. 2011 Oct;26(5):615–621. doi: 10.1089/cbr.2011.0965

Comparison of I-131 Radioimmunotherapy Tumor Dosimetry: Unit Density Sphere Model Versus Patient-Specific Monte Carlo Calculations

David M Howard 1, Kimberlee J Kearfott 1, Scott J Wilderman 2, Yuni K Dewaraja 2,
PMCID: PMC3189007  PMID: 21939358

Abstract

High computational requirements restrict the use of Monte Carlo algorithms for dose estimation in a clinical setting, despite the fact that they are considered more accurate than traditional methods. The goal of this study was to compare mean tumor absorbed dose estimates using the unit density sphere model incorporated in OLINDA with previously reported dose estimates from Monte Carlo simulations using the dose planning method (DPMMC) particle transport algorithm. The dataset (57 tumors, 19 lymphoma patients who underwent SPECT/CT imaging during I-131 radioimmunotherapy) included tumors of varying size, shape, and contrast. OLINDA calculations were first carried out using the baseline tumor volume and residence time from SPECT/CT imaging during 6 days post-tracer and 8 days post-therapy. Next, the OLINDA calculation was split over multiple time periods and summed to get the total dose, which accounted for the changes in tumor size. Results from the second calculation were compared with results determined by coupling SPECT/CT images with DPM Monte Carlo algorithms. Results from the OLINDA calculation accounting for changes in tumor size were almost always higher (median 22%, range −1%–68%) than the results from OLINDA using the baseline tumor volume because of tumor shrinkage. There was good agreement (median −5%, range −13%–2%) between the OLINDA results and the self-dose component from Monte Carlo calculations, indicating that tumor shape effects are a minor source of error when using the sphere model. However, because the sphere model ignores cross-irradiation, the OLINDA calculation significantly underestimated (median 14%, range 2%–31%) the total tumor absorbed dose compared with Monte Carlo. These results show that when the quantity of interest is the mean tumor absorbed dose, the unit density sphere model is a practical alternative to Monte Carlo for some applications. For applications requiring higher accuracy, computer-intensive Monte Carlo calculation is needed.

Key words: radiation dosimetry, radioimmunotherapy, SPECT, Monte Carlo dosimetry

Introduction

Radiolabeled antibody therapy, including I-131 radioimmunotherapy (RIT), has shown much success in the treatment of malignancies such as non-Hodgkin's lymphoma (NHL).1,2 The potential exists to further improve the efficacy of these therapies by individualized, dosimetry-based treatment planning. Thus, there is much interest in the accurate assessment of the radiation absorbed dose delivered to normal organs and tumor during therapy.

Conventionally, dosimetry in internal emitter therapy has been based on the S-value formalism developed by the Medical Internal Radiation Dose (MIRD) Committee.3 Here, the absorbed dose to a target region from decays in a given source region is expressed as the product of the cumulated activity in the source region and the source-to-target S-value, which is the absorbed dose to the target region per unit cumulated activity in the source region. The total absorbed dose to a target is then calculated as the sum of contributions from self-irradiation (where target and source regions are the same) and from cross-irradiation (where target and source regions are different). The S-values for such calculations have been predetermined by Monte Carlo methods, originally for the “Reference Man” anatomy4 and later for stylized models representing individuals of both sexes at several ages.5 A major limitation of using reference S-values for absorbed dose estimation in patients is the potential for a significant difference between organ geometries of the individual patient and those of the models used to generate the S-values. In addition, the models of the human anatomy used to determine S-values do not include tumor, because tumors can be of arbitrary shape, size, and location within the anatomy.

For tumor dosimetry, the conventional approach has been based on a sphere model that assumes that tumors are isolated unit density spheres in an infinite unit density medium. This approach has been implemented in the OLINDA/EXM code,6 which is often used for dosimetry calculations in internal emitter therapy. For any of the radionuclides included in the program, S-values for self-irradiation of unit density spheres are available for discrete sphere masses in the range 0.01–6000 g. These S-values have been precalculated based on the most recent evaluation of electron- and photon-absorbed fractions in spheres of various sizes.7 Because organ-to-tumor cross-dose depends almost exclusively on the proximity of tumor relative to the organ and because tumor locations are arbitrary, organ-to-tumor S-values cannot be calculated for the general case. Therefore, dose estimates from this approach will account only for the self-dose and not for any cross-dose from any extratumor activity.

To overcome the obvious limitations of the simplistic sphere model, researchers have turned to other more patient-specific approaches to tumor dosimetry.813 One such approach is the dose point-kernel method, which is based on convolving the spatial distribution of activity with tabulated dose point-kernels for a specific isotope.14 This method tends to be inaccurate when there are tissue inhomogeneities such as at tissue–air and tissue–bone interfaces.14 Loudos et al.15 have recently developed a patient-specific dosimetry method based on modifying tabulated dose point-kernels to account for the spatial variation in densities (derived from patient CTs) between source and target voxel centers. This method was not considered in this work as it was felt that the increased accuracy obtained by using a Monte Carlo-based dosimetry model outweighed the relatively modest computation time penalty incurred.

The more sophisticated of the patient-specific tumor dosimetry methods couples 3D anatomical (from MRI or CT) and functional (from SPECT or PET) images of the patient with explicit Monte Carlo radiation-transport calculations. In a recent publication, highly patient-specific tumor dose assessment results for 60 tumors in 20 NHL patients who underwent I-131 tositumomab RIT were reported.12 Dose assessment was carried out by coupling SPECT/CT imaging data at multiple time points with the Dose Planning Method Monte Carlo (DPMMC) radiation transport algorithm.13 The voxel-level calculations were carried out, including deformable image registration to relate tumor voxels that are changing from one time point to another because of tumor regression or deformation. Registered tumor dose-rate maps were integrated over time to obtain the 3D dose distribution, which allowed for calculation of not only mean absorbed dose to the tumor but also other summary measures such as maximum dose and equivalent uniform dose. Such patient-specific dose assessment provides 3D dose distributions and is more accurate than a calculation based on reference S-values. However, 3D imaging data are needed, in addition to high computational requirements. With recent advances in computer power and acceleration of Monte Carlo algorithms, these calculations can be carried out in a research environment, but such calculations are still not practical for the clinic. Therefore, when the quantity of interest is the mean absorbed dose to the target, comparison of results from patient-specific Monte Carlo calculations with results using reference S-values is clinically relevant to determine the level of accuracy that can be achieved with the simpler approach. Previous reports on such comparisons have either focused on organ dosimetry or were limited to simulated tumor geometries.16,17 The goal of the present study is to compare mean tumor absorbed dose estimates using the unit sphere model incorporated in OLINDA with dose estimates from previously reported Monte Carlo calculations for NHL patients. Unlike previous reports, the present study uses actual patient SPECT/CT imaging data and tumors of varying size, shape, and uptake relative to background for this comparison.

Materials and Methods

Patient imaging data

The imaging data came from patients undergoing 131 I-tositumomab therapy of relapsed or refractory B-cell lymphoma under an approved clinical protocol. The clinical treatment protocol1 and the SPECT/CT imaging procedure under a research protocol11,12 have been previously described in detail and are summarized here. The administered diagnostic (tracer) activity was 185 MBq (5 mCi) and the therapy activity ranged from 2.15 to 5.68 GBq (58–153 mCi). For the research study, patients volunteered for imaging at multiple time points on the Siemens Symbia TruePoint SPECT/CT scanner. Patients were imaged three times following the tracer (days 0, 2, and 6) and three times following the therapy (days 2, 5, and 7–9). At each time point, a nuclear medicine specialist with radiology CT training defined the tumor volumes of interests on CT, plane by plane. Data for 60 tumors in 20 patients (13 men and 7 women; age range, 33–81 years) were available for the present calculations. One of these patients (patient 17 in Table 1), who developed human anti-mouse antibodies, had too few SPECT counts to perform dosimetry, so 19 patients with a total of 57 tumors were analyzed.

Table 1.

Comparison of Different Dose Estimation Techniques for 57 Tumors Found in 19 Patients

 
 
 
 
 
Tumor absorbed dose calculated using OLINDA (cGy)
Percentage of difference between doses from Monte Carlo and from OLINDA approach 2
Subject Tumor name Initial tumor volume (mL) Decrease in tumor volumea(%) Bb Approach 1 (using baseline tumor mass) Approach 2 (accounting for mass change) Comparison to self-dose from Monte Carloc Comparison to total dose from Monte Carloc
1 Pelvis 400 5 3 125 129 −5 18
2 Paraaortic 409 15 6 229 227 −8 17
3 Inguinal 140 49 7 153 231 −6 7
  Iliac 234 45 7 140 218 −9 5
4 Pelvis big 314 31 15 361 407 −7 6
  Pelvis small 39 27 14 380 387 −5 10
5 Renal 58 62 4 246 274 −5 23
  L paraaortic 34 67 4 201 243 −5 23
  Central 21 50 4 222 252 −5 27
  Hepatic 19 62 3 210 263 −5 28
  Crux 10 57 4 164 234 −4 26
6 L iliac 34 81 10 171 352 −5 9
  Paraaortic 74 65 9 160 335 −10 13
7 R inguinal up 16 42 8 147 188 −2 15
  R inguinal big 71 37 9 190 235 −5 10
  R inguinal small 24 44 4 59 84 −4 23
  L inguinal up 11 39 9 129 183 −1 12
  L inguinal big 114 43 10 187 252 −5 3
  L inguinal small 22 55 7 100 164 −3 14
8 R inguinal lateral 5 80 3 62 135 2 21
  R inguinal medial 7 73 7 175 316 0 13
  R iliac 54 77 6 161 296 −8 13
  R aorta 79 67 7 193 328 −8 10
  R anterior acetab. 34 87 7 148 332 −6 11
  R posterior acetab. 44 85 6 130 325 −6 14
  L acetabulum 31 79 7 142 355 −5 16
9 R inguinal 12 46 4 63 93 −2 18
  L inguinal 19 28 4 71 85 −3 16
  L iliac 35 31 4 81 101 −6 19
10 R anterior iliac 45 50 12 317 380 −6 8
  R posterior iliac 54 56 11 246 348 −7 14
  R inguinal 76 31 11 324 352 −7 2
11 L kidney up 7 53 11 300 503 −1 13
  L kidney down 15 34 10 386 507 −2 10
  R psoas 113 7 10 508 536 −7 5
12 Para vertebral 28 34 4 150 181 −7 26
13 Hilar spleen 7 64 5 213 283 −2 28
  L Dph 36 60 3 154 215 −5 28
  L paraaortic 84 43 4 199 233 −9 24
  L psoas 36 39 3 171 200 −8 20
  R Dph down 6 35 4 164 209 −4 31
  R Dph up 27 49 3 167 210 −5 29
  R paraaortic 97 32 4 211 250 −9 23
14 L neck up 3 20 5 175 180 −1 16
  L neck mid 2 11 7 245 255 0 13
  L neck down 2 53 8 281 308 2 13
15 Central 18 40 5 233 334 −7 27
16 Abdominal 423 18 3 144 150 −5 24
17 Speen 157 25 NA NA NA NA NA
  L pelvis 135 50 NA NA NA NA NA
  L Ex 19 66 NA NA NA NA NA
18 Lung 151 81 2 53 167 −6 30
19 L neck 12 41 4 221 354 −13 13
20 L iliac 7 42 9 235 298 −4 13
  L inguinal inferior 45 43 9 269 351 −6 7
  R iliac 12 32 19 630 670 −1 6
  R inguinal inferior 34 36 15 453 535 −3 3
  R inguinal lateral 5 30 9 263 311 2 15
  R inguinal medial 14 57 13 340 493 0 7
  R inguinal superior 5 53 7 159 246 2 17
a

Percentage of difference in tumor volume defined on first post-tracer SPECT/CT and last post-therapy SPECT/CT (a time period of approximately 15 days).

b

Tumor–to–rest-of-the-body activity concentration ratio.

c

Difference calculated as 100×(Monte Carlo −OLINDA)/Monte Carlo.

Tumor time–activity curves

The 3D SPECT reconstruction and activity quantification have been previously described11,12 and are summarized here. SPECT data were reconstructed with 35 iterations (6 subsets) of 3D ordered-subsets expectations maximization (OSEM) including triple-window-based scatter correction, CT-based attenuation correction, and compensation for 3D depth-dependent detector response. At each time point, the SPECT counts within the CT-defined tumor volume were converted to an activity using a calibration factor. Correction for partial volume effects was carried out by applying volume-dependent recovery coefficients determined from phantom experiments.12 Tumor time–activity data were generated for both tracer and therapy administrations. For the present study, the rest-of-the-body time–activity curves were not needed, as only the self-dose is determined in the OLINDA calculation. Time–activity data were fitted using a biexponential of the form Inline graphic.18 This function was analytically integrated over time to obtain the tumor residence time (cumulated activity divided by the administered activity) for the dosimetry calculations discussed later. The endpoint of the integration was somewhat arbitrarily chosen as 300 hours. The 300 hours time was selected, because the last imaging time point was typically about 150 hours postadministration for tracer and 190 hours postadministration for therapy and extrapolating too far from that time point could lead to greater variance in the results. The residence times when the time–activity curve was integrated to infinity were within 5% of the values obtained by integrating to 300 hours for every tumor except one (patient 11, R psoas in Table 1). The activity clearance of this tumor was unusually slow, resulting in a residence time 53% higher when integrated to infinity. The 300 hours integration is consistent with the previous study in which Monte Carlo dose-rate maps were integrated up to this time to obtain the dose map.12

Although much emphasis was placed on accurate SPECT activity quantification using state-of-the-art hybrid imaging and 3D OSEM reconstruction, inaccuracies can remain because of approximations made when correcting for physical factors, uncertainty in tumor volume determination, SPECT-CT misregistration, and the limited imaging time points. These inaccuracies will have a similar impact on the two absorbed dose calculation methods compared in the present work, because tumor time–activity data were generated in the same manner for both calculations.

Tumor dosimetry using the unit density sphere model

For tumor dosimetry, the unit density sphere model implemented within OLINDA was used. Here, tumors are approximated as unit density spheres with uniformly distributed activity. The precalculated OLINDA sphere-model S-factors for I-131 were obtained for all available sphere sizes ranging from 0.01 to 6000 g. These S-values were plotted vs. sphere mass and the fitted function was used to determine the S-value for any mass. The dose equation based on the MIRD formalism can be expressed as follows:

graphic file with name M2.gif (1)

Here, τ is the residence time, Ã is the cumulated activity, A0 is the patient's administered activity, and S is the dose per unit cumulated activity.

The dosimetry calculation was carried out with and without accounting for changes in tumor size measured at the multiple imaging time points. In the first approach, the absorbed dose was estimated for a constant tumor mass corresponding to the outline defined on the day 0 post-tracer SPECT/CT (baseline mass). The tracer residence time was determined by integrating the tracer time–activity curve from 0 to 300 hours, and the therapy residence time was determined by integrating the therapy time–activity curve from 0 to 300 hours. To estimate the mean tumor absorbed dose from the tracer administration, the S-value corresponding to the baseline tumor mass and the tracer residence time were used in Equation 1. To estimate the mean tumor absorbed dose from the therapy administration, the S-value corresponding to the baseline tumor mass and the therapy residence time were used in Equation 1.

The availability of SPECT/CT imaging data and CT-defined tumor outlines at multiple time points favor splitting the OLINDA calculation over multiple time periods, which was done in the second approach. As imaging was carried out at three time points, three time periods were used for the calculation. A typical tumor time–activity curve with the three time periods (0 to t1, t1 to t2, t2 to 300 hours) is shown in Figure 1. Here, T1, T2, and T3 are the three imaging time points, t1 is the midpoint between T1 and T2, and t2 is the midpoint between T2 and T3. The total dose was calculated as the sum of the dose delivered over each of the three periods:

graphic file with name M3.gif (2)

FIG. 1.

FIG. 1.

A typical tumor time–activity curve showing the biexponential fit and the three time periods used for the OLINDA calculation over multiple time periods to account for the measured changes in tumor size. The %ID is the percentage of activity normalized by the injected activity.

where τ1, τ2, and τ3 are the residence times for the three time periods determined by integrating the time–activity curve over each period, and S1, S2, and S3 are the OLINDA S-values corresponding to the tumor masses outlined at imaging time points T1, T2, and T3, respectively. This calculation was carried out separately for the tracer and the therapy imaging data.

The dosimetry results from the OLINDA calculation carried out over multiple time periods according to Equation 2 were used for the comparison to the previous Monte Carlo results as this approach is more consistent with how the SPECT/CT data were previously utilized (SPECT/CT images and tumor outlines from each of the time points were input to the DPMMC algorithm to generate corresponding tumor dose-rate maps).12

Results

Typical patient SPECT/CT images with tumor outlines are shown in Figure 2. The tumor dosimetry results for all tumors are given in Table 1, together with other relevant information useful for interpreting the dosimetry results. The tumor-to-background activity concentration ratio, B, is the activity per voxel in the tumor divided by the activity per voxel in the rest of the body (“rest of the body” was defined as the total body section within the SPECT camera field of view minus the tumor). Also given in Table 1 are the baseline tumor volume defined on the first SPECT/CT and the decrease in tumor volume between this time point and the last SPECT/CT time point. The study included a wide range of tumor sizes (initial volume, 2–423 mL), tumor locations, and a wide range of B-values (2–19). Hence, there was a wide range in the level of cross-irradiation. The mean tumor absorbed dose results given in Table 1 are the total delivered from both the tracer and therapy administrations. Results from the OLINDA calculation using a baseline tumor mass and results from the OLINDA calculation carried out over the multiple time periods, accounting for changes in tumor mass, are given. Tumor absorbed doses calculated accounting for the mass changes were almost always higher than the absorbed doses calculated assuming a baseline tumor mass. The difference between the two OLINDA calculations ranged from −1% to 68%, with a median difference of 22%. The mean absorbed dose accounting for mass change was significantly higher than the mean absorbed dose without accounting for this change (p<0.001, paired t-test).

FIG. 2.

FIG. 2.

SPECT/CT images with outlines for inguinal tumor (A), anterior iliac tumor (B, upper outline), and posterior iliac tumor (B, lower outline). Images are for subject 10 in Table 1.

Next, the comparison between the mean tumor absorbed dose results from OLINDA and the previously reported Monte-Carlo-based, patient-specific calculation is presented in Table 1. (Note that results from the OLINDA calculation over multiple time periods were used for this comparison.) OLINDA results were compared with both the self-dose and the total dose (sum of self-dose and cross-dose components) from the Monte Carlo calculation. Almost always, the OLINDA results were higher than the Monte Carlo self-dose, but only slightly. Although the mean absorbed self-dose from OLINDA was significantly higher than the mean absorbed self-dose from Monte Carlo (p<0.001, paired t-test), the difference between these two calculations was small, ranging from −13% to 2%, with a median difference of only −5%. The OLINDA results were always lower than the Monte Carlo total dose, and the difference between the two ranged from 2% to 31%, with a median difference of 14%. The mean absorbed dose from OLINDA was significantly lower than the mean absorbed total dose from Monte Carlo (p<0.001, paired t-test).

Discussion

For most of the 57 tumors, significant tumor shrinkage was measured during the SPECT/CT imaging. Because of the inverse relationship between absorbed dose and mass, the OLINDA calculation carried out over multiple time periods gave significantly higher (up to 68%) absorbed doses than the calculation assuming baseline tumor masses. Conventionally, tumor dosimetry in internal emitter therapy has been carried out assuming a constant tumor mass, typically obtained from a diagnostic CT study performed before the treatment. The present results demonstrate the inadequacy of such an approach for dosimetry of malignant lymphoma, which can have dramatic shrinkage within days of the treatment.12,19 When tumor volume information from multiple time points is available, a reasonable approach is to carry out the OLINDA calculation over multiple time periods as in the present study.

The unit density sphere model implemented within OLINDA assumes all tumors are spherical, whereas the DPM Monte Carlo calculation utilizes the actual tumor contour outlined on CT. In all cases, the DPMMC self-dose was lower than the OLINDA calculation, because in reality tumors are nonspherical (see e.g., Fig. 2) and more beta particles can escape from a nonspherical geometry without depositing all of their energy compared with a spherical geometry of the same volume. However, the relatively good agreement between the OLINDA results and the DPMMC self-dose results (see Table 1) shows that the sphere approximation is reasonable and shape effects are not a major source of error. This is due to the I-131 beta emission, which has a mean energy of 192 keV and has a short range (2.3 mm20 in water) compared to the size of the tumors of the present dataset (smallest radius around 8 mm, 16 times larger than the range of the beta particle). Shape effects may lead to more errors in calculations for Y-90 RIT, which has a higher energy beta emission (mean energy of 938 keV), leading to a greater range in water (11.3 mm20). In Table 1, the comparison between OLINDA results and the total DPMMC absorbed doses showed significant differences (up to 31%). As expected, the total DPMMC dose was higher, because the sphere model ignores the contribution from activity outside the sphere. In general, the difference between results of DPMMC and OLINDA increases as the tumor-to-background activity concentration ratio (B-value in Table 1) decreases because of the increasing contribution from cross-irradiation. There are, however, exceptions, because the contribution to tumor dose from cross-irradiation depends not only on the B-value but also on the size of the tumor and the proximity of the tumor to structures with significant uptake. As calculated, the B-value assumes a uniform activity distribution in the rest of the body, but in reality there is enhanced I-131 uptake in the liver, kidneys, spleen, and heart. In addition, the contribution from cross-irradiation is very much dependent on the photon energy, and hence, the trends observed in the present I-131 study may not be applicable to therapies with other radionuclides.

In a previous study, the photon contribution to tumor dose from I-131 activity outside the tumor was calculated by Monte Carlo for simulated tumors positioned in the Reference Man geometry.16 The underestimation of tumor dose due to neglecting this contribution was found to be in the range 10%–20%, which is comparable to the results of the present study. In a more recent study, focusing mainly on normal organ dosimetry Divoli et al.17 reported on the differences between results obtained using patient-specific Monte Carlo methodology and results obtained using the reference S-values implemented in OLINDA. Individual patient's CT images (total of 9 patients) were used to define the normal organs, whereas published biodistribution data were used to assign cumulated activities. When a mass correction (available in OLINDA) was used to account for differences in organ masses between the patient and the standard model, good agreement (within 5%) was demonstrated. For normal organs, agreement between the two calculations can be expected to be better than the agreement for tumor, because the cross-irradiation contribution is included in the OLINDA calculation for normal organs. The work by Divoli et al. also included tumor, but was limited to two small (7 g each) spherical tumors, artificially placed in the liver and the lung. The good agreement (<5%) between Monte Carlo and OLINDA in that reported for tumor was attributed to the limited nature of the study. Tumors of different size, shape, and varying levels of uptake relative to background were not investigated as in the present work.

Conclusions

For NHL patients treated with I-131 tositumomab RIT, the mean tumor absorbed doses determined using the unit density sphere model in OLINDA were compared with previously reported results from explicit Monte Carlo simulation using the DPMMC algorithm. SPECT/CT imaging data from multiple time points were used in both calculations. The dataset included tumors of varying sizes and shapes as well as varying uptake relative to the rest of the body. There was good agreement when the OLINDA results were compared with the self-dose component from the Monte Carlo calculation, indicating that assuming a spherical shape for the tumor was not a major source of error. However, because the sphere model ignores cross-irradiation, this calculation significantly underestimated (median 14%, range 2%–31%) the total absorbed dose compared with Monte Carlo. Although the tumor dosimetry calculation using the sphere model is much more practical than the computer-intensive Monte Carlo method, its level of accuracy may not be acceptable for some treatment planning applications.

Acknowledgments

This work was supported by grant 2R01 EB001994 awarded by the National Institutes of Health, United States Department of Health and Human Services (Bethesda, MD).

Disclaimer

The contents of this article are solely the responsibility of the authors and do not necessarily represent the official views of the funding agencies.

Conflict of Interest

The authors declare that they have no conflict of interest.

References

  • 1.Kaminski MS. Tuck M. Estes J, et al. 131I-tositumomab therapy as initial treatment for follicular lymphoma. N Engl J Med. 2005;352:441. doi: 10.1056/NEJMoa041511. [DOI] [PubMed] [Google Scholar]
  • 2.Vose JM. Wahl RL. Saleh M, et al. Multicenter phase II study of iodine-131 tositumomab for chemotherapy-relapsed/refractory low-grade and transformed low-grade B-cell non-Hodgkin's lymphomas. J Clin Oncol. 2000;18:1316. doi: 10.1200/JCO.2000.18.6.1316. [DOI] [PubMed] [Google Scholar]
  • 3.Loevinger R. Budinger TF. Watson EE. MIRD Primer for Absorbed Dose Calculations. New York: Society of Nuclear Medicine; 1991. [Google Scholar]
  • 4.Snyder WS. Ford MR. Warner GG, et al. New York: Society of Nuclear Medicine; 1975. MIRD Pamphlet 11: “S,” Absorber Dose Per Unit Cumulated Activity For Selected Radionuclide and Organs. [Google Scholar]
  • 5.Cristy M. Eckerman KF. Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources. Oak Ridge, TN: Oak Ridge National Laboratory, ORNL/TM-8381 V1-V7; 1987. [Google Scholar]
  • 6.Stabin MG. Sparks RB. Crowe E. OLINDA/EXM: The second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023. [PubMed] [Google Scholar]
  • 7.Stabin MG. Konijnenberg MW. Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes. J Nucl Med. 2000;41:149. [PubMed] [Google Scholar]
  • 8.Johnson TK. MABDOS: A generalized program for internal radionuclide dosimetry. Compu Methods Prog Biomed. 1988;27:159. doi: 10.1016/0169-2607(88)90027-2. [DOI] [PubMed] [Google Scholar]
  • 9.Yoriyaz H. Stabin MG. dos Santos A. Monte Carlo MCNP-4B-based absorbed dose distribution estimates for patient-specific dosimetry. J Nucl Med. 2001;42:662. [PubMed] [Google Scholar]
  • 10.Sgouros G. Squeri S. Ballangrud AM, et al. Patient-specific, 3-dimensional dosimetry in non-Hodgkin's lymphoma patients treated with 131I-anti-B1 antibody. Assessment of tumor dose-response. J Nucl Med. 2003;44:260. [PubMed] [Google Scholar]
  • 11.Dewaraja YK. Wilderman SJ. Koral KF, et al. Use of integrated SPECT/CT imaging for tumor dosimetry in I-131 radioimmunotherapy: A pilot patient study. Cancer Biother Radiopharm. 2009;24:417. doi: 10.1089/cbr.2008.0568. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Dewaraja YK. Schipper MJ. Roberson PL, et al. 131I-tositumomab radioimmunotherapy: Initial tumor dose-response results using 3-dimensional dosimetry including radiobiologic modeling. J Nucl Med. 2010;51:1155. doi: 10.2967/jnumed.110.075176. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Wilderman SJ. Dewaraja YK. Method for fast CT/SPECT based 3D Monte Carlo absorbed dose computations in internal emitter therapy. IEEE Trans Nucl Sci. 2007;54:146. doi: 10.1109/TNS.2006.889164. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Bolch WE. Bouchet LG. Robertson JS, et al. MIRD Pamphlet No. 17: The Dosimetry of Nonuniform Activity Distributions—Radionuclide S Values at Voxel Level. J Nucl Med. 1999;40:11. [PubMed] [Google Scholar]
  • 15.Loudos G. Tsougos I. Boukis S, et al. A radionuclide dosimetry toolkit based on material-specific Monte Carlo dose kernels. Nuc Med Commun. 2009;30:504. doi: 10.1097/MNM.0b013e3283299a11. [DOI] [PubMed] [Google Scholar]
  • 16.Johnson TK. Colby SB. Photon contribution to tumor dose from considerations of 131I radiolabeled antibody uptake in liver, spleen, and whole body. Med Phys. 1993;20:1667. doi: 10.1118/1.596953. [DOI] [PubMed] [Google Scholar]
  • 17.Divoli A. Chiavassa S. Ferrer L, et al. Effect of patient morphology on dosimetric calculations for internal irradiation as assessed by comparisons of Monte Carlo versus conventional methodologies. J Nucl Med. 2009;50:316. doi: 10.2967/jnumed.108.056705. [DOI] [PubMed] [Google Scholar]
  • 18.Schipper MJ. Avram AM. Kaminski MS, et al. I-131 Radioimmunotherapy: Prediction of tumor level therapy absorbed dose from the tracer study via a mixed model fit of time-activity. Annual Meeting of the Society of Nuclear Medicine. J Nucl Med. 2010;51:23. [Google Scholar]
  • 19.Hartmann Siantar CL. DeNardo GL. DeNardo SJ. Impact of nodal regression on radiation dose for lymphoma patients after radioimmunotherapy. J Nucl Med. 2003;44:1322. [PubMed] [Google Scholar]
  • 20.Prestwich WV. Nunes J. Kwok CS. Beta dose point kernels for radionuclides of potential use in radioimmunotherapy. J Nucl Med. 1989;30:1036. [PubMed] [Google Scholar]

Articles from Cancer Biotherapy & Radiopharmaceuticals are provided here courtesy of Mary Ann Liebert, Inc.