Skip to main content
The Canadian Journal of Plastic Surgery logoLink to The Canadian Journal of Plastic Surgery
. 2011 Autumn;19(3):93–96. doi: 10.1177/229255031101900305

Contribution of breast density to the volume of the augmented breast: A preliminary study

Sean M Hill 1,, Franziska Huettner 1, John Murray 1, Eric Elwood 1, Rebecca Barrick 1, Glyn Jones 1
PMCID: PMC3269329  PMID: 22942658

Breast augmentation is one of the most common procedures performed, and obtaining symmetry and the correct postoperative volume is of the utmost importance. Currently, three-dimensional analysis is used to calculate breast volume, shape, size, etc, which aids the surgeon in deciding on the correct implant size. This study used three-dimensional analysis on 38 breasts (21 women) to measure breast volume and compare it with the implant size, in addition to comparing the results with breast density on mammogram.

Keywords: Breast, Breast augmentation, Breast density, Breast implant, Breast implant size, Mammographic density

Abstract

BACKGROUND:

Prediction of soft tissue contribution to the shape, volume and texture of the augmented breast proves to be an ever-challenging, uncontrollable variable. Similarly, the understanding of the contribution of breast density in breast augmentation has been elusive and, generally, not well studied.

OBJECTIVE:

With the aid of three-dimensional photographic analysis, the present preliminary study examined the contribution of differing breast densities to the overall volume of the augmented breast.

METHODS:

All patients undergoing primary augmentation over a six-month period were included in the study. To standardize technique and implant type, all patients received saline-filled moderate-profile implants, which were placed partially underneath the pectoralis muscle through a lower pole approach. Photographic analysis of the breast volume was completed preoperatively and, subsequently, at a minimum of six months postoperatively. Preoperatively, each breast was also assigned to one of four classes of increasing mammographic density, as judged by the mammographic radiologist (fatty, moderately dense, heterogeneously dense and extremely dense). Postoperative breast volumes were, subsequently, correlated to mammographic densities.

RESULTS:

Thirty-eight augmented breasts in 21 patients were examined. The average volume gain based on the implant size used was 92.7%. Heterogeneously dense breasts comprised 68% of the total breasts and showed an average volume gain of 100.67%, extremely dense breasts comprised 26% of the total breasts and showed an average volume gain of 97.3%, and moderately dense breasts comprised 5% of the total breasts with an average gain of 100.04%. There was no significant difference between the augmented breast volumes and the respective expected volumes (combined preaugmented breast volumes and implant volumes; P=0.3483). Additionally, no statistical difference was found between the density classes and the expected augmented volumes.

CONCLUSION:

No statistical difference was found between expected and actual augmented breast volumes among or between four different breast density classes. Thus, one would expect that the soft tissue compression or the response of the impression of the implant on the parenchyma, would not be statistically different among classes. Additionally, compressive atrophy, as seen with atrophy of the breasts over time, would be expected to be multifactorial and not uniquely independent to breast density. However, longitudinal analysis is needed to study the durability of breast shape relative to breast density.


Breast reconstruction and augmentation plays an important role in the field of plastic surgery. The procedure can help a woman feel complete, and can re-establish her emotional balance and self-esteem after suffering through a horrifying battle. Breast augmentation is one of the five most common procedures performed by plastic surgeons (1). Women undergo this procedure for mainly two reasons: bilateral hypoplasia of the breast or asymmetry of the breasts due to breast reconstruction of the contralateral side as a consequence of cancer surgery. In both situations, it is most important to try to meet the patient’s expectations and to create two symmetrical breasts. In previous years, breast reconstruction and augmentation has relied on the surgeon’s subjective appreciation of breast tissue characteristics matched with technique and knowledge of wound healing to achieve an aesthetically pleasing result. Currently, three-dimensional digital analysis offers the ability to objectively define anatomical subtleties to refine surgical technique through its capacity to calculate breast volume, surface area, shape, size and contour (2).

Baseline volume data can be objectively collected before deciding on the correct implant size to match the cancer-free breast. To improve the outcome of breast augmentation, factors such as patient age and breast density on mammogram must be evaluated. The purpose of the present study was to objectively measure the truly created breast volume (using three-dimensional photography) and compare it with the implant size used for augmentation; furthermore, the study compared the results with breast density on mammogram. The resulting volume and the actual implant size used for augmentation were subsequently compared with breast density on mammogram. The hypothesis was that a younger, more dense breast results in compression of the breast implant and, therefore, leads to smaller true breast volumes when compared with the implant size.

PATIENTS AND METHODS

The present institutional review board-approved retrospective study describes the use of three-dimensional photography (3dMDtorso, 3dMD, USA) for analysis of the augmented breast.

The 3dMDtorso system is a 12-camera system that is based on the principles of stereophotogrammetry to be able to capture the patient’s image in 1.5 ms and to generate a highly precise, digital three-dimensional model of the human anatomy (Figures 1 and 2).

Figure 1).

Figure 1)

Preoperative breast image with 3dMDtorso (3dMD, USA) reconstruction. The outlined area represents the Coons patch used to calculate volume. The four corners represent the sternal notch, crossing of the anterior axillary line and pectoralis muscle, crossing of the anterior axillary line and horizontal line beneath the breast, and crossing of the midline torso and horizontal line beneath the breast

Figure 2).

Figure 2)

Postoperative breast image with 3dMDtorso (3dMD, USA) reconstruction. The outlined area represents the Coons patch used to calculate volume. The four corners represent the sternal notch, crossing of the anterior axillary line and pectoralis muscle, crossing of the anterior axillary line and horizontal line beneath the breast, and crossing of the midline torso and horizontal line beneath the breast

A series of patients at the Illinois Plastic Surgery Center (USA) who had undergone breast augmentation over a six-month period for either bilateral hypoplasia or unilateral augmentation for symmetry were chosen. Twenty-one patients representing a total number of 38 breasts were evaluated. Augmentation for breast hypoplasia was performed in 17 cases, and for symmetry reasons in four cases. Preoperative, informed patient consents for the procedure and photography were obtained. To qualify for the study, the patients needed to have had a three-dimensional photograph taken both before and at a minimum of six months postoperatively using the 3dMD technology. The breast volumes were measured pre- and postoperatively using a Coons patch.

Four different points on the patients’ torsos were chosen for calculation purposes, and these same points were used in every patient: sternal notch, crossing of the anterior axillary line and pectoralis muscle, crossing of the anterior axillary line and horizontal line beneath the breast, and crossing of the midline torso and horizontal line beneath the breast (Figure 1). The 3dMDtorso system calculated the volume of the breast. The authors were unable to place the point at the exact same pixel on the screen; therefore, the error in measurement was accounted for by calculating the mean of three measurements per breast. Pre- and postoperative volumes were compared and the difference was calculated. The calculated volume difference was converted to percentage of volume gain, relative to the implant size, which was 100%. The results were compared with breast density obtained by mammogram.

Statistical analysis was performed using a paired t test (Graphed Quick Cals, Graphed Software Inc, USA).

RESULTS

Thirty-eight breasts of 21 women (average age 38.2 years [range 19 to 58 years]) were transformed into three-dimensional images. The mean implant size used was 305.79 mL. The mean volume difference measured was 282.96 mL. The mean volume gain was 92.7% (range 58.7% to 130.2%) (Table 1).

TABLE 1.

Preoperative (preop) and postoperative (postop) breast volume, volume gained and the volume of breast implant used

Patient Breast Age, years Density Preop volume, mL Postop volume, mL Volume difference, mL Implant volume, mL Volume gain, %
1 1 39 hd 104.26 482.54 378.28 400 94.57
2 39 hd 115.81 520.67 404.86 400 101.22
2 3 27 hd 142.46 485.67 343.21 340 100.94
4 27 hd 150.91 479.89 328.98 330 99.69
3 5 44 hd 327.19 522.49 195.30 150 130.20
4 6 56 hd 175.15 349.61 174.46 150 116.31
5 7 58 hd 194.12 430.19 236.07 200 118.03
6 8 47 hd 168.13 441.07 272.94 215 126.95
7 9 27 ed 203.18 632.67 429.49 400 107.37
10 27 ed 202.68 610.60 407.92 400 101.98
8 11 19 hd 299.90 431.85 131.94 200 65.97
12 19 hd 329.24 429.09 99.85 170 58.73
9 13 36 hd 279.91 617.42 337.52 300 112.51
14 36 hd 257.22 621.37 364.15 300 121.38
10 15 29 md 262.59 628.80 366.21 375 97.66
16 29 md 268.93 652.98 384.06 375 102.42
11 17 20 ed 198.95 541.41 342.46 300 114.15
18 20 ed 165.05 494.18 329.13 315 104.49
12 19 36 hd 308.67 730.82 422.15 375 112.57
20 36 hd 321.36 729.57 408.21 375 108.86
13 21 27 ed 371.10 679.72 308.62 300 102.87
22 27 ed 306.45 659.42 352.97 325 108.61
14 23 35 hd 252.95 560.60 307.65 300 102.55
24 35 hd 231.53 561.65 330.12 300 110.04
15 25 37 hd 269.46 631.00 361.54 375 96.411
26 37 hd 315.57 642.11 326.54 350 93.297
16 27 34 hd 279.87 600.00 320.13 315 101.630
28 34 hd 286.27 593.27 307.00 320 95.938
17 29 27 ed 345.25 645.00 299.75 300 99.917
30 27 ed 318.08 664.00 345.92 325 106.440
18 31 40 hd 232.42 505.12 272.7 275 99.164
32 40 hd 253.91 494.49 240.58 275 87.484
19 33 39 hd 206.51 431.17 224.66 200 112.330
34 39 hd 314.90 488.91 174.01 200 87.005
20 35 25 hd 122.35 436.35 314.00 360 87.222
36 25 hd 134.83 411.37 276.54 360 76.817
21 37 26 ed 95.60 314.76 219.16 335 65.421
38 26 ed 113.12 320.11 206.99 335 61.788
Mean, n 282.96 305.79 92.720

‘Volume gain, %’ is a measurement of the postop volume observed divided by volume expected and multiplied by 100 to convert to a percentage. Density represents the observed mammographic density. ed Extremely dense; hd Heterogeneously dense; md Moderately dense

With regard to breast density on the mammogram, all breasts were classified as dense. Heterogeneously dense breasts comprised 68% of the total breasts and showed an average volume gain of 100.67%, extremely dense breasts comprised 26% of the total breasts and showed an average volume gain of 97.3%, and moderately dense breasts comprised 5% of the total breasts with an average gain of 100.04%.

There was no significant difference between the augmented breast volumes and the respective expected volumes (combined preaugmented breast volumes and implant volumes) (P=0.3483). No statistical difference was found between the density classes and the expected augmented volumes.

DISCUSSION

Breast augmentation is one of the most commonly performed procedures in the field of plastic surgery, with the breast being the universal symbol of femininity and sexuality. Obtaining symmetrical breast size and the proper postoperative volume for the patient is of the upmost importance in breast surgery. However, no universally accepted method for calculating breast volumes exists.

Determining the volume and implant size needed for unilateral augmentation after breast reconstruction of the contralateral side or the most aesthetically pleasing volume in bilateral augmentation is critical. Tebbets (3) proposed his TEPID system to evaluate individual tissue characteristics to determine the size of implant that would give the most aesthetically pleasing breast. This system addresses the tissue characteristics (T) of the envelope (E), the parenchyma (P), and the implant (I), and the dynamics (D) of the implant and filler distribution that affects the soft tissue (3). This system was revised in 2005 with the high five support process, which allowed all preoperative planning to be accomplished in 5 min (4). The first decision is optimal soft tissue coverage/pocket location of the implant, which eliminates future risk of rippling, and visible or palpable edges. Second is the implant volume, which takes into account the effect on the tissue over time, resulting in rippling or ptosis over time. Third is the implant size, type and dimensions, which control the distribution of the implant within the breast. Fourth is consideration for the optimal location of the inframammary fold, which is based on the width of the implant chosen for augmentation. This dimension is critical to the aesthetic relationship between the breast width and nipple-to-fold distance, and distribution of fill. Finally, the fifth decision is incision location. Using this system, Tebbets and Adams (4) reported a reoperation rate of 3% at seven-year follow-up.

The evaluation of reoperative breast volume up to this point was subjective or dependent on two-dimensional photographs, photographic stereograms (such as magnetic resonance imaging [MRI], computed tomography and ultrasound) or traditional anthropomorphic measurements (5) (such as the Archimedean water displacement method [6], plaster molds and mammograms). These methods are all limited in evaluating the shape, volume and symmetry of the breast.

In contrast, three-dimensional imaging provides a better spatial understanding of anatomical structures to be treated, which can lead to improvement in planning treatment and surgical approach. The 3dMD system has been shown to produce consistent, reproducible, observer-independent, accurate results (7) without exposing the patient to radiation (2). It is also minimally invasive, fast and practical, and causes no breast deformity or pain to the patient. Three-dimensional imaging is currently being used for objective evaluation of breast asymmetry (7) because of its ability to quantify breast size and shape, surface area, volume, contour and surface measurement. It is a technology that is revolutionizing the way we plan and document procedures, and can possibly lead to an improvement for better communication.

The accuracy of three-dimensional surface imaging was tested by Kovacs et al (8) in 2006 when they compared the precision and accuracy of three-dimensional scanning with MRI (8). Five independent observers measured the volume of six test subjects using a three-dimensional scanning system, and these volumes were compared with those using MRI. It was found that the volume obtained using three-dimensional surface imaging correlated with MRI measurements. An additional study by Kovacs et al (9) in 2007 compared three-dimensional scanning with other classical methods to assess volume. Repeated breast volume measurement was performed using a three-dimensional laser scanner, nuclear MRI, thermoplastic castings and anthropomorphic measurements. When comparing these volumes, it was found that three-dimensional scanning measurement showed the best agreement with MRI compared with the others (9). These studies further validate this method as a quick, cost-effective and accurate alternative to MRI in volume assessment for breast surgery.

The technical feasibility and clinical utility of three-dimensional geometric data were demonstrated by Tepper et al (10) by obtaining three-dimensional scans for patients undergoing short-scar medial pedicle breast reduction. Both pre- and postoperative three-dimensional models were obtained for 30 patients. These models demonstrated that a significant change in tissue percentage was located above the inframammary fold postoperatively (76%) compared with preoperatively (45%) (10).

Overall, three-dimensional photography is safe (no exposure to radiation), simple (12 cameras taking one picture simultaneously), convenient (no special room necessary), easy (can be operated by clinical staff) and noninvasive; it can truly become a valuable instrument in breast surgery procedures. Additional studies are necessary to assess its value in both reconstructive and aesthetic breast surgery; however, early results are promising.

CONCLUSION

No statistical difference was found between expected and actual augmented breast volumes among or between four different breast density classes. Thus, one would expect that the soft tissue compression or the response of the impression of the implant on the parenchyma would not be statistically different among classes. Additionally, compressive atrophy, as seen with atrophy of the breasts over time, would be expected to be multifactorial and not uniquely independent to breast density. However, longitudinal analysis will be needed to study the durability of breast shape relative to breast density.

REFERENCES

  • 1.Rohrich RJ. The increasing popularity of cosmetic surgery procedures: A look at statistics in plastic surgery. Plast Reconstr Surg. 2000;106:1363–5. doi: 10.1097/00006534-200011000-00023. [DOI] [PubMed] [Google Scholar]
  • 2.Nahabedian MY, Galdino G. Symmetrical breast reconstruction: Is there a role for three-dimensional digital photography? Plast Reconstr Surg. 2003;112:1582–90. doi: 10.1097/01.PRS.0000085818.54980.C4. [DOI] [PubMed] [Google Scholar]
  • 3.Tebbets JB. A system for breast implant selection based on patient tissue characteristics and implant – soft tissue dynamics. Plast Reconstr Surg. 2002;109:1396–409. doi: 10.1097/00006534-200204010-00030. [DOI] [PubMed] [Google Scholar]
  • 4.Tebbets JB, Adams WP. Five critical decisions in breast augmentation using five measurements in 5 minutes: The high five decision support process. Plast Reconstr Surg. 2005;116:2005–16. [PubMed] [Google Scholar]
  • 5.Wesreich M. Anthropomorphic breast measurement: Protocol and results in 50 women with aesthetically perfect breasts and clinical application. Plast Reconstr Surg. 1997;100:468–79. doi: 10.1097/00006534-199708000-00032. [DOI] [PubMed] [Google Scholar]
  • 6.Tezel E, Numanoglu A. Practical do-it-yourself device for accurate volume measurement of breast. Plast Reconstr Surg. 2000;105:1019–23. doi: 10.1097/00006534-200003000-00028. [DOI] [PubMed] [Google Scholar]
  • 7.Losken A, Seify H, Denson DD, Paredes AA, Carlson G. Validating three-dimensional imaging of the breast. Ann Plast Surg. 2005;54:471–6. doi: 10.1097/01.sap.0000155278.87790.a1. [DOI] [PubMed] [Google Scholar]
  • 8.Kovacs L, Eder M, Hollweck R, et al. New aspects of breast volume measurement using 3-dimensional surface imaging. Ann Plast Surg. 2006;57:602–10. doi: 10.1097/01.sap.0000235455.21775.6a. [DOI] [PubMed] [Google Scholar]
  • 9.Kovacs L, Eder M, Hollweck R, et al. Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast. 2007;16:137–45. doi: 10.1016/j.breast.2006.08.001. [DOI] [PubMed] [Google Scholar]
  • 10.Tepper OM, Choi M, Small K, et al. An innovative three-dimensional approach to defining the anatomical changes occurring after short scar-medial pedicle reduction mammaplasty. Plast Reconstr Surg. 2008;121:1875–85. doi: 10.1097/PRS.0b013e31817151db. [DOI] [PubMed] [Google Scholar]

Articles from The Canadian Journal of Plastic Surgery are provided here courtesy of Pulsus Group

RESOURCES