] [Google Scholar]
- 24.Kubo S, Kawasaki K, Yokota H, Hayashi Y. Five-year clinical evaluation of two adhesive systems in non-carious cervical lesion. J Dent. 2006;34:97–105. doi: 10.1016/j.jdent.2005.04.003. [DOI] [PubMed] [Google Scholar]
- 25.Abdalla AI, García-Godoy F. Clinical evaluation of self-etch adhesives in Class V non-carious lesions. Am J Dent. 2006;19:289–92. [PubMed] [Google Scholar]
- 26.Loguercio AD, Costenaro A, Silveira AP, Ribeiro NR, Rossi TR, Reis A. A six-month clinical study of a self-etching and an etch-and-rinse adhesive applied as recommended and after doubling the number of adhesive coats. J Adhes Dent. 2006;8:255–61. [PubMed] [Google Scholar]
- 27.Burrow MF, Tyas MJ. Five-year clinical evaluation of One-Up Bond F in non-carious cervical lesions. Am J Dent. 2007;20:361–4. [PubMed] [Google Scholar]
- 28.Kurokawa H, Miyazaki M, Takamizawa T, Rikuta A, Tsubota K, Uekusa S. One-year clinical evaluation of five single step adhesive systems in non-carious cervical lesions. Dent Mater J. 2007;26:14–20. doi: 10.4012/dmj.26.14. [DOI] [PubMed] [Google Scholar]
- 29.Loguercio AD, Bittencourt DD, Baratieri LN, Reis A. A 36-month evaluation of self-etch and etch-and-rinse adhesives in noncarious cervical lesions. J Am Dent Assoc. 2007;138:507–14. doi: 10.14219/jada.archive.2007.0204. [DOI] [PubMed] [Google Scholar]
- 30.Sugizaki J, Morigami M, Uno S, Yamada T. Clinical evaluation and interfacial morphology observation of Xeno III self-etching resin bonding and restorative system. Dent Mater J. 2007;26:602–7. doi: 10.4012/dmj.26.602. [DOI] [PubMed] [Google Scholar]
- 31.Peumans M, De Munck J, Van Landuyt K, Lambrechts P, Van Meerbeek B. Five-year clinical effectiveness of a two-step self-etching adhesive. J Adhes Dent. 2007;9:7–10. [PubMed] [Google Scholar]
- 32.van Dijken JW, Sunnegårdh-Grönberg K, Lindberg A. Clinical long-term retention of etch-and-rinse and self-etch adhesive systems in non-carious cervical lesions. A 13 years evaluation. Dent Mater. 2007;23:1101–7. doi: 10.1016/j.dental.2006.10.005. [DOI] [PubMed] [Google Scholar]
- 33.Pollington S, van Noort R. A clinical evaluation of a resin composite and a compomer in non-carious Class V lesions. A 3-year follow-up. Am J Dent. 2008;2:49–52. [PubMed] [Google Scholar]
- 34.Türkün LS, Celik EU. Noncarious class V lesions restored with a polyacid modified resin composite and a nanocomposite: A two-year clinical trial. J Adhes Dent. 2008;10:399–405. [PubMed] [Google Scholar]
- 35.van Dijken JW, Pallesen U. Long-term dentin retention of etch-and-rinse and self-etch adhesives and a resin-modified glass ionomer cement in non-carious cervical lesions. Dent Mater. 2008;24:915–22. doi: 10.1016/j.dental.2007.11.008. [DOI] [PubMed] [Google Scholar]
- 36.Van Landuyt KL, Peumans M, Fieuws S, De Munck J, Cardoso MV, Ermis RB, et al. A randomized controlled clinical trial of a HEMA-free all-in-one adhesive in non-carious cervical lesions at 1 year. J Dent. 2008;36:847–55. doi: 10.1016/j.jdent.2008.06.005. [DOI] [PubMed] [Google Scholar]
- 37.Ritter AV, Heymann HO, Swift EJ, Jr, Sturdevant JR, Wilder AD., Jr Clinical evaluation of an all-in-one adhesive in non-carious cervical lesions with different degrees of dentin sclerosis. Oper Dent. 2008;33:370–8. doi: 10.2341/07-128. [DOI] [PubMed] [Google Scholar]
- 38.Kubo S, Yokota H, Yokota H, Hayashi Y. Two-year clinical evaluation of one-step self-etch systems in non-carious cervical lesions. J Dent. 2009;37:149–55. doi: 10.1016/j.jdent.2008.10.008. [DOI] [PubMed] [Google Scholar]
- 39.Reis A, Loguercio AD. A 36-month clinical evaluation of ethanol/water and acetone-based etch-and-rinse adhesives in non-carious cervical lesions. Oper Dent. 2009;34:384–91. doi: 10.2341/08-117. [DOI] [PubMed] [Google Scholar]
- 40.Reis A, Leite TM, Matte K, Michels R, Amaral RC, Geraldeli S, et al. Improving clinical retention of one-step self-etching adhesive systems with an additional hydrophobic adhesive layer. J Am Dent Assoc. 2009;140:877–85. doi: 10.14219/jada.archive.2009.0281. [DOI] [PubMed] [Google Scholar]
- 41.Ritter AV, Swift Jr EJ, Heymann HO, Sturdevant JR, Wilder AD., Jr An eight-year clinical evaluation of filled and unfilled one-bottle dental adhesives. J Am Dent Assoc. 2009;140:28–37. doi: 10.14219/jada.archive.2009.0015. [DOI] [PubMed] [Google Scholar]
- 42.Wilder AD, Jr, Swift EJ, Jr, Heymann HO, Ritter AV, Sturdevant JR, Bayne SC. A 12-year clinical evaluation of a three-step dentin adhesive in noncarious cervical lesions. J Am Dent Assoc. 2009;140:526–35. doi: 10.14219/jada.archive.2009.0220. [DOI] [PubMed] [Google Scholar]
- 43.Loguercio AD, Mânica D, Ferneda F, Zander-Grande C, Amaral R, Stanislawczuk R, et al. A randomized clinical evaluation of a one- and two-step self-etch adhesive over 24 months. Oper Dent. 2010;35:265–72. doi: 10.2341/09-241-C. [DOI] [PubMed] [Google Scholar]
- 44.Kubo S, Yokota H, Yokota H, Hayashi Y. Three-year clinical evaluation of a flowable and a hybrid resin composite in non-carious cervical lesions. J Dent. 2010;38:191–200. doi: 10.1016/j.jdent.2009.10.003. [DOI] [PubMed] [Google Scholar]
- 45.Yazici AR, Celik C, Ozgünaltay G, Dayangaç B. The effects of different light-curing units on the clinical performance of nanofilled composite resin restorations in non-carious cervical lesions: 3-year follow-up. J Adhes Dent. 2010;12:231–6. doi: 10.3290/j.jad.a17536. [DOI] [PubMed] [Google Scholar]
- 46.Heintze SD. Systematic reviews. I. Correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome. J Adhes Dent. 2007;9:77–106. [PubMed] [Google Scholar]
- 47.Hickel R, Roulte JF, Bayne S, Heintze SD, Mjor IA, Peters M, et al. Recommendations for conduction controlled clinical trials of dental restorative materials. Clin Oral Investig. 2007;11:5–33. doi: 10.1007/s00784-006-0095-7. [DOI] [PubMed] [Google Scholar]
- 48.Van Meerbeek B, Perdiaga˜o J, Lambrechts P, Vanherle G. The clinical performance of adhesives. J Dent. 1998;26:1–20. doi: 10.1016/s0300-5712(96)00070-x. [DOI] [PubMed] [Google Scholar]
- 49.Bayne SC, Heymann HO, Sturdevant JR, Wilder AD, Sluder TB. Contributing co-variables in clinical trials. Am J Dent. 1991;4:247–50. [PubMed] [Google Scholar]
- 50.Roberson TM, Heymann HO, Swift EJ. Sturdevants’ art and science of operative Dentistry. St Louis: Mosby: 2006. pp. 527–66. [Google Scholar]
- 51.Rueggeberg FA, Margeson DH. The effect of oxygen inhibition on an unfilled/filled composite system. J Dent Res. 1990;69:1652–8. doi: 10.1177/00220345900690100501. [DOI] [PubMed] [Google Scholar]
- 52.Loguercio AD, Loeblein F, Cherobin T, Ogliari F, Piva E, Reis A. Effect of solvent removal on adhesive properties of simplified etch-and-rinse systems and on bond strengths to dry and wet dentin. J Adhes Dent. 2009;11:213–9. [PubMed] [Google Scholar]
- 53.Pashley EL, Agee KA, Pashley DH, Tay FR. Effects of one vs two applications of unfilled, all-in-one adhesive on dentin bonding. J Dent. 2002;30:83–90. doi: 10.1016/s0300-5712(02)00002-7. [DOI] [PubMed] [Google Scholar]
- 54.Sidhu SK, Carrick TE, McCabe JF. Temperature mediated coefficient of dimensional change of dental tooth-colored restorative materials. Dent Mater. 2004;20:435–40. doi: 10.1016/j.dental.2003.02.001. [DOI] [PubMed] [Google Scholar]
- 55.Watanawongpitak N, Yoshikawa T, Burrow MF, Tagami J. the effect of bonding system and composite type on marginal adaptation of different C factor restoration. Dental Material J. 2006;25:45–50. doi: 10.4012/dmj.25.45. [DOI] [PubMed] [Google Scholar]
- 56.McCabe JF, Rusby S. Water sorption, dimensional change and radial pressure in resin matrix dental restorative material. Biomaterials. 2004;25:4001–7. doi: 10.1016/j.biomaterials.2003.10.088. [DOI] [PubMed] [Google Scholar]
- 57.Litonjuwa LA, Andreana S, Patra AK, Cohen RE. An assessment of stress analysis in the theory of abfraction. Biomed Mater Eng. 2004;14:311–21. [PubMed] [Google Scholar]
- 58.Frankenberger R, Tay FR. Self-etch vs etch-and-rinse adhesives: Effect of thermomechanical fatigue loading on marginal qulity of bonded resin restorations. Dent Mater. 2005;21:397–412. doi: 10.1016/j.dental.2004.07.005. [DOI] [PubMed] [Google Scholar]
- 59.Perdigão J, Dutra-Corrêa M, Castilhos N, Carmo AR, Anauate-Netto C, Cordeiro HJ, et al. One-year clinical performance of self-etch adhesives in posterior restorations. Am J Dent. 2007;20:125–33. [PubMed] [Google Scholar]
- 60.Perdigão J, Dutra-Corrêa M, Anauate-Netto C, Castilhos N, Carmo AR, Lewgoy HR, et al. Two-year clinical evaluation of self-etching adhesives in posterior restorations. J Adhes Dent. 2009;11:149–59. [PubMed] [Google Scholar]
- 61.Yoshida Y, Nagakane K, Fukuda R, Nakayama Y, Okazaki M, Shintani H, et al. Comparative study on adhesive performance of functional monomers. J Dent Res. 2004;83:454–8. doi: 10.1177/154405910408300604. [DOI] [PubMed] [Google Scholar]
- 62.Mjor IA, Toffenetti F. Secondary Caries: A literature review with case reports. Quintessence Int. 2000;31:165–79. [PubMed] [Google Scholar]
- 63.Kanemura N, Sano H, Tagami J. Tensile bond strength and SEM evaluation of ground and intact surface. J Dent. 1999;27:523–30. doi: 10.1016/s0300-5712(99)00008-1. [DOI] [PubMed] [Google Scholar]
- 64.Tay FR, Pashley DH, King NM, Carvalho RM, Lai SC, Marquenzini Jr L. Aggressiveness of self etch adhesives on unground enamel. Oper Dent. 2004;29:309–16. [PubMed] [Google Scholar]
- 65.Misra DN. Adsorption of 4-Methacryloxyethyl trimallitate anhydrite (4-META) on hydroxyapatite and its role in composite bonding. J Dent Res. 1989;68:42–7. doi: 10.1177/00220345890680010601. [DOI] [PubMed] [Google Scholar]
- 66.Kemp-Schlote CM, Davidson CL. Marginal integrity related to bond strength and strain capacity of composite resin restorative system. J Prosthet Dent. 1990;64:658–64. doi: 10.1016/0022-3913(90)90291-j. [DOI] [PubMed] [Google Scholar]
- 67.Perdigão J, Lopes M, Geraldeli S, Lopes GC, Garcia-Godoy F. Effect of a sodium hypochlorite gel on dentin bonding. Dent Mater. 2000;16:311–23. doi: 10.1016/s0109-5641(00)00021-x. [DOI] [PubMed] [Google Scholar]
- 68.Hashimoto M, Sano H, Yoshida E, Hori M, Kaga M, Oguchi H, et al. Effects of multiple adhesive coatings on dentin bonding. Oper Dent. 2004;29:416–23. [PubMed] [Google Scholar]
- 69.Choi KK, Condon JR, Ferracane JL. The effects of adhesive thickness on polymerization contraction stress of composite. J Dent Res. 2000;79:812–7. doi: 10.1177/00220345000790030501. [DOI] [PubMed] [Google Scholar]
- 70.Koike T, Hasegawa T, Itoh K, Yukitani W, Yamashita T, Wakumoto S, et al. Effect of multiple application of a dentin adhesive on contraction gap width of a resin-based composite. Am J Dent. 2002;15:159–63. [PubMed] [Google Scholar]
