Abstract
Background
Serum is an ideal source of biomarker discovery and proteomic profiling studies are continuously pursued on serum samples. However, serum is featured by high level of protein glycosylations that often cause ionization suppression and confound accurate quantification analysis by mass spectrometry. Here we investigated the effect of N-glycan and sialic acid removal from serum proteins on the performance of label-free quantification results.
Results
Serum tryptic digests with or without deglycosylation treatment were analyzed by LC-MALDI MS and quantitatively compared on the Expressionist Refiner MS module. As a result, 345 out of 2,984 peaks (11.6%) showed the specific detection or the significantly improved intensities in deglycosylated serum samples (P < 0.01). We then applied this deglycosylation-based sample preparation to the identification of lung cancer biomarkers. In comparison between 10 healthy controls and 20 lung cancer patients, 40 peptides were identified to be differentially presented (P < 0.01). Their quantitative accuracies were further verified by multiple reaction monitoring. The result showed that deglycosylation was needed for the identification of some unique candidates, including previously unreported O-linked glycopeptide of complement component C9.
Conclusions
We demonstrated here that sample deglycosylation improves the quantitative performance of shotgun proteomics, which can be effectively applied to any samples with high glycoprotein contents.
Background
Since analyses of the serum proteome hold great promise for non-invasive detection of cancers and other diseases, various techniques for quantitative proteomic profiling have been developed to identify novel protein biomarkers[1,2]. These include labeling methods using stable isotopes such as ICAT (Isotope-coded affinity tags)[3], 13CNBS (2-nitrobenzenesulfenyl)[4], SILAC (Stable isotope labeling with amino acids in cell culture)[5] and iTRAQ (Isobaric tags for relative and absolute quantification)[6]. Control and test samples are labeled with reagents with different isotopic composition of 12/13C, 14/15N and/or 16/18O, and detected simultaneously by mass spectrometry so that the intensities of isotopically resolved peak-pairs (or peak groups) represent the quantitative ratio of control and test samples. Although the precision of quantification is very high (typically 10% relative standard deviation)[7] because of the identical separation and detection, isotopic labeling limits the number of samples to be directly compared, which makes it unsuitable for analysis of a large number of clinical samples needed for biomarker discoveries. In contrast, label-free quantification methods deal with independently-acquired mass spectrometry data from essentially unlimited number of samples. Quantification based on ion intensities (extracted ion chromatograms) is known to have at least three orders of linear dynamic range[8,9], and can potentially cover wide proteome in complex samples such as serum. It is advantageous that label-free systems do not involve sample mixing prior to detection because target proteins that are only presented in test samples are effectively diluted by mixing with control samples, rendering them more difficult to detect. Therefore, label-free quantification has emerged as an alternative approach for biomarker discovery, which requires sufficient sample sizes to overcome individual variability in clinical samples and technical bias in sample preparation and analysis batch[10].
High content of glycoproteins is another feature of serum that should be considered when performing quantitative proteomic analysis. Recent advances in glycoproteomic analysis using mass spectrometry have made it possible to exhaustively identify N-linked glycopeptides and their glycosylation sites[11,12]. These techniques involve enrichment of glycopeptides followed by enzymatic cleavage of N-glycans in order for efficient mass spectrometric analysis. Deglycosylation can be coupled with the incorporation of 18O stable isotope resulting in +3 Da mass shift of asparagine residues, which allows deterministic identification of glycosylation sites[13]. As these studies indicated, most of serum proteins are heavily glycosylated, however, potential effect of glycopeptides on ionization suppression of co-existing peptides had been overlooked. Glycopeptides carry large, hydrophilic carbohydrate moieties, which can cause substantial ionization suppression[14], hampering precise quantification particularly at low-concentration range.
To elucidate the extent to which the ionization of peptides is interfered by glycopeptides, the first part of this study describes the changes caused by serum deglycosylation in the MS peak profiles obtained by label-free shotgun proteomic analysis. Having shown the utility of deglycosylation, we next applied this principle to the biomarker screening of lung cancer. Because of the vast number of incidence and high mortality rate, lung cancer is considered to be one of the highest priorities for biomarker development. Using the serum samples of 10 healthy control, 10 early-stage (Stage I-II) cases and 10 advanced stage (Stages IIIb-IV) cases, we conducted a study that uniquely combined sample deglycosylation, label-free MALDI and multiple reaction monitoring (MRM) mass spectrometry[15] and verified the result by western blotting. Taken together, we show herein that enzymatic removal of carbohydrate moieties results in recognizable improvement in the data quality of shotgun proteomics in terms of sensitivity and reproducibility, which should facilitate quantitative analysis of glycoprotein-rich samples.
Results
Quantitative MS analysis of deglycosylated serum
In order to examine the effect of deglycosylation on data content and quality, tryptic digest of serum proteins was prepared with or without the removal of N-glycans and sialic acids (n = 6), and analyzed on the LC-MALDI label-free quantification platform as summarized in Figure 1. Figure 2 shows the 2-dimensional MS signal intensity maps after data processing by Expressionist Refiner MS (Genedata). In total, 27,357 single peaks were detected, comprising 4,444 groups of peaks each representing unique peptide species (termed "peak clusters"). Examples of the differences in the peak profile between deglycosylated and untreated samples are illustrated in the 2D map. The broken box in Figure 2a shows emergence of prominent peaks, and the expanded views in Figure 2c and 2d (arrows) illustrate the loss of intact glycopeptide peaks. The peak clusters subjected to comparative analysis were selected by eliminating peaks that were not presented in all of the 6 replicate runs. This filtering was performed separately for deglycosylated and untreated samples, yielding 2,984 and 2,610 peak clusters, respectively. Deglycosylation thus resulted in 14.3% increase in the number of reproducibly detectable peaks. The signal intensities of these peak profiles were then directly compared by t-test as summarized in the volcano plot (Figure 3). 221 peak clusters displayed altered intensities, of which 188 were higher in deglycosylated samples and 33 peak clusters vice versa (P < 0.01). Present/absent search revealed that 157 peak clusters were found specifically in deglycosylated samples (Figure S-1, Additional File 1). Combined, 345 of 2,984 peak clusters (11.6%) detected in deglycosylated samples were enhanced by deglycosylation, as opposed to 33 of 2,610 peak clusters (1.3%) in untreated serum.
The composition of the peak profiles was analyzed by exhaustive MS/MS analysis, resulting in 1,735 peptide identifications, including 153 originally-glycosylated peptides that were identified with 18O-incorporated N-glycosylation sites (Table S-2, Additional File 1). By matching the peptide IDs to the statistical analysis, we found that 97 of 345 peak clusters overrepresented in deglycosylated serum were originally-glycosylated peptides. These peak clusters emerged as the product of deglycosylation and accounted for most of the major fold-changes in the volcano plot as indicated with squares in Figure 3. The remaining 248 peak clusters, as well as the 33 peak clusters that diminished by deglycosylation, were non-glycopeptides. There were no apparent features common to these peptides. Rather, signal intensities were affected by the local peptide composition, such that alleviation of suppressive analytes led to signal enhancement and emergence of competing analytes led to diminished signal. The result shown here, that the number of enhanced peaks was by far greater than those that diminished, suggest that the ionization suppression effect exerted by intact glycopeptides was more extensive than the deglycosylated counterpart.
To investigate whether deglycosylation had any effect on the quality of quantitative data, reproducibility of six replicating runs was evaluated by calculating the correlation coefficients of the intensities of 2,356 clusters that were detected in all 12 runs. The correlation coefficients were calculated for all 15 possible combinations of 6 individual replicates within the experimental group. They ranged from 0.895 to 0.916 with mean value 0.899 (n = 15) in the untreated group and from 0.898 to 0.944 with mean value 0.914 (n = 15) in the deglycosylated group, suggesting that deglycosylation generally results in more reproducible data than the untreated (P < 0.002, t-test). Furthermore, coefficients of variation (CV) of the signal intensities for the same 2,356 peak clusters were calculated and compared between the two experimental groups (Figure 4). The frequency distribution of CV showed that deglycosylationtreatement resulted in slightly lowering the median CV from 34% to 31%. It is clear from these data that the effect of deglycosylation well extends to non-glycosylated peptides and enhances sensitivity and reproducibility.
Lung cancer biomarker screening
Deglycosylation-LC-MALDI platform was applied to the profiling of serum proteins for lung cancer biomarker screening. Control and lung cancer sera were immunodepleted, deglycosylated, purified on SDS-PAGE, in-gel digested and analyzed by LC-MALDI in the same way as described above. 30 mass chromatograms were processed simultaneously on Expressionist Refiner MS, and 23,453 peaks were detected, which were grouped into 6,186 peak clusters. Then we compared the two experimental groups, control (n = 10) and lung cancer (n = 20) by t-test and identified 63 peak clusters showing P < 0.01. In addition, 13 peak clusters were selected that have valid value of less than or equal to 2 in one experimental group and greater than 50% valid value proportion in the other. The total of 76 clusters was manually inspected and retrospective MS/MS was acquired by selecting the highest-expressing sample and the fraction spot of maximum elution for optimum MS/MS acquisition efficiency. As a result, 25 candidate proteins, comprising 40 candidate peptides, were identified (Table 1).
Table 1.
MALDI MS | MRM | ||||||
---|---|---|---|---|---|---|---|
Uniprot ID | Protein Name | Peptide Sequence | t-test † | Log2(LC/Control) | t-test ‡ | Log2(LC/Control) | Correlation Coefficient |
P04217 | Alpha-1B-glycoprotein | CEGPIPDVTFELLREGETKAVK | - | 0.67 | - | - | - |
FALVREDR | 3.8E-03 | -0.38 | 0.13 | 0.24 | 0.315 | ||
P01011 | Alpha-1-antichymotrypsin | EQLSLLDRFTEDAK | 1.4E-03 | 0.80 | 0.077 | 0.33 | 0.106 |
FTEDAKRLYGSEAFATDFQDSAAAK | 4.6E-03 | 0.58 | - | - | - | ||
PQDTHQSR | 5.6E-03 | 0.84 | - | - | - | ||
P43652 | Afamin | DGLKYHYLIR | 1.1E-03 | -0.93 | - | - | - |
P02746 | Complement C1q subcomponent subunit B | GNLCVNLMR | 6.5E-03 | 0.87 | - | - | - |
P00736 | Complement C1r subcomponent | CLPVCGKPVNPVEQR | - | 0.42 | - | - | - |
DYFIATCK | 6.9E-03 | 0.49 | 0.15 | 0.14 | -0.238 | ||
P00450 | Ceruloplasmin | YTVNQCR | 0.017 | 1.1 | 3.1E-04 | 0.29 | 0.411* |
P10909 | Clusterin | YVNKEIQNAVNGVK | 0.01 | 0.33 | 0.19 | -0.87 | -0.015 |
P06681 | Complement C2 | TAVDHIREILNINQK | 2.7E-03 | 1.4 | 0.051 | 0.23 | N/A |
P01024 | Complement C3 | AGDFLEANYMNLQR | 5.9E-05 | -1.4 | 3.8E-04 | -1.3 | 0.690** |
ILLQGTPVAQMTEDAVDAER | 2.1E-04 | -1.3 | 0.019 | -0.87 | 0.448* | ||
KGYTQQLAFR | 2.8E-03 | -1.1 | 3.9E-05 | -1.3 | 0.800** | ||
QPSSAFAAFVKR | 6.7E-03 | -1.3 | 2.0E-03 | 0.24 | -0.455 | ||
WLNEQR | 2.5E-03 | -1.0 | 7.8E-06 | -1.5 | 0.521** | ||
P01031 | Complement C5 | FWKDNLQHKDSSVPNTGTAR | 0.012 | 0.67 | - | - | - |
TLRVVPEGVKR | 0.066 | 0.80 | - | - | - | ||
P13671 | Complement component C6 | IEEADCKNKFR | 0.011 | 1.2 | - | - | - |
P10643 | Complement component C7 | VFSGDGKDFYR | 9.5E-03 | 0.81 | - | - | - |
P02748 | Complement Component C9 | FTPTETNKAEQCCEETASSISLHGK | 2.4E-04 | 1.4 | 6.1E-03 | 0.49 | 0.472* |
QYTgTSYDPELTESSGSASHIDCR | 1.9E-03 | 1.1 | 3.8E-03 | 0.57 | 0.769** | ||
P22792 | Carboxypeptidase N subunit 2 | SQCTYSNPEGTVVLACDQAQCR | 1.4E-03 | 0.56 | 0.062 | 0.16 | 0.372 |
P00748 | Coagulation factor XII | CTHKGRPGPQPWCATTPNFDQDQR | 4.3E-03 | 1.2 | - | - | - |
Q9UGM5 | Fetuin-B | MSPPQLALNPSALLSR | 3.0E-03 | 0.62 | 0.03 | 0.58 | 0.189 |
P02751 | Fibronectin | AQITGYR | 1.1E-03 | -0.47 | 0.077 | -0.18 | 0.774** |
GFNCESKPEAEETCFDKYTGNTYR | 1.9E-03 | -0.69 | 0.42 | -0.11 | 0.146 | ||
IGFKLGVRPSQGGEAPR | 5.7E-03 | -0.90 | - | - | - | ||
P26927 | Hepatocyte growth factor-like protein | RVDRLDQR | 6.1E-03 | -0.57 | 0.013 | 0.38 | -0.128 |
P18065 | Insulin-like growth factor-binding protein 2 | LAACGPPPVAPPAAVAAVAGGAR | 2.5E-03 | 0.67 | - | - | - |
Q06033 | Inter-alpha-trypsin inhibitor heavy chain H3 | EHLVQATPENLQEAR | 4.6E-03 | 0.97 | 3.6E-03 | 0.65 | 0.578** |
Q14624 | Inter-alpha-trypsin inhibitor heavy chain H4 | EKNGIDIYSLTVDSR | 4.7E-04 | 0.65 | 0.062 | 0.40 | 0.368 |
ETLFSVMPGLK | - | 0.09 | 0.01 | 0.42 | 0.331 | ||
MNFRPGVLSSR | 9.8E-03 | 0.40 | 1.0E-03 | 0.63 | 0.413* | ||
SPEQQETVLDGNLIIRYDVDR | 0.013 | 1.2 | - | - | - | ||
P03952 | Plasma kallikrein | CQFFTYSLLPEDCKEEKCK | - | -0.32 | - | - | - |
P01042 | Kininogen-1 | RPPGFSPF | 2.0E-04 | -2.0 | 5.1E-04 | -1.74 | 0.876** |
P27918 | Properdin | TCNHPVPQHGGPFCAGDATR | 7.2E-04 | -0.52 | - | - | - |
Q13103 | Secreted phosphoprotein 24 | DSGEDPATCAFQR | 3.7E-03 | -0.53 | - | - | - |
†: "-" indicates candidate screened by present/absent search,
‡: "-" indicates no MRM data obtained, *: P < 0.05, **: P < 0.01,
g: indicates site of O-linked glycosylation
N/A: valid value too small for calculation of correlation threshold.
Next, these candidates were verified at peptide level by the MRM-based relative quantification analysis using the same preparation batch of serum tryptic digest as used for MALDI MS analysis as it is previously reported that LC-MALDI measurement is the most significant source of technical variability above sample preparation[16] (see Table S-3, Additional File 1 for the list of MRM transitions). This strategy was aimed at eliminating false-positive results from the long list of candidates and facilitating the selection of appropriate target for validation study. Of the 23 peptides that we found working MRM transitions, 11 peptides showed significant correlation (P < 0.05 by Pearson's correlation coefficient) in results obtained by MRM and MALDI MS, and 10 peptides (6 proteins) fulfilled P < 0.05 in both analyses. These peptide candidates were derived from ceruloplasmin, complement C3, complement component C9, inter-alpha-trypsin inhibitor heavy chain H3, inter-alpha-trypsin inhibitor heavy chain H4 and kininogen-1. The quantification results were summarized as dot-plots in Figure 5 to illustrate the potential performance of the 10 peptides as biomarker candidates. Raw data was normalized to the total detection and the samples were grouped as normal control, early stage (Stage I/II) and advanced stage (stage IIIb/IV) lung cancer cases. As the P-values indicate, most of the candidates showed significant response to cancer state even at early stages.
Further verification was performed by western blotting of complement C3 protein. Interestingly, expression of 39 kDa subunit of C3 protein was strongly suppressed in early-stage patients (Figure 6A). Since this subunit was also detected by the monoclonal antibody raised against C3d fragment (Figure S-2 Additional File 1), the 39 kDa subunit was assigned to be C3dg fragment[17]. This fragment encompasses all of the four C3 peptide candidates identified by LC-MALDI screening, and semi-quantitative analysis of the immunoblot (Figure 6B) almost exactly reproduced the screening result. Moreover, C3dg fragment was shown to escape immunodepletion by MARS-Hu14 column (Figure S-2). Therefore, the apparent difference in complement C3 abundance observed in the screening was reflecting the degree of proteolytic degradation associated with lung cancer.
Finally, the benefit of deglycosylation in this biomarker screening was assessed by mining the candidate peptides from the control experiment (comparing deglycosylated and untreated serum) and verifying whether or not deglycosylation facilitated biomarker identification. Figure 7 shows the levels of complement component C9 peptides in the control experiment, which were clearly overrepresented by deglycosylation. Notably, the signal intensity of non-glycopeptide (243-267) was doubled, reiterating the observation that non-glycopeptide was also subject of signal enhancement by deglycosylation. Moreover, the signal intensity of peptide (22-44) was increased by 10-fold. Since this peptide was identified as O-linked glycopeptide (attachment of N-acetylgalactosamine and galactose as predicted from the m/z shift), the addition of sialidase probably contributed to reduction of glycan complexity and increased ionization efficiency. The sialylated counterpart was not detected in the untreated control.
Discussion
The aim of this study was to introduce deglycosylation as a facile and universal sample preparation step in shotgun proteomic analysis because we expected that the undermining effect exerted by the large proportion of glycopeptides was more extensive than previously considered. Therefore, for the first time, we have performed a direct comparison between deglycosylated and untreated serum samples, and showed that deglycosylation actually results in improvement of the shotgun peak profile. This was observed in terms of both acquisition of unique peaks and enhancement of existing peaks.
The acquisition of unique peaks by deglycosylation was expected, as it is widely recognized that deglycosylated peptides have much higher ionization efficiency than the corresponding glycopeptides[18,19]. It is well established that deglycosylation results in the detection of "new" peaks and increases the depth of information acquired by shotgun analysis[20,21]. However, this study revisited the same phenomenon from different perspective. Our novel finding was that signal enhancement by deglycosylation extended up to 8% of existing non-glycopeptide peaks (Figure 3). This result strongly suggested that there was notable ionization suppression effect exerted by glycopeptides on co-existing analytes, and that signal intensities were enhanced through alleviation of suppression in deglycosylated sample. Incorporation of 18O into the site of deglycosylation by H218O was utilized to facilitate the identification of glycopeptides. The potential pitfalls of this approach as pointed out by Angel et al.[22] was circumvented by performing deglycosylation before tryptic digestion, and our data showed that 73% of identified glycopeptides fulfilled the biological consensus NxT/S. This strategy helped to confirm that only a small proportion of peaks that were enhanced by deglycosylation were actually glycosylated. We further demonstrated the evidence that deglycosylation improves the reproducibility of replicate measurements to some extent (Figure 4). The level of technical variability, median CV of 31%, was comparable to previously reported label-free quantification methods based on LC-ESI-MS[8] or LC-MALDI MS[16].
Unfortunately, previous studies on ionization suppression effects had mainly focused on selective detection of glycopeptides in mixtures of peptides[23], and cannot explain the phenomenon addressed here. Separate investigation needs to be conducted in order to elucidate the mechanism and the extent to which glycopeptides interfere with the ionization of co-existing peptides.
Serum deglycosylation coupled with label-free quantification was applied to biomarker screening for lung cancer and led to the identification of unique biomarker candidates including the fragmentation state of complement C3, complement component C9 peptide with novel O-linked carbohydrate and Kininogen-1 peptide with C-terminal Phe[24]. The benefit of deglycosylation in the biomarker screening was demonstrated by enhanced detectability of the complement component C9 peptides, particularly for O-linked glycopeptide whose intact form with sialic acid was hardly detected. Since many O-linked glycans contain sialic acid, the data presented here demonstrates a high potential of sialidase usage for comprehensive analysis of O-linked glycans.
As with other label-free quantitative proteomics, more proteins were quantified by single peptide than those quantified by multiple peptides[25] due to the high technical variability associated with label-free shotgun analysis. Therefore, we employed MRM to complement the screening by MALDI MS with the aim of eliminating false-positive results. This approach successfully ruled out many candidates while retaining confident candidates, as verified by western blotting experiment of complement C3.
Complement C3 is the major component of the classical complement pathway. Upon antigenic stimulation, C3 convertase cleaves C3 into C3a and C3b, which subsequently triggers reaction cascade leading to the formation of membrane attack complex, by either the classical or alternative pathway[17]. C3a contains a multiply interacting motif known as anaphylatoxin[26]. Recently, a number of proteomic studies have identified C3a as biomarker candidates for colon cancer[27], chronic hepatitis C and related hepatocellular carcinoma[28], insulin resistance/type-2 diabetes[29] and chronic lymphoid malignancies[30]. While upregulation of C3a is widely reported and interpreted as an indicator of primary inflammatory response, there is limited association reported between C3dg and cancer. C3dg is known as the ligand of complement receptor 2[31] and may be critically involved in cancer recognition. The mechanism by which the production of C3dg is suppressed in response to the onset of lung cancer requires further investigation.
In the Expressionist label-free quantification platform employed here, peptide peak clusters are defined by retention time-m/z coordinate on the 2D-map, enabling quantitative analysis without MS/MS information that were essential in other platforms[32-35]. The feature that provides the ground for this concept is perfect alignment of mass chromatograms in the retention time dimension because slight drift is unavoidable even in well-optimized separation system. In this respect, Expressionist demonstrated spectacular computational strength. The range of retention time drift in the 30 LC-MALDI analyses performed in this study was from -5 minutes to +5 minutes, a maximum of 10 minutes deviation, but the software was still capable of good alignment without any obvious retention time mismatch (data not shown). Therefore, variation in experimental conditions, such as changing the analytical column lot, should easily be tolerated. This feature enables integration of several, even retrospective, analyses, which is needed for the continuous pursuit for biomarker identification and validation.
Moreover, being a server-based module, Expressionist has greater data processing capability than other stand-alone software. This is another advantageous feature because, in general, attempts to increase proteome coverage involve vast increase in data amount, whether it be a multi-dimensional fractionation strategy[36,37] or an extremely long gradient separation[38]. Importantly, considering the fact that low-abundance analytes are more prone to ionization suppression[39], we speculate that the benefits of sample deglycosylation we addressed here would take greater effect with increasing dynamic range of detection. Such in-depth label-free analysis is currently not available, however, we demonstrated herein that current technology is already capable of large-scale label-free analysis, and we addressed its potentiality as a biomarker discovery platform. Taken together, we believe that sample deglycosylation will prove to be a valuable sample preparation protocol in shotgun proteomic analysis in near future for analyzing glycoprotein-rich samples.
Conclusions
The studies described herein demonstrated that serum deglycosylation has positive effect on both data content and reproducibility through production of deglycosylated peptides and possibly through alleviation of ionization suppression by intact glycopeptides. The results therefore suggested the role of deglycosylation as a simple, indispensible method to improve the general performance of label-free quantification. Its first application to serum proteomic profiling by label-free LC-MALDI MS demonstrated that this strategy could lead to the identification of unique candidates, which could be effectively applied to any samples with high glycoprotein contents, such as other clinical body fluids, membrane proteomics or secretome analysis.
Methods
Reagents
Trizma base pH 8.3, iodoacetamide, ammonium bicarbonate, ammonium citrate, formic acid were purchased from Sigma (Saint Louis, MO). PlusOne grade SDS and dithiothreitol (DTT) were purchased from GE Healthcare (Uppsala, Sweden). CHAPS was purchased from Chemical Dojin (Kumamoto, Japan). N-glycosidase F was purchased from Roche (Basel, Switzerland). α2-3,6,8,9-neuraminidase was purchased from Merck (Darmstadt, Germany). Trypsin Gold was purchased from Promega (Madison, WI). H218O was supplied from Cambridge Isotope Laboratories Inc. (Andover, MA). Alpha-cyano-4-hydroxycinnamic acid (CHCA) was purchased from Shimadzu-GLC (Kyoto, Japan). LC/MS grade acetonitrile and 25% trifluoroacetic acid (TFA) were purchased from Wako Pure Chemicals (Osaka, Japan).
Serum Samples
Archived human serum samples were obtained with informed consent from 20 patients with lung adenocarcinoma and at Hiroshima University Hospital. Serum samples as normal controls were also obtained with informed consent from 13 healthy volunteers who received medical checkup at Hiroshima University Hospital (Table S-1, Additional File 1). Serum was collected using standard protocol from whole blood by centrifugation at 1500 × g for 10 min and stored at -150°C. This study was approved by individual institutional ethical committees.
Immunodepletion
20 μL serum aliquots obtained from healthy volunteer were subjected to Multiple Affinity Removal System (Hu-14, 4.6 mm × 100 mm, Agilent Technologies, Santa Clara, CA) according to the manufacturer's protocol using a conventional HPLC system (Shimadzu Corp., Kyoto, Japan). The flow-through fraction was desalted with a protein separation column (mRP-C18, 4.6 mm × 50 mm, Agilent Technologies). Desalted serum proteins were dried with a SpeedVac evaporator.
Deglycosylation
All solutions in the following deglycosylation step were freshly prepared with H218O. Protein aliquots were dissolved in 12.5 μL of 2% SDS, 20 mM DTT, 20 mM Trizma-base pH 8.3 and heated to 100°C for 5 minutes. After cooling, 25 μL of 10% CHAPS, 83.4 μL 20 mM Trizma-base pH 8.3, 1 μL N-glycosidase F and 0.6 μL α2-3,6,8,9-neuraminidase were added in the written order with thorough mixing. H218O was added in place of the enzymes for "untreated" samples. The reaction mixture was incubated at 37°C overnight.
Tryptic digestion
Deglycosylated proteins were reduced by 10 mM DTT and incubated at 56°C for 15 minutes, followed by alkylation by 50 mM iodoacetamide at ambient temperature for 45 minutes in dark. 20% of the total reaction mixture was purified by SDS-PAGE, applying voltage until all of the proteins had entered the separating gel. Whole lanes were cut out and subjected to in-gel tryptic digestion. Briefly, gel slices were cut into small pieces and were washed 3 times in 30% acetonitrile 50 mM ammonium bicarbonate before digesting with 200 ng of trypsin in 100 μL 50 mM ammonium bicarbonate at 37°C overnight. Peptides were extracted by 2 rounds of 50% acetonitrile and 100% acetonitrile washes. Recovered peptides were dried in SpeedVac and reconstituted in 10 μL of 2% acetonitrile 0.1% TFA for LC-MALDI analysis.
LC-MALDI Analysis
Serum tryptic digest with or without deglycosylation was separated using DiNa nano-HPLC system (KYA Technologies, Tokyo, Japan). Solvent A was 2% acetonitrile and 0.1% TFA in water and solvent B was 70% acetonitrile and 0.1% TFA in water. 2 μL sample, a final amount equivalent to 0.4 μL serum, was injected onto a trap column (L-column ODS, 5 μm, 0.3 × 5 mm, CERI, Saitama, Japan) and loaded by 8 μL/min flow of solvent A. At 5 min, valve was switched and the peptides were separated by an in-house packed analytical column (L-column ODS, 3 μm, in 0.1 mm × 200 mm capillary) at 200 nL/min flow rate using the following gradient: 5 min, 2% solvent B; 6 min, 10% solvent B; 90 min, 55% solvent B; 95 min, 100% solvent B; and 110 min, 100% solvent B. The column end was connected directly to the spotting tip of DiNA MAP target plate spotting device (KYA Technologies). CHCA matrix solution was prepared at 1.5 mg/mL concentration in 70% acetonitrile, 0.1% TFA and 0.03 mg/mL ammonium citrate, which was pumped to the spotting tip at 2.2 μL/min flow rate and therein mixed with column elution. The mixture was deposited onto a 1536-well μFocusing plate (Hudson Surface Technologies Inc., Newark, NJ) every 15 seconds between 20.0 to 109.75 minutes for a total of 360 spot fractions. Mass spectrometric analysis was performed using 4800 Plus MALDI TOF/TOF Analyzer (AB Sciex, Foster City, CA) operated on 4000 Series Explorer software version 3.5. For each fraction spot, data was accumulated from 1000 laser shots in a randomized raster of 400 μm diameter over mass range m/z 800-4000. The laser repeat rate was 200 Hz and the laser power was fixed at 3500 units throughout the experiment. 5 calibration spots comprising 6 standard peptides were used for external calibration.
Data analysis
Individual MALDI MS raw data was exported as t2d file, ordered in chromatographic order and imported into Expressionist Refiner MS system (Genedata AG, Basel, Switzerland), where they were combined and displayed as mass chromatograms. Default processing parameters were applied unless otherwise specified. The chromatogram data was first simplified by subtracting the background noise by using the following criteria: 0.3 min RT window, 40% quantile subtraction, 0.15 point RT smoothing. After subtraction, all data points below threshold intensity of "100" were clipped to zero. A set of chromatograms were then aligned in the RT direction by nonlinear transformation, mapping the original time onto a common universal retention time, to ensure that equal RT values correspond to the elution of the same compounds. The following parameters were applied: RT transformation window, 5 min; RT search interval, 30 min; m/z window, 0.2 Da; gap penalty, 1. Peak signals were detected by summed peak detection algorithm, which computes a temporary averaged chromatogram over all input chromatograms, thereby allowing them to share the matching set of peaks with identical boundaries. Here, the summation windows of 0.2 Da in the m/z direction and 1 minute in the RT direction were selected. The detected peaks were grouped into isotopic clusters of individual compounds by summed isotope clustering activity, using the following parameters: minimum charge, 1; maximum charge, 2; maximum missing peaks, 1; first allowed gap position, 3; RT window, 1 min; peptide isotope shaping tolerance, 0.8.
Statistical analysis
The cluster information generated by Refiner MS was imported into Genedata Expressionist Analyst software for statistical analysis. The clusters were first filtered by a valid value proportion of 100% (i.e. signal was detected in all of the experimental replicates). All of these clusters were subjected to t-test for extracting differentially expressed clusters between the experimental groups, where P < 0.01 was considered to be significant. Present/absent search was performed to select for clusters with 0 or 1 counterpart detection, which were omitted by t-test.
Protein identification
As an exhaustive study, full MS/MS analysis was performed on three of the replicate runs. Precursor peaks were selected according to the software interpretation algorithm, while limiting the maximum number of acquisition to 10 per spot. Precursor peaks were measured in descending order of intensity. Precursor ions were isolated at 150 FWHM resolution, fragmentation was induced without the use of collision gas at 6 kV and fragment ions were further accelerated at 15 kV. Laser power of 4200 units was used, and the acquisition was summed over 2000 laser shots or until 4 fragment peaks exceeded S/N 100. Protein Pilot software version 2.0 was used to generate MS/MS peak lists for searching by MASCOT[32] version 2.2.03 (Matrix Science, London, U.K.) against 20345 human sequences of SwissProt version 57.14. Prior to search, a custom +3 Da modification on asparagine residue resulting from deglycosylation in H218O was defined. The search parameters were as follows: enzyme, trypsin (allow up to 2 missed cleavages); fixed modification, carbamidomethyl; variable modifications, 18O-deglycosylation (Asn); peptide tolerance, 300 ppm; MSMS tolerance, 0.5 Da. Ion expectation score of 0.05 was used for the cut-off line for identification. For candidate biomarker peptides that were not identified by this method, searching was iteratively repeated in different search parameters, such as "semitrypsin" enzyme restriction, "N-terminal pyroglutamic acid" and "+365 Da modification on Thr" (corresponding to O-linked N-acetylhexosamine and hexose attached to a threonine residue) as variable modifications.
Multiple reaction monitoring
2 μL of the serum tryptic digest analyzed by LC-MALDI was diluted by adding 6 μL of solvent A and 4 μL of tBSA proteomic standard (KYA Technologies) dissolved at 50 fmol/μL. 1 μL of this mixture was injected for a single analysis. Paradigm nano-HPLC system with PAL autoinjector was used for separation. Solvent A was 2% ACN in 0.1% formic acid, solvent B was 90% ACN in 0.1% formic acid, and sample was loaded with 2% ACN in 0.1% TFA. The trap column was L-column ODS, 5 μm, 0.3 × 5 mm, and the analytical column was L-column ODS loaded in-house directly into a sprayer tip (GL Science, Tokyo, Japan). MRM was performed using 4000QTRAP mass spectrometer (AB Sciex) during a 13 minutes gradient (2-55% solvent B) at 200 nL/min flow rate. 70 ions were monitored simultaneously for 30 minutes, each transition with 20 ms dwell time with 5 ms interval, taking a total of 1.75 s per scan. Transitions were selected from series of pilot experiment in which in-silico developed transitions for each peptide were tested for signal intensity and specificity. Transitions were considered as the derivative of target peptide only when all of them responded simultaneously and the retention time of detection matched that of LC-MALDI data. Instrument settings were as follows: declustering potential, 70; entrance potential, 10; curtain gas, 10; collision gas, 4; ion spray voltage, 2100; ion source gas, 10; interphase heater temperature, 150°C. Peak areas were integrated using MultiQuant software version 1.1.0.26. Raw data was normalized to the total signal acquired, which includes two spiked-in BSA fragments detected at highest intensity.
Immunoblot analysis
For the verification study, crude serum samples from fresh aliquots for all screening sample set (except for 3 normal controls N-3, 4, and 10, which were substituted by N-11, 12, and 13, respectively) were analyzed. 0.5 μL of crude serum was diluted 100-fold with SDS-PAGE sample buffer, boiled and 20 μL was used for immunoblot analysis. SDS-PAGE was performed using NuPAGE Bis-Tris 4-12% acrylamide gel with 2-morpholinoethanesulfonic acid buffer system, and electroblotted onto a PVDF membrane. The blots were probed with anti-C3 polyclonal antibody (Sigma, product code GW20073F) diluted 5000-fold in 5% skim milk, followed by incubation with horseradish peroxidise-conjugated secondary antibody (Sigma, product code A9046) diluted 10000-fold in 2% BSA. The reactivity was visualized on X-ray films using ECL detection kit (GE Healthcare). Immunoblot was also performed with anti-C3d monoclonal antibody (Abbiotec, San Diego, CA) and horseradish peroxidise-conjugated secondary antibody (GE Healthcare) to confirm specificity of the polyclonal antibody (Figure S-2).
Competing interests
This study is supported in part by the grants from Toppan Printing Co., Ltd., Tokyo, Japan, and Shimadzu Corporation, Kyoto, Japan.
Authors' contributions
AT performed all experiments and drafted the manuscript. HN and KM added statistical interpretation. NI and NK provided the serum samples and revised the manuscript. YD and TAS contributed to mass spectrometry analysis. YN critically revised the manuscript. KU conceived the study, helped in experimental design and critically revised the manuscript. All authors read and approved the final manuscript.
Supplementary Material
Contributor Information
Atsuhiko Toyama, Email: toyama@shimadzu.co.jp.
Hidewaki Nakagawa, Email: hidewaki@ims.u-tokyo.ac.jp.
Koichi Matsuda, Email: koichima@ims.u-tokyo.ac.jp.
Nobuhisa Ishikawa, Email: nobuhi@hiroshima-u.ac.jp.
Nobuoki Kohno, Email: nokohno@hiroshima-u.ac.jp.
Yataro Daigo, Email: ydaigo@ims.u-tokyo.ac.jp.
Taka-Aki Sato, Email: takaaki@shimadzu.co.jp.
Yusuke Nakamura, Email: yusuke@ims.u-tokyo.ac.jp.
Koji Ueda, Email: k-ueda@riken.jp.
References
- Anderson NL, Anderson NG. The human plasma proteome: history, character, and diagnostic prospects. Mol Cell Proteomics. 2002;1:845–867. doi: 10.1074/mcp.R200007-MCP200. [DOI] [PubMed] [Google Scholar]
- Ong SE, Mann M. Mass spectrometry-based proteomics turns quantitative. Nat Chem Biol. 2005;1:252–262. doi: 10.1038/nchembio736. [DOI] [PubMed] [Google Scholar]
- Gygi SP, Corthals GL, Zhang Y, Rochon Y, Aebersold R. Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology. Proc Natl Acad Sci USA. 2000;97:9390–9395. doi: 10.1073/pnas.160270797. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kuyama H, Watanabe M, Toda C, Ando E, Tanaka K, Nishimura O. An approach to quantitative proteome analysis by labeling tryptophan residues. Rapid Commun Mass Spectrom. 2003;17:1642–1650. doi: 10.1002/rcm.1100. [DOI] [PubMed] [Google Scholar]
- Ong SE, Blagoev B, Kratchmarova I, Kristensen DB, Steen H, Pandey A, Mann M. Stable isotope labeling by amino acids in cell culture, SILAC, as a simple and accurate approach to expression proteomics. Mol Cell Proteomics. 2002;1:376–386. doi: 10.1074/mcp.M200025-MCP200. [DOI] [PubMed] [Google Scholar]
- Ross PL, Huang YN, Marchese JN, Williamson B, Parker K, Hattan S, Khainovski N, Pillai S, Dey S, Daniels S. et al. Multiplexed protein quantitation in Saccharomyces cerevisiae using amine-reactive isobaric tagging reagents. Mol Cell Proteomics. 2004;3:1154–1169. doi: 10.1074/mcp.M400129-MCP200. [DOI] [PubMed] [Google Scholar]
- Schulze WX, Usadel B. Quantitation in Mass-Spectrometry-Based Proteomics. Annu Rev Plant Biol. 2010. [DOI] [PubMed]
- Wang W, Zhou H, Lin H, Roy S, Shaler TA, Hill LR, Norton S, Kumar P, Anderle M, Becker CH. Quantification of proteins and metabolites by mass spectrometry without isotopic labeling or spiked standards. Anal Chem. 2003;75:4818–4826. doi: 10.1021/ac026468x. [DOI] [PubMed] [Google Scholar]
- Bondarenko PV, Chelius D, Shaler TA. Identification and relative quantitation of protein mixtures by enzymatic digestion followed by capillary reversed-phase liquid chromatography-tandem mass spectrometry. Anal Chem. 2002;74:4741–4749. doi: 10.1021/ac0256991. [DOI] [PubMed] [Google Scholar]
- Omenn GS, States DJ, Adamski M, Blackwell TW, Menon R, Hermjakob H, Apweiler R, Haab BB, Simpson RJ, Eddes JS. et al. Overview of the HUPO Plasma Proteome Project: results from the pilot phase with 35 collaborating laboratories and multiple analytical groups, generating a core dataset of 3020 proteins and a publicly-available database. Proteomics. 2005;5:3226–3245. doi: 10.1002/pmic.200500358. [DOI] [PubMed] [Google Scholar]
- Zhang H, Li XJ, Martin DB, Aebersold R. Identification and quantification of N-linked glycoproteins using hydrazide chemistry, stable isotope labeling and mass spectrometry. Nat Biotechnol. 2003;21:660–666. doi: 10.1038/nbt827. [DOI] [PubMed] [Google Scholar]
- Liu T, Qian WJ, Gritsenko MA, Camp DG, Monroe ME, Moore RJ, Smith RD. Human plasma N-glycoproteome analysis by immunoaffinity subtraction, hydrazide chemistry, and mass spectrometry. J Proteome Res. 2005;4:2070–2080. doi: 10.1021/pr0502065. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kaji H, Saito H, Yamauchi Y, Shinkawa T, Taoka M, Hirabayashi J, Kasai K, Takahashi N, Isobe T. Lectin affinity capture, isotope-coded tagging and mass spectrometry to identify N-linked glycoproteins. Nat Biotechnol. 2003;21:667–672. doi: 10.1038/nbt829. [DOI] [PubMed] [Google Scholar]
- Constantopoulos TL, Jackson GS, Enke CG. Effects of salt concentration on analyte response using electrospray ionization mass spectrometry. J Am Soc Mass Spectrom. 1999;10:625–634. doi: 10.1016/S1044-0305(99)00031-8. [DOI] [PubMed] [Google Scholar]
- Makawita S, Diamandis EP. The bottleneck in the cancer biomarker pipeline and protein quantification through mass spectrometry-based approaches: current strategies for candidate verification. Clin Chem. 2010;56:212–222. doi: 10.1373/clinchem.2009.127019. [DOI] [PubMed] [Google Scholar]
- Hattan SJ, Parker KC. Methodology utilizing MS signal intensity and LC retention time for quantitative analysis and precursor ion selection in proteomic LC-MALDI analyses. Anal Chem. 2006;78:7986–7996. doi: 10.1021/ac0610513. [DOI] [PubMed] [Google Scholar]
- Sahu A, Lambris JD. Structure and biology of complement protein C3, a connecting link between innate and acquired immunity. Immunol Rev. 2001;180:35–48. doi: 10.1034/j.1600-065X.2001.1800103.x. [DOI] [PubMed] [Google Scholar]
- Lochnit G, Geyer R. An optimized protocol for nano-LC-MALDI-TOF-MS coupling for the analysis of proteolytic digests of glycoproteins. Biomed Chromatogr. 2004;18:841–848. doi: 10.1002/bmc.399. [DOI] [PubMed] [Google Scholar]
- Wuhrer M, Catalina MI, Deelder AM, Hokke CH. Glycoproteomics based on tandem mass spectrometry of glycopeptides. J Chromatogr B Analyt Technol Biomed Life Sci. 2007;849:115–128. doi: 10.1016/j.jchromb.2006.09.041. [DOI] [PubMed] [Google Scholar]
- Liu T, Qian WJ, Gritsenko MA, Xiao W, Moldawer LL, Kaushal A, Monroe ME, Varnum SM, Moore RJ, Purvine SO. et al. High dynamic range characterization of the trauma patient plasma proteome. Mol Cell Proteomics. 2006;5:1899–1913. doi: 10.1074/mcp.M600068-MCP200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang Y, Wu SL, Hancock WS. Approaches to the study of N-linked glycoproteins in human plasma using lectin affinity chromatography and nano-HPLC coupled to electrospray linear ion trap--Fourier transform mass spectrometry. Glycobiology. 2006;16:514–523. doi: 10.1093/glycob/cwj091. [DOI] [PubMed] [Google Scholar]
- Angel PM, Lim JM, Wells L, Bergmann C, Orlando R. A potential pitfall in 18O-based N-linked glycosylation site mapping. Rapid Commun Mass Spectrom. 2007;21:674–682. doi: 10.1002/rcm.2874. [DOI] [PubMed] [Google Scholar]
- Fukuyama Y, Nakaya S, Yamazaki Y, Tanaka K. Ionic liquid matrixes optimized for MALDI-MS of sulfated/sialylated/neutral oligosaccharides and glycopeptides. Anal Chem. 2008;80:2171–2179. doi: 10.1021/ac7021986. [DOI] [PubMed] [Google Scholar]
- Seraglia R, Molin L, Tonidandel L, Pucciarelli S, Agostini M, Urso ED, Bedin C, Quaia M, Nitti D, Traldi P. An investigation on the nature of the peptide at m/z 904, overexpressed in plasma of patients with colorectal cancer and familial adenomatous polyposis. J Mass Spectrom. 2007;42:1606–1612. doi: 10.1002/jms.1358. [DOI] [PubMed] [Google Scholar]
- Xue H, Lu B, Zhang J, Wu M, Huang Q, Wu Q, Sheng H, Wu D, Hu J, Lai M. Identification of serum biomarkers for colorectal cancer metastasis using a differential secretome approach. J Proteome Res. 2010;9:545–555. doi: 10.1021/pr9008817. [DOI] [PubMed] [Google Scholar]
- Huber R, Scholze H, Paques EP, Deisenhofer J. Crystal structure analysis and molecular model of human C3a anaphylatoxin. Hoppe Seylers Z Physiol Chem. 1980;361:1389–1399. doi: 10.1515/bchm2.1980.361.2.1389. [DOI] [PubMed] [Google Scholar]
- Ward DG, Suggett N, Cheng Y, Wei W, Johnson H, Billingham LJ, Ismail T, Wakelam MJ, Johnson PJ, Martin A. Identification of serum biomarkers for colon cancer by proteomic analysis. Br J Cancer. 2006;94:1898–1905. doi: 10.1038/sj.bjc.6603188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lee IN, Chen CH, Sheu JC, Lee HS, Huang GT, Chen DS, Yu CY, Wen CL, Lu FJ, Chow LP. Identification of complement C3a as a candidate biomarker in human chronic hepatitis C and HCV-related hepatocellular carcinoma using a proteomics approach. Proteomics. 2006;6:2865–2873. doi: 10.1002/pmic.200500488. [DOI] [PubMed] [Google Scholar]
- Zhang R, Barker L, Pinchev D, Marshall J, Rasamoelisolo M, Smith C, Kupchak P, Kireeva I, Ingratta L, Jackowski G. Mining biomarkers in human sera using proteomic tools. Proteomics. 2004;4:244–256. doi: 10.1002/pmic.200300495. [DOI] [PubMed] [Google Scholar]
- Miguet L, Bogumil R, Decloquement P, Herbrecht R, Potier N, Mauvieux L, Van Dorsselaer A. Discovery and identification of potential biomarkers in a prospective study of chronic lymphoid malignancies using SELDI-TOF-MS. J Proteome Res. 2006;5:2258–2269. doi: 10.1021/pr060058y. [DOI] [PubMed] [Google Scholar]
- Diefenbach RJ, Isenman DE. Mutation of residues in the C3dg region of human complement component C3 corresponding to a proposed binding site for complement receptor type 2 (CR2, CD21) does not abolish binding of iC3b or C3dg to CR2. J Immunol. 1995;154:2303–2320. [PubMed] [Google Scholar]
- Lu P, Vogel C, Wang R, Yao X, Marcotte EM. Absolute protein expression profiling estimates the relative contributions of transcriptional and translational regulation. Nat Biotechnol. 2007;25:117–124. doi: 10.1038/nbt1270. [DOI] [PubMed] [Google Scholar]
- Ishihama Y, Oda Y, Tabata T, Sato T, Nagasu T, Rappsilber J, Mann M. Exponentially modified protein abundance index (emPAI) for estimation of absolute protein amount in proteomics by the number of sequenced peptides per protein. Mol Cell Proteomics. 2005;4:1265–1272. doi: 10.1074/mcp.M500061-MCP200. [DOI] [PubMed] [Google Scholar]
- Rower C, Vissers JP, Koy C, Kipping M, Hecker M, Reimer T, Gerber B, Thiesen HJ, Glocker MO. Towards a proteome signature for invasive ductal breast carcinoma derived from label-free nanoscale LC-MS protein expression profiling of tumorous and glandular tissue. Anal Bioanal Chem. 2009;395:2443–2456. doi: 10.1007/s00216-009-3187-9. [DOI] [PubMed] [Google Scholar]
- Monroe ME, Tolic N, Jaitly N, Shaw JL, Adkins JN, Smith RD. VIPER: an advanced software package to support high-throughput LC-MS peptide identification. Bioinformatics. 2007;23:2021–2023. doi: 10.1093/bioinformatics/btm281. [DOI] [PubMed] [Google Scholar]
- Washburn MP, Wolters D, Yates JR. Large-scale analysis of the yeast proteome by multidimensional protein identification technology. Nat Biotechnol. 2001;19:242–247. doi: 10.1038/85686. [DOI] [PubMed] [Google Scholar]
- Wu CC, MacCoss MJ, Howell KE, Yates JR. A method for the comprehensive proteomic analysis of membrane proteins. Nat Biotechnol. 2003;21:532–538. doi: 10.1038/nbt819. [DOI] [PubMed] [Google Scholar]
- Iwasaki M, Miwa S, Ikegami T, Tomita M, Tanaka N, Ishihama Y. One-dimensional capillary liquid chromatographic separation coupled with tandem mass spectrometry unveils the Escherichia coli proteome on a microarray scale. Anal Chem. 2010;82:2616–2620. doi: 10.1021/ac100343q. [DOI] [PubMed] [Google Scholar]
- Knochenmuss R, Zenobi R. MALDI ionization: the role of in-plume processes. Chem Rev. 2003;103:441–452. doi: 10.1021/cr0103773. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.