. 2010 Sep-Dec;14(3):71–77. doi: 10.4103/0019-5278.75693

Modeling of hexamethylene diisocyanate and psychrometric parameters and other effective factors in the polyurethane factories

Mirtaghi Mirmohammadi 1,, M H Ibrahim 1, J N Saraji 1
PMCID: PMC3062018  PMID: 21461158

Abstract

Background:

Diisocyanates are widely used in surface coatings, polyurethane (PUR) foams, adhesives, resins, elastomers, binders, and sealants. Isocyanate exposure is irritative to the skin, mucous membranes, eyes, and respiratory tract. The most common adverse health outcome associated with isocyanate exposure is asthma due to sensitization.

Objective:

The goal of this study is to find statistical predictive model to determine the relationship between airborne hexamethylene diisocyanate (HDI) and selective psychrometric variables.

Materials and Methods:

All air samplers (by midget impinger) were collected by mini personal sampler pump fixed to work stations near the source of pollution. The air samples and psychrometric parameters were separately collected and determined in a working shift for three periods of 2 h, each at a flow rate of 2 l/min in an impinger containing a solution of reagent of dimethyl sulfoxide in tryptamine [US National Instituteof Occupational Safety and Health (NIOSH), 1994].

Results:

There was a significant correlation between HDI concentration and relative humidity and dry bulb temperature (P < 0.05). No significant correlation was seen between altitude and dimension of PUR factories (P > 0.05).

Conclusions:

The finding of the study may be a useful initial tool in estimating possible HDI pollution situation in the PUR workplaces, based on simple psychrometric factors (indoor air temperature and relative humidity).

Keywords: Diisocyanate, dry bulb temperature, hexamethylene diisocyanate concentration, regression, relative humidity

INTRODUCTION

Nowadays, the modern work style in the industries has brought into use all the chemical materials and high toxic materials in production process. Use of chemical materials in the workplace causes indoor air pollution problems. Aromatic diisocyanates such as methylene diphenyl diisocyanate (HDI) are extensively used in the manufacture of polyurethane (PUR) products.[1] The main PUR products are flexible and rigid foam; other applications are as adhesives, sealants, binders, surface coatings and more. The global production of diisocyanates is annually increasing. In Europe alone, it is estimated that over 70,000 employees are manufacturing isocyanates or PUR.[2] The numbers of workers further processing the PUR products are not known. The exposure to isocyanates is complex and different in different applications. The lower molecular weight isocyanates tend to volatilize at room temperature, creating a vapor inhalation hazard. Conversely, the higher molecular weight isocyanates do not readily volatilize at ambient temperatures, but are still an inhalation hazard if aerosolized or heated in the work environment. The latter is important since many reactions involving isocyanates are exothermic in nature, thus providing the heat for volatilization.[3] As exposure limits decrease, the volatility of solid materials becomes an issue. To reduce the vapor hazards associated with the lower molecular weight diisocyanates, prepolymer and polyisocyanate forms of these diisocyanates were developed and have replaced the monomers in many product formulations. An example is HDI, which consists of three molecules of HDI monomer joined together to form a higher molecular weight oligomer having similar characteristics to those found in the monomer.[4] The specific goal of this study is to answer the following question: How does the HDI concentration change with respect to psychrometric and factory factors?

The correlation and regression analysis techniques are useful in investigating these relationships. The relationship between meteorological parameters and pollutant concentrations has been well studied in different parts of the world for different time periods. A lot of research has been devoted to the study of the local climatic conditions in relation to the air quality. Dickson, for example, studied the relationship between precipitation and particulate matter in Nashville, whereas Sham used a linear correlation to model respirable dust particulate and average wind speed in Malaysia.

MATERIALS AND METHODS

Of the PUR factories, 5 HDI factories were selected which had 450 workers, for this study; all of them manufactured foaming or PUR foams. The predominantly used isocyanate was HDI. There were 200 unexposed workers who worked in the office area. The sampling and analysis of isocyanates are divided into four steps: collection, derivatization, sample preparation and identification.[5] The samplers have been evaluated for aspiration efficiencies and internal losses. All of the samplers with midget impinger were connected to mini personal sampler pump fixed to workstations near the source of pollution. The air sample was collected for 2 h at a flow rate of 2 l/min, in the impinger containing a solution of reagent of dimethyl sulfoxide (DMSO) in tryptamine. Because DMSO is readily absorbed through the skin, US National Instituteof Occupational Safety and Health (NIOSH) recommends that DMSO impingers be used for area air sampling only. Reversed-phase high performance liquid chromatography (HPLC) has been the dominant separation technique used in isocyanate analysis.[6] The first step in the analysis of a solution is derivatization of isocyanates for the separation through HPLC, for their qualitative as well as quantitative analysis.[7] Air sampling was performed according to NIOSH method 5522 for isocyanate in air. Air samples were collectedat a flow rate of 2 l/min using a midget impinger sampler (SKC, Eighty Four, PA, USA) and personal sampling pumps were calibratedbefore and after sampling with a Dry Cal DC-Lite primary flow meter(Bios International Co., Pompton Plains, NJ, USA). A KNAUER HPLC was used for air analysis. The HPLC equipment consisted of a high-pressure pump, a variable-wavelength UV detector and a loop injector; HPLC columns were made of stainless steel (200 mm long × 5 mm in inside diameter) packed with 5 m Nucleosil C18. The air concentrations of HDI were monitored continuously by the midget impinger instrument using DMSO with tryptamine reagent and the sampling time for HPLC analyses was 1 h at an air flow rate of 2 l/min.

During air sampling for HDI concentration inside the factories, data for indoor relative humidity, indoor dry bulb temperature, altitude and dimension of factory were recorded. HDI was considered as a dependent variable and the rest were independent variables. These independent indoor air variables were divided into two groups. One was the indoor air psychrometric parameters involving the relative humidity (Rh, %) and the dry bulb temperature (Td, °C). The other group was the factory parameters involving the factory dimension in terms of factory space (D, m3) and the altitude of factory location (Alt, m).

Regression analysis procedure was used to state the statistical relationship between the variables and identify any meaningful relationship between those variables. Due to the fact that the number of independent was variables more than one, multiple linear regression analysis was used in the present analysis.[8] A multiple regression equation, which has four independent variables, was used, and it can be expressed as follows:

Y=B0+B1X1+B2X2+B3X3+B4X4+ei (1)

where

Y is the dependent variable (HDI concentration),

X1, X2, X3 and X4 are independent variables (relative humidity, dry bulb temperature, factory dimension and altitude) as the predictors in this model,

B0, B1, B2, B3 and B4 are the model coefficients, and ei is the residual error.

The values for the constant and the coefficients are determined using the least-squares method which minimizes the error as “e” in the above regression equation. The significance levels of the constant and coefficients are statistically tested using t-distribution. The R2 (coefficient of determination) determines the direction and significance level of relation between the variables in the mathematical model and shows how much the dependent variable is affected by the independent variables.

All statistical analyses were performed using SPSS software, version 16. In this study, the alpha level was 0.05 (P ≤ 0.05), which was similar to other indoor air pollution studies.[911]

RESULTS

Table 1 shows the maximum, minimum and mean values of indoor air independent variables with respect to HDI concentration in the PUR factories for 100 air samples which were gathered from workplaces separately by static sampling procedure. The lowest minimum HDI concentration in all the factories was 61 µg/m3 and also the highest of the maximum HDI concentration was 96 µg/m3. These values can be considered as high, when compared to NIOSH exposure limit of 35 µg/m3. The mean HDI concentration was 78.8 µg/m3, the mean indoor relative humidity was 37.7%, and the mean dry bulb temperature was 28.3°C. The size of workplace for the five PUR factories ranged from 5000 to 9800 m3 and the altitude of factories was from as low as 22 m to as high as 1200 m.

Table 1.

Values of indoor air variables in the HDI polyurethane factories

Variables Factory codes
Average
H1 H2 H3 H4 H5
HDI concentration (µg/m3), max 96 92 90 90 88 91.2
Min 67 66 66 64 61 64.8
Mean 82.2 79.8 78.7 77 76.7 78.8
Relative humidity (%), max 52 52 45 45 40 46.8
Min 32 31 31 31 31 31.2
Mean 40.5 40 37 37 34 37.7
Dry bulb temperature (°C), max 33 32 32 32 30 31.8
Min 25 24 24 24 23 24
Mean 29.3 27.8 28.7 28.7 27.1 28.3
Dimension of factory (m3) 5000 6100 7400 9000 9800 7460
Altitude (m) 1200 1200 1100 890 22 882

Max: maximum, min: minimum, NIOSH guideline value: 35(µg/m3)

It has been summarized and stated in Table 1 that several factories show variable concentration of diisocyanates, with respect to relative humidities of each factory. The highest mean value HDI concentration was 82.2 µg/m3 which corresponds to the highest mean relative humidity of 40.5% inside factory H1. Factories H1 and H2 were located in Tehran province. Factory H2 had the second highest mean HDI concentration and also the second highest mean relative humidity (79.8 µg/m3 and 40%, respectively). Factory H5 had the lowest mean value HDI concentration which was 76.7 µg/m3. Factory H5 was situated in Mazandaran province and this factory had the lowest mean relative humidity of 34%.

Table 1 also summarizes that several factories have variable concentration of diisocyanates with respect to different dry bulb temperature. In factory H1,the highest mean HDI concentration was 82.2 µg/m3 and this corresponds to the highest mean dry bulb temperature of 29.3°C. Similarly, in factory H5, the lowest mean HDI concentration was 76.7 µg/m3 which corresponds to the lowest mean dry bulb temperature 27.1°C.

Multiple linear regression analyses

Multiple regression analyses were performed to determine the psychrometric variables and other factors that explained the most variance in the overall data. The results of application of correlation coefficients and regression analysis are listed in Tables 2 and 3.

Table 2.

Correlation result for HDI concentration and psychrometric parameters and factory parameters

HDI (µg/m3) RH (%) Td (°C) D (m3) Alt (m)
HDI (µg/m3) Pearson Correlation 1 0.739 0.88 -0.887 0.85
Sig. (2-tailed) . 0.0001 0.0001 0.0001 0.0001
N 100 100 100 100 100
RH (%) Pearson Correlation 0.739 1 0.639 -0.687 0.744
Sig. (2-tailed) 0.0001 . 0.0001 0.0001 0.0001
N 100 100 100 100 100
Td (°C) Pearson Correlation 0.88 0.639 1 -0.963 0.719
Sig. (2-tailed) 0.0001 0.0001 . 0.0001 0.001
N 100 100 100 100 100
D (m3) Pearson Correlation -0.887 -0.687 -0.963 1 -0.812
Sig. (2-tailed) 0.0001 0.0001 0.0001 . 0.0001
N 100 100 100 100 100
Alt (m) Pearson Correlation 0.85 0.744 0.719 -0.812 1
Sig. (2-tailed) 0.0001 0.0001 0.0001 0.0001 .
N 100 100 100 100 100

Correlation is significant at the 0.05 level (2-tailed).

Table 3.

Regression model summary of HDI

Model r R2 Adjusted r2
0.915 0.837 0.83

Predictors: (constant), altitude (m), dimension of factory (m3), relative humidity (%), dry bulb temperature (°C)

Relative humidity

From Table 2, it is seen that relative humidity also correlates positively with HDI concentration. A significant relationship was found between HDI concentration and relative humidity in the PUR factories. The relative humidity in the study area was more than 34% on the average. Therefore, higher relative humidity corresponds to a greater concentration level of HDI in the PUR factories.

Dry bulb temperature

A correlation between HDI concentration and dry bulb temperature yields a significant positive relationship. This implies that increased dry bulb temperature in the workplaces corresponds to high levels of HDI concentration.

Dimension of workplace

No correlation was seen between HDI concentration and dimension of workplaces. The correlation coefficient, however, is less and statistically not significant at 0.142 level, but negative.

Altitude

The correlation between HDI concentration and altitude did not show any relationship. No significant relationship was found between HDI concentration and altitude.

The results imply that all or some of parameters (altitude, dimension of factory, relative humidity and dry bulb temperature) can be significant predictors of HDI concentration in the PUR workplaces.

Table 4 presents an analysis of variance for HDI concentration in the PUR factories. From the table, it can be seen that F is 121.9 which is significant at P < 0.05. We can conclude that the regression model predicts the concentration level of HDI significantly well.

Table 4.

Regression model for HDI polyurethane factories’ factors

Model Mean square F P value
Regression 1155.895 121.934 0.0001
Residual 9.48
Total 0

Predictors: (constant), altitude (m), dimension of factory (m3), relative humidity (%), dry bulb temperature (°C), dependent Variable: HDI concentration (µg/m3)

Since the results of regression model test in Table 4 illustrate that the independent variables are significant predictors of HDI concentration, we can employ equation (1) to stand for the different psychrometric and factory parameters in order to measure the predictive regression correlation between the parameters and HDI concentration.

Table 5 shows the results of regression analysis between HDI concentration and PUR indoor air parameters. Both indoor relative humidity and dry bulb temperature can be seen to be significant predictors of HDI pollution (P < 0.05). Both these parameters fall under the psychrometric parameters group. The other two parameters (factory dimension and altitude) are the factory parameters and both are not significant (P > 0.05). This means that the size of HDI PUR factories and geographical positions of the factories in terms of altitude are not significant where the HDI pollution is concerned and are therefore taken out from the regression model.

Table 5.

Result of regression analysis between HDI concentration and polyurethane indoor air parameters

Model Coefficients
T P value
B SE
(Constant) 43.267 17.837 2.426 0.017
Relative humidity (%) 0.367 0.071 5.182 0.0001
Dry bulb temperature (°C) 1.112 0.399 2.785 0.006
Dimension of factory (m3) –0.001 0.001 –1.479 0.142
Altitude (m) 0.003 0.002 1.475 0.144

Dependent Variable: HDI concentration (µg/m3)

The independent variables (relative humidity and dry bulb temperature) were reproduced for the model to find the regression coefficients for HDI pollution in the PUR factories. The coefficients with respect to the constant, relative humidity and the dry bulb temperature as well as the collinearity statistics are shown in Table 6.

Table 6.

The collinearity statistical model coefficients

Model Coefficients
t P value Collinearity statistics
B SE Tolerance VIF
(Constant) 27.771 2.638 10.528 0.0001
Relative humidity (%) 0.368 0.067 5.454 0.0001 0.592 1.689
Dry bulb temperature (°C) 1.492 0.119 12.588 0.0001 0.592 1.689

Dependent variable: HDI concentration (µg/m3)

Collinearity diagnostics was used in this study to find multicollinearity between dependent (HDI concentration) and independent variables (relative humidity and dry bulb temperature). Multicollinearity here refers to linear intercorrelation among psychrometric variables. If psychrometric variables (relative humidity, dry bulb temperature) correlate highly, they are redundant in the same model. The best regression models are those in which the each of the predictor variables correlate highly with the dependent (outcome) variable but correlate at most only minimally with each other.[12]

The two factory predictor variables (dimension of factory and altitude) were not found to be significant in the model. They were eliminated for making a new regression model based on relative humidity and dry bulb temperature. By replacing Y, X1 and X2 with HDI, Rh (relative humidity) and Td (dry bulb temperature), respectively, and eliminating X3 (factory dimension) and X4 (altitude) and also substituting the relevant coefficients from Table 6, equation (1) can be written as follows:

HDI=27.77+0.368Rh+1.492Td (2)

Equation (2) implies that relative humidity and dry bulb temperature affect diisocyanates pollutant concentration in the workplaces. The background HDI concentration was about 27.77 µg/m3, as indicated by the value of the constant in the regression equation.

Figure 1 shows the relationship between HDI concentration and psychrometric parameters (relative humidity and dry bulb temperature) in five PUR factories based on equation (2).

Figure 1.

Figure 1

Relationship between HDI concentration and psychrometric parameters (relative humidity and dry bulb temperature)

Both indoor air relative humidity and dry bulb temperature significantly contribute to the variability of the HDI concentration (R2 = 0.837) and both factors also show a straight positive relationship with the HDI concentration. This means that as the indoor relative humidity or the dry bulb temperature increases, the HDI concentration also increases. Equation (2) (also shown in Figure 1) suggests that the average background HDI concentration was about 27.77 µg/m3, as indicated by the value of the constant in the regression equation.

DISCUSSION

A positive relationship between temperature and HDI concentration can be expected as it was reported in the literature,[13] where an exponential increase of isocyanate emission rate was observed during curing of PUR adhesives. It was seen that in the range of typical room temperatures (20–30°C) there was only small effect on emission. However, at temperatures greater than 40°C, a clear increase in emission was noticed. The indoor temperatures within the factories ranged from 23 to 33°C. The linear relationship between temperature and HDI concentration is acceptable since the indoor temperatures were not greater than 40°C where exponential increase of isocyanate emission could occur. Vilhelm has found that dry bulb temperature affects diisocyanates pollutant generation speed and the volatility of the isocyanates emission into workplaces. They reported that the speed of the reaction also depends a great deal on temperature.[14]

As for the effects of relative humidity on isocyanate concentration, Ludwig and Urban observed that reactions of isocyanate groups with OH groups during cross-linking are inversely proportional to the relative humidity of the environment. They explained that the presence of competing reactions between water and isocyanate hinders the degree of cross-linking between them. Abram and Bowler studied the effect of relative humidity on the curing and dielectric properties of the PUR-based composites. They found that a PUR factory at 87% relative humidity gave more noticeable effect as compared to one at 37.7% RH. The electromagnetic properties of the polyurea/PUR-based composites studied were found to be strongly influenced by the presence of water vapor during the curing process, as evidenced by the significant difference in the real relative permittivity of samples cured in different RH environments.[15] This difference was caused primarily by water uptake into the polymer matrix. The RH alters the dielectric properties of the composite material due to its strong polar nature and high value of real relative permittivity. In this study, the RH was in the range of 31–52%. The working range for RH in this study is lower than that reported by Abram and Bowler for the noticeable effects (87% RH). Hence, the effect of RH is expected to be not as significant as to the effects of temperature.[16]

The relationship between psychrometric factors such as indoor temperature and relative humidity was extracted from some normal gas emission behavior in the workplaces and the relationship depended on the gas phase reaction of isocyanates.[17]

The mean isocyanate concentration in this study was 78.87 µg/m3 (0.079 mg/m3). This is comparable to an investigation conducted in southern Australian auto body shops, which reported a geometric mean concentration of 0.07 mg/m3 isocyanates (range <0.01–3.5 mg/m3 NCO).[18] Swedish auto body shops’ exposures during spray paintingshowed higher values between 0.26 and 1.1 mg/m3.[19] A survey of Oregon auto body shops measureda geometric mean concentration of 0.35 mg/m3 isocyanate with a maximumof 4 mg/m3 isocyanate.[20] Maître et al. have reportedan arithmetic mean level of 0.33 mg/m3 isocyanate (range 0.05–0.65 mg/m3) in a French isocyanates spray factory. These findings suggest that the measurements in this research are comparable to other related literatures.[21] However, comparison of such results is quite difficult because the sampling time, sampling method and manufacturing process were totally different.[22]

Heitbrink et al. studied psychrometric factors and diisocyanates in different PUR factories. They stated that there is a relationship between high concentration of diisocyanates andexposures for workers.[23] In general, direct comparison of the results of present study with those of previous studies is quite difficult. Woskie et al. observed a number of reasons for this, such as often the sampling times are quite different, the results were described with a variety of descriptive statistics (arithmetic means, geometric means, etc.), the aims of the studies varied greatly (sampler comparisons, method evaluations, surveillance and epidemiology) and the studies were conducted in different countries, covering different periods.[24] Furthermore, in such studies, many different materials were used as calibration for standards and different units were used to express the exposure concentrations.

The psychrometric regression model obtained in this study was the same as that of dust correlation study performed in Malaysia[25] and almost close to that of PUR factories.[24]

The relationship between psychrometric factors such as indoor temperature, relative humidity and altitude was extracted from some normal gas emission behavior in the workplaces where it depended on the gas phase reaction of isocyanates.[16] The results from psychrometric factors and diisocyanates in this study indicated a strong dependence of emission rates on indoor temperature and diisocyanates and this result was the same as that of other studies conducted in different geographical places in Germany, in the current study, for at the result of this study showed diisocyanates had a negative relationship to altitude (based on gas law, altitude has a reverse relation with air pressure. This can be ascribed to the higher volatility of isocyanate pointed to this relationship as well.[8,26,27]

CONCLUSIONS

The results of indoor air monitoring in all the five Iranian PUR factories showed high HDI concentration values, in comparison with NIOSH exposure limit of 35 µg/m3. The HDI concentration ranged from 62.24 to 92.7 µg/m3 with a mean HDI concentration of 78.8 µg/m3.

Both indoor air relative humidity and temperature significantly contribute to the variability of the HDI concentration (R2 = 0.837) and both factors also showed a straight relationship with the HDI concentration. The size of factories and altitude at which the factories were located did not seem to be significant predictors of HDI concentration level in the factories. Multiple linear regressions were used to relate relative humidity and indoor air temperature to HDI, according to equation (2) as follows:

HDI=27.77+0.37Rh+1.49Td (2)

The background HDI concentration was about 27.77 µg/m3, as indicated by the value of the constant in the regression equation.

The current work admittedly has limitations but may be a useful initial tool in estimating possible HDI pollution situation in the PUR workplaces, based on simple psychrometric factors (indoor air temperature and relative humidity). It can serve as a basis of future evaluation and intervention efforts to reduce the workers to isocyanate exposure.

Acknowledgments

The authors gratefully acknowledge the technical and financial support provided by Iranian Ministry of Health and Medical Education, Medical University of Mazandaran and University Science Malaysia.

Footnotes

Source of Support: Iranian Ministry of Health and Medical Education, Medical University of Mazandaran and University Science Malaysia.

Conflict of Interest: None declared

REFERENCES

  • 1.Harris AT, Davidson JF, Thorpe RB. A novel method for measuring the residence time distribution in short time scale particulate systems. Chem Eng J. 2002;89:127–42. [Google Scholar]
  • 2.Bello D, Streicher RP, Woskie SR. Evaluation of the NIOSH draft method 5525 for determination of the total reactive isocyanate group (Trig) for Aliphatic Isocyanates in auto body repair shops. J Environ Med. 2002;4:351–60. doi: 10.1039/b110613a. [DOI] [PubMed] [Google Scholar]
  • 3.Alshibli KA, Sture S. Sand shear band thickness measurements by digital imaging techniques. J Comput Civil Eng. 1999;13:103–8. [Google Scholar]
  • 4.NIOSH. Determination of airborne isocyanate exposure (1994). Chapter K. NIOSH manual of analytical methods. 4th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS, Publication No; pp. 94–113. [Google Scholar]
  • 5.Roemmelt H, Fruhmann G. Respiratory and other hazards of isocyanates. Int Arch Occup Environ Health. 1994;66:141–52. doi: 10.1007/BF00380772. [DOI] [PubMed] [Google Scholar]
  • 6.White J. MDHS 25 Revisited; Development of MDHS 25/3, the Determination of Organic Isocyanates in Air. Ann Occup Hyg. 2006;50:15–27. doi: 10.1093/annhyg/mei036. [DOI] [PubMed] [Google Scholar]
  • 7.Tinnerberg H, Sennbro C. Assessment of exposure to aromatic diisocyanates air or biological monitoring. IOHA 2005 Pilanesberg: Paper G1-4. 2005 [Google Scholar]
  • 8.Bahattin M, İbrahim K. The relation between meteorological factors and pollutants concentrations in Karabük City. G.U. J Sci. 2007;20:87–95. [Google Scholar]
  • 9.Marek W, Potthast J, Marczynski B, Mensing T, Baur X. Subchronic exposure to diisocyanates increases guinea pig tracheal smooth muscle responses to acetylcholine. Respiration. 1999;66:156–61. doi: 10.1159/000029358. [DOI] [PubMed] [Google Scholar]
  • 10.Molander P, Levin JO, Ostin A. Harmonized nordic strategies for isocyanate monitoring in workroom atmospheres. J Environ Monit. 2002;4:685–7. doi: 10.1039/b203393c. [DOI] [PubMed] [Google Scholar]
  • 11.Dalene Determination of airborne isocyanates as di-n-butylamine derivatives using liquid chromatography and tandem mass spectrometry. Analytica Chimica Acta. 2004;534:263–9. [Google Scholar]
  • 12.Wiley Encyclopedia of biostatistics. Available from: http://www.wiley.com/legacy/wileychi/eob/publicity.html [last cited on 2009]
  • 13.Wirts M, Grunwald D, Schulze D, Uhde E, Salthammer T. Time course of isocyanate emission from curing polyurethane adhesives. Atmos Environ. 2003;37:5467–75. [Google Scholar]
  • 14.Vilhelm, Jan. (2001) Isocyanates. Risk assessment and preventive measures. Meeting of the Nordic supervisory authorities in Copenhagen on 27 April 2000 [Google Scholar]
  • 15.Ludwig BW, Urban MW. Quantitative determination of isocyanate concentration in crosslinked polyurethane coatings. The Journal of Coatings Technology. Available from: http://www.superiortire.com [last cited on 1996]
  • 16.Abram ER, Bowler N. Effect of relative humidity on the curing and dielectric properties of polyurethane-based composites. This paper appears in: Electrical Insulation and Dielectric Phenomena, 2005. CEIDP ’05. 2005 Annual Report Conference on Publication Date: 16-19 Oct. 2005 [Google Scholar]
  • 17.Holdren MW, Spicer CW, Riggin RM. Gas phase reaction of toluene diisocyanate with water vapor. Am Ind Hyg Assoc J. 1984;45:626–33. [Google Scholar]
  • 18.Pisaniello DL, Muriale L. The use of isocyanate paints in auto refinishing: A survey of isocyanate exposures and related work practices in South Australia. Ann Occup Hyg. 1989;33:563–72. doi: 10.1093/annhyg/33.4.563. [DOI] [PubMed] [Google Scholar]
  • 19.Torling G, Alexandersson R, Hedenstierna G, Plato N. Decreased lung function and exposure to diisocyanates (HDI and HDI-BT) in car repair painters: Observations on re-examination 6 years after initial study. Am J Ind Med. 1990;17:299–310. doi: 10.1002/ajim.4700170302. [DOI] [PubMed] [Google Scholar]
  • 20.Janko M, McCarthy K, Fajer M, van Raalte J. Occupational exposure to 1, 6-hexamethylene diisocyanate-based polyisocyanates in the State of Oregon, 1980-1990. Am Ind Hyg Assoc J. 1992;53:331–8. doi: 10.1080/15298669291359735. [DOI] [PubMed] [Google Scholar]
  • 21.Maitre A, Berode M, Perdrix A, Stoklov M, Mallion JM, Savolainen H. Urinary hexane diamine as an indicator of occupational exposure to hexamethylene diisocyanate. Int Arch Occup Environ Health. 1996;69:65–8. doi: 10.1007/BF02630741. [DOI] [PubMed] [Google Scholar]
  • 22.Maitre A, Leplay A, Perdrix A, Ohl G, Boinay P, Romazini S, et al. Comparison between solid sampler and impinger for evaluation of occupational exposure to 1,6-hexamethylene diisocyanate polyisocyanates during spray painting. AIHA J. 1993;57:153–60. [Google Scholar]
  • 23.Heitbrink WA, Wallace ME, Bryant CJ, Ruch WE. Control of paint overspray in autobody repair shops. Am Ind Hyg Assoc J. 1995;56:1023–32. doi: 10.1080/15428119591016467. [DOI] [PubMed] [Google Scholar]
  • 24.Woskie SR, Sparer J, Gore RJ, Stowe M, Bello D, Liu Y, et al. Determinants of isocyanate exposures in auto body repair and refinishing shops. Ann Occup Hyg. 2004;48:393–403. doi: 10.1093/annhyg/meh021. [DOI] [PubMed] [Google Scholar]
  • 25.Yassen ME. Analysis of climatic conditions and air quality observations in Kuala Lumpur and Petaling Jaya, Malaysia, during 1983-1997. MPhil Thesis. 2000 [Google Scholar]
  • 26.Sánchez-Ccoyllo OR, de F. The influence of meteorological conditions on the behavior of pollutants concentrations in Sao Paulo, Brazil. Environ Pollut. 2002;116:257–63. doi: 10.1016/s0269-7491(01)00129-4. [DOI] [PubMed] [Google Scholar]
  • 27.Cuhadaroglu B, Demirci E. Influence of some meteorological factors on air pollution in Trabzon city. Energy Buildings. 1997;25:179–84. [Google Scholar]

Articles from Indian Journal of Occupational and Environmental Medicine are provided here courtesy of Wolters Kluwer -- Medknow Publications

RESOURCES