Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2012 Dec 1.
Published in final edited form as: Ophthalmology. 2011 Dec;118(12):2398–2402. doi: 10.1016/j.ophtha.2011.05.013

The relationship between glaucoma medication adherence, eye drop technique, and visual field defect severity

B Sleath 1, Susan Blalock 1, David Covert 2, Jennifer L Stone 3, Asheley Cockrell Skinner 4, Kelly Muir 5, Alan L Robin 6
PMCID: PMC3223548  NIHMSID: NIHMS297274  PMID: 21856009

Abstract

Objective

The purpose of the study was to examine: (a) how patient adherence and eye drop technique were associated with visual field defect severity and (b) how general glaucoma adherence self-efficacy and eye drop technique self-efficacy were related to visual field defect severity.

Design

Cross-sectional study conducted at a single private practice site.

Participants

Patients on eye drops for their glaucoma.

Methods

We measured subjects’ adherence to glaucoma medications through Medication Events Monitoring System (MEMS) devices and assessed eye drop instillation technique by video-recording. We measured general glaucoma medication adherence self-efficacy using a 10-item scale and eye drop technique self-efficacy using a 6-item scale. Multivariable logistic regression was used to analyze the data.

Main outcome measures

Visual field defect severity.

Results

Patients who were less than 80% adherent according to the MEMS caps were significantly more likely to have worse defect severity. Patients with lower scores on the general glaucoma medication adherence self-efficacy scale were also significantly more likely to have worse defect severity. Eye drop technique and eye drop technique self-efficacy were not significantly related to visual field defect severity.

Conclusions

Eye care providers need to assess patient adherence and work with those patients with poor adherence to find ways to improve their ability and self-efficacy in using their glaucoma medications.

Background

Poor adherence to the prescribed glaucoma regimen has been described for many years13 and more recent work suggests that the correlation between a provider’s estimate of a patient’s medication adherence and the actual measured adherence of the same patient is quite poor.4 Accordingly, there has been an increased interest in the study of glaucoma medication adherence.514 A direct association has been found between patient adherence and patient outcomes in other chronic diseases such as diabetes, asthma, and hypertension1518 but, to our knowledge, very little work has examined the relationship between glaucoma medication adherence and visual field defect severity in glaucoma.1, 1921

Glaucoma medication adherence can be measured in several ways, including self-report, pharmacy refill reports, electronic monitoring, and direct observation.15 It remains unclear which method of measuring adherence correlates best with clinically significant outcomes. For example, Konstas et al.19 found that patients with self-reported non-adherence to their glaucoma eye drops had worse visual field loss. Rossi et al.22 found, using an electronic monitor of adherence, that patients with a stable visual field over a one year period had a median adherence rate of 85% and patients who worsened had a median adherence rate of 21%. In another study, worse medication adherence as measured by electronic monitors was associated with a trend towards worse visual field scores.21 Stone et al23 found a trend towards better eye drop instillation technique for patients with milder glaucoma severity

Observation of eye drop instillation technique and self-reported adherence are methods of measuring adherence that are available to the provider in a clinical setting, but self-report often overestimates adherence.24 However, there are two instruments, the general glaucoma medication self-efficacy scale and the eye drop technique self-efficacy scale that can easily be used in practice.8, 25 These instruments’ scoring results have been shown to be significantly related to actual glaucoma medication adherence and eye drop technique respectively.25

The purpose of this study was to examine: (a) how patient adherence and eye drop technique were associated with visual field defect severity and (b) how general glaucoma adherence self-efficacy and eye drop technique self-efficacy were related to visual field defect severity.

Methods

Design

This study was conducted at a single private practice site and used a cross-sectional design. All eligible patients were approached for enrollment. Charts were pre-screened by study staff prior to the patient’s regularly scheduled appointment based on the appointment schedule for that day. All subjects were consented prior to enrollment and the protocol followed the tenets of the Declaration of Helsinki; the study was approved by the Southwest Independent Institutional Review Board, Fort Worth, TX and adhered to the Health and Insurance Portability and Accountability Act.

Procedures

During the initial visit, subjects completed a demographic questionnaire and then demonstrated their typical eyedrop instillation technique while being video-recorded (Xacti C5 VPC-C5; Sanyo Electric Co. Ltd, Osaka, Japan). All subjects instilled drops from a sterile 5 mL low-density polyethylene bottle filled with sterile artificial tears. Subjects were issued an activated Medication Event Monitoring System (MEMS) cap device and medication vial for each bottle of hypotensive eyedrops used. This method of assessing adherence has been successfully used in prior research.11 All subjects were educated on the correct use of the MEMS cap device and were instructed not to alter their usual, prescribed treatment regimen. At the subsequent 1 month follow-up visit, subjects were given a glaucoma medication self-efficacy questionnaire to complete and all MEMS cap devices were checked for battery life and proper recording functions. Subjects returned all MEMS caps at the 3 month visit and any subject without a current visual field (within 9 months of enrollment) underwent testing at that time.

Study Population

We included all consecutive subjects with a diagnosis of glaucoma, who were using 1 or more topical hypotensive medications in one or both eyes. Subjects were only excluded if they did not instill their own medications, if they could not come to all follow-up study visits, or if they had a known hypersensitivity to over-the-counter artificial tears. Subjects were required to have had a complete ophthalmic exam within the preceding 6 months.

Measurement

Subject Characteristics

We measured both age and years of education as continuous variables. Self-reported race was originally measured as a categorical variable and then was dichotomized for the multivariable analyses (i.e., White, non-White). Gender was measured as a dichotomous variable. The number of glaucoma medications a subject was taking was measured as a continuous variable and then recoded into one versus two or more for the multivariable analyses. Length of time with glaucoma was measured with the following response categories: two years or less, more than two years to less than five years, five years or more.

Visual field defects were classified as mild (mean deviation ≥ -6dB), moderate (mean deviation < -6 but > -12dB), or severe (mean deviation ≤-12dB) according to Hodopp-Anderson criteria.25 One visual field was used in this study, only the most recent (within 9 months of enrollment) was allowed and testing strategies varied based on what was appropriate for the patient’s severity of defect (24-2 or 10-2) or h/o reliability (SS vs. SITA-Fast). Only SITA strategies were used from the HVF-A machine. If a recent (9 months) visual field was not available, the patient then completed testing during study enrollment. The reliability parameters of less than 20% errors were used.

Eye drop instillation technique

Subjects were first escorted to a dedicated exam room with a sink, soap, towels and mirror readily available; they were uniformly instructed to instill the artificial tears just as they would instill their medications at home. The entire process was digitally video-recorded. Prior to analysis of the recordings, a comprehensive list of items associated with eye drop instillation techniques was developed, based on prior research.23 One researcher (AS) who was unfamiliar with the subjects was trained by another author (JS) to code and review all recordings in accordance with previous studies. Perfect instillation technique was defined as being to instill a single drop in the eye on the first attempt without touching one’s face, eye, or eyelid.

Medication adherence

Medication adherence over a three month period was evaluated via electronic data from the MEMS caps system (Aradex).11 Adherence using MEMS caps was measured using the following formula: adherence = (number of doses used during the past three months divided by the number of prescribed doses) multiplied by 100. If the subject was on more than one glaucoma medication, an overall percent adherence variable was created by adding together the subject’s adherence for each glaucoma medication and dividing it by the number of glaucoma medications the subject was using. We dichotomized the variable because the variable was skewed towards patients being highly adherent. Subjects were considered adherent if they used 80% or more of the prescribed doses (79.5% or above was rounded to 80% or more) and they were classified as non-adherent if they used less than 80% of the prescribed doses as suggested in prior research.27

Glaucoma medication self-efficacy questionnaire

A 16-item glaucoma medication self-efficacy questionnaire was completed by the subjects. The questionnaire had two subscales, a 10-item general glaucoma medication adherence self-efficacy scale and a 6-item eye drop technique self-efficacy scale.25 The scale is available for public use; please contact the first author for a copy. There were four possible response choices for the self-efficacy items: not at all confident, somewhat confident, very confident, and does not apply. The subscales have strong psychometric properties.8, 25 The general medication adherence self-efficacy scale has been found to be strongly associated with adherence assessed via MEMS caps and the eye drop technique self-efficacy scale has been found to be strongly associated with video-taped eye drop technique.8, 25

Analysis

First, we present descriptive statistics. Second, we examined the bivariate relationships between the variables using Pearson correlation coefficients, chi-square statistics, and t-tests. Since 70 patients had mild defect severity, 13 had moderate defect severity, and 19 had severe defect severity, for the multivariable analyses we recoded defect severity into a dichotomous variable (mild versus moderate/severe) which did not change our results and made them easier to interpret.

We conducted a multivariable logistic regression to examine how the demographic characteristics (gender, age, race, years of education, number of glaucoma medications, length of time with glaucoma) were associated with visual field defect severity. Next, we added whether the patients had perfect eye drop technique according to the video-tapes and whether the patients were 80% or more adherent to their glaucoma medications according to the MEMS caps to the regression. In a different multivariable logistic regression we added patient scores on the eye drop technique and general glaucoma medication adherence self-efficacy scales instead of the objective measures of eye drop technique and adherence.

Results

One hundred and two subjects participated and their demographic characteristics are presented in Table 1. One half of the sample was male, two-thirds were white and subjects ranged in age from 40 to 90 years. The majority of subjects (93.1%) had glaucoma in both eyes. Forty-eight percent of the sample used only one glaucoma medication. The majority of subjects (69%) had mild visual field defect severity.

Table 1.

Subject Characteristics (N=102)

Gender Percent (N)
  Male 50.0 (51)
Race 67.6 (69)
  White 26.5 (27)
  Black 2.9 (3)
  Asian 2.9 (3)
  Other
Duration of glaucoma
  2 years or less 10.8 (11)
  More than 2 years to less than 5 years 16.7 (17)
  5 years or more 72.5 (74)
Eye(s) affected by glaucoma
  Right 6.9 (7)
  Left 0.0 (0)
  Both 93.1 (95)
Number of different glaucoma medications used
  One 48.0 (49)
  Two 38.2 (39)
  Three 9.8 (10)
  More than three 3.9 (4)
Visual Field Defect Severity
  Mild 68.6 (70)
  Moderate 12.7 (13)
  Severe 18.6 (19)
Range; Mean (standard deviation)
Age
  40–90 years 67.27 (11.1)
Years of education
  6–30 years 15.47 (3.69)

Eighty percent of subjects successfully instilled a drop in their eye on the first attempt as graded in the video-recordings. Seventy percent of subjects instilled only a single drop. Thirty-four percent of subjects touched their eye or eyelash with the eye drop bottle and 52% of subjects touched their face with the eye drop bottle. Only thirty-eight percent of the patients had perfect drop technique in the video-recordings.

Eighty-nine percent of the patients were 80% or more adherent to their eye drops according to the MEMS caps. Patient scores on the general medication adherence self-efficacy scale ranged from 11 to 30 (mean= 27.64 standard deviation= 3.72). Patient scores on the eye drop technique self-efficacy scale ranged from 8 to 18 (mean=16.34, standard deviation= 2.20).

Table 2 presents the logistic regression results predicting worse visual field defect severity. First, we entered just the demographic characteristics into model one. Non-white patients were significantly more likely to have worse defect severity than White patients (odds ratio=0.33, 95% confidence interval=0.12, 0.89). Patients on two or more glaucoma medications were significantly more likely to have worse defect severity than patients on one glaucoma medication (odds ratio=2.62, 95% confidence interval=1.01, 6.79).

Table 2.

Multivariable logistic regression results predicting moderate/severe defect severity (N=102)

Independent Variables Model One
OR (95% CI)
Model Two
OR (95% CI)
Age 1.04 (0.99, 1.10) 1.07 (0.99, 1.13)
Years of education 0.93 (0.81, 1.05) 0.91 (0.80, 1.05)
Gender-female 1.35 (0.53, 3.45) 1.45 (0.52, 4.01)
Race – white 0.33 (0.12, 0.89)* 0.57 (0.19, 1.66)
# glaucoma medications 2.62 (1.01, 6.79)* 2.65 (0.95, 7.36)
How long have had glaucoma 0.91 (0.46, 1.82) 1.01 (0.84, 7.72)
Video-taped eye drop technique-perfect ----- 2.55 (0.84, 7.72)
Electronically measured adherence- 80% or more ----- 0.14 (0.03, 0.81)*
*

p< 0.05

OR=odds ratio 95% CI=95% confidence interval

Next, we added whether the patient had perfect eye drop technique according to the video-tapes and whether the patient was 80% or more adherent to their glaucoma medications according to the MEMS caps into model two. Video-taped eye drop technique was not significantly associated with visual field defect. Patients who were less adherent had worse visual fields than patients who were more adherent (odds ratio=0.14, 0.03, 0.81). Patient race and whether the patient was on one versus two or more glaucoma medications were no longer significantly associated with visual field defect once patient adherence was added into the model. Patient race was significantly associated with adherence (Pearson chi-square=5.51, p=0.02), which could explain why it became non-significant when adherence was entered into the model. Whether the patients were on one versus two or more glaucoma medication was not significantly associated with adherence (Pearson chi-square=0.67, p=0.41).

Table 3 presents the logistic regression results predicting worse defect severity. This time we entered the patient scores on the eye drop technique self-efficacy scale and the general glaucoma medication adherence scale (rather than the objective measures of eye drop technique and adherence) into the logistic regression equation after we entered the demographic characteristics. The general glaucoma medication adherence self-efficacy scale was significantly associated with visual field defect (odds ratio=0.17, 95% confidence interval=0.04, 0.76).

Table 3.

Multivariable logistic regression results predicting moderate/severe defect severity (N=102)

Independent Variables Model One
OR (95% CI)
Model Two
OR (95% CI)
Age 1.04 (0.99, 1.10) 1.04 (0.99, 1.09)
Years of education 0.93 (0.81, 1.05) 0.91 (0.79, 1.04)
Gender-female 1.35 (0.53, 3.45) 2.01 (0.71, 5.70)
Race – white 0.33 (0.12, 0.89)* 0.33 (0.12, 0.92)*
# glaucoma medications 2.62 (1.01, 6.79)* 2.38 (0.88, 6.43)
How long have had glaucoma 0.91 (0.46, 1.82) 1.37 (0.59, 3.17)
Eye drop technique self-efficacy ----- 0.83 (0.20, 3.35)
General medication adherence self-efficacy ----- 0.17 (0.04, 0.76)*
*

p< 0.05

OR=odds ratio 95% CI=95% confidence interval

Patients who reported higher general glaucoma medication adherence self-efficacy had better visual fields than patients who reported lower general glaucoma medication adherence self-efficacy. We believe the self-report measure correlated well with MEMS cap adherence and visual field defect severity because it measured self-efficacy or self-confidence in being adherent to glaucoma medications rather than asking them how many doses they missed. Perhaps people are more likely to respond more honestly when they are asked how confident they feel when it comes to adherence rather than asking them how many doses they missed. Whether the patients were on one versus two or more glaucoma medications was not significantly associated with glaucoma medication self-efficacy (t-test=0.86, p=0.39). The eye drop technique self-efficacy scale was not significantly associated with visual field defect severity.

Patient race remained significantly associated with visual field defect severity even after the general glaucoma medication adherence self-efficacy scale scores were added into the model. Patient race and patient scores on the general glaucoma medication adherence self-efficacy scores were not significantly associated with each other. The number of glaucoma medications the patient was on was no longer significantly associated with visual field defect when the general glaucoma medication adherence self-efficacy scores were added into the model. However, number of glaucoma medications remained close to significance (p=0.08).

Discussion

We found that non-Whites (primarily African Americans) were significantly more likely to be less than 80% adherent to their glaucoma medications according to the MEMS caps than Whites. This finding is similar to those of other researchers who have found that non-Whites are less adherent to glaucoma medications than Whites.7, 21, 28

Being non-White was also significantly related to having worse visual field defect severity until actual adherence was controlled for in the regression equation. Providers need to work with all patients, especially non-White patients, to try to improve adherence to glaucoma medications to prevent further vision loss. Future research needs to test interventions that attempt to improve patient adherence, especially in African American patients.

Patients who used two or more glaucoma medications had worse visual field defect severity than patients on one medication. This is most likely because providers add more medications to a patient’s regimen as their defect severity gets worse.

We also found that patient scores on the 10-item general glaucoma medication adherence scale were strongly associated with worse visual field defect severity. The self-efficacy instrument could be used by clinicians to identify patients who do not feel confident taking their glaucoma medications under certain circumstances. Providers could pinpoint the problem based on patients’ responses and help address the specific challenge.

It is interesting that actual eye drop technique and reported eye drop technique self-efficacy were not associated with visual field defect severity. This does not mean that eye drop technique is not important, but it does show that motivating patients to adhere to their treatment regimens is more important than patients having perfect eye drop technique. Providers need to educate patients on the importance of adherence and they need to work with patients to problem solve and eliminate any barriers that patients report experiencing when using their glaucoma medications.

It is interesting that the general medication self-efficacy measure correlated well with MEMS cap adherence and visual field defect severity. This might be because we measured self-efficacy or self-confidence in being adherent to glaucoma medications rather than asking patients how many doses they missed. Perhaps people are more likely to respond more honestly when they are asked how confident they feel when it comes to adherence rather than asking them how many doses they missed.

This study has several limitations. First, although most subjects were willing to participate, we did not track the characteristics of those subjects who choose not to participate in the study. Second, the study was conducted at a single site, which may limit broad applications of these findings. Third, the high level of adherence is this study (89% of patients were 80% or more adherent) may have been a drawback in evaluation of the non-adherent group (unequal sample size). Despite these limitations, the study found an association between poor adherence to glaucoma medications and patients having a worse visual field. It also found an association between general glaucoma medication adherence self-efficacy and patients having a worse visual field.

Acknowledgments

Financial Support: Funding for this research was provided by Alcon Research, Ltd. The sponsor participated in the design of the study and review of the manuscript.

Dr. Sleath was also supported by grant EY018400 from the National Eye Institute and by grant UL 1RR02574 7 from the National Center of Research Resources, NIH. NIH had no role in the design or conduct of this research.

Footnotes

Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

No conflict of author exists for any author.

Financial Disclosure(s): Betsy Sleath, Susan Blalock, Alan Robin, Kelly Muir, Asheley Skinner, and Jennifer Stone were consultants for Alcon Pharmaceuticals.

References

  • 1.Spaeth GL. Visual loss in a glaucoma clinic. I. Sociological considerations. Invest Ophthalmol. 1970;9:73–82. [PubMed] [Google Scholar]
  • 2.Norell SE, Granstrom PA. Self-medication with pilocarpine among outpatients in a glaucoma clinic. Br J Ophthalmol. 1980;64:137–141. doi: 10.1136/bjo.64.2.137. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Kass MA, Hodapp E, Gordon M, et al. Part I. Patient administration of eyedrops: interview. Ann Ophthalmol. 1982;14:775–779. [PubMed] [Google Scholar]
  • 4.Okeke CO, Quigley HA, Jampel HD, et al. Adherence with topical glaucoma medication monitored electronically: the Travatan Dosing Aid study. Ophthalmology. 2009;116:191–199. doi: 10.1016/j.ophtha.2008.09.004. [DOI] [PubMed] [Google Scholar]
  • 5.Lu VH, Goldberg I, Lu CY. Use of glaucoma medications: state of the science and directions for observational research. Am J Ophthalmol. 2010;150:569–574. doi: 10.1016/j.ajo.2010.05.005. [DOI] [PubMed] [Google Scholar]
  • 6.Stryker JE, Beck AD, Primo SA, et al. An exploratory study of factors influencing glaucoma treatment adherence. J Glaucoma. 2010;19:66–72. doi: 10.1097/IJG.0b013e31819c4679. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Sleath B, Ballinger R, Covert D, et al. Self-report prevalence and factors associated with nonadherence with glaucoma medications in veteran outpatients. Am J Geriatr Pharmacother. 2009;7:67–73. doi: 10.1016/j.amjopharm.2009.04.001. [DOI] [PubMed] [Google Scholar]
  • 8.Sleath B, Blalock SJ, Robin A, et al. Development of an instrument to measure glaucoma medication self-efficacy and outcome expectations. Eye (Lond) 2010;24:624–631. doi: 10.1038/eye.2009.174. [DOI] [PubMed] [Google Scholar]
  • 9.Sleath B, Robin AL, Covert D, et al. Patient-reported behavior and problems in using glaucoma medications. Ophthalmology. 2006;113:421–426. doi: 10.1016/j.ophtha.2005.10.034. [DOI] [PubMed] [Google Scholar]
  • 10.Muir KW, Santiago-Turla C, Stinnett SS, et al. Health literacy and adherence to glaucoma therapy. Am J Ophthalmol. 2006;142:223–226. doi: 10.1016/j.ajo.2006.03.018. [DOI] [PubMed] [Google Scholar]
  • 11.Robin AL, Novack GD, Covert DW, et al. Adherence in glaucoma: objective measurements of once-daily and adjunctive medication use. Am J Ophthalmol. 2007;144:533–540. doi: 10.1016/j.ajo.2007.06.012. [DOI] [PubMed] [Google Scholar]
  • 12.Robin AL, Covert D. Does adjunctive glaucoma therapy affect adherence to the initial primary therapy? Ophthalmology. 2005;112:863–868. doi: 10.1016/j.ophtha.2004.12.026. [DOI] [PubMed] [Google Scholar]
  • 13.Tsai JC, McClure CA, Ramos SE, et al. Compliance barriers in glaucoma: a systematic classification. J Glaucoma. 2003;12:393–398. doi: 10.1097/00061198-200310000-00001. [DOI] [PubMed] [Google Scholar]
  • 14.Taylor SA, Galbraith SM, Mills RP. Causes of non-compliance with drug regimens in glaucoma patients: a qualitative study. J Ocul Pharmacol Ther. 2002;18:401–409. doi: 10.1089/10807680260362687. [DOI] [PubMed] [Google Scholar]
  • 15.Meichenbaum D, Turk D. Facilitating Treatment Adherence: A Practitioner’s Guidebook. New York: Plenum; 1987. pp. 1–55. [Google Scholar]
  • 16.Roter DL, Hall JA, Merisca R, et al. Effectiveness of interventions to improve patient compliance: a meta-analysis. Med Care. 1998;36:1138–1161. doi: 10.1097/00005650-199808000-00004. [DOI] [PubMed] [Google Scholar]
  • 17.DiMatteo MR. Variations in patients’ adherence to medical recommendations: a quantitative review of 50 years of research. Med Care. 2004;42:200–209. doi: 10.1097/01.mlr.0000114908.90348.f9. [DOI] [PubMed] [Google Scholar]
  • 18.Olthoff CM, Schouten JS, van de Borne BW, Webers CA. Noncompliance with ocular hypotensive treatment in patients with glaucoma or ocular hypertension: an evidence-based review. Ophthalmology. 2005;112:953–961. doi: 10.1016/j.ophtha.2004.12.035. [DOI] [PubMed] [Google Scholar]
  • 19.Konstas AG, Maskaleris G, Gratsonidis S, Sardelli C. Compliance and viewpoint of glaucoma patients in Greece. Eye (Lond) 2000;14:752–756. doi: 10.1038/eye.2000.197. [DOI] [PubMed] [Google Scholar]
  • 20.Chen TC, Chao CW, Sorkin JA. Topiramate induced myopic shift and angle closure glaucoma [letter] Br J Ophthalmol. 2003;87:648–649. doi: 10.1136/bjo.87.5.648. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Friedman DS, Okeke CO, Jampel HD, et al. Risk factors for poor adherence to eyedrops in electronically monitored patients with glaucoma. Ophthalmology. 2009;116:1097–1105. doi: 10.1016/j.ophtha.2009.01.021. [DOI] [PubMed] [Google Scholar]
  • 22.Rossi GC, Pasinetti GM, Scudeller L, et al. Do adherence rates and glaucomatous visual field progression correlate? Eur J Ophthalmol. doi: 10.5301/EJO.2010.6112. In press. [DOI] [PubMed] [Google Scholar]
  • 23.Stone JL, Robin AL, Novack GD, et al. An objective evaluation of eyedrop instillation in subjects with glaucoma. Arch Ophthalmol. 2009;127:732–736. doi: 10.1001/archophthalmol.2009.96. [DOI] [PubMed] [Google Scholar]
  • 24.Kass MA, Gordon M, Morley RE, Jr, et al. Compliance with topical timolol treatment. Am J Ophthalmol. 1987;103:188–193. doi: 10.1016/s0002-9394(14)74225-4. [DOI] [PubMed] [Google Scholar]
  • 25.Sleath B, Blalock SJ, Stone JL, et al. Validation of a Short Version of the Glaucoma Medication Self-Efficacy Questionnaire. Br J Ophthalmol. 2011 doi: 10.1136/bjo.2010.199851. In Press. [DOI] [PubMed] [Google Scholar]
  • 26.Hodpp E, Parrish RK, Anderson DR. Clinical Decisions in Glaucoma. St Louis, MO: Mosby; 1993. pp. 53–59. [Google Scholar]
  • 27.Martin BC, Wiley-Exley EK, Richards S, et al. Contrasting measures of adherence in the presence of simple drug use, medication switching, and therapeutic duplication. Ann Pharmacother. 2009;41:36–44. doi: 10.1345/aph.1K671. [DOI] [PubMed] [Google Scholar]
  • 28.Patel SC, Spaeth GL. Compliance in patients prescribed eye drops for glaucoma. Opthalmic Surg. 1995;26:233–236. [PubMed] [Google Scholar]

RESOURCES