Abstract
Stentless xenograft aortic valves were designed to provide superior hemodynamic characteristics and durability, in comparison with stented tissue valves. The senior author (MJR) has implanted 46 St. Jude Toronto stentless porcine valves--with excellent hemodynamic results and no aortic insufficiency--since this valve was released by the Food and Drug Administration in November 1997. Because the implantation technique is significantly different from that of implanting a stented valve, and because proper implantation is critical for proper valve function and avoidance of aortic insufficiency, we discuss our technique in some detail.
Full text
PDF




Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BARRATT-BOYES B. G. HOMOGRAFT AORTIC VALVE REPLACEMENT IN AORTIC INCOMPETENCE AND STENOSIS. Thorax. 1964 Mar;19:131–150. doi: 10.1136/thx.19.2.131. [DOI] [PMC free article] [PubMed] [Google Scholar]
- ROSS D. N. Homograft replacement of the aortic valve. Lancet. 1962 Sep 8;2(7254):487–487. doi: 10.1016/s0140-6736(62)90345-8. [DOI] [PubMed] [Google Scholar]
- Ross D. N. Replacement of aortic and mitral valves with a pulmonary autograft. Lancet. 1967 Nov 4;2(7523):956–958. doi: 10.1016/s0140-6736(67)90794-5. [DOI] [PubMed] [Google Scholar]