Skip to main content
Journal of Interventional Gastroenterology logoLink to Journal of Interventional Gastroenterology
. 2011 Jan-Mar;1(1):8–13. doi: 10.4161/jig.1.1.14587

The water method significantly enhances proximal diminutive adenoma detection rate in unsedated patients

Felix W Leung 1,, Joseph W Leung 2,3, Rodelei M Siao-Salera 3, Surinder K Mann 2,3
PMCID: PMC3109471  PMID: 21686106

Abstract

Background

Colonoscopy has been reported to fail to prevent some post screening colonoscopy incident cancers or minimize cancer mortality in the proximal colon. These reports question the effectiveness of colonoscopy in detecting all proximal adenomas. Diminutive ones which can be obscured by residual feces are particularly at risk. The water method provides salvage cleansing of sub-optimal preparations.

Objective

To test the hypothesis that the water method enhances proximal diminutive adenoma detection rate (ADR).

Design

The data bases of two parallel RCT were combined and analyzed.

Setting

Two Veterans Affairs endoscopy units.

Patient and Methods

The water and air methods were compared in these two parallel RCT examining unsedated patients.

Main Outcome Measurements

The combined data on diminutive and overall ADR in the proximal colon, overall ADR, cecal intubation rate, withdrawal time and global bowel cleanliness score.

Results

Data in the water (n=92) and the air (n=90) groups were assessed. The water method yielded a significantly higher proximal diminutive ADR, 28.3% vs. 14.4% (p=0.0298); cecal intubation rate, 99% vs. 90% (p=0.0091); mean withdrawal time 19 (10) vs. 15 (8) min (p=0.0065) and mean global bowel cleanliness score during withdrawal, 2.6 (0.7) vs. 2.3 (0.6) (p=0.0032). Increase in proximal overall ADR in the water group approached significance, 29.3% vs. 16.7% (p=0.0592).

Limitation

Small number of predominantly male veterans.

Conclusion

The significantly higher cecal intubation rate, longer mean withdrawal time and better mean global bowel cleanliness score favor the outcome of significantly enhanced proximal diminutive ADR in the water group.

Key words: colorectal cancer screening, colonoscopy, water method, adenoma detection

Introduction

Colonoscopy has been reported to fail to prevent some post screening colonoscopy incident cancers or minimize cancer mortality in the proximal colon1,2. While the explanations are not fully available, these reports raise questions regarding the effectiveness of colonoscopy in detecting proximal adenomas which are presumptive precursors of cancers. Diminutive adenomas are particularly at risk of being obscured by residual feces. A water method to aid colonoscope insertion in unsedated patients involved warm water infusion in lieu of air insufflation, and suction removal of infused water and residual air to collapse the lumen to minimize discomfort38. A consecutive group observational study in a small number of unsedated patients revealed a numerically higher overall adenoma detection rate (ADR, proportion of patients with at least one adenoma of any size) in the water group (36.5% of 62 vs. 25.8% of 63; p=0.2474)5. Salvage cleansing was observed with poor bowel preparation in the water and the air groups being 1 of 62 and 8 of 63 patients (p=0.0325), respectively5. A retrospective study of sedated patients provided confirmatory ADR data with significantly higher ADR in the water than in the air group (34.9% of 495 vs. 26.8% of 683; p=0.0031)6. The retrospective data, however, were limited because cecal intubation rate, withdrawal time and quality of bowel preparation were not included. In the context of improving quality of screening colonoscopy9 these observations generated the hypothesis that the water method has the potential to increase ADR during withdrawal in screening patients6. We recently completed two parallel RCT in veterans accepting scheduled unsedated colonoscopy7 or the option of sedation on demand8. The significant impact of the water method on the primary outcomes in terms of attenuating discomfort7 or enhancing completion of unsedated colonoscopy8, respectively, has been reported. Neither outcome is considered measures of quality. On the other hand ADR is both a measure of quality9 and an independent predictor of risk of post screening colonoscopy cancer10. In the current report, we conducted an assessment of the combined data bases of these two RCT to optimize the sample size of patients randomized to be examined by equivalent water and air methods. We searched for evidence to support the hypothesis that the water method enhances proximal diminutive adenoma detection rate (ADR) in unsedated patients.

Methods

The air method during insertion

Minimal air insufflation was used to aid colonoscope insertion. Colonoscope shortening maneuver, abdominal compression by the assistant and change of patient position were utilized as needed. Contact with residual feces which would smear the lens and impair the view was avoided. Cecal intubation was defined as passage of the colonoscope tip to a point proximal to the ileocecal valve so that the entire cecal caput, including the medial wall of the cecum between the ileocecal valve and appendix orifice was visible9.

The water method during insertion

Unlike water-related techniques used as adjuncts to air insufflation, unique features of the water method38 are as follows. Warm water (normal water, not saline) was infused in lieu of air insufflation as the “principal modality” to decrease colonoscopy discomfort. With the help of a peristaltic pump water at 37°C (maintained by a water bath) was infused through the biopsy channel. Removal of residual air reduced angulations at the flexures (e.g. sigmoid, splenic, hepatic and redundant segments) and collapsed the colon around the colonoscope. The colonoscope tip was oriented towards the “slit-like lumen” ahead. The infused water opened the lumen if the orientation was correct. Water infusion was stopped if the orientation was incorrect. The tip of the colonoscope was pulled away from the mucosa and redirected. The colonoscope was advanced by repeated insertion and withdrawal motions of the colonoscope with a torque in the direction of the expected lumen, and intermittent water infusion. Suspended residual feces obscuring the view were suctioned and replaced by clean water until the colonic lumen was visualized again. The volume of water needed to clear the view was unrestricted; up to 200 (clean colon) to 2000 (dirty colon) ml was necessary. Most of the infused water in fact was aspirated into the suction bottle instead of remaining in the colon. Over-distension could be obviated. The cleansing effect serendipitously optimized the colonic mucosa for inspection. Insufflated air could lengthen the colon and exaggerate angulations at the flexures making insertion in the unsedated patient difficult. The air pump was turned off to avoid “accidental” air insufflation during insertion. Minimization of angulations at the sigmoid flexure by suction removal of residual air was well-explained by Mizukami et al.11. If advancement failed, the assistant would provide abdominal compression followed by the patient changing position if necessary. No abdominal pressure or change in patient position was employed if the advancement was uninterrupted. Cecal intubation was suggested in the early stage of development of the water method by appropriate movement of the endoscopic image on the monitor screen when the right lower quadrant was palpated, or ∼90 cm of the colonoscope in the short configuration was in the colon; and in the later stage, visualization of the appendix orifice under water. The cecum was then distended by air to confirm cecal intubation as defined above for the air method9.

In general there was not a lot of water leakage through the anus. We reported that “some patients did pass the water per anus as a bolus, requiring several large towels to soak up. We did not record the frequency of such occurrences, or survey the assistant specifically about the ‘mess’ created by such expulsions. We recorded assistant satisfaction after each colonoscopy. Despite an occasional ‘mess’ the responses significantly favored the water method.”7

Both methods during withdrawal

Air insufflation was used to distend the colon for inspection, biopsy and polypectomy. Washing of the stool covered mucosa and inspection behind folds were performed systematically. In the water group residual fluid around polyps was suctioned before polypectomy. Small polyps that dropped into nearby pool of fluid were retrieved by aspirating the fluid and polyps into the suction trap. After turn around in the rectum, residual air in the colon was removed by suction.

Study design

We searched the data bases of two recently reported RCT7,8. They were designed to determine if the water method significantly improved non ADR-related primary outcomes in veterans accepting the option of scheduled unsedated (NCT00747084) or on demand (NCT00920751) sedation colonoscopy. Each RCT was approved by local Institutional Review Board (IRB) — the VA Greater Los Angeles (VAGLAHS) and the Northern California (VANCHCS) Healthcare Systems, respectively. All participants signed consent before participation.

At the Sepulveda Ambulatory Care Center, VAGLAHS (11/07–4/09) enrolled veterans undergoing unsedated colonoscopy were randomized to the water (n=42) or air (n=40) group7. At the Sacramento Veterans Affairs Medical Center, VANCHCS (4/09–10/09), enrolled veterans accepting on demand sedation colonoscopy were randomized to the water (n=50) or air (n=50) group8. The impact of the water method on the primary outcomes of discomfort7 or completion of unsedated colonoscopy8, respectively, has been described. For the current report, we searched the de-identified data bases of these two RCT tabulating proximal (proximal to the splenic flexure) diminutive and proximal overall ADR, overall ADR for the entire colon, cecal intubation rate, withdrawal time and global bowel cleanliness scores.

The data were evaluated using intent-to-treat analysis of outcomes related to the index colonoscopy. Group means (SD) were compared using Student's t tests; and frequency counts (%), by Fisher's exact test. Two ways analysis of variance (ANOVA) was performed to assess the impact of the endoscopists or method on proximal diminutive ADR in the subgroup of screening colonoscopy patients.

Results

The two groups showed no significant difference in mean age, gender distribution, body mass index and indications for colonoscopy (Table 1). Cecal intubation rate was significantly higher in the water group compared to the air group, 99% vs. 90% (p=0.0091, Fisher's exact test). Cecal intubation and total procedure times were comparable; mean withdrawal time was significantly longer in the water group than the air group, 19 (10) vs. 15 (8) min; (p=0.0065, Student's t test). Volume of water used was significantly lower in the air group.

Table 1.

Patient age, colonoscopy indications and procedure-related outcomes in the air and water method groups

Air (n=90) Water (n=92) p
Age (years) 62.1 (8.7) 63.1 (8.7) 0.4175a
Gender (male/female) 88/2 91/1 0.6188b
Body mass index 30.4 (6.4) 29.4 (5.5) 0.2332a
Screening 52 (58%) 45 (49%) 0.2390b
Surveillance 29 (32%) 39 (42%) 0.1704b
Diagnostic (FOBT, BRBPR, etc.) 9 (10%) 8 (9%) 0.8037b
Other 1 (1.1%) 2 (2.2%) 1.0000b
Cecal intubation rate 81 of 90 (90%) 91 of 92 (99%) 0.0091b
Cecal intubation time (min) 21 (17), n=81 22 (15), n=91 0.6253a
Withdrawal time (min) 15 (8), n=81 19 (10), n=91 0.0065a
Total procedure time (min) 36 (20), n=81 41 (19), n=91 0.0966a
Volume of water used (ml) 109 (220) 1526 (656) 0.0001a

n, number of patients; FOBT, fecal occult blood test; BRBPR, bright red blood per rectum. Mean (SD) or frequency (%).

a

Student's t test;

b

Fisher's exact test.

The mean global bowel cleanliness scores during insertion were comparable between the air and water groups (Table 2). There was a significantly better mean global bowel cleanliness score in the water group than the air group during withdrawal, 2.6 (0.7) vs. 2.3 (0.6) (p=0.0032, Student's t test). The improvement in the water group was significant greater than that in the air group.

Table 2.

Global bowel cleanliness scores during insertion and withdrawal

Air (n=90) Water (n=92) pa
Insertion 2.2 (0.7) 2.1 (0.6) 0.1537
Withdrawal 2.3 (0.6) 2.6 (0.7) 0.0032
Change (withdrawal - insertion) 0.07 (0.3) 0.5 (0.5) 0.0001

n, number of patients. Mean (SD).

a

Student's t test. Global bowel cleanliness scores were defined as 4=excellent, no feces; 3=good, small amount of feces; 2=fair, moderate amount of feces; 1=poor, a lot of feces, including solid. The scores reflect the global impression of the colonoscopist during insertion and withdrawal.

There was a significantly higher proximal diminutive (<10 mm) ADR in the water group (28.3%) compared to the air group (14.4%) (p=0.0298, Fisher's exact test). Overall proximal ADR was numerically higher in the water group (29.3%) compared to the air group (16.7%); and the difference approached significance (p=0.0592, Fisher's exact test). Overall ADR was numerically higher in the water group, 38% vs. 30% but the difference was not statistically significant (p=0.2662, Fisher's exact test). Distal diminutive and distal overall ADR were not significantly different (Table 3).

Table 3.

ADR outcomes in the air and water method groups

Air (n=90) Water (n=92) pa
Proximal* (<10 mm) ADR 13 of 90 (14.4%) 26 of 92 (28.3%) 0.0298
Proximal* (>10 mm) ADR 2 of 90 (1.1%) 1 of 92 (1.0%) 0.6188
Overall Proximal* ADR 15 of 90 (16.7%) 27 of 92 (29.3%) 0.0592
Distal (<10 mm) ADR 6 of 90 (6.7%) 13 of 92 (14.1%) 0.1448
Distal (>10 mm) ADR 8 of 90 (8.9%) 4 of 92 (4.4%) 0.2466
Overall Distal ADR 14 of 90 (15.6%) 17 of 92 (18.5%) 0.6945
Overall ADR 27 of 90 (30%) 35 of 92 (38%) 0.2762

n, number of patients. ADR, adenoma detection rate defined as the proportion of patients with at least one adenoma of any size. Frequency (%).

*

Proximal to the splenic flexure.

a

Fisher's exact test.

Trainees were not involved in the studies. Three staff endoscopists performed all the colonoscopies. At one site screening, surveillance and diagnostic and at the other site only screening and surveillance colonoscopies were randomized. To address possible variations in ADR based on endoscopists' experience, a further subgroup analysis was performed using only the patients who underwent screening colonoscopy (Table 4). The method (p=0.0242, two way ANOVA) but not the endoscopists or the interaction between the method and the endoscopists was a significant factor in determining proximal diminutive ADR.

Table 4.

Effect of method and endoscopists on proximal diminutive ADR in patients undergoing screening colonoscopy

Endoscopist 1 Endoscopist 2 Endoscopist 3 Total
Method n ADR n ADR n ADR n ADR
Water 17 17.6% 16 12.5% 12 33.3% 45 20.0%
Air 19 5.3% 16 6.2% 17 5.9% 52 5.8%
Total 36 11.1% 32 9.4% 29 17.2% 97 12.4%

n, number of screening colonoscopies per group. ADR, refers to proximal diminutive (<10 mm) adenoma detection rate in this Table. Two way analysis of variance revealed the method produced a significant effect (p=0.0242) whereas endoscopists (p=0.4473) and interaction between method and endoscopists (p=0.4411) did not.

Discussions

This report demonstrates a significantly higher proximal diminutive ADR in predominantly unsedated patients examined by an insertion method distinct from usual air insufflation. An independent predictor of the risk of post screening colonoscopy cancer is ADR10. Colonoscopy has been reported to fail to completely eliminate some post screening colonoscopy incident cancers or reduce cancer mortality in the proximal colon1,2. Even diminutive adenomas can harbor malignancy8,1214. Inadequate bowel preparation can result in a cancer or important adenoma, particularly diminutive ones, hidden from view by feces. These observations support the need to evaluate simple, inexpensive, easily available method(s) that can increase proximal diminutive ADR. In the current report, the significantly higher proximal diminutive ADR in the water (28.3%) compared to the air (14.4%) group suggests adoption of the water method to aid insertion possibly may lead to improved quality of colonoscopy in unsedated patients. Confirmation of the efficacy of the water method in sedated patients will provide a plausible remedy for the draw back of colonoscopy in dealing with post screening colonoscopy incident cancers and cancer mortality in the proximal colon.

The air method associated with failed cecal intubation because of discomfort in the scheduled unsedated patients in specific, or incomplete visualization due to poor bowel preparation in general was less effective in detecting proximal diminutive adenomas7. The water method capable of enhancing cecal intubation by decreasing discomfort in the scheduled unsedated patient in specific, or salvage cleansing of the colon in general was more effective in detecting proximal diminutive adenomas7. Some of the sedation on demand patients (water group, 22% vs. air group, 46%, p=0.011) received sedation to achieve 100% cecal intubation8, dampening the full impact of the water method. Nonetheless, a significantly higher proximal diminutive ADR was observed in the water group.

The air group overall ADR of 30% (Table 3) is comparable to those in studies employing standard equipment and techniques in sedated patients1524 (Table 5). The water group overall ADR of 38% (Table 3) could possibly exceed those in studies employing chromoendoscopy and standard colonoscope in sedated patients25,26 (Table 5). The significantly longer withdrawal time in the water group is consistent with the association between prolonged withdrawal time and higher ADR21. The longer withdrawal time may also reflect more time spent in obtaining biopsy or polypectomy in the water group.

Table 5.

Recent published overall ADR in sedated patients

Method or subjects ADR Reference
Without trainee involvement 28% 15
Narrow band imaging 23% 16
Male non veterans 24.4% 17
High definition colonoscope 24.7% 18
Patients in Canada 25.5% 19
Patients in Israel 26% 20
Withdrawal time >6 min 28.3% 21
Three slow endoscopists after monitoring of ADR 28.9% 22
High definition colonoscope 28.8% 23
Morning colonoscopies 29.3% 24
Chromoendoscopy and standard colonoscope 33.6% 25
Chromoendoscopy and standard colonoscope 35.4% 26
White light and high definition colonoscope 41% to 57% 34
Narrow band imaging 51% 35
Chromoendoscopy and high definition colonoscope 55.5% 34

Adherence to suction removal of residual air and water exchange in the collapsed colonic lumen to clear the view likely optimized the soaking effect of water on residual feces adherent to mucosal surfaces. Residual feces were suspended in the luminal water by the turbulence set up by the simultaneous suction and infusion of water and readily removed during the insertion phase. The global bowel cleanliness score was significantly improved during withdrawal. One study of split-dose preparation producing superior cleanliness scores reported significantly higher polyp detection rate in those scored as fair/good (27.3%) or good/excellent (24.6%) compared with those rated as poor/fair (12.2%)27. Three studies of split-dose bowel preparation also reported better cleanliness although the impact on ADR was not addressed2830. One report did show split-dose significantly enhanced detection of flat lesions31. Same day bowel preparation yielded superior31,32 or equivalent33 bowel cleanliness compared with split-dose. To minimize bias in favor of the water method due to salvage cleansing in patients with suboptimal bowel preparation, split-dose or same day bowel preparation should be incorporated into future studies. The advent of modern endoscopic equipments has brought higher ADR with white light and high definition colonoscope34, narrow band imaging35 or chromoendoscopy and high definition colonoscope34 (Table 5). The hypothesis that the water method can enhance proximal diminutive ADR when these modern equipments are used deserves to be tested.

In contrast to recent reports on evaluation of enhancement of ADR in sedated patients by new technologies16,18,23,34,35, focus on the withdrawal phase10,21,22,25,26 and time of day24 of colonoscopy or timing of bowel preparation31 and removal of polyps during insertion36, we have described possible enhancement of proximal diminutive ADR on withdrawal in unsedated patients by the water method. Previous reports of worldwide availability of unsedated colonoscopy focused discussions on cecal intubation, patient tolerance, absence of sedation side-effects and potential cost savings37. There is a paucity of information on ADR in unsedated patients; reported polyp detection rates ranged from 19%38 and 20%39 to 34%40. Further evaluations of the impact of the water method on proximal diminutive ADR in the unsedated screening patients in diverse geographic and cultural settings are indicated. Similar comparisons in the sedated patients in the United States where sedation is the dominant practice may be worthwhile based on the results of a retrospective study6.

The strengths of this study are that the data are derived from the data bases of two parallel RCT comparing equivalent water and the air methods, and randomization has produced even distribution of demographic variables and indications for colonoscopy. The main limitation of this pilot report is the small number of predominantly male patients. The absence of blinding of the investigators (colonoscopist and assistant) is a drawback. In conclusion, the significantly higher cecal intubation rate, longer mean withdrawal time and better mean global bowel cleanliness score favor the outcome of significantly enhanced proximal diminutive ADR in the water group. Future studies extended to enroll larger numbers and subjects of both genders are warranted.

Acknowledgement

The study is supported in part by UC Davis C.W. Law Research Funds (JWL), VANCHCS medical research funds; 2009 ACG Clinical Research Award (FWL), 1985 ASGE Career Development Award (FWL) and VAGLAHS medical research funds.

Abbreviations

ADR

adenoma detection rate

SD

standard deviation

VAMC

Veterans Affairs Medical Center

Footnotes

Previously published online: www.landesbioscience.com/journals/jig

Disclosure

The authors have no conflict of interests to disclose relevant to this study.

References

  • 1.Baxter NN, Goldwasser MA, Paszat LF, Saskin R, Urbach DR, Rabeneck L. Association of colonoscopy and death from colorectal cancer. Ann Intern Med. 2009;150:1–8. doi: 10.7326/0003-4819-150-1-200901060-00306. [DOI] [PubMed] [Google Scholar]
  • 2.Brenner H, Hoffmeister M, Arndt V, Stegmaier C, Altenhofen L, Haug U. Protection from right- and left-sided colorectal neoplasms after colonoscopy: population-based study. J Natl Caner Inst. 2010;102:89–95. doi: 10.1093/jnci/djp436. [DOI] [PubMed] [Google Scholar]
  • 3.Leung JW, Mann S, Leung FW. Option for screening colonoscopy without sedation — a pilot study in United States veterans. Aliment Pharmacol Ther. 2007;26:627–631. doi: 10.1111/j.1365-2036.2007.03404.x. [DOI] [PubMed] [Google Scholar]
  • 4.Leung JW, Mann SK, Siao-Salera R, Ransibrahmanakul K, Lim B, Cabrera H, et al. A randomized, controlled comparison of warm water infusion in lieu of air insufflation versus air insufflation for aiding colonoscopy insertion in sedated patients undergoing colorectal cancer screening and surveillance. Gastrointest Endosc. 2009;70:505–510. doi: 10.1016/j.gie.2008.12.253. [DOI] [PubMed] [Google Scholar]
  • 5.Leung FW, Aharonian HS, Leung JW, Guth PH, Jackson G. Impact of a novel water method on scheduled unsedated colonoscopy in U.S. veterans. Gastrointest Endosc. 2009;69:546–550. doi: 10.1016/j.gie.2008.08.014. [DOI] [PubMed] [Google Scholar]
  • 6.Leung JW, Do L, Siao-Salera RM, Parikh DA, Mann SK, Leung FW. Retrospective data showing the water method increased adenoma detection rate — a hypothesis generating observation. J Interventional Gastroenterol. 2010;1:3–7. doi: 10.4161/jig.1.1.14585. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Leung FW, Harker JO, Jackson G, Okamoto KE, Behbahani OM, Jamgotchian NJ, et al. A proof-of-principle, prospective, randomized, controlled trial demonstrating improved outcomes in scheduled unsedated colonoscopy by the water method. Gastrointest Endosc. 2010;72:693–700. doi: 10.1016/j.gie.2010.05.020. [DOI] [PubMed] [Google Scholar]
  • 8.Leung JW, Mann SK, Siao-Salera RM, Ransibrahmanakul K, Lim BS, Canete W, et al. A randomized, controlled trial to confirm the beneficial effects of the water method on U.S. veterans undergoing colonoscopy with the option of on-demand sedation. Gastrointest Endosc. 2011;73:103–110. doi: 10.1016/j.gie.2010.09.020. [DOI] [PubMed] [Google Scholar]
  • 9.Rex DK, Petrini JL, Baron TH, Chak A, Cohen J, Deal SE, et al. Quality indicators for colonoscopy. Am J Gastroenterol. 2006;101:873–885. doi: 10.1111/j.1572-0241.2006.00673.x. [DOI] [PubMed] [Google Scholar]
  • 10.Kaminski MF, Regula J, Kraszewska E, Polkowski M, Wojciechowska U, Didkowska J, et al. Quality indicators for colonoscopy and the risk of interval cancer. New Engl J Med. 2010;362:1795–1803. doi: 10.1056/NEJMoa0907667. [DOI] [PubMed] [Google Scholar]
  • 11.Mizukami T, Yokoyama A, Imaeda H, Kumai K. Collapse-submergence method: simple colonoscopic technique combining water infusion with complete air removal from the rectosigmoid colon. Dig Endosc. 2007;19:43–47. [Google Scholar]
  • 12.Hurlstone DP, Cross SS, Slater R, Sanders DS, Brown S. Detecting diminutive colorectal lesions at colonoscopy: a randomized controlled trial of pan-colonic versus targeted chromoscopy. Gut. 2004;53:376–380. doi: 10.1136/gut.2003.029868. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Hornick JL, Farraye FA, Odze RD. Clinicopathologic and immunohistochemical study of small apparently “de novo” colorectal adenocarcinomas. Am J Surg Pathol. 2007;31:207–215. doi: 10.1097/01.pas.0000213383.17418.a9. [DOI] [PubMed] [Google Scholar]
  • 14.Butterly LF, Chase MP, Pohl H, Fiarman GS. Prevalence of clinically important histology in small adenomas. Clin Gastroenterol Hepatol. 2006;4:343–348. doi: 10.1016/j.cgh.2005.12.021. [DOI] [PubMed] [Google Scholar]
  • 15.Rogart JN, Siddiqui UD, Jamidar PA, Aslanian HR. Fellow involvement may increase adenoma detection rates during colonoscopy. Am J Gastroenterol. 2008;103:2841–2846. doi: 10.1111/j.1572-0241.2008.02085.x. [DOI] [PubMed] [Google Scholar]
  • 16.Adler A, Aschenbeck J, Yenerim T, Mayr M, Aminalai A, Drossel R, et al. Narrow-band versus white-light high definition television endoscopic imaging for screening colonoscopy: a prospective randomized trial. Gastroenterology. 2009;136:410–416. doi: 10.1053/j.gastro.2008.10.022. [DOI] [PubMed] [Google Scholar]
  • 17.Chen SC, Rex D. Endoscopist can be more powerful than age and male gender in predicting adenoma detection at colonoscopy. Am J Gastroenterol. 2007;102:856–861. doi: 10.1111/j.1572-0241.2006.01054.x. [DOI] [PubMed] [Google Scholar]
  • 18.Burke CA, Choure AG, Sanaka MR, Lopez R. A comparison of high-definition versus conventional colonoscopes for polyp detection. Dig Dis Sci. 2010;55:1716–1720. doi: 10.1007/s10620-009-0941-y. [DOI] [PubMed] [Google Scholar]
  • 19.Bair D, Pham J, Seaton MB, Arya N, Pryce M, Seaton TL. The quality of screening colonoscopies in an office-based endoscopy clinic. Can J Gastroenterol. 2009;23:41–47. doi: 10.1155/2009/831029. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Strul H, Kariv R, Leshno M, Halak A, Jakubowicz M, Santo M, et al. The prevalence rate and anatomic location of colorectal adenoma and cancer detected by colonoscopy in average-risk individuals aged 40–80 years. Am J Gastroenterol. 2006;101:255–262. doi: 10.1111/j.1572-0241.2006.00430.x. [DOI] [PubMed] [Google Scholar]
  • 21.Barclay RL, Vicari JJ, Doughty AS, Johanson JF, Greenlaw RL. Colonoscopic withdrawal times and adenoma detection during screening colonoscopy. New Engl J Med. 2006;355:2533–2541. doi: 10.1056/NEJMoa055498. [DOI] [PubMed] [Google Scholar]
  • 22.Lin OS, Kozarek RA, Arai A, Gluck M, Jiranek GC, Kowdley KV, et al. The effect of periodic monitoring and feedback on screening colonoscopy withdrawal times, polyp detection rates, and patient satisfaction scores. Gastrointest Endosc. 2010;71:1253–1259. doi: 10.1016/j.gie.2010.01.017. [DOI] [PubMed] [Google Scholar]
  • 23.Buchner AM, Shahid MW, Heckman MG, McNeil RB, Cleveland P, Gill KR, et al. High-definition colonoscopy detects colorectal polyps at a higher rate than standard white-light colonoscopy. Clin Gastroenterol Hepatol. 2010;8:364–370. doi: 10.1016/j.cgh.2009.11.009. [DOI] [PubMed] [Google Scholar]
  • 24.Sanaka MR, Deepinder F, Thota PN, Lopez R, Burke CA. Adenomas are detected more often in morning than in afternoon colonoscopy. Am J Gastroenterol. 2009;104:1659–1664. doi: 10.1038/ajg.2009.249. [DOI] [PubMed] [Google Scholar]
  • 25.Park SY, Lee SK, Kim BC, Han J, Kim JH, Cheon JH, et al. Efficacy of chromoendoscopy with indigocarmine for the detection of ascending colon and cecum lesions. Scand J Gastroenterol. 2008;43:878–885. doi: 10.1080/00365520801935442. [DOI] [PubMed] [Google Scholar]
  • 26.Pohl J, Lotterer E, Balzer C, Sackmann M, Schmidt KD, Gossner L, et al. Computed virtual chromoendoscopy versus standard colonoscopy with targeted indigocarmine chromoscopy: a randomised multicentre trial. Gut. 2009;58:73–78. doi: 10.1136/gut.2008.153601. [DOI] [PubMed] [Google Scholar]
  • 27.Marmo R, Rotondano G, Riccio G, Marone A, Bianco MA, Stroppa I, et al. Effective bowel cleansing before colonoscopy: a randomized study of split-dosage versus non-split dosages regimens of high-volume versus low-volume polyethylene glycol solutions. Gastrointest Endosc. 2010;72:313–320. doi: 10.1016/j.gie.2010.02.048. [DOI] [PubMed] [Google Scholar]
  • 28.Park JS, Sohn CI, Hwang SJ, Choi HS, Park JH, Kim HJ, et al. Quality and effect of single dose versus split dose of polyethylene glycol bowel preparation for early-morning colonoscopy. Endoscopy. 2007;39:616–619. doi: 10.1055/s-2007-966434. [DOI] [PubMed] [Google Scholar]
  • 29.Rostom A, Jolicoeur E, Dube C, Gregoire S, Patel D, Saloojee N, et al. A randomized prospective trial comparing different regimens of oral sodium phosphate and polyethylene glycol—based lavage solution in the preparation of patients for colonoscopy. Gastrointest Endosc. 2006;64:544–552. doi: 10.1016/j.gie.2005.09.030. [DOI] [PubMed] [Google Scholar]
  • 30.Rex DK, Di Palma JA, Rodriguez R, McGowan J, Cleveland M. A randomized clinical study comparing reduced-volume oral sulfate solution with standard 4-liter sulfate-free electrolyte lavage solution as preparation for colonoscopy. Gastrointest Endosc. 2010;72:328–336. doi: 10.1016/j.gie.2010.03.1054. [DOI] [PubMed] [Google Scholar]
  • 31.Parra-Blanco A, Nicolas-Perez D, Gimeno-Garcia A, Grosso B, Jimenez A, Ortega J, et al. The timing of bowel preparation before colonoscopy determines the quality of cleansing, and is a significant factor contributing to the detection of flat lesions: A randomized study. World J Gastroenterol. 2006;12:6161–6166. doi: 10.3748/wjg.v12.i38.6161. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Varughese S, Kumar AR, George A, Castro FJ. Morning-only one-gallon polyethylene glycol improves bowel cleansing for afternoon colonoscopies: A randomized endoscopist-blinded prospective study. Am J Gastroenterol. 2010;105:2368–2374. doi: 10.1038/ajg.2010.271. [DOI] [PubMed] [Google Scholar]
  • 33.Matro R, Shnitser A, Spodik M, Daskalakis C, Katz L, Murtha A, et al. Efficacy of morning-only compared with split-dose polyethylene glycol electrolyte solution for afternoon colonoscopy: a randomized controlled single-blind study. Am J Gastroenterol. 2010;105:1954–1961. doi: 10.1038/ajg.2010.160. [DOI] [PubMed] [Google Scholar]
  • 34.Kahi CJ, Anderson JC, Waxman I, Kessler WR, Imperiale TF, Li X, et al. High-definition chromocolonoscopy vs. high-definition white light colonoscopy for average-risk colorectal cancer screening. Am J Gastroenterol. 2010;105:1301–1307. doi: 10.1038/ajg.2010.51. [DOI] [PubMed] [Google Scholar]
  • 35.Inoue T, Murano M, Murano N, Kuramoto T, Kawakami K, Abe Y, et al. Comparative study of conventional colonoscopy and pan-colonic narrow-band imaging system in the detection of neoplastic colonic polyps: a randomized, controlled trial. J Gastroenterol. 2008;43:45–50. doi: 10.1007/s00535-007-2125-x. [DOI] [PubMed] [Google Scholar]
  • 36.Morini S, Hassan C, Zullo A, Lorenzetti R, de Matthaeis M, Stella F, et al. Detection of colonic polyps according to insertion/withdrawal phases of colonoscopy. Int J Colorectal Dis. 2009;24:527–530. doi: 10.1007/s00384-009-0633-2. [DOI] [PubMed] [Google Scholar]
  • 37.Leung FW, Aljebreen AM, Brocchi E, Chang EB, Liao WC, Mizukami T, et al. Sedation risk-free colonoscopy for minimizing the burden of colorectal cancer screening. World J Gastrointest Endosc. 2010;2:81–89. doi: 10.4253/wjge.v2.i3.81. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Thiis-Evensen E, Hoff GS, Sauar J, Vatn MH. Patient tolerance of colonoscopy without sedation during screening examination for colorectal polyps. Gastrointest Endosc. 2000;52:606–610. doi: 10.1067/mge.2000.109804. [DOI] [PubMed] [Google Scholar]
  • 39.Hoffman MS, Butler TW, Shaver T. Colonoscopy without sedation. J Clin Gastroenterol. 1998;26:279–282. doi: 10.1097/00004836-199806000-00013. [DOI] [PubMed] [Google Scholar]
  • 40.Ristikankare M, Hartikainen J, Heikkinen M, Janatuinen E, Julkunen R. Is routinely given conscious sedation of benefit during colonoscopy? Gastrointest Endosc. 1999;49:566–572. doi: 10.1016/s0016-5107(99)70383-4. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Interventional Gastroenterology are provided here courtesy of Taylor & Francis

RESOURCES