Abstract
We describe a new surgical technique adopted for the repair of Stanford type A aortic dissection. In order to minimize the risk of malperfusion caused by retrograde flow during cardiopulmonary bypass, we avoid femoral artery cannulation. On the hypothesis that it is best not to interfere with the hemodynamics of the dissection, we cannulate the dissected ascending aorta, in either the true or false lumen. We here report 2 cases of successful surgical treatment of Stanford type A aortic dissection. In both cases, the false lumen was cannulated under deep hypothermic circulatory arrest, without clamping the aorta. While the patient was cooling, a 10-mm GORE-TEX side arm was sutured to a Dacron graft prosthesis. Repair of the aortic arch was carried out 1st. The aortic cannula was inserted into the GORE-TEX side arm, the tubular prosthesis was cross-clamped, and cardiopulmonary bypass was reinstituted. After this, the aortic bulb was repaired as usual and the tubular prosthesis was sutured to the bulb. No postoperative cerebral complication occurred. Our experience must be confirmed by more cases and a longer follow up.
Full text
PDF


Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Cooley D. A., Livesay J. J. Technique of "open" distal anastomosis for ascending and transverse arch resection. Cardiovasc Dis. 1981 Sep;8(3):421–426. [PMC free article] [PubMed] [Google Scholar]
- Laas J., Jurmann M. J., Heinemann M., Borst H. G. Advances in aortic arch surgery. Ann Thorac Surg. 1992 Feb;53(2):227–232. doi: 10.1016/0003-4975(92)91323-2. [DOI] [PubMed] [Google Scholar]
- NIAZI S. A., LEWIS F. J. Profound hypothermia in man; report of a case. Ann Surg. 1958 Feb;147(2):264–266. doi: 10.1097/00000658-195802000-00019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Parr G. V., Manley N. J., Williams D. R., Montesano R. M. Obstruction of the true lumen during retrograde perfusion of type I aortic dissections: a simplified solution. Ann Thorac Surg. 1980 Nov;30(5):495–498. doi: 10.1016/s0003-4975(10)61305-7. [DOI] [PubMed] [Google Scholar]
- Robicsek F., Guarino R. L. Compression of the true lumen by retrograde perfusion during repair of aortic dissection. J Cardiovasc Surg (Torino) 1985 Jan-Feb;26(1):36–40. [PubMed] [Google Scholar]
- Robicsek F., Zimmern S. H., Howe H. R. Subintimal retrograde perfusion during repair of aortic dissection: a potential cause of disaster. Ann Vasc Surg. 1988 Jul;2(3):298–302. doi: 10.1016/S0890-5096(07)60018-1. [DOI] [PubMed] [Google Scholar]


