Abstract
This report describes the successful use of an autologous cephalic vein-coated coronary stent to exclude an aneurysm of the distal right coronary artery. Post-implantation angiography confirmed successful exclusion of the aneurysm with no evidence of leakage. Intravascular ultrasonography showed complete apposition of the stent to the arterial wall proximal and distal to the aneurysm. The vein could be seen clearly around the stent. Symmetrical stent expansion (minimal luminal diameter, 2.8 mm) was verified. Increased echogenicity in the excluded aneurysm indicated early thrombus formation. Evidently, this is the 1st report of the successful use of an autologous cephalic vein-coated coronary stent to exclude an aneurysm of the distal right coronary artery.
Full text
PDF


Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Chae J. K., Park S. W., Kim Y. H., Hong M. K., Park S. J. Successful treatment of coronary artery perforation during angioplasty using autologous vein graft-coated stent. Eur Heart J. 1997 Jun;18(6):1030–1032. doi: 10.1093/oxfordjournals.eurheartj.a015362. [DOI] [PubMed] [Google Scholar]
- Colon P. J., 3rd, Ramee S. R., Mulingtapang R., Pridjian A., Bhatia D., Collins T. J. Percutaneous bailout therapy of a perforated vein graft using a stent-autologous vein patch. Cathet Cardiovasc Diagn. 1996 Jun;38(2):175–178. doi: 10.1002/(SICI)1097-0304(199606)38:2<175::AID-CCD11>3.0.CO;2-I. [DOI] [PubMed] [Google Scholar]
- Kaplan B. M., Stewart R. E., Sakwa M. P., O'Neill W. W. Repair of a coronary pseudoaneurysm with percutaneous placement of a saphenous vein allograft attached to a biliary stent. Cathet Cardiovasc Diagn. 1996 Feb;37(2):208–212. doi: 10.1002/(SICI)1097-0304(199602)37:2<208::AID-CCD23>3.0.CO;2-E. [DOI] [PubMed] [Google Scholar]
- Schuler G., Hambrecht R., Schlierf G., Niebauer J., Hauer K., Neumann J., Hoberg E., Drinkmann A., Bacher F., Grunze M. Regular physical exercise and low-fat diet. Effects on progression of coronary artery disease. Circulation. 1992 Jul;86(1):1–11. doi: 10.1161/01.cir.86.1.1. [DOI] [PubMed] [Google Scholar]
- Stefanadis C., Toutouzas K., Vlachopoulos C., Stratos C., Kallikazaros I., Karayannakos P., Gravanis M. M., Robinson K., Toutouzas P. Stents wrapped in autologous vein: an experimental study. J Am Coll Cardiol. 1996 Oct;28(4):1039–1046. doi: 10.1016/s0735-1097(96)00267-7. [DOI] [PubMed] [Google Scholar]
- Stefanadis C., Toutouzas K., Vlachopoulos C., Tsiamis E., Kallikazaros I., Stratos C., Vavuranakis M., Toutouzas P. Autologous vein graft-coated stent for treatment of coronary artery disease. Cathet Cardiovasc Diagn. 1996 Jun;38(2):159–170. doi: 10.1002/(SICI)1097-0304(199606)38:2<159::AID-CCD8>3.0.CO;2-8. [DOI] [PubMed] [Google Scholar]
- Stefanadis C., Tsiamis E., Vlachopoulos C., Toutouzas K., Giatrakos N., Tsioufis C., Diamantopoulos L., Toutouzas P. Arterial autologous graft-stent for treatment of coronary artery disease: a new technique. Cathet Cardiovasc Diagn. 1997 Mar;40(3):302–307. doi: 10.1002/(sici)1097-0304(199703)40:3<302::aid-ccd20>3.0.co;2-p. [DOI] [PubMed] [Google Scholar]
- Stefanadis C., Tsiamis E., Vlachopoulos C., Toutouzas K., Stratos C., Kallikazaros I., Vavuranakis M., Toutouzas P. Autologous vein graft-coated stents for the treatment of thrombus-containing coronary artery lesions. Cathet Cardiovasc Diagn. 1997 Feb;40(2):217–222. doi: 10.1002/(sici)1097-0304(199702)40:2<217::aid-ccd25>3.0.co;2-m. [DOI] [PubMed] [Google Scholar]
- Wong S. C., Kent K. M., Mintz G. S., Pichard A. D., Satler L. F., Garcia J., Hong M. K., Popma J. J., Leon M. B. Percutaneous transcatheter repair of a coronary aneurysm using a composite autologous cephalic vein-coated Palmaz-Schatz biliary stent. Am J Cardiol. 1995 Nov 1;76(12):990–991. doi: 10.1016/s0002-9149(99)80281-1. [DOI] [PubMed] [Google Scholar]