Abstract
The automatic implantable cardioverter-defibrillator is composed of shocking electrodes (patches or coils), sensing electrodes, and a generator implanted in the abdominal wall. A number of complications with defibrillators have been reported, including migration of the various components. We describe a patient in whom one of the patches, originally sutured extrapericardially, migrated in the right hemithorax and eroded into the ipsilateral lung. The resultant massive hemothorax necessitated urgent thoracotomy, patch removal, and hematoma evacuation. A hybrid implantable cardioverter-defibrillator system was created as a replacement to minimize surgery while protecting the patient from sudden death.
Full text
PDF



Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bardy G. H., Hofer B., Johnson G., Kudenchuk P. J., Poole J. E., Dolack G. L., Gleva M., Mitchell R., Kelso D. Implantable transvenous cardioverter-defibrillators. Circulation. 1993 Apr;87(4):1152–1168. doi: 10.1161/01.cir.87.4.1152. [DOI] [PubMed] [Google Scholar]
- Daly B. D., Cascade P. N., Hummel J. D., Kalbfleisch S., Strickberger S. A., Langberg J., Morady F. Transvenous and subcutaneous implantable cardioverter defibrillators: radiographic assessment. Radiology. 1994 Apr;191(1):273–278. doi: 10.1148/radiology.191.1.8134587. [DOI] [PubMed] [Google Scholar]
- Gupta S., Prevel C. D., Shaheen K., Wilkens E., Smith D. J., Jr, Kirsh M. M., Bolling S. F., Rees R. S. Wound complications and treatment of the infected implantable cardioverter defibrillator generator. J Card Surg. 1993 Nov;8(6):671–677. doi: 10.1111/j.1540-8191.1993.tb00428.x. [DOI] [PubMed] [Google Scholar]
- Kassanoff A. H., Levin C. B., Wyndham C. R., Mills L. J. Implantable cardioverter defibrillator infection causing constrictive pericarditis. Chest. 1992 Sep;102(3):960–963. doi: 10.1378/chest.102.3.960. [DOI] [PubMed] [Google Scholar]
- Kelly P. A., Mann D. E., Damle R. S., Reiter M. J. Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator. J Am Coll Cardiol. 1994 Jun;23(7):1531–1534. doi: 10.1016/0735-1097(94)90651-3. [DOI] [PubMed] [Google Scholar]
- Manolis A. S., Rastegar H., Estes N. A., 3rd Automatic implantable cardioverter defibrillator. Current status. JAMA. 1989 Sep 8;262(10):1362–1368. [PubMed] [Google Scholar]
- Marchlinski F. E., Flores B. T., Buxton A. E., Hargrove W. C., 3rd, Addonizio V. P., Stephenson L. W., Harken A. H., Doherty J. U., Grogan E. W., Jr, Josephson M. E. The automatic implantable cardioverter-defibrillator: efficacy, complications, and device failures. Ann Intern Med. 1986 Apr;104(4):481–488. doi: 10.7326/0003-4819-104-4-481. [DOI] [PubMed] [Google Scholar]
- McCowan R., Maloney J., Wilkoff B., Simmons T., Khoury D., McAlister H., Morant V., Castle L. Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardial and submuscular patch system. J Am Coll Cardiol. 1991 Feb;17(2):415–421. doi: 10.1016/s0735-1097(10)80108-1. [DOI] [PubMed] [Google Scholar]
- Mirowski M., Reid P. R., Mower M. M., Watkins L., Gott V. L., Schauble J. F., Langer A., Heilman M. S., Kolenik S. A., Fischell R. E. Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med. 1980 Aug 7;303(6):322–324. doi: 10.1056/NEJM198008073030607. [DOI] [PubMed] [Google Scholar]
- Verheyden C. N., Price L., Lynch D. J., Knight W. L. Implantable cardioverter defibrillator patch erosion presenting as hemoptysis. J Cardiovasc Electrophysiol. 1994 Nov;5(11):961–963. doi: 10.1111/j.1540-8167.1994.tb01135.x. [DOI] [PubMed] [Google Scholar]