Abstract
To evaluate and compare the dimensional stability, accuracy and surface hardness of three interocclusal recording materials at various time intervals. Polyvinylsiloxane, Zinc oxide eugenol, Aluwax were taken for this study. A stainless steel die of ADA specification no 19. was prepared. A total of ten samples were made with each group. The samples were measured using a travelling microscope of 10× magnification at 1, 24, 48 and 72 h time intervals. Five readings were taken for each sample, the mean was considered to measure the dimensional change, accuracy and surface hardness. The values obtained were statistically analysed by ANOVA and Tukey HSD-Honestly significant difference. Polyvinylsiloxane was the most dimensionally stable, accurate and had the highest surface hardness among the three inter-occlusal materials.
Keywords: Dimensional stability, Accuracy, Hardness
Introduction
The success of any prosthetic rehabilitating treatment depends on several aspects related to the precise mounting of casts in the articulator [1]. Interocclusal recording materials are basically similar to impression materials but are modified to give good handling characteristics [2] however these alterations in the parent impression material resulted in altered properties which is unknown.
According to Warren and Capp, the basic principal approach should be to make the interocclusal record at the correct occlusal vertical dimension, choosing an accurate, dimensionally stable recording material, and selecting an appropriate method of mandibular guidance [3].
Many materials have been used for maxilla-mandibular registration procedures including wax, acrylic resin, zinc oxide eugenol pastes, modelling compound and plaster. Currently, elastomeric materials such as polyether and polyvinylsiloxane have been widely used for the same purpose. When elastomeric inter-occlusal recording materials are clinically used, flow characteristics of the mixed materials are necessary to reproduce a surface detail. But over clinically reasonable time periods, they must have solid like hardness to retain the shape and strength when dental casts are articulated. The viscoelasticity of dental materials is important in the selection of suitable materials for clinical applications [4].
Direct interocclusal records are most commonly used to record maxilla-mandibular relationships because of their simplicity. The arches are brought into a relationship with or without tooth contact, and a space is created between the teeth. The recording material, which is initially soft, fills the spaces between teeth, hardens, and records the specific relationship of the arches. The hardened material is then transferred on to casts to be mounted on an articulator [5].
The accuracy of an interocclusal record, however, is influenced not only by the material properties, but also by the recording technique, as well as the reliability of the mandibular position influenced by the occlusal contacts, muscular action, or tissue changes within the joints [2, 6]. Oral rehabilitation involves a sequence of steps that must be followed in a highly judicious manner. This study was conducted to evaluate and compare the dimensional stability, accuracy and surface hardness of polyvinylsiloxane, zinc oxide eugenol and Aluwax at 1, 24, 48.62 h intervals.
Materials and Method
A stainless steel master die was prepared according to ADA specification no 19. Polyvinylsiloxane, Zinc oxide eugenol and Aluwax were manipulated according to manufacturer’s instructions and the specimens were prepared at room temperature. The die was covered with a 4 × 4 inches square glass slab. Hand pressure was applied over the glass slab for 5 s till the metal ring is seen; this was followed by application of a 500 g weight to further remove the excess material.
Then the mold, the stainless steel die and the weight were submerged in 36 ± 1°C water bath to simulate ambient temperature. Each assembly remained in the bath till the material sets plus an additional 3 min to ensure complete set of the material. Then the metal ring was removed from the stainless steel die and all the excess material (Flash) was removed by using a Bard parker knife no 15. The samples were stored at room temperature in a water proof container.
The prepared specimens were in the form of a disk measuring 0.3 cm in thickness and 3 cm in diameter with three parallel lines with a distance of 2.5 mm on the surface, these three lines were named as A, B and C. Then the ten samples were prepared with each material.
Measurement of the each samples were taken between the parallel lines A and C by means of travelling microscope with magnification of 10×. The distance between the two parallel reference lines A and C was measured at four fixed points. The mean of the four readings was taken for statistical analysis. Readings was recorded for all the ten samples of each group at an interval of 1, 24, 48, and 72 h. The mean of the distance between the lines A and C of each sample was compared to the corresponding measurement of 5000 × 200 μm in the standard stainless steel die measured under the travelling microscope.
The change in the dimension was calculated by the formula
![]() |
where X is the standard measurement (μm) of A–C in the die. Y is the observed measurement (μm) of A–C in the sample.
The same specimens were used to evaluate the accuracy of interocclusal recording materials. For this the B line which measures 0.2 mm depth has been standardized and measured using light section microscope with magnification of 200×.
The same specimens were used to evaluate the surface hardness of interocclusal recording materials using Shore hardness tester (shore A-round model, Mumbai-India). For testing of the specimens the depth indicator was set to zero. A light force was applied with the index finger to the indenter for 3 s and the unit was lowered on the sample until the presser foot is in full contact. The hardness value was displayed on the hardness tester. Four reading were taken on four different sites of the specimen and mean value was taken for statistical analysis.
Results
Statistical analysis was performed using one way analysis of variance (ANOVA) and multiple range tests (Tukey HSD-Honestly significant difference). The mean dimensional change, accuracy and surface hardness at various time intervals are shown in Tables and Figs. 1, 2, 3, 4, 5, 6, 7, 8, and 9.
Fig. 1.
Polyvinylsiloxane
Fig. 2.
Zinc-oxide eugenol
Fig. 3.
Aluwax
Fig. 4.
Master die
Fig. 5.
Samples
Fig. 6.
Thermostat
Fig. 7.
Travelling microscope
Fig. 8.
Light section microscope
Fig. 9.
Shore hardness tester
Table 1 shows the mean dimensional change of interocclusal record material in Group I is lesser than Group II and Group III. Also, the mean dimensional change in Group II is lesser than Group III at 1, 24, 48, 72 h interval. On statistical analysis the P value is <0.0001 which is significant at 5% level, so the results were found to be significant.
Table 1.
Comparison of dimensional change of three interocclusal record materials at various time intervals
| Duration (h) | Group | Mean ± SD | P value | Significant groupsa | |
|---|---|---|---|---|---|
| I vs. II, III | II vs. III | ||||
| 1 | I | 0.23 ± 0.11 | 0.0001 | 0.004 | I vs. II, III II vs. III |
| II | 0.44 ± 0.06 | ||||
| III | 0.58 ± 0.08 | ||||
| 24 | I | 0.49 ± 0.06 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 0.61 ± 0.08 | ||||
| III | 0.94 ± 0.08 | ||||
| 48 | I | 0.67 ± 0.09 | 0.0001 | 0.0001 | I vs. III II vs. III |
| II | 0.77 ± 0.12 | ||||
| III | 1.23 ± 0.08 | ||||
| 72 | I | 0.79 ± 0.08 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 1.05 ± 0.06 | ||||
| III | 1.46 ± 0.10 | ||||
a is significant among groups
Table 2 shows the mean accuracy of interocclusal record material in Group I is higher than Group II and Group III. Also, the mean accuracy in Group II is higher than Group III at 1, 24, 48, 72 h’s interval. On statistical analysis the P value is <0.0001 which is significant at 5% level. Hence, the results were found to be significant.
Table 2.
Comparison of accuracy of three interocclusal record materials at various time intervals
| Duration | Group | Mean ± SD | P value | Significant t groupsa | |
|---|---|---|---|---|---|
| I vs. II, III | II vs. III | ||||
| 1 h | I | 0.19 ± 0.001 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 0.18 ± 0.001 | ||||
| III | 0.17 ± 0.002 | ||||
| 24 h | I | 0.19 ± 0.001 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 0.18 ± 0.002 | ||||
| III | 0.16 ± 0.002 | ||||
| 48 h | I | 0.19 ± 0.002 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 0.18 ± 0.002 | ||||
| III | 0.16 ± 0.002 | ||||
| 72 h | I | 0.19 ± 0.002 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 0.18 ± 0.002 | ||||
| III | 0.16 ± 0.003 | ||||
a is significant among groups
Table 3 shows the mean surface hardness of interocclusal record material in Group I is higher than Group II and Group III. Also, the mean surface hardness in Group II is higher than Group III at 1, 24, 48, 72 h interval. On statistical analysis P value is <0.0001 which is significant at 5% level the results were found to be significant.
Table 3.
Comparison of surface hardness of three interocclusal record materials at various time intervals
| Duration | Group | Mean ± SD | P value | Significant groupsa | |
|---|---|---|---|---|---|
| I vs. II, III | II vs. III | ||||
| 1 h | I | 3.69 ± 0.06 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 3.10 ± 0.07 | ||||
| III | 2.10 ± 0.14 | ||||
| 24 h | I | 3.67 ± 0.04 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 3.33 ± 0.15 | ||||
| III | 2.12 ± 0.15 | ||||
| 48 h | I | 3.71 ± 0.05 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 3.31 ± 0.14 | ||||
| III | 2.09 ± 0.12 | ||||
| 72 h | I | 3.70 ± 0.05 | 0.0001 | 0.0001 | I vs. II, III II vs. III |
| II | 3.39 ± 0.12 | ||||
| III | 2.34 ± 0.13 | ||||
Group I: Polyvinyl siloxane, Group II Zinc oxide eugenol, Group III: Aluwax P value is <0.0001 which is significant at 5% level
a is significant among groups
Discussion
An accurate transfer of the intraoral maxilla-mandibular relationship to the articulator is essential for the fabrication of a prosthetic restoration [7]. When the teeth do not offer vertical and horizontal stability between the arches; an interocclusal record is needed to relate the casts. Precise articulation of a patient’s casts is a prerequisite for proper diagnosis and subsequent correct treatment. Apart from the operator’s clinical ability and the technique followed, the chosen material can critically affect the accuracy of the interocclusal registration [8].
According to Dawson [9] criteria for accuracy in making interocclusal records are
The recording material must not cause any movement of teeth or displacement of soft tissues.
The recording material must fit casts as accurately as it fits the teeth intra-orally.
The accuracy of the jaw relation record should check in the mouth and on the casts.
The linear dimensional change, accuracy and surface hardness of the interocclusal record materials were measured over time in this study. The above mentioned time intervals were based on the time required to carry the interocclusal record material to distant laboratory or the delay in the articulation of the cast in the laboratory [10]. Several factors contribute to the dimensional changes of the material used for interocclusal recording. The major factors being the loss of volatile substance over time [1]. The results showed that there is existence of correlation between the linear change and the weight loss due to volatiles [11].
Wax has gained wide acceptance for interocclusal record transfer, however complete closure into wax is not easily achieved and rarely registers accurate incisal and occlusal forms of teeth [12]. Studies showed that waxes contain aluminium or copper particles have flow rate of 2.5–22% at 37.5°C. So that they are susceptible to distortion upon removal from the mouth [13].
Zinc oxide eugenol paste is a reliable interocclusal recording material, however it dehydrates cracks and sticks to the teeth or the portions of the record can be lost through breakage. Zinc oxide eugenol record once used for mounting is rarely used also is advisable to use minimum amount of zinc oxide eugenol to avoid excess flash [14].
Polyvinylsiloxane is an accurate interocclusal recording material. However there is a “spring” to this elastomeric that can cause articulated casts to “open” in the centric closure position, also decided amount of friction in seating a stone model into these records polyvinylsiloxane presented the least linear changes of all the material tested. Polyvinylsiloxane was found to be the most accurate of all the material tested, at all time intervals followed by Zinc oxide eugenol and Aluwax respectively.
Polyvinyl siloxane possessed the highest hardness value among the three materials tested, at all time intervals followed by Zinc oxide eugenol and Aluwax respectively.
Wax showed the greatest linear changes of all the material tested in this study. This was attributed to the greater coefficient of thermal expansion and distortion due to the stress release [13]. The zinc oxide eugenol undergoes setting by chelation reaction. The by products of this reaction may undergo evaporation and this may contribute to their dimensional change. However, the eugenols free zinc oxide paste showed less dimensional change when compared to eugenol containing paste. In case of the polyvinylsiloxane, the excellent dimensional stability was attributed to the fact that it set by addition reaction. Hence there is no by products and loss of volatiles [11].
Indirectly made prostheses such as crowns and fixed partial dentures should be placed in the mouth without occlusal adjustments. To achieve this goal, an accurate interocclusal recording material with good dimensional stability is required.
Conclusion
Dimensional stability, accuracy and surface hardness of three interocclusal record materials are influenced by time factor.
Polyvinylsiloxane was more dimensionally stable when compared to zinc oxide eugenol, and Aluwax. Zinc oxide eugenol showed less dimensional change compared to Aluwax at 1, 24, 48, and 72 h.
Dimensional change and accuracy of polyvinyl siloxane material were statistically significant at 5% level but clinically insignificant.
The accuracy of polyvinylsiloxane was more compared to zinc oxide eugenol and Aluwax. Zinc oxide eugenol showed better accuracy than Aluwax at 1, 24, 48, and 72 h.
The surface hardness of polyvinylsiloxane was more compared to zinc oxide eugenol and aluwax. There was minimal change in the hardness of zinc oxide eugenol and aluwax after 48 h. The surface hardness of polyvinyl siloxane remains the same after 24 h.
Acknowledgments
I would like to express my deepest gratitude to Prof Dr. MuthuKumar. B, Prof Dr. K. Murugesan, Readers, Dr. Gopi chander and Dr. Ponsekar.A. Abraham, Department of prosthodontics, SRM dental college, Chennai for their immeasurable encouragement and guidance.
References
- 1.de Oliveira Pagnano V, Luiz Bezzon O, da Glória Chiarello de Mattos M, Ribeiro RF, Turbino ML. Clinical evaluation of interocclusal recording materials in bilateral free end cases. Braz Dent J. 2005;16(2):140–144. doi: 10.1590/s0103-64402005000200010. [DOI] [PubMed] [Google Scholar]
- 2.Ghazal M, Kern M. Mounting casts on an articulator using interocclusal records. J Prosthet Dent. 2008;100:408–409. doi: 10.1016/S0022-3913(08)60247-4. [DOI] [PubMed] [Google Scholar]
- 3.Warren K, Capp N. A review of principles and techniques for making interocclusal records for mounting working casts. Int J Prosthodont. 1990;3:341–348. [PubMed] [Google Scholar]
- 4.Pae A, Lee H, Kim HS. Effect of temperature on the rheological properties of dental interocclusal recording materials. Korea-Aust Rheol J. 2008;20(4):221–222. [Google Scholar]
- 5.Berry DC, Singh BP. Daily variations in occlusal contacts. J Prosthet Dent. 1983;50:386–391. doi: 10.1016/S0022-3913(83)80099-7. [DOI] [PubMed] [Google Scholar]
- 6.Lundeen HC. Centric relation records: the effect of muscle action. J Prosthet Dent. 1974;31:244–253. doi: 10.1016/0022-3913(74)90191-7. [DOI] [PubMed] [Google Scholar]
- 7.Freilich MA, Altieri JV, Wahle JJ. Principles for selecting interocclusal records for articulation of dentate and partially dentate casts. J Prosthet Dent. 1992;68:361–367. doi: 10.1016/0022-3913(92)90346-C. [DOI] [PubMed] [Google Scholar]
- 8.Michalakis KX, Pissiotis A, Anastasiadou V, Kapar D. An experimental study on particular physical properties of several interocclusal recording media. Part II: linear dimensional change and accompanying weight change. J Prosthodont. 2004;13(3):150–159. doi: 10.1111/j.1532-849X.2004.04024.x. [DOI] [PubMed] [Google Scholar]
- 9.Tripodakis AP, Vergos VK, Andreas G. Evaluation of the accuracy of interocclusal records in relation to two recording techniques. J Prosthet Dent. 1997;77:141–146. doi: 10.1016/S0022-3913(97)70227-0. [DOI] [PubMed] [Google Scholar]
- 10.Karthikeyan K, Annapoorani H. Comparative evaluation of dimensional stability of three types of interocclusal record materials: an in vitro study. J Indian Prosthodont Soc. 2007;7:24–27. doi: 10.4103/0972-4052.32513. [DOI] [Google Scholar]
- 11.Millstein PL, Clark RE, Myerson RL. Differential accuracy of silicone body interocclusal records and associated weight loss due to volatiles. J Prosthet Dent. 1975;33:649–654. doi: 10.1016/S0022-3913(75)80128-4. [DOI] [PubMed] [Google Scholar]
- 12.Millstein PL, Clark RE, Kronman JH. Determination of the accuracy of wax interocclusal registration Part II. J Prosthet Dent. 1971;25:189–196. doi: 10.1016/0022-3913(71)90107-7. [DOI] [PubMed] [Google Scholar]
- 13.Skurnik H. Resin registration for interocclusal records. J Prosthet Dent. 1977;37:164. doi: 10.1016/0022-3913(77)90238-4. [DOI] [PubMed] [Google Scholar]
- 14.Craig RG, Powers JM, Wataha JC. Dental materials properties and manipulation. 7. India: Harcourt private limited; 2001. [Google Scholar]










