Abstract
A new sensitive, simple, rapid and precise method for simultaneous estimation of paracetamol and aceclofenac in combined tablet dosage form has been developed. The method is based on ratio derivative spectrophotometry. The amplitude in first derivative of the ratio spectra at 256 nm and 268 nm (minima) were selected to determine paracetamol and aceclofenac in combined formulation. The method showed good linearity, accuracy and reproducibility. Results of analysis were validated statistically and by recovery studies.
Keywords: Aceclofenac, paracetamol, ratio spectra derivative spectroscopy
Aceclofenac (AFC) is {o-(2,6-dichloroanilino)phenyl}acetate glycolic acid ester with antiinflammatory and analgesic properties1. Paracetamol (PAR) chemically is 4-hydroxy acetanilide2. Several analytical methods are reported for determination of AFC and PAR in bulk and pharmaceutical dosage formulations as a single component as well as in combination with other drugs. Recently UV spectrophotometric method for simultaneous estimation of aceclofenac and paracetamol in a combined tablet dosage form has been reported3. Extensive literature survey revealed that no method is available for simultaneous estimation of AFC and PAR in combined dosage form by ratio spectra derivative spectroscopy4–6. Aim of present work was to develop simple, economical, reproducible and rapid method for simultaneous estimation of binary drug formulation.
The instrument used in the present study was JASCO double beam UV/Vis spectrophotometer (Model UV-530) with fixed slit width 2 nm connected to a computer with spectra manager software. All weighing were done on electronic balance (Shimadzu AY 120). AFC and PAR were obtained from Concept Pharmaceuticals Pvt. Ltd. and Cipla Ltd., respectively, which were used as such without further purification. All chemicals used in spectrophotometric analysis were of analytical grade. Tablets of Aceroc-P (Wockhardt Ltd.) labeled to contain AFC 100 mg and PAR 500 mg were procured from the local market.
Standard stock solution was prepared by dissolving 50 mg of PAR and AFC separately in 50 ml of methanol to get concentration of 1 mg/ml. Ten ml of stock solutions were further diluted to 100 ml with phosphate buffer (pH-7, prepared as per IP) to get a working standard solution of concentration 100 μg/ml of each drug. For commercial formulation analysis twenty tablets were weighed accurately and powdered. Powder equivalent to 50 mg of PAR was weighed and transferred to 50 ml volumetric flask; in the same flask 40 mg of pure AFC drug was added and dissolved in methanol by shaking the flask for 10 min. The solution was filtered through Whatman filter paper No. 41 and first few ml were rejected. 10 ml of this filtrate was further diluted to 100 ml with phosphate buffer pH-7. Two millilitres of this solution was further diluted to 10 ml to get final concentration of 20 μg/ml of each drug. Spectra was recorded and processed separately to determine concentration of each drug.
Salinas et al7developed a ratio spectra derivative spectroscopic method based on dividing the spectrum for a mixture into the standard spectra for each of the analyses and driving the quotient to obtain a spectrum that is independent of the analyte concentration used as a divisor. The use of standardized spectra as divisors minimizes experimental errors and background noise. Easy measurements on separate peaks, higher values of the analytical signals and no need to work only at zero-crossing points (sometimes co-existing compounds have no maximum or minimum at these wavelengths) are advantages for ratio spectra derivative spectrophotometry in comparison with the zero-crossing derivative spectrophotometry. Also, the presence of a lot of maxima and minima in ratio spectra derivative data was another advantage, since these wavelengths give an opportunity for the determination of these compounds in the presence of other active compounds and excipients that possibly interfered with the assay. Using appropriate dilutions of standard stock solution the two solutions were scanned separately. The ratio spectra of different AFC standards at increasing concentrations was obtained by dividing each with the stored spectrum of the standard solution of PAR (30 μg/ml) by computer aid are shown in fig. 1 (a) and the first derivative of these spectra traced with the interval of Δλ= 13 nm (the influence of Δλ for the first derivative of the ratio spectra was tested to obtain the optimum wavelength interval, Δλ= 13 nm was considered to be suitable) are illustrated in fig. 1 (b). Wavelength 268 nm (minima) was selected for the quantification of AFC in AFC+PAR mixture. The ratio and ratio derivative spectra of the solutions of PAR at different concentrations traced with the interval of Δλ= 13 nm by using the standard spectrum of AFC (10 μg/ml) as divisor by computer aid are demonstrated in fig. 2 (a) and (b), respectively. Wavelength 256 nm (maxima) was selected for the quantification of PAR in AFC+PAR mixture. Measured analytical signals at these wavelengths were proportional to the concentrations of these drugs.
Under experimental conditions described linearity was found in the range 10-50 μg/ml with high correlation coefficients for both the drugs. Six replicate readings of drug solution were taken to study the precision of method.% RSD was found to be less than 1.5, indicating reproducibility. For recovery study different volumes of standard solution was added to the fixed volume of sample solution. The total amount of drug added was determined by proposed method. Results of recovery studies are shown in Table 1.
TABLE 1.
Level of % Recovery | % Mean Recovery* | Standard Deviation | % RSD | Standard Error | ||||
---|---|---|---|---|---|---|---|---|
AFC | PAR | AFC | PAR | AFC | PAR | AFC | PAR | |
50 | 100.1 | 100.06 | 0.0866 | 0.07637 | 0.0865 | 0.0763 | 0.0499 | 0.044 |
100 | 100.05 | 99.97 | 0.0854 | 0.08326 | 0.0853 | 0.0832 | 0.0493 | 0.048 |
150 | 99.756 | 99.986 | 0.4045 | 0.12055 | 0.4054 | 0.1205 | 0.2335 | 0.0395 |
Average of three determinations, RSD is relative standard deviation
Acknowledgments
The authors thank the Concept Pharmaceutical Pvt. Ltd., Aurangabad and Cipla Ltd., Mumbai for providing gift sample of ACF and PAR respectively. Thanks are also due to the principal, Dr. K. G. Bothara, for providing infrastructure facilities.
Footnotes
Gandhi, et al.: Spectroscopic estimation of Paracetamol and Aceclofenac
REFERENCES
- 1.Reynolds JE, Prasad BA. Martindale – The Extra Pharmacopoeia. 30th ed. London: The Pharmaceutical Press; 1993. p. 2. [Google Scholar]
- 2.British Pharmacopoeia. International ed. Vol. I. London: HMSO Publication; 1993. British Pharmacopoeial Commission; p. 483. [Google Scholar]
- 3.Nikam AD, Pawar SS, Gandhi SV. Simultaneous spectrophotometric estimation of aceclofenac and Paracetamol. Asian J Chem. 2007;19:5075–80. [Google Scholar]
- 4.Dinc E. The spectrophotometric multicomponent analysis of ternary mixture of ascorbic acid, acetyl salicylic acid and paracetamol by double divisor ratio spectra derivative and ratio spectra zero crossing method. Talanta. 1999;48:1945–57. doi: 10.1016/s0039-9140(98)00337-3. [DOI] [PubMed] [Google Scholar]
- 5.Erk N. Comparison of spectrophotometric and an LC method for the determination perindropil and indapamide in pharmaceutical formulations. J Pharm Biomed Anal. 2001;26:43–52. doi: 10.1016/s0731-7085(01)00388-0. [DOI] [PubMed] [Google Scholar]
- 6.Abdel AY, Sayed El, Najeb A, Salem El. Recent development of derivative spectrophotometry and their analytical applications. Anal Sci. 2005;21:595–600. doi: 10.2116/analsci.21.595. [DOI] [PubMed] [Google Scholar]
- 7.Salinas F, Berzas-Nevado JJ, Espinosa MA. A new spectrophotometric method for quantitative multicomponent analysis resolution of mixtures of salicylic and salicyluric acids. Talanta. 1990;37:347–51. doi: 10.1016/0039-9140(90)80065-n. [DOI] [PubMed] [Google Scholar]