Abstract
When corrective surgery for tetralogy of Fallot was accomplished through the use of a transannular GORE-TEX® patch with a pericardial unicusp, the right-ventricular end-diastolic volumes of all patients studied within a year of the surgery were within the normal ranges because of decreased pulmonary valve regurgitation. The right-ventricular ejection fraction was also only slightly depressed, indicating preservation of right-ventricular function. All patients were noted to maintain normal stroke volumes and normal systolic indices.
In contrast, the patients who had transannular patches placed without unicusps showed significantly elevated right-ventricular end-diastolic volumes and lower right-ventricular ejection fractions. These resulted from markedly dilated right-ventricular outflow regions in conjunction with enlarged right-ventricular chambers, which manifested as large dyskinetic areas in the anterior right-ventricular walls. (Texas Heart Institute Journal 1987; 14:300-306)
Keywords: Teratology of Fallot
Keywords: heart surgery, corrective
Keywords: heart defects, congenital
Keywords: GORE-TEX® patch, transannular
Keywords: pulmonary valve stenosis
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ciaravella J. M., Jr, McGoon D. C., Danielson G. K., Wallace R. B., Mair D. D., Ilstrup D. M. Experience with the extracardiac conduit. J Thorac Cardiovasc Surg. 1979 Dec;78(6):920–930. [PubMed] [Google Scholar]
- Graham T. P., Jr, Cordell D., Atwood G. F., Boucek R. J., Jr, Boerth R. C., Bender H. W., Nelson J. H., Vaughn W. K. Right ventricular volume characteristics before and after palliative and reparative operation in tetralogy of Fallot. Circulation. 1976 Sep;54(3):417–423. doi: 10.1161/01.cir.54.3.417. [DOI] [PubMed] [Google Scholar]
- Graham T. P., Jr, Jarmakani J. M., Atwood G. F., Canent R. V., Jr Right ventricular volume determinations in children. Normal values and observations with volume or pressure overload. Circulation. 1973 Jan;47(1):144–153. doi: 10.1161/01.cir.47.1.144. [DOI] [PubMed] [Google Scholar]
- Laks H., Marin-Garcia J., Willman V. L. In situ placement of a valved conduit at the pulmonary annulus. J Thorac Cardiovasc Surg. 1977 Oct;74(4):640–644. [PubMed] [Google Scholar]
- Norwood W. I., Freed M. D., Rocchini A. P., Bernhard W. F., Castaneda A. R. Experience with valved conduits for repair of congenital cardiac lesions. Ann Thorac Surg. 1977 Sep;24(3):223–232. doi: 10.1016/s0003-4975(10)63747-2. [DOI] [PubMed] [Google Scholar]
- Oku H., Shirotani H., Yokoyama T., Yokota Y., Kawai J., Makino S., Noguchi K., Setsuie N., Nishioka T., Okamoto F. Right ventricular outflow tract prosthesis in total correction of tetralogy of Fallot. Circulation. 1980 Sep;62(3):604–609. doi: 10.1161/01.cir.62.3.604. [DOI] [PubMed] [Google Scholar]
- Rocchini A. P., Rosenthal A., Freed M., Castaneda A. R., Nadas A. S. Chronic congestive heart failure after repair of tetralogy of Fallot. Circulation. 1977 Aug;56(2):305–310. doi: 10.1161/01.cir.56.2.305. [DOI] [PubMed] [Google Scholar]