Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2012 Dec 15.
Published in final edited form as: Anal Chem. 2011 Nov 15;83(24):9352–9360. doi: 10.1021/ac201948f

Measurement of Absolute Concentrations of Individual Compounds in Metabolite Mixtures by Gradient-Selective Time-Zero 1H-13C HSQC (gsHSQC0) with Two Concentration References and Fast Maximum Likelihood Reconstruction Analysis

Kaifeng Hu 1,†,*, James J Ellinger 1,, Roger A Chylla 1,, John L Markley 1,†,
PMCID: PMC3253702  NIHMSID: NIHMS338079  PMID: 22029275

Abstract

Time-zero 2D 13C HSQC (HSQC0) spectroscopy offers advantages over traditional 2D NMR for quantitative analysis of solutions containing a mixture of compounds because the signal intensities are directly proportional to the concentrations of the constituents. The HSQC0 spectrum is derived from a series of spectra collected with increasing repetition times within the basic HSQC block by extrapolating the repetition time to zero. Here we present an alternative approach to data collection, gradient-selective time-zero 1H-13C HSQC0 in combination with fast maximum likelihood reconstruction (FMLR) data analysis and the use of two concentration references for absolute concentration determination. Gradient-selective data acquisition results in cleaner spectra, and NMR data can be acquired in both constant-time and non-constant time mode. Semi-automatic data analysis is supported by the FMLR approach, which is used to deconvolute the spectra and extract peak volumes. The peak volumes obtained from this analysis are converted to absolute concentrations by reference to the peak volumes of two internal reference compounds of known concentration: DSS (4,4-dimethyl-4-silapentane-1-sulfonic acid) at the low concentration limit (which also serves as chemical shift reference) and MES (2-(N-morpholino)ethanesulfonic acid) at the high concentration limit. The linear relationship between peak volumes and concentration is better defined with two references than with one, and the measured absolute concentrations of individual compounds in the mixture are more accurate. We compare results from semi-automated gsHSQC0 with those obtained by the original manual phase-cycled HSQC0 approach. The new approach is suitable for automatic metabolite profiling by simultaneous quantification of multiple metabolites in a complex mixture.

INTRODUCTION

The primary objective of metabolomics studies is to identify individual chemical components in mixtures and to relate their concentrations to the precise biological state of the system, such as stress, age, and disease.1 Many methods have been developed to accurately and efficiently identify and profile changes in distinct sets of biomarkers. 24 Quantitative 1D proton NMR (qHNMR) is used as a routine analytical tool for concentration determination because of its universality, sensitivity, precision, and nondestructive nature.5 The integrated intensities of resolved proton resonances in qHNMR spectra are directly proportional to the number of proton spins in the mixture.5, 6 However, this approach has shortcomings for signals that are overlapped. 2D 1H-13C HSQC spectra contain a much higher proportion of resolved peaks, but the intensities of cross peaks in conventional 2D NMR experiments are not simply proportional to the concentrations of individual metabolites because of resonance-specific signal attenuation during the coherence transfer periods.7 Therefore, conventional 2D NMR experiments usually are not suitable for direct quantitative purpose. Rai et al. presented a method in which signal attenuation factors were calculated for different metabolites and used to evaluate their concentrations from adjusted cross-peak intensities.7 An alternative technique is to determine scaling factors from 2D spectra of standards at known concentration collected under the same conditions used for the solution to be analyzed.8 We recently reported an approach to acquiring a 2D spectrum (HSQC0 spectrum) with peak intensities directly proportional to relative concentrations of compounds in mixtures.9 The peak intensities in the HSQC0 spectrum are derived by extrapolating to time zero the peak heights derived from spectra (HSQCi) collected at the ends of the basic HSQC block repeated once (i=1), twice (i=2), and, optionally, three (i=3) times.9 Despite its superior sensitivity, the existence of strong spectral noise, especially t1 noise from metabolites with relatively high concentrations limit the applicability of the original phase-cycled HSQC0 approach. 10 The t1 noise ridge can obscure cross peaks from metabolites with relatively lower concentrations and thus affect the accuracy of measured peak volumes, and hence reduce the precision and accuracy of concentration estimates. We present here an improved protocol that combines new approaches to data collection and analysis. (1) Phase-cycled spectra are replaced by gradient-selective HSQCi (gsHSQCi) spectra, which results in much cleaner spectra (Figure S1). (2) Semi-automated data analysis is carried out by the fast maximum likelihood reconstruction (FMLR) approach 11 as implemented in the Newton software package. 12 (3) Two internal reference compounds that span the concentration range of the compounds being analyzed are added to the mixture to be analyzed, which improves the precision and accuracy of compound quantification. We anticipate that this new protocol for 2D 1H-13C spectroscopy will prove valuable for automatic metabolite profiling by simultaneous quantification of multiple metabolites in a complex mixture.

METHODS

Pulse Sequence Design

In implementing gsHSQC0 spectroscopy to suppress t1 artifacts, different selective gradient pairs must be used in each HSQCi block to avoid gradient refocusing among the HSQCi units,. The selective gradients must follow: ΔG12 = ΔG34 = ΔG56 = 0; ΣG12 ≠ ΣG34 ≠ ΣG56; and ΣG12 ± ΣG34 ≠ ΣG56 (See the theoretical description of gsHSQCi in the Supporting Information). Differences in the signal attenuation factors among the HSQC blocks due to the application of different selective gradient pairs are small and can be neglected. We have found that equivalent peak volumes are obtained even though HSQCi data are acquired with the different sets of selective gradients as illustrated in Figure 1. The loss of sensitivity in gsHSQCi due to gradient selection is partially compensated by running gsHSQCi as the non-constant time version (Figure 1C).

Figure 1.

Figure 1

(A) Basic building block of pulse sequence of the gradient selective constant time 2D HSQC for quantification. Narrow and wide black bars indicate 90° and 180° pulses, respectively. The delays are τ = 3.45 ms; T = 10.4 ms. The phase cycling is as follows: φ1 = x, −x; φ2 = 2[x], 2[−x]; φrec = x, −x, −x, x. All other radio-frequency pulses are applied with phase x except as indicated. Quadrature detection in the 13C (t1) dimension is achieved using echo-antiecho through flipping the polarity of gradient g1 (filled and dashed sine bell). The 180° pulse marked with asterisk is inserted to refocus chemical shift of proton during the gradient delays for g13 and g14 to achieve better t1 noise suppression. All pulsed field gradients are applied along the z-axis with a duration of 1 ms followed by gradient recovery period of 200 μs. The strength of the gradients (percentage of highest gradient current, 10 A) are: g13: 37.1 G/cm (70%); g14: 45.05 G/cm (85%); g15: 7.95 G/cm (15%), and g16: 47.7 G/cm (90%), and the selective gradient pairs are g1: 42.4 G/cm (80%) and g2: 10.653 G/cm (20.1%). (B) Diagram showing the relevant coherence pathways for echo (indicated by the solid arrow lines in upper scheme) and antiecho (indicated by the dashed arrow lines in the lower scheme). In both situations, both the coherence pathways shown in red and green are selected, but only the I density operator terms (green coherence pathway) are detected by the spectrometer. (C) Basic building block of the gradient-selective non-constant time 2D HSQC pulse sequence used for quantification. The short delay δ1 = 1.21 ms is just to accommodate the coherence selective pulsed field gradients g1, including the gradient recovery period of 200 μs. (D) Full gradient-selective 2D HSQCi (i = 1, 2, 3) pulse sequence. HSQC units HSQC2 and HSQC3 with corresponding selective gradient pairs (g3/g4 and g5/g6, respectively) are inserted in front of HSQC1, in which chemical shift of 13C (t1) is allowed to evolve. Within HSQC2 and HSQC3 units, the constant time period T is replaced by the invariant constant time T without encoding chemical shift evolution. The additional phase cyclings for HSQC2 are φ3 = 4[x], 4[−x], φrec = x, −x, −x, x, −x, x, x, −x and for HSQC3 are φ4 = 8[x], 8[−x], φrec = x, −x, −x, x, −x, x, x, −x, −x, x, x, −x, x, −x, −x, x. To avoid quadrature imaginary peaks due to gradient echoes between HSQC blocks, different selective gradient pairs must be used in each HSQC block. Differences in signal attenuation due to different selective gradient pairs applied among the HSQC blocks can be ignored (Figure 3 (1) and (2), overlapped). It is demonstrated by using two different sets of selective gradients as: Set 1) g1: 80%; g2: 20.1%; g3: 70%; g4: 17.59%, g5: 60%; g6: 15.075% of the maximum of 53 G/cm. (Data Table S1 and S5). Set 2) g1: 80%; g2: 20.1%; g3: 60%; g4: 15.075%, g5: 40%; g6: 10.05% of the maximum of 53 G/cm. (Data Table S2 and S6). (E) Diagram showing the relevant coherence pathways of (D), with the echo coherence pathway indicated by the solid arrow lines (upper scheme) and the antiecho indicated by the dashed arrow lines (lower scheme). Quadrature detection is achieved in the HSQC1 unit. In HSQC2 and HSQC3, spin “echo” gradient selection (coherence order in black and corresponding solid arrow lines in both upper and lower schemes) is achieved through selective gradient pairs g3/g4 and g5/g6, respectively.

In quantitative, gradient-selective 2D 1H-13C HSQC (Figure 1), immediately after the first 90° excitation pulse (with phase x), the density operator I−y is generated, which can be decomposed as a linear combination of ½ I and ½ I+. The density operator right before detection (point f) has the same format as the density operator generated immediately after the first 90° excitation pulse, which can be decomposed as linear combination of ¼ I and ¼ I+, of which only the ¼ I term is detected by the spectrometer. Compared to the density operator immediately after the 90° excitation pulse (½ I and ½ I+), the uniform scaling factor of ½ (from ½ I to ¼ I and from ½ I+ to ¼ I+) is due to the gradient selection during the coherence pathway. A detailed description of the relevant coherence pathways is given in the Supporting Information. Figure 1B shows the scheme of the relevant coherence pathway for echo (indicated by the solid arrow lines in upper scheme) and antiecho (indicated by the dashed arrow lines in the lower scheme), respectively. In each situation, the coherence pathways in red and green are both selected, but only the ¼ I density operator term (green coherence pathway) will be detected by the spectrometer. In both approaches, an amplitude attenuation factor fA,n specific for each functional group arises during the coherence pathway due to relaxation, imperfect pulses, mismatch of the INEPT transfer delay with J-coupling, etc. 9 Thus, the amplitudes of the detected signals for phase-cycled approach are given by Eq 1, whereas those for the gradient-selective approach are given by Eq 2:

A1,n(Iy)=A0,n(Iy)·fA,n (1)
A1,n(I)=2A0,n(I)·(fA,n·12) (2)

in which A1,n(I) is the integrated peak intensity (signal amplitude) of peak n; A0,n is the virtual integrated signal intensity (signal amplitude) of peak n immediately after the first 90° excitation pulse; and fA,n is the amplitude attenuation factor specific for peak n. In the gradient-selective approach (Eq 2) the scaling factor of ½ arises from to the gradient selection, and the factor of 2 in front of A0,n accounts for signal enhancement resulting from the linear recombination of the time domain NMR data recorded in the echo-antiecho mode. The fA,n factor accounts for signal losses during the coherence transfer periods from point a (Figure 1A, immediately after the first 1H excitation pulse) to point f (Figure 1A, immediately before acquisition). This attenuation factor fA,n is specific to a particular cross peak (peak n) because of different chemical environments, dynamics, relaxation properties, and J-couplings. Therefore, the peak intensity A1,n(I) in 2D 13C gsHSQC is not directly proportional to the number of spins giving rise to the signals. However, as in phase-cycled HSQC, 9 the scaling factor fA,n can be determined simply by inserting the pulse sequence components included in the brackets (Figure 1D) in front of the HSQC1 unit. Three 2D HSQCi (i = 1, 2, 3) spectra are acquired, in which the subscript i indicates the number of times the basic building block is repeated. Note that in HSQC2 and HSQC3, additional phase cycling is applied on φ3 and φ4 and on the receiver phase φrec. Figure 1E shows the relevant coherence pathway for the full pulse sequence of gradient-selective 2D HSQCi (i=1, 2, 3). Echo (indicated by the solid arrow lines in upper scheme) and antiecho (indicated by the dashed arrow lines in the lower scheme) quadrature detection is achieved in the HSQC1 unit. For both situations, both coherence pathways in red and green are selected, but only the 1/16 I density operator term (green coherence pathway) is detected. In HSQC2 and HSQC3 units (Figure 1E), spin “echo” gradient selection (coherence order in black and corresponding solid arrow lines in both upper and lower scheme) is achieved through selective gradient pairs, g3/g4 and g5/g6, respectively. The density operators detected in 2D gsHSQCi (i=1, 2, 3) all have the same format, which can be decomposed as linear combination of ¼ I and ¼ I+; 1/8I and 1/8I+; 1/16I and 1/16I+, respectively (Figures 1D and 1E). The virtual peak intensity of peak n in gsHSQC0, A0,n, can be obtained through linear regression extrapolation of:

ln(Ai,n)=ln(2A0,n)+i×ln(fA,n·12) (3)

whereas the virtual peak intensity of peak n in phase-cycled HSQC0 is obtained through linear regression extrapolation of: 9

ln(Ai,n)=ln(A0,n)+i×ln(fA,n) (4)

Sample Preparation

Model mixture of metabolites: L-alanine, L-methionine, 3-hydroxybutyrate and D-glucose were purchased from Sigma-Aldrich. 2-(N-morpholino)ethanesulfonic acid (MES) was from Research Organics. DSS and 99.8% D2O were from Cambridge Isotope Laboratories. All dry reagents were stored under desiccation to ensure that they were free of moisture absorbed from the air. Alanine, methionine, 3-hydroxybutyrate, D-glucose and MES were weighed directly into a grade A 50 mL Kimax volumetric flask to give final concentrations of 12.35, 18.14, 26.78, 22.32 and 49.93 mM, respectively. A 35.57 mM DSS stock solution was prepared by weighting. Aliquots of the stock solution were added to volumetric flasks to give final concentration of 3.557 mM (1:10 dilution). Each reagent was prepared from weighing to at least 3 significant figures on an analytical balance of ±0.1 mg precision. Approximately 40 mL of D2O was slowly added to the sample while gently swirling; the observed pH was adjusted to 7.400 using deuterated base; and the final volume was adjusted to 50 mL. The solution rested at least 6 h to ensure anomeric equilibration of D-glucose. Prior to NMR data acquisition, 12 μL of 100 mM Fe(III)EDTA was added to 500 μL of the mixture as a relaxation agent; with this sample, the longest proton T1 was measured to be shorter than 0.433 s. Bovine liver extract: Bovine liver was purchased from a local organic grocer, frozen, and lyophilized until dry. After lyophilization, a morsel (420 mg) was macerated gently with a metal spatula in a mortar placed on dry ice. The tissue was transferred to a 50 mL conical tube on dry ice and homogenized with a rounded glass rod. Then, 16 mL hot (95° C), distilled, deionized water was added, and the sample was briefly agitated by vortex mixing. The sample was then placed in a 95° C water bath for 7.5 min. Samples were removed from the hot water bath, briefly agitated by vortex mixing, chilled on ice, and centrifuged at 8000 RPM for 5 min (4° C) to remove cellular debris. The resulting supernatant was filtered through a 3 kDa cut-off ultrafiltration membrane. The filtered liver extract was frozen, lyophilized, and resuspended in 1 mL 99.9% D2O. The final sample was prepared by mixing 786 μL of extract with 200 μL MES (249.65 mM stock solution) and 14 μl DSS (35.57 mM stock solution). The final concentrations of MES and DSS were 49.93 mM and 0.498 mM, respectively, which served as concentration references for quantification. Finally, the sample was titrated to a pH reading of 7.350 by adding a small amount of 1 M NaOD. 600 μL of the above sample was transferred to an NMR tube and used directly to collect HSQCi data, A relaxation enhancing agent, 14 μL of 100 mM Fe(III)EDTA, was added to a second 600 μL sample of the liver extract to shorten the inter-scan delay used in HSQCi data collection.

NMR Experiments

For the model mixture of metabolites, NMR data were collected on a 700 MHz Bruker Avance III spectrometer equipped with a QCI probe, with radio-frequency pulses applied on 1H and 13C at 4.8 ppm and 48 ppm, respectively. GARP 13C decoupling used a field strength of γB2 = 2.5 kHz. 2048 × 75 complex data points with spectral width of 16 ppm and 80 ppm, respectively, were collected along the 1H and 13C dimensions, with 16 scans per FID and an inter-scan delay of 2.5 s (longer than 5 times of the longest proton T1 value), resulting in a total acquisition time of 2 h for each HSQCi.

The constant-time delay T was set to 10.4 ms. Constant-time gsHSQCi data were collected with two different sets of selective gradients. (Set 1) g1: 42.4 G/cm (80%); g2: 10.653 G/cm (20.1%); g3: 37.1 G/cm (70%); g4: 9.3214 G/cm (17.5875%); g5: 31.8 G/cm (60%); and g6: 7.98975 G/cm (15.075%) (see Supporting Information, Tables S1 and S5). (Set 2) g1: 42.4 G/cm (80%); g2: 10.653 G/cm (20.1%); g3: 31.8 G/cm (60%); g4: 7.98975 G/cm (15.075%); g5: 21.2 G/cm (40%); and g6: 5.3265 G/cm (10.05%)(see data Table S2 and S6). For comparison, constant-time phase-cycled HSQCi (see Supporting Information, Tables S3 and S7) and non-constant time gsHSQCi (see Supporting Information, Tables S4 and S8) data were also collected.

For the bovine liver extract with and without added relaxation enhancing agent, constant-time gsHSQCi data were collected with gradient set 1 (above) on a 600 MHz Bruker Avance III spectrometer equipped with a QCI probe by setting an inter-scan delay of 2.0 s and 11.0 s, respectively. 2048 × 80 complex data points with spectral width of 16 ppm and 80 ppm, respectively, were collected along the 1H and 13C dimensions. For bovine liver extract without relaxation enhancing agent, 16 scans per FID are acquired resulting in a total acquisition time of 8 h for each HSQCi; for the sample with Fe(III)EDTA, 32 scans per FID were acquired resulting in a total acquisition time of 3 h for each HSQCi.

Peak Amplitude and Peak Intensity Measurements

Spectral deconvolution of data sets was performed using the method of fast maximum likelihood reconstruction (FMLR) 11 as implemented in the Newton software package (Newton-FMLR). 12 Newton-FMLR iteratively constructs a time-domain model with the fewest number of signals whose Fourier transformation matches the peaks visible in the spectrum. The HSQC1 data set was used as a reference data set for deconvolution. The signal model obtained from this data set was propagated to the HSQC2 and HSQC3 data sets, where the amplitudes of the signals were determined by linear least squares analysis. In cases where more than one peak (signal multiplicity) is associated with a given atom, a region of interest was constructed, and the sum of the amplitudes in the region was used to perform the extrapolation of the time zero amplitude. 12 For the model mixture of metabolites, the sum of the amplitudes of the reconstructed signals is analogous to integration of the spectral region (Supporting Information, Tables S5–S8). For comparison, the peak intensity was also obtained through manual integration (Supporting Information, Tables S1–S4) as described previously.9 For bovine liver extract samples, 47 regions of interest (ROI) (Figure 4) were chosen for quantification of 23 metabolites in the mixture. The signal amplitudes were obtained by fast maximum likelihood reconstruction (FMLR) analysis (Tables S9–S10 for bovine liver extract samples with and without relaxation enhancing agent).

Figure 4.

Figure 4

600 MHz 2D constant-time gradient-selective HSQC1 spectrum of bovine liver extract sample with relaxation enhancing agent, Fe(III)EDTA in D2O containing 0.498 mM DSS and 49.93 mM MES as concentration references. 47 labeled peaks were chosen for quantification of 23 metabolites in the mixture.

Absolute Concentrations of Individual Metabolites

The measured peak volumes were related to the absolute concentrations by using two compounds with known gravimetric concentrations (Cg) as concentration references: DSS (which also served as the chemical shift reference) at the low concentration limit and MES at the high concentration limit. With two concentration references, the linear relation between the concentration and the obtained peak volume is defined by: Cg = kA0 + b, in which k and b are calculated from the averaged normalized peak intensity or peak amplitude (A0) of DSS and MES and their corresponding gravimetric concentrations (Supporting Information, Tables S1A–S8A, for the model mixture of metabolites; Table S11, for the bovine liver extract samples, relevant information is highlighted in blue). The non-zero constant b may indicate a non-zero baseline offset (gray background). On the other hand, b can be set to 0 to force the concentration to be linearly proportional to the obtained peak intensities or peak amplitudes (A0). Once the values of k and b are obtained, the measured concentration of each metabolite is then calculated as Cm = kA0 + b from the measured normalized peak intensity or peak amplitude A0 of each individual cross peak. The accuracy and precision of the measured absolute concentration of each individual chemical in the metabolite mixture was analyzed (Supporting Information, Tables S1A–S8A).

RESULTS

Figure 2 shows the 2D gradient-selective constant-time HSQC1 spectrum of the model metabolite mixture containing DSS, alanine (A), methionine (M), 3-hydroxybutyrate sodium (HB), D-glucose (G) and MES in D2O, in which there is thermodynamic equilibrium between the α-D-glucose (αG) and β-D-glucose (βG) at 36%:64%. The peaks are labeled with the molecule identifier and the position of the functional group. The manually integrated peak intensities for these compounds are shown in the Supporting Information (Tables S1–S4), and the peak amplitudes extracted by Newton-FMLR from the HSQCi are shown in the Supporting Information (Tables S5–S8). The measured concentration of each metabolite calculated using the manually integrated peak intensity and peak amplitude A0 from Newton-FMLR are shown in the Supporting Information (Tables S1A–S4A and Tables S5A–S8A, respectively).

Figure 2.

Figure 2

700 MHz 2D gradient selective constant time HSQC1 spectrum of the model metabolite mixture of 12.35 mM alanine (A), 18.14 mM methionine (M), 26.78 mM 3-hydroxybutyrate sodium (HB), and 22.32 mM D-glucose (G) in D2O containing 3.557 mM DSS and 49.93 mM MES as concentration references. The glucose exists as a thermodynamic equilibrium between 36% α-D-glucose (αG) and 64% β-D-glucose (βG). The molecular structures and corresponding naming of these compounds are shown. The peaks are labeled with the molecular abbreviated name and the position of the functional group.

Equations 3 and 4 predict a difference of ln(2) between the intercepts in the linear regression of gsHSQCi and phase-cycled HSQCi data. Using both manual integrated peak volumes (Figure 3A) and peak amplitudes from semi-automated Newton-FMLR analysis (Figure 3B), this difference can be seen in the analyzed results for gsHSQCi (Figure 3: (1) and (2) solid lines with selective gradient sets 1 and 2, respectively.) and phase-cycled HSQCi (Figure 3: (3) States-TPPI_CT, dashed lines). The uniform scaling factor of ½ due to the gradient selection can lead to the quick signal attenuation in gsHSQCi as i increases. This can be partially alleviated by collecting gsHSQCi data in non-constant-time mode (Figure 1C), which yields a larger cross peak specific amplitude attenuation factor fA,n than in constant-time mode (Figure 3: (4), dotted lines).

Figure 3.

Figure 3

Extrapolation of methionine methyl (M:CH3) 1H-13C cross peak intensities from HSQCi data acquired at 700 MHz (1H) by (1) constant-time gradient-selective HSQCi (gsHSQCi) with selective gradient set 1 (EA_CT_grad_set1), (2) gsHSQCi with selective gradient set 2 (EA_CT_grad_set2), (3) constant-time phase-cycled HSQCi (States-TPPI_CT), and (4) non-constant-time gradient-selective HSQCi with selective gradient set 1 (EA_non-CT). Peak volumes were determined by (A) manual integration and (B) semi-automated Newton-FMLR analysis. Note line (1) is covered under that of (2).

Compared to the constant-time gsHSQCi (Figure 3: (1) and (2) solid lines), linear regression with the non-constant-time gsHSQCi (Eq. 3) gives a slightly shallower slope (Figure 3: (4) dotted lines) due to the slower signal attenuation as i increases. Note that although the cross peak specific amplitude attenuation factor fA,n is different for constant-time and non-constant-time gsHSQCi, linear regression with both constant-time and non-constant-time gsHSQCi results in the same A0,n value, that is, the same virtual gsHSQC0 (Figure 3: (1), (2), and (4) have the same intercepts).

The accuracy and precision of the obtained absolute concentration for individual chemicals in the model metabolite mixture are analyzed in Supporting Information (Tables S1A–S8A). Table 1 summarizes the average accuracy and precision of the measured concentration as well as the obtained percentage of α-D-glucose by different approaches: constant-time gsHSQC0 with two different sets of selective gradients, non-constant-time gsHSQC0, and phase-cycled HSQC0 as analyzed by manual integration (direct summation) of peak volumes and by semi-automated Newton-FMLR. The accuracy and precision of the results obtained by semi-automated Newton-FMLR are in agreement with concentrations obtained by manual integration (Table 1).

Table 1.

Accuracy and precision of the measured concentrations and obtained percentage of αD-glucose from peak volumes obtained by manual integration and semi-automated Newton-FMLR analysis from four extrapolated time-zero HSQC approaches.

Manual integration Constant-time gsHSQC0, set 1 Constant-time gsHSQC0, set 2 Non-constant-time gsHSQC0 Phase-cycled HSQC0
% α-D-Glucose 38.35% 38.47% 36.23% 36.75% 38.01% 38.20% 37.62% 37.88%
Average accuracy 5.50% 4.81% 1.97% 4.33% 5.40% 4.69% 2.81% 3.23%
Average precision 3.70% 3.68% 5.52% 5.40% 3.61% 3.56% 7.52% 7.39%
Newton-FMLR Constant-time gsHSQC0, set 1 Constant-time gsHSQC0, set 2 Non-constant- time gsHSQC0 Phase-cycled HSQC0
% α-D-Glucose 38.66% 38.27% 37.53% 38.27% 36.04% 37.00% 37.84% 38.32%
Average accuracy 4.89% 8.95% 3.70% 9.40% 4.50% 10.82% 3.20% 5.25%
Average precision 4.86% 4.64% 6.11% 5.72% 6.62% 6.03% 8.51% 8.11%

Values were calculated for k and b, by using the linear relation between the gravimetric concentration Cg and the normalized peak volume A0 (Cg = kA0 + b) and the known gravimetric concentrations of DSS and MES. The parameter b was set as 0 (white background) or was allowed to float to account for non-zero baseline offset (grey background).

Measured concentrations were then calculated from individual A0 values and the known k and b values by the equation, Cm = kA0 + b, in which b is 0 (white background) or non-zero intercept (grey background).

The average concentration was calculated as the average of Cm values for cross peaks belonging to the same individual chemical; Stdev was calculated as the standard deviation of Cm values for cross peaks belonging to the same individual chemical.

The percentage of α-D-glucose was calculated as: Ave. conc. of αG/ (Ave. conc. of αG + Ave. conc. of βG).

Accuracy was calculated as: (Ave. conc. Cm − Cg)/Cg, Precision was calculated as: Stdev/(Ave. conc. Cm). Finally, Ave. Accuracy was calculated as in(Accuracyi)2/n; Ave. Precision was calculated as in(Precisioni)2/n;

To further explore the performance of the approach, we applied the gsHSQC0 together with semi-automated fast maximum likelihood reconstruction (FMLR) data analysis to quantify individual metabolites in a bovine liver extract. Figure 4 shows the 2D gradient-selective constant-time HSQC1 spectrum of the bovine liver extract containing the relaxation enhancing agent, Fe(III)EDTA.

47 ROIs (Figure 4) were chosen for quantification of 23 metabolites in the mixture. Signal amplitudes obtained from Newton-FMLR analysis of constant-time gsHSQCi of bovine liver extract with and without Fe(III)EDTA are shown in Table S9 and S10, respectively. Using DSS and MES at respective gravimetric concentrations (Cg) of 0.498 mM and 49.930 mM as concentration references and the linear relation between the concentration and the normalized peak volume A0, Cg = kA0 + b, yielded values for k and b (Table S11). Measured concentrations of metabolites in the bovine liver extract with or without Fe(III)EDTA were then calculated from individual normalized peak volumes A0 using the known k and b values, Cm = kA0 + b (Table 2). The results obtained from the bovine liver extract sample with the relaxation enhancing agent are in agreement with those without the relaxation enhancing agent, but the latter required much longer acquisition times as described in NMR experiments. Moreover, without the relaxation agent, peaks in the spectra of the bovine liver extract sample from pantothenate methyl groups Ca and Cb and methionine Cγ were too weak to be detected and used for quantitative purpose. The relatively poor precision for pantothenate and taurine (Table 2, grey background) is probably due, respectively, to overlaps of signals from the pantothenate Ca and leucine Cδ2 methyl group and to the effect of the signal from the C1 group of MES (present at high concentration) on the relatively weak signal from the C1 of taurine.

Table 2.

Measured concentrations of metabolites in the bovine liver extract with or without Fe(III)EDTA using constant-time gsHSQCi

Compound: 2D NMR cross peak used in quantitation Liver_extract with Fe(III)EDTA Liver_extract without Fe(III)EDTA

Conc. Calcd. k,b (mM) Ave./Precision Conc. Calcd. k,0 (mM) Ave./Precision Conc. Calcd. k,b (mM) Ave./Precision Conc. Calcd. k,0 (mM) Ave./Precision
MES:C4-H4 47.341 49.930 47.344 49.929 48.923 49.930 48.923 49.930
MES:C2-H2 50.920 3.70% 50.919 3.69% 50.630 2.14% 50.631 2.14%
MES:C3-H4 49.932 49.931 49.118 49.118
MES:C1-H2υ 51.527 51.524 51.048 51.049
DSS:Met-H9 0.498 0.498 0.556 0.556 0.498 0.498 0.476 0.476

3-hydroxybutyrate:CH3 0.248 0.248 0.307 0.307 0.637 0.637 0.615 0.615
Acetate:CH3 0.927 0.927 0.985 0.985 1.170 1.170 1.149 1.149
Ala:Cα-H1 5.514 5.244 5.566 5.296 6.203 5.917 6.184 5.898
Ala:Cβ-H3 4.974 7.28% 5.027 7.20% 5.631 6.83% 5.612 6.86%
Asp:Cα-H1 0.849 0.849 0.907 0.907 1.316 1.316 1.294 1.294
Betaine:Met-H9 0.232 0.232 0.290 0.290 0.136 0.136 0.114 0.114
Carnitine:Met-H9 7.930 7.930 7.979 7.979 10.110 10.110 10.093 10.093
Choline:C1-H2 3.789 3.852 3.843 3.906 4.749 4.661 4.729 4.641
Choline:C2-H2 3.557 8.58% 3.612 8.45% 4.596 1.70% 4.576 1.71%
Choline:Met-H9 4.209 4.263 4.637 4.617
Creatine:C2-H2 0.918 0.905 0.975 0.963 1.482 1.292 1.460 1.270
Creatine:CH3 0.893 1.93% 0.951 1.81% 1.101 20.83% 1.080 21.19%
Glu:Cγ-H2 10.215 11.257 10.261 11.302 11.524 11.982 11.507 11.965
Glu:Cβ-H2 12.298 13.09% 12.342 13.02% 12.440 5.41% 12.423 5.42%
Gly:Cα-H2 7.873 7.873 7.923 7.923 10.746 10.746 10.729 10.729
Ile:Cδ-H3 0.850 0.897 0.908 0.954 1.442 1.229 1.420 1.207
Ile:Cγ2-H3 0.943 7.29% 1.001 6.84% 1.015 24.55% 0.994 24.99%
Lactate:C2-H1 19.628 19.973 19.663 20.009 24.074 22.539 24.062 22.527
Lactate:CH3 20.319 2.45% 20.354 2.44% 21.003 9.63% 20.991 9.64%
Leu:Cα-H1 1.881 2.086 1.938 2.143 2.282 2.486 2.261 2.465
Leu:Cβ-H2 1.930 11.92% 1.986 11.59% 2.010 16.56% 1.989 16.71%
Leu:Cδ2-H3Π 2.104 2.160 2.756 2.735
Leu:Cδ1-H3 2.431 2.487 2.895 2.874
Lys:Cβ-H2 1.323 1.117 1.380 1.175 2.203 2.408 2.182 2.387
Lys:Cδ-H2 0.912 26.01% 0.969 24.71% 2.614 12.08% 2.593 12.19%
Met:Cγ-H2* 0.437 0.432 0.495 0.490
Met:Cε-H3 0.427 1.61% 0.485 1.41% 0.693 0.693 0.671 0.671
Ornithine:C3-H2 0.627 0.627 0.685 0.685 1.901 1.901 1.879 1.879
Pantothenate:CbH3* 0.181 0.368 0.240 0.426
Pantothenate:CaH3*Π 0.555 71.81% 0.613 61.90%
Ser:Cα-H1 2.095 1.947 2.151 2.003 2.660 2.680 2.639 2.660
Ser:Cβ-H2 1.799 10.75% 1.856 10.44% 2.701 1.09% 2.680 1.10%
Succinate:(CH2)2 5.840 5.840 5.892 5.892 7.253 7.253 7.234 7.234
Taurine:C1-H2υ 0.301 0.568 0.360 0.626 0.740 0.794 0.718 0.773
Taurine:C2-H2 0.835 66.42% 0.893 60.18% 0.849 9.65% 0.827 9.92%
Thr:Cα-H1 1.215 1.288 1.272 1.346 1.231 1.487 1.210 1.466
Thr:Cβ-H1 1.362 8.05% 1.419 7.70% 1.743 24.34% 1.722 24.71%
Val:Cα–H1 2.239 1.971 2.295 2.027 3.354 2.485 3.334 2.464
Val:Cγ1-H3 1.838 11.78% 1.895 11.44% 2.004 30.33% 1.983 30.61%
Val:Cγ2-H3 1.835 1.891 2.098 2.076
α–Glucose:C1-H1 38.908 38.908 38.921 38.921 44.253 44.253 44.251 44.251
β–Glucose:C1-H1 71.314 71.314 71.288 71.288 75.910 75.910 75.922 75.922
%αG 35.30% 35.32% 36.83% 36.82%

Data were analyzed as in Table 1. Π and υ signify overlapped peaks.

*

Peaks (red) were missing in spectra of sample without Fe(III)EDTA.

DISCUSSION

Gradient-selective HSQCi (gsHSQCi) led to cleaner spectra and the partial removal of t1 noise ridges (Supporting Information, Figure S1). The strength of the t1 noise usually is proportional to the intensity of related peaks. Therefore, the measured concentrations for compounds present at high concentration in the mixture usually are less precise than those from compounds present at moderate concentrations. By using a content-defined model mixture of metabolites to evaluate the performance of the approach, (Table 1), comparable precision and accuracy were obtained by manual integration and by semi-automated Newton-FMLR analysis.12 The gsHSQC0 approaches (both constant-time and non-constant-time) yielded better precision, but no better accuracy than phase-cycled HSQC0. Data analyzed by Newton-FMLR showed better accuracy with two-parameter (k and b) fitting than with one-parameter (k) fitting, but comparable precision was obtained for both cases. With manual integration, the two fitting approaches yielded equivalent results.

As explained in the Supporting Information, to avoid quadrature imaginary artifacts in gsHSQC2 and gsHSQC3 spectra, which arise from gradient refocusing among HSQC units, different selective gradient pairs must be used in each HSQC block. Using different selective gradient pairs in each HSQCi block could cause the signal attenuation factors fA,n to be different in each HSQCi block; however, our experimental results revealed that this effect is negligible (Supporting Information, Tables S1 and S2). Similar gsHSQC0 peak volumes and calculated concentrations were obtained from gsHSQCi data acquired with different sets of selective gradients (Figure 3 (1) and (2)).

Concentrations were determined for all components in the mixture by manual integration (direct summation) of peak volumes and by Newton-FMLR analysis to extract the peak amplitudes in HSQCi spectra. 12 These concentrations were found to be comparable (Supporting Information, Tables S1A–S8A), which shows that the semi-automated approach should be applicable to quick metabolite profiling.

To explore the performance of the approach on a real biological metabolite sample, we applied the gsHSQC0 with semi-automated FMLR data analysis to quantify individual metabolites in a bovine liver extract. Concentrations of 23 metabolites were determined. Overall, concentrations determined from the samples with and without relaxation enhancing agent were in agreement, but the latter sample required a much longer acquisition time. With the acquisition time for each gsHSQCi of 3 h for the bovine liver extract sample with relaxation enhancing agent, the lower limit of measurable concentration was on the order of 0.1 mM. For example, the concentration of betaine was 0.2–0.3 mM, and the concentration of methionine was 0.4–0.5 mM. Glucose was the compound with the highest concentration: 120 mM for the sum of the alpha and beta anomers.

We recently applied the non-constant-time gsHSQC0 approach to selectively quantify a natural product of thiocoraline present at a level of 1% w/w (equivalent concentration of the pure compound ~0.1 mM) in a complex extract mixture from a Verrucosispora sp. isolated from the sponge Chondrilla caribensis f. caribensis. 13

The use of gradient selection can greatly suppress spectral noise, especially t1 noise from compounds present at relatively high concentrations in the mixture. Compared to the phase-cycled HSQC0 approach,9 the signal amplitudes in gsHSQCi attenuate faster by the factor of ½ due to the gradient selection (Eq 3 and 4). This is reflected in the generally more negative slopes of the linear regression plots of ln Ai,n vs. i (Figure 3). Thus, signals from very dilute compounds may decay and become very weak in the HSQC3 spectrum. In such cases, it is better to acquire only two spectra (HSQC1 and HSQC2) and to determine the A0,n values from:

2A0,n=A1,n2/A2,n (6)

CONCLUSIONS

We recently proposed 1H-13C zero-time HSQC (HSQC0) 9 spectroscopy as a way to extend quantitative NMR from 1D proton (1D qHNMR) to two dimensions in order to improve peak resolution and quantification. We next extended the approach to make use of two internal concentration references and semi-automated analysis by Newton-FMLR.12 Our original approach utilized a phase-cycled constant-time HSQC pulse sequence. Here we evaluate three additional pulse sequences and compare them with the original. The new approaches utilize gradient selection for quadrature detection in place of phase-cycled quadrature detection: (1) gradient-selective constant-time with gradient set 1, (2) gradient-selective constant-time with gradient set 2, and (3) gradient-selective non-constant-time. Gradient selection yields HSQCi spectra with fewer spectral artifacts and can improve the precision of peak amplitude measurements for more intense peaks. Apart from this, data from all four approaches are amenable to analysis either by manual integration or by semi-automated Newton-FMLR analysis,12 and all four yield concentration measurements of comparable accuracy. The performance of the approach on a real biological metabolite sample was evaluated by analyzing a bovine liver extract. We collected gsHSQC0 data and analyzed the results with semi-automated FMLR to determine the concentrations of 23 metabolites present in the extract. In this case, the lower limit of measurable concentration was on the order of 0.1 mM and the highest concentration measured was about 120 mM. We anticipate that this new protocol for 2D 1H-13C spectroscopy will prove valuable for automatic metabolite profiling by simultaneous quantification of multiple metabolites in a complex mixture.

Supplementary Material

1_si_001

Acknowledgments

This work was supported by the NIH National Center for Research Resources (grants P41 RR02301 and 3P41 RR02301-25S1) and by the DOE Great Lakes Bioenergy Research Center (DOE Office of Science BER DE-FC02-07ER64494).

Footnotes

SUPPORTING INFORMATION AVAILABLE

Additional information as noted in the text. This material is available free of charge via the Internet at http://pubs.acs.org.

References

  • 1.Wishart DS. TrAC-Trends Anal Chem. 2008;27:228–237. [Google Scholar]
  • 2.Piotto M, Moussallieh FM, Dillmann B, Imperiale A, Neuville A, Brigand C, Bellocq JP, Elbayed K, Namer IJ. Metabolomics. 2009;5:292–301. [Google Scholar]
  • 3.Zhang F, Dossey AT, Zachariah C, Edison AS, Bruschweiler R. Anal Chem. 2007;79:7748–7752. doi: 10.1021/ac0711586. [DOI] [PubMed] [Google Scholar]
  • 4.Zhang FL, Brüschweiler R. Angew Chem Int Edit. 2007;46:2639–2642. doi: 10.1002/anie.200604599. [DOI] [PubMed] [Google Scholar]
  • 5.Pauli GF, Jaki BU, Lankin DC. J Nat Prod. 2005;68:133–149. doi: 10.1021/np0497301. [DOI] [PubMed] [Google Scholar]
  • 6.Akoka S, Barantin L, Trierweiler M. Anal Chem. 1999;71:2554–2557. doi: 10.1021/ac981422i. [DOI] [PubMed] [Google Scholar]
  • 7.Rai RK, Tripathi P, Sinha N. Anal Chem. 2009;81:10232–10238. doi: 10.1021/ac902405z. [DOI] [PubMed] [Google Scholar]
  • 8.Lewis IA, Schommer SC, Hodis B, Robb KA, Tonelli M, Westler WM, Suissman MR, Markley JL. Anal Chem. 2007;79:9385–9390. doi: 10.1021/ac071583z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Hu KF, Westler WM, Markley JL. J Am Chem Soc. 2011;133:1662–1665. doi: 10.1021/ja1095304. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Poulding S, Charlton AJ, Donarski J, Wilson JC. J Magn Reson. 2007;189:190–199. doi: 10.1016/j.jmr.2007.09.004. [DOI] [PubMed] [Google Scholar]
  • 11.Chylla RA, Volkman BF, Markley JL. J Biomol NMR. 1998;12:277–297. doi: 10.1023/a:1008254432254. [DOI] [PubMed] [Google Scholar]
  • 12.Chylla RA, Hu K, Ellinger JJ, Markley JL. Anal Chem. 2011;83:4871–4880. doi: 10.1021/ac200536b. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Hu KF, Wyche TP, Bugni TS, Markley JL. J Nat Prod. 2011 doi: 10.1021/np200503c. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

1_si_001

RESOURCES