Skip to main content
The Texas Heart Institute Journal logoLink to The Texas Heart Institute Journal
. 1987 Jun;14(2):133–138.

The Use of Cardio-Green for Intraoperative Visualization of the Coronary Circulation: Evaluation of Myocardial Toxicity

Gerald C Taichman 1, Paul J Hendry 1, Wilbert J Keon 1
PMCID: PMC324712  PMID: 15229732

Abstract

Direct visualization of the extent and adequacy of the coronary blood flow distribution can be performed intraoperatively with an intracoronary injection of indocyanine green dye (Cardio-Green). Because Cardio-Green is potentially toxic to the myocardium, we studied its effects on the mechanical performance of cardiac muscle, using human right atrial trabeculae contracting in vitro. In the first series of experiments, muscles were exposed to 25 mg/ml of Cardio-Green (a concentration 100 times greater than what would be used clinically); no significant alteration in cardiac mechanics was found when evaluated by the force-frequency relationship. To establish the concentration at which Cardio-Green would be toxic, an accumulated dose-response relationship was determined. When a polynomial regression analysis was done, the results best fit a parabolic curve: At high doses, Cardio-Green was found to be negatively inotropic. The estimated concentration that would evoke a 50% decrease in developed force was 41.96 mg/ml. The results show that intracoronary injection of Cardio-Green at clinical doses up to 0.3 mg/ml does not affect myocardial muscle performance. Safe intraoperative use depends on appropriate low doses. (Texas Heart Institute Journal 1987; 14:133-138)

Keywords: Indocyanine green

Keywords: coronary circulation

Keywords: myocardial contraction

Keywords: aortocoronary bypass

Full text

PDF
133

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Anderson P. A., Manring A., Johnson E. A. Force-frequency relationship. A basis for a new index of cardiac contractility? Circ Res. 1973 Dec;33(6):665–671. doi: 10.1161/01.res.33.6.665. [DOI] [PubMed] [Google Scholar]
  2. BLINKS J. R., KOCH-WESER J. Analysis of the effects of changes in rate and rhythm upon myocardial contractility. J Pharmacol Exp Ther. 1961 Dec;134:373–389. [PubMed] [Google Scholar]
  3. Cohen M. V. The effects of intracoronary Renografin injection on coronary flow and distribution in dogs following coronary occlusion. Basic Res Cardiol. 1983 Jul-Aug;78(4):364–372. doi: 10.1007/BF02070161. [DOI] [PubMed] [Google Scholar]
  4. Keon W. J., Akyurekli Y., Bedard P., Brais M. P., Goldstein W., Beanlands D. S. Coronary endarterectomy: an adjunct to coronary artery bypass grafting. Surgery. 1979 Dec;86(6):859–867. [PubMed] [Google Scholar]
  5. Keon W. J. Manual coronary endarterectomy and revascularization: improving techniques and results. Ann Thorac Surg. 1981 Nov;32(5):427–428. doi: 10.1016/s0003-4975(10)61773-0. [DOI] [PubMed] [Google Scholar]
  6. Keon W. J., Taichman G. C., Mainwood G. W. Human atrial trabeculae: an experimental preparation for studying myocardial response to perioperative manipulations. Can J Surg. 1984 Jul;27(4):372-4, 377. [PubMed] [Google Scholar]

Articles from Texas Heart Institute Journal are provided here courtesy of Texas Heart Institute

RESOURCES