A Comparison of Flat-Sheet and Hollow-Fiber Membrane Oxygenators

The Shiley M-2000 vs. the Bentley BOS-CM 40

Mattias EM Bergdahl 1, Leif AL Bergdahl 1
PMCID: PMC324839  PMID: 15227233

Abstract

To compare new flat-sheet and hollow-fiber membrane oxygenators for use in cardiopulmonary bypass, we randomly divided 40 coronary artery surgery patients into 2 groups of 20 patients each. The Shiley M-2000 flat-sheet membrane oxygenator was used in 1 group, and the Bentley BOS-CM40 hollow-fiber membrane oxygenator was used in the other group. Both oxygenators allowed for adequate transfer of oxygen and carbon dioxide. At the end of perfusion, the platelet counts were significantly lower and the arterial pH significantly higher in the Shiley group than in the Bentley group. The other hematologic parameters, as well as postoperative blood losses, were similar in the 2 groups, but were also similar to those reported earlier with respect to bubble oxygenators. On the basis of these results, we conclude that, for routine short-term perfusion, these new membrane oxygenator models, while marginally different from one another, offer no real advantage over bubble models. (Texas Heart Institute Journal 1989;16:27-31)

Keywords: Oxygenators

Keywords: oxygenators, membrane

Keywords: extracorporeal circulation

Keywords: cardiopulmonary bypass

Keywords: open heart surgery

Keywords: blood gas exchange

Full text

PDF
27

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ANDERSEN M. N., HAMBRAEUS G. Physiologic and biochemical responses to prolonged extracorporeal circulation: experimental studies during four-hour perfusion. Ann Surg. 1961 Apr;153:592–598. doi: 10.1097/00000658-196104000-00029. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Bergdahl L., Björk V. O. The effect of a nylon mesh blood filter in the arterial line during extracorporeal circulation. Scand J Thorac Cardiovasc Surg. 1980;14(3):263–266. doi: 10.3109/14017438009101009. [DOI] [PubMed] [Google Scholar]
  3. Björk V. O., Bergdahl L., Wussow C. Gas flow in relation to blood flow in oxygenators. An evaluation of the new Shiley bubble oxygenator. Scand J Thorac Cardiovasc Surg. 1977;11(2):81–84. [PubMed] [Google Scholar]
  4. Burrows F. A., Steele R. W., Marmer D. J., Van Devanter S. H., Westerman G. R. Influence of operations with cardiopulmonary bypass on polymorphonuclear leukocyte function in infants. J Thorac Cardiovasc Surg. 1987 Feb;93(2):253–260. [PubMed] [Google Scholar]
  5. Clark R. E., Beauchamp R. A., Magrath R. A., Brooks J. D., Ferguson T. B., Weldon C. S. Comparison of bubble and membrane oxygenators in short and long perfusions. J Thorac Cardiovasc Surg. 1979 Nov;78(5):655–666. [PubMed] [Google Scholar]
  6. Edmunds L. H., Jr, Ellison N., Colman R. W., Niewiarowski S., Rao A. K., Addonizio V. P., Jr, Stephenson L. W., Edie R. N. Platelet function during cardiac operation: comparison of membrane and bubble oxygenators. J Thorac Cardiovasc Surg. 1982 Jun;83(6):805–812. [PubMed] [Google Scholar]
  7. Ennema J. J., Karliczek G. F., Gerding A., Tigchelaar I., Dijck L., Harder M. P., van der Heide J. N., Wildevuur C. R. Hematological effects of a new hollow fiber membrane oxygenator: a clinical study. Thorac Cardiovasc Surg. 1984 Apr;32(2):96–99. doi: 10.1055/s-2007-1023357. [DOI] [PubMed] [Google Scholar]
  8. Peirce E. C., 2nd Editorial: Is the blood-gas interface of clinical importance? Ann Thorac Surg. 1974 May;17(5):526–529. doi: 10.1016/s0003-4975(10)65690-1. [DOI] [PubMed] [Google Scholar]
  9. Peterson K. A., Dewanjee M. K., Kaye M. P. Fate of indium 111-labeled platelets during cardiopulmonary bypass performed with membrane and bubble oxygenators. J Thorac Cardiovasc Surg. 1982 Jul;84(1):39–43. [PubMed] [Google Scholar]
  10. Quiroga M. M., Miyagishima R., Haendschen L. C., Glovsky M., Martin B. A., Hogg J. C. The effect of body temperature on leukocyte kinetics during cardiopulmonary bypass. J Thorac Cardiovasc Surg. 1985 Jul;90(1):91–96. [PubMed] [Google Scholar]
  11. Servas F. M., Diettrich L. J., Jones K., Whittaker D., Curtis R. High efficiency membrane oxygenator. Trans Am Soc Artif Intern Organs. 1983;29:231–236. [PubMed] [Google Scholar]
  12. Siderys H., Herod G. T., Halbrook H., Pittman J. N., Rubush J. L., Kasebaker V., Berry G. R., Jr A comparison of membrane and bubble oxygenation as used in cardiopulmonary bypass in patients. The importance of pericardial blood as a source of hemolysis. J Thorac Cardiovasc Surg. 1975 May;69(5):708–712. [PubMed] [Google Scholar]
  13. Trumbull H. R., Howe J., Mottl K., Nicoloff D. M. A comparison of the effects of membrane and bubble oxygenators on platelet counts and platelet size in elective cardiac operations. Ann Thorac Surg. 1980 Jul;30(1):52–57. doi: 10.1016/s0003-4975(10)61202-7. [DOI] [PubMed] [Google Scholar]
  14. de Leval M. R., Hill J. D., Mielke C. H., Jr, Macur F., Gerbode F. Blood platelets and extracorporeal circulation; kinetic studies on dogs on cardiopulmonary bypass. J Thorac Cardiovasc Surg. 1975 Jan;69(1):144–151. [PubMed] [Google Scholar]
  15. van Oeveren W., Dankert J., Wildevuur C. R. Bubble oxygenation and cardiotomy suction impair the host defense during cardiopulmonary bypass: a study in dogs. Ann Thorac Surg. 1987 Nov;44(5):523–528. doi: 10.1016/s0003-4975(10)62114-5. [DOI] [PubMed] [Google Scholar]

Articles from Texas Heart Institute Journal are provided here courtesy of Texas Heart Institute

RESOURCES