. 2011 Aug 11;44(12):2250–2258. doi: 10.1016/j.jbiomech.2011.05.041

Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements

Jordi Alastruey a,b,, Ashraf W Khir c, Koen S Matthys c, Patrick Segers d, Spencer J Sherwin b, Pascal R Verdonck d, Kim H Parker a, Joaquim Peiró b
PMCID: PMC3278302  PMID: 21724188

Abstract

The accuracy of the nonlinear one-dimensional (1-D) equations of pressure and flow wave propagation in Voigt-type visco-elastic arteries was tested against measurements in a well-defined experimental 1:1 replica of the 37 largest conduit arteries in the human systemic circulation. The parameters required by the numerical algorithm were directly measured in the in vitro setup and no data fitting was involved. The inclusion of wall visco-elasticity in the numerical model reduced the underdamped high-frequency oscillations obtained using a purely elastic tube law, especially in peripheral vessels, which was previously reported in this paper [Matthys et al., 2007. Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurements. J. Biomech. 40, 3476–3486]. In comparison to the purely elastic model, visco-elasticity significantly reduced the average relative root-mean-square errors between numerical and experimental waveforms over the 70 locations measured in the in vitro model: from 3.0% to 2.5% (p<0.012) for pressure and from 15.7% to 10.8% (p<0.002) for the flow rate. In the frequency domain, average relative errors between numerical and experimental amplitudes from the 5th to the 20th harmonic decreased from 0.7% to 0.5% (p<0.107) for pressure and from 7.0% to 3.3% (p<106) for the flow rate. These results provide additional support for the use of 1-D reduced modelling to accurately simulate clinically relevant problems at a reasonable computational cost.

Keywords: Pulse wave propagation, Experimental modelling, One-dimensional modelling, Time-domain formulation, Voigt-type visco-elasticity, Systemic arterial tree

Highlights

► We test the accuracy of the nonlinear 1-D equations of blood flow in large arteries. ► We compare wave measurements in a silicone tree with numerical predictions. ► 1-D modelling is able to capture the main features of pulse waveforms. ► Simulation of wall visco-elasticity significantly decreases relative errors. ► Energy losses at bifurcations have a secondary effect on pulse waveforms.

1. Introduction

Pressure and flow pulse waveforms carry information on the functionality of the cardiovascular system and the morphology of the arterial network, which can be valuable for the diagnosis and treatment of disease. Modelling allows us to study the effect on pulse waveforms of the physical properties of the system, such as arterial geometry and distensibility, cardiac output, heart rate and peripheral impedance to flow, and analyse the mechanisms underlying clinically relevant changes (Stergiopulos et al., 1992; Wang and Parker, 2004; Mynard and Nithiarasu, 2008; Liang et al., 2009). In particular, it allows us to test clinical diagnostic techniques that are based on pulse wave analysis and disentangle their underlying mechanisms (Karamanoglu et al., 1994; Trachet et al., 2010; Alastruey et al., 2006; Alastruey, 2011). These studies can be extremely challenging in vivo for technical and physiological reasons; e.g. some vessels are inaccessible, manipulation of the properties of interest can be dangerous or can elicit reflex compensation, and several parameters of interest are not directly measurable.

We have previously shown the ability of the nonlinear 1-D equations of pulse wave propagation in elastic vessels to capture the main features of pressure and flow waveforms measured in well-defined experimental 1:1 replicas of the larger conduit arteries in the human systemic circulation (Segers et al., 1998; Segers and Verdonck, 2000; Alastruey, 2006; Matthys et al., 2007). Matthys et al. (2007) reported average relative root-mean-square errors between numerical and experimental waveforms smaller than 3.5% for pressure and 19% for the flow rate at 70 locations in the tapered silicone network sketched in Fig. 1. Much of these errors arose from relatively high-frequency oscillations in the peripheral vessels predicted in the numerical model but not seen in the experimental measurements. Wall viscosity was suggested to play an important role in damping oscillations in the numerical pulse waveforms, but this hypothesis could not be tested since a purely elastic tube law was used in the 1-D model.

Fig. 1.

Fig. 1

(left) Planview schematic of the 1:1 hydraulic model of the 37 larger conduit arteries in the human systemic circulation. Arteries were simulated using silicone tubes. 1: Pump (left heart); 2: catheter access; 3: aortic valve; 4: peripheral resistance tube; 5: stiff plastic tubing (veins); 6: venous overflow; 7: venous return conduit; 8: buffering reservoir; 9: pulmonary veins. The arrows indicate the location of the results shown in Figs. 3 to 5. (right) Topology and reference labels of the arteries simulated, whose properties are given in Table 1. (Modified from Matthys et al., 2007.)

Recent works have shown the benefits of modelling the arterial wall using a visco-elastic law. Bessems et al. (2008) tested a visco-elastic 1-D formulation against in vitro data measured in single tapered polyurethane vessels, showing that wall visco-elasticity is necessary to accurately predict the propagation and attenuation of pressure and flow waves. Reymond et al. (2009) compared the predictions of a visco-elastic 1-D distributed model of the human arterial tree with average pressure and flow waveforms measured at several arterial locations in a group of young subjects. Qualitative comparison of these waveforms and quantitative comparison of systolic, diastolic and mean pressure and flow indicated that the visco-elastic effects may be significant, especially in peripheral branches. They argued that energy losses and damping effects due to wall visco-elasticity are of the same order of magnitude as wall friction in large and medium size vessels. However, the parameters of their model were not specific to each subject.

Several works (Armentano et al., 1995a,b; Craiem et al., 2005; Čanić et al., 2006) have used Voigt-type visco-elastic models to simulate the visco-elastic behaviour of human and animal arteries, and improve the agreement between measured and simulated pulse waveforms. These models feature hysteresis (different stress–strain relationship for loading and unloading) and creep (continuous extension at constant load).

The aim of this work is to study the role of visco-elasticity in explaining the discrepancies of the results presented in Matthys et al. (2007). We will use a nonlinear, time-domain 1-D formulation that simulates the arterial wall as a Voigt-type visco-elastic material. Except for the shape of the velocity profile, the parameters required by the numerical algorithm will be directly measured in the in vitro setup and no data fitting will be involved. We will, therefore, provide an assessment of nonlinear visco-elastic 1-D modelling by comparison against in vitro measurements in a well-defined arterial network with tapered vessels. The notation and SI units of the quantities used in this paper are given in Table 1.

Table 1.

Notation and SI units.

A (m2) Luminal cross-sectional area
A0 (m2) Initial luminal cross-sectional area
c0(ms1) Initial pulse wave speed
E (Pa) Young's modulus of silicone
EP (%) Relative pressure error over one cardiac cycle
EP¯ (%) Relative mean pressure error
EP^ (%) Relative error of the amplitude of the pressure harmonics over one cardiac cycle
EQ (%) Relative flow rate error over one cardiac cycle
EQ¯ (%) Relative mean flow rate error
EQ^ (%) Relative error of the amplitude of the flow harmonics over one cardiac cycle
F (N) Load in the uniaxial extension test
Fmax (N) Maximum load in the uniaxial extension test
f(Nm1) Friction force per unit length of vessel
freq (Hz) Wave frequency
h (m) Vessel wall thickness
Je (m) Jacobian of the elemental mapping from Ωst
Lp Legendre polynomial of order p used for the expansion of the numerical solution
N Total number of samples in one cardiac cycle
Nel Number of elemental regions Ωe in the numerical mesh of an arterial segment
P (Pa) Average internal pressure over the luminal cross-section
Pe (Pa) Elastic component of pressure
Pext (Pa) External (or extramural) pressure
P^ (Pa) Amplitude of the pressure harmonic
P Order of the polynomial space of the expansion bases used for the numerical solution
Q(m3s1) Volume flow rate
Q^(m3s1) Amplitude of the flow harmonic
Q Order of the Gauss-Lobatto-Legendre quadrature used in the numerical solution
Rp(Pasm3) Peripheral resistance of a terminal vessel
r (m) Luminal radius
r0 (m) Initial luminal radius
t (s) Time
tini (s) Initial time in a load–unload cycle of the uniaxial extension test
tend (s) Final time in a load–unload cycle of the uniaxial extension test
U(ms1) Average axial velocity over the luminal cross-section
x (m) Axial coordinate along the vessel
xel (m) Axial coordinate of the lower point of the elemental region Ωe
xeu (m) Axial coordinate of the upper point of the elemental region Ωe
β (Pa m) Parameter related to the elastic tone of silicone
Γ (Pa s m) Parameter related to the viscosity of silicone
Δt (s) Time step of the numerical simulation
ϵ Tensile strain of silicone
ϵini Initial tensile strain in a load–unload cycle of the uniaxial extension test
ϵend Final tensile strain in a load–unload cycle of the uniaxial extension test
η (m) Change of radius of the vessel wall
μ (Pa s) Viscosity of the water–glycerol mixture
ξ Non-dimensional coordinate of the domain Ωst
ρ(kgm3) Density of the water–glycerol mixture
σ Poisson's ratio of silicone
τ (Pa) Tensile stress of silicone
φ (Pa s) Viscosity of silicone
ψ (m) Extension in the uniaxial extension test
ψmax (m) Maximum extension in the uniaxial extension test
Ω Arterial domain of the spatial discretisation
Ωe Elemental region in Ω
Ωst Reference (or standard) domain of the spatial discretisation

2. Methods

2.1. Visco-elastic 1-D formulation

Conservation of mass and momentum applied to a 1-D impermeable and deformable tubular control volume of incompressible and Newtonian fluid flowing with a constant axisymmetric velocity profile yields (Sherwin et al., 2003)

At+(AU)x=0,Ut+UUx+1ρPx=fρA, (1)

where x is the axial coordinate along the vessel, t the time, A(x,t) the cross-sectional area of the lumen, U(x,t) the average axial velocity, P(x,t) the average internal pressure over the cross-section, and f=22μπU (Alastruey, 2006) the friction force per unit length. The constant density and viscosity of the 65–35% water–glycerol mixture used to mimic blood were ρ=1050kgm3 and μ=2.5mPas, respectively.

We have modelled the silicone used to make the experimental arteries as a Voigt-type material; i.e. its tensile stresses τ and strains ϵ are related through (Fung, 1993)

τ=Eϵ+φdϵdt, (2)

where E is the Young's modulus and φ the viscosity of silicone. Assuming the in vitro arterial walls to be thin, isotropic, homogeneous and incompressible, and to deform axisymmetrically, each circular cross-section independently of the others, τ can be related to the internal pressure P and ϵ to the change of radius of the vessel wall η=rr0 using Laplace's law (Olufsen et al., 2000)

τ=r(PPext)h,ϵ=11σ2ηr0, (3)

where r=A/π, h(x) is the wall thickness, σ=0.5 the Poisson's ratio and r0(x) the luminal radius at P=Pext; Pext being the constant external pressure (Matthys et al., 2007). Combining Eqs. (2) and (3) and assuming that 1/r can be approximated by 1/r0 yields

P=Pext+4Eh3(r0)2η+4φh3(r0)2ηt. (4)

Expressing η as a function of A=πr2 and A0=π(r0)2, yields the visco-elastic tube law

P=Pext+βA0(AA0)+ΓA0AAt, (5)
β=43πEh,Γ=23πφh.

The parameters β(x) and Γ(x) are related to the elastic and visco-elastic properties of the arterial wall, respectively. It is important to remark that Eq. (5) can also be derived from a generalised string model (Quarteroni et al., 2000; Formaggia et al., 2003).

2.2. Numerical solution

Eqs. (1) and (5) were solved in the 37 arterial segments of the hydraulic model in Fig. 1 using a discontinuous Galerkin scheme with a spectral/hp spatial discretisation. This is a convenient scheme for high-order discretisation of convection-dominated flows (Cockburn and Shu, 1998), such as arterial flows. It allows us to propagate waves of different frequencies without suffering from excessive dispersion and diffusion errors.

Eqs. (1) and (5) can be written in the following conservative form:

Ut+Fx=SU,

with

U=AU,SU=0fρA,
F=Fe+Fv=AUU22+Pext+Peρ+0ΓρA0A(AU)x,

and Pe=(β/A0)(AA0) being the elastic component of pressure. The flux F was separated into an elastic (Fe) and a viscous (Fv) term, and the mass conservation A/t=(AU)/x was applied to change the time derivative to a spatial derivative in the viscous term of Eq. (5).

The discrete form of this conservative law in a domain Ω discretised into a mesh of Nel elemental non-overlapping regions Ωe=[xel,xeu], such that xeu=xe+1l for e=1,,Nel1, and e=1NelΩe=Ω is given by (Karniadakis and Sherwin, 2005; Alastruey, 2006)

e=1NelUδt,ψδΩe+F(Uδ)x,ψδΩe+[ψδ·{FuF(Uδ)}]xelxeu=e=1Nel(SUδ,ψδ)Ωe, (6)

for all ψδ in Vδ, where (u,v)Ω=Ωuvdx is the standard L2(Ω) inner product, Uδ and ψδ denote the approximation of U and test functions ψ, respectively, in the finite space Vδ of piecewise polynomial vector functions (they may be discontinuous across inter-element boundaries), and Fu=Feu+Fvu is the approximation of the flux at the interface.

The term Feu was treated through the solution of a Riemann problem as described by Alastruey (2006). The term Fvu requires a different treatment. Various ways of dealing with this term were analysed by Zienkiewicz et al. (2003) and the references therein. Here, Fvu at the inter-element boundaries was approximated as

Fvu|xeu=Fvu|xe+1l=12(Fv|xeu+Fv|xe+1l),e=1,,Nel1,

with Fvu|x1l=Fv|x1l at the inlet of the domain and Fvu|xNelu=Fv|xNelu at the outlet, so that FvuFv(Uδ)=0 at both boundaries.

The expansion bases were selected to be a polynomial space of order P and the solution was expanded on each region Ωe in terms of Legendre polynomials Lp(ξ); i.e.

Uδ|Ωe(xe(ξ),t)=p=0PLp(ξ)U^ep, (7)

where U^ep(t) are the expansion coefficients. Legendre polynomials are particularly convenient because the basis is orthogonal with respect to the L2(Ωe) inner product. Following standard finite element techniques, the following elemental affine mapping was introduced:

xe(ξ)=xel(1ξ)2+xeu(1+ξ)2,

with ξ in the reference element Ωst={1ξ1}.

The choice of discontinuous discrete solution and test functions allows us to decouple the problem on each element, the only link coming through the boundary fluxes. Substitution of (7) into (6) and letting ψδ|Ωe=Uδ|Ωe, yields 2P equations to be solved for each Ωe, e=1,,Nel,

dU^i,epdt=F(Uδ|Ωe),p=0,,P,i=1,2, (8)

where U^i,ep,i=1,2 are the two components of U^ep,

F(Uδ|Ωe)=Fix,LpΩe1Je[Lp[FiuFi(Uδ|Ωe)]]xelxeu+(Si(Ueδ),Lp)Ωe,

and Je=12(xeuxel) is the Jacobian of the elemental mapping from Ωst. For every Ωe, Uδ|Ωe was evaluated at Gauss–Lobatto–Legendre quadrature points of order Q to evaluate the integrals (Fi/x,Lp)Ωe and (Si,Lp)Ωe. All spatial derivatives were calculated using collocation differentiation at the quadrature points (Karniadakis and Sherwin, 2005).

Arterial segments were divided into non-overlapping elements with a 2 cm length, when possible, and a polynomial and quadrature order of 3. Elements or segments shorter than 1.5 cm were given a polynomial and quadrature order of 2. Zero pressures and velocities were considered as initial conditions.

The discretisation in time was performed by a second-order Adams–Bashforth scheme. The time step was Δt=100μs for the elastic case and Δt=20μs for the visco-elastic case, since the convection Δt scales like the square of the polynomial order P, whereas the diffusion Δt scales like twice the square of P (Karniadakis and Sherwin, 2005). Although Δt had to be reduced in the visco-elastic model, it is still practical to use an explicit scheme because of the small P used and the fact that wave speeds are much larger than flow velocities.

Visco-elasticity was neglected at the boundary conditions of the network and the junctions, which were implemented as described in Matthys et al. (2007, Section 2.2.3) for both the purely elastic and visco-elastic models.

2.3. Numerical parameters from in vitro data

Table 2 shows the geometry, elasticity and boundary conditions required by the elastic and visco-elastic formulations, which were measured in the silicone network without any parameter fitting, as we detailed in Matthys et al. (2007). Most of the arterial segments were linearly tapered and their wall thickness decreased toward distal locations. Their Young's modulus was approximately constant (1.2 MPa), since they were made of the same silicone material. We assumed Pext=0 since the experimental setup was not submerged in water.

Table 2.

Data of the 37 silicone vessels in the in vitro model (Fig. 1). r0inr0out: initial luminal radii at the inlet and the outlet; h: average wall thickness; c0inc0out: initial wave speed at the inlet and the outlet; Γ: wall viscosity parameter; Rp: peripheral resistance calculated from mean pressure and flow rate measurements close to the outlet of each terminal branch. Single numbers indicate vessels with a constant cross-section. The interval of confidence of the geometrical measurements is indicated in the heading.

Arterial segment Length (mm) ±2.0% r0inr0out (mm) ±3.5% h (mm) ±2.5% c0inc0out (ms1) Γ (Pa s m) Rp(GPasm3)
1. Ascending aorta 36 14.4013.00 0.51 5.215.49 1.82
2. Innominate 28 11.007.29 0.35 4.896.01 1.23
3. R. carotid 145 5.373.86 0.28 6.357.49 1.01 2.67
4. R. subclavian I 218 4.363.34 0.27 6.877.84 0.96
5. R. subclavian II 165 3.342.78 0.16 6.006.58 0.56
6. R. radial 235 2.07 0.15 7.43 0.53 3.92
7. R. ulnar 177 2.10 0.21 8.81 0.76 3.24
8. Aortic arch I 21 13.0012.50 0.50 5.415.52 1.77
9. L. carotid 178 5.583.73 0.31 6.558.00 1.11 3.11
10. Aortic arch II 29 12.5011.80 0.41 4.985.12 1.44
11. L. subclavian I 227 4.423.39 0.22 6.217.10 0.79
12. L. subclavian II 175 3.392.84 0.17 6.266.84 0.62
13. L. radial 245 2.07 0.21 8.84 0.75 3.74
14. L. ulnar 191 2.07 0.16 7.77 0.58 3.77
15. Thoracic aorta I 56 11.8011.00 0.43 5.295.48 1.53
16. Intercostals 195 4.123.22 0.27 7.077.99 0.96 2.59
17. Thoracic aorta II 72 11.009.26 0.34 4.845.26 1.19
18. Celiac I 38 3.97 0.20 6.20 0.71
19. Celiac II 13 4.31 1.25 14.90 4.43
20. Splenic 191 1.83 0.13 7.24 0.45 3.54
21. Gastric 198 1.92 0.11 6.73 0.40 4.24
22. Hepatic 186 3.312.89 0.21 6.957.44 0.74 3.75
23. Abdominal aorta I 62 9.268.01 0.33 5.195.59 1.16
24. L. renal 120 2.59 0.19 7.39 0.66 3.46
25. Abdominal aorta II 7 7.90 0.35 5.83 1.25
26. R. renal 118 2.55 0.16 6.95 0.57 3.45
27. Abdominal aorta III 104 7.805.88 0.30 5.416.24 1.06
28. R. iliac-femoral I 205 3.93.38 0.21 6.476.94 0.76
29. R. iliac-femoral II 216 3.382.31 0.15 5.897.13 0.55
30. R. iliac-femoral III 206 2.312.10 0.20 8.048.44 0.69
31. L. iliac-femoral I 201 4.023.34 0.20 6.196.79 0.72
32. L. iliac-femoral II 195 3.342.26 0.16 6.117.44 0.58
33. L. iliac-femoral III 207 2.262.12 0.13 6.676.89 0.47
34. R. anterior tibial 163 1.55 0.15 8.47 0.52 5.16
35. R. posterior tibial 151 1.53 0.12 7.73 0.43 5.65
36. L. posterior tibial 149 1.58 0.11 7.23 0.38 4.59
37. L. anterior tibial 126 1.55 0.10 7.01 0.35 3.16

Here we estimated φ (which was not measured in Matthys et al., 2007) from an uniaxial extension test in a sample of the same silicone material used in the experimental setup. Fig. 2 (top) shows the extension ψ and measured load F used in the test, which were normalised by their corresponding maximum values Fmax and ψmax. The test was carried out using a tensometer and 1 kN load cell (Instron 5542, High Wycombe, UK), loading and unloading at a rate of 20 mm min1 to a maximum extension of 1 mm. Three consecutive loading and unloading cycles were followed by 30 s at zero extension, loading to maximum extension which was held for 60 s before the final unloading to zero extension.

Fig. 2.

Fig. 2

(top) Experimental uniaxial load and extension with time for a sample of the silicone used in the experimental arterial network. (bottom) Load-extension loop for the first load–unload cycle, whose direction is indicated by the arrows. A cubic spline was fitted to the loading and unloading points measured in the extension test. Loads and extensions are shown normalised by their corresponding maximum values.

A cubic spline was fitted to F(t) and ψ(t), separating loading and unloading. Stresses τ(t) were calculated as the ratio of F and the cross-sectional area of the sample, and strains ϵ(t) as the ratio of ψ(t) and the initial sample length. Fig. 2 (bottom) shows the Fψ-loop for the first loading–unloading cycle (only the first cycle is shown for clarity; the following cycles were similar with no evidence of conditioning). We calculated φ as

φ=ϵiniϵendτdϵtinitenddϵdt2dt, (9)

which follows from integrating both sides of Eq. (2) over one load–unload cycle and using ϵiniϵendEϵdϵ=0. The limits of the integrals are the initial (tini, ϵini) and final (tend, ϵend) time and strain in a load–unload cycle, with ϵini=ϵend. We obtained φ=3.0±0.3kPas.

2.4. Error calculations

To assess the accuracy of the numerical predictions of pressure P and volume flow rate Q=AU, the following relative errors were calculated at each measuring site,

EP=1Ni=1NPiexpPiPiexp2,EQ=1Ni=1N(QiexpQi)2max(Qexp),
EP¯=(mean(Pexp)mean(P))2mean(Pexp),EQ¯=(mean(Qexp)mean(Q))2mean(Qexp), (10)

where N is the total number of samples in one cardiac cycle, the subscript i indicates the sampling point (the sampling rate was 1 kHz), the superscript exp indicates experimental data, the operator max(·) calculates the maximum value within i=1,,N, and mean(·) calculates the mean value within i=1,,N. In the frequency domain, we calculated

EP^=1Mj=1M(P^jexpP^j)2P^1exp,EQ^=1Mj=1M(Q^jexpQ^j)2Q^1exp, (11)

where M is the total number of harmonics and P^j and Q^j are the amplitudes of the pressure and flow jth harmonic, respectively.

3. Results

Fig. 3 compares the ensemble averaged experimental waveforms at four locations with the numerical predictions obtained using both the elastic and the visco-elastic 1-D formulations. As in the purely elastic study, we matched the onset of the experimental and numerical systolic ejections. These comparisons are representative of the results obtained at other measurement sites and show the ability of visco-elasticity to reduce the high-frequency oscillations produced by the elastic formulation, especially in peripheral vessels.

Fig. 3.

Fig. 3

Experimental (exp) and simulated elastic (elas) and visco-elastic (visc) pressure (left) and flow (right) waveforms in the midpoint of the thoracic aorta I, left renal artery, right iliac-femoral III artery and right carotid artery in the hydraulic model in Fig. 1. Note the different scales of flow rates.

Wall visco-elasticity reduces relative errors for pressure and the flow rate in the time domain for all the 70 measurement sites. Table 3 shows these errors for both the (original) purely elastic and the (new) visco-elastic formulations in the midpoint of the arterial segments, and Table 4 shows average relative errors over all 70 measuring sites, and over all the sites in the aorta and the vessels of the first, second and third generation of bifurcations.

Table 3.

Relative errors (in %) of the numerical pulse waveforms calculated using Eqs. (10) and (11) in the midpoint of the arterial segments in Fig. 1. Errors in the frequency domain (Eq. (11)) were calculated for the first five pressure (EP^ I) and flow (EQ^ I) harmonics (j=1,,5), and from the 5th to the 20th pressure (EP^ II) and flow (EQ^ II) harmonics (j=5,,20). They are expressed relative to the amplitude of the first experimental pressure or flow harmonic. All errors are given as a pair of numbers: the first corresponds to the purely elastic formulation (elas) and the second to the visco-elastic formulation (visc).

Arterial segmenta EP (%)
EQ (%)
EP¯ (%)
EQ¯ (%)
EP^ I (%) 1–5 harm.
EQ^ I (%) 1–5 harm.
EP^ II (%) 5–20 harm.
EQ^ II (%) 5–20 harm.
elas visc elas visc elas visc elas visc elas visc elas visc elas visc elas visc
1. Ascending aorta 1.0 0.7 0.0 0.0 0.6 0.5 0.0 0.0 0.5 0.4 0.0 0.0 0.2 0.1 0.0 0.0
2. Innominate 2.7 2.5 10.7 9.0 2.7 2.7 12.6 12.5 0.9 0.9 6.4 6.3 0.2 0.2 5.8 2.9
3. R. carotid 1.9 1.7 19.9 5.5 0.7 0.8 0.5 0.0 0.8 0.8 5.1 5.1 0.5 0.2 15.7 3.1
4. R. subclavian I 2.9 2.6 27.3 22.5 2.9 2.9 14.9 14.5 1.7 1.6 30.2 29.6 0.4 0.3 4.3 2.7
5. R. subclavian II 2.5 2.3 14.0 10.8 3.2 3.2 11.8 11.7 0.8 0.8 21.9 21.1 0.3 0.3 9.2 5.8
6. R. radial 2.2 1.4 11.0 7.2 1.5 1.4 7.1 7.0 1.6 1.5 7.6 7.2 0.2 0.1 4.1 2.6
7. R. ulnar 2.3 1.2 8.2 4.7 1.3 1.2 4.5 4.3 1.3 1.2 3.8 3.3 0.5 0.3 2.3 1.6
8. Aortic arch I 2.0 1.7 7.0 6.1 0.1 0.1 2.5 2.4 0.8 0.7 8.4 8.3 0.2 0.1 1.9 1.2
9. L. carotid 2.6 2.5 12.2 5.9 2.5 2.4 3.0 3.0 0.8 0.8 6.9 6.3 0.4 0.3 13.8 4.5
10. Aortic arch II 1.5 1.2 10.6 9.5 0.3 0.2 8.8 8.4 0.5 0.4 15.0 14.7 0.1 0.1 3.3 2.9
11. L. subclavian I 2.9 2.7 7.8 6.6 3.5 3.5 5.5 5.4 0.8 0.8 21.5 19.5 0.3 0.2 6.4 3.8
12. L. subclavian II 2.6 2.4 12.5 11.7 3.8 3.8 7.4 7.4 1.4 1.4 12.8 12.3 0.5 0.4 5.4 3.8
13. L. radial 2.7 2.4 9.1 7.8 2.9 2.9 6.2 6.2 1.7 1.7 2.8 2.7 0.3 0.3 3.9 2.4
14. L. ulnar 2.7 2.4 11.1 10.3 3.1 3.1 11.4 11.4 1.6 1.6 3.9 3.8 0.3 0.3 3.5 2.8
15. Thoracic aorta I 1.1 0.9 11.3 10.9 0.1 0.1 19.2 19.2 0.7 0.6 15.7 15.3 0.1 0.1 4.8 3.0
16. Intercostals 2.1 1.9 15.1 7.3 2.9 2.9 4.3 4.2 0.9 0.9 3.8 3.4 0.5 0.3 9.0 4.3
17. Thoracic aorta II 1.9 1.6 19.4 18.8 1.9 1.9 1.0 1.0 0.5 0.4 39.3 38.7 0.2 0.1 8.1 5.7
18. Celiac I 3.8 3.3 13.7 8.1 2.7 2.6 2.2 2.1 1.1 1.0 7.0 6.2 0.3 0.2 10.6 6.5
20. Splenic 3.1 1.9 7.8 5.2 1.9 1.9 8.6 8.5 1.8 1.6 3.7 3.6 0.6 0.3 3.1 1.4
21. Gastric 2.8 1.7 15.2 10.0 1.7 1.7 6.3 6.2 1.4 1.1 4.6 4.5 0.7 0.2 8.8 2.2
22. Hepatic 2.3 1.6 12.9 6.8 2.6 2.5 0.7 0.5 0.7 0.7 4.5 4.5 0.3 0.2 10.0 5.2
23. Abdominal aorta I 2.0 1.6 18.7 16.4 1.9 1.9 9.7 9.7 0.8 0.7 29.6 28.7 0.3 0.2 7.9 4.8
24. L. renal 3.0 2.9 11.9 5.6 2.4 2.3 5.1 4.9 1.0 1.0 4.2 4.1 0.6 0.3 6.6 2.7
26. R. renal 2.9 2.7 12.0 5.5 2.8 2.8 3.5 3.4 0.8 0.8 4.3 3.9 0.3 0.2 6.4 2.5
27. Abdominal aorta III 2.7 2.4 20.8 18.2 2.7 2.6 3.0 3.0 1.2 1.1 35.7 34.4 0.3 0.2 6.1 3.4
28. R. iliac-femoral I 3.0 2.7 35.3 30.5 3.2 3.1 10.6 10.7 0.8 0.8 19.1 18.6 0.5 0.4 17.4 7.7
29. R. iliac-femoral II 1.9 1.6 20.6 16.3 1.5 1.4 11.9 11.8 5.4 5.4 36.9 33.7 4.2 4.0 12.0 7.5
30. R. iliac-femoral III 2.0 1.7 13.9 11.3 1.1 1.1 12.5 12.5 1.5 1.5 13.4 10.0 0.6 0.4 7.6 3.2
31. L. iliac-femoral I 5.5 4.1 26.3 23.2 3.5 3.5 35.4 34.1 2.2 2.2 30.5 27.7 0.9 0.7 11.1 7.6
32. L. iliac-femoral II 5.5 5.1 21.5 21.4 2.9 2.8 12.4 12.4 5.2 5.2 28.4 26.3 1.2 0.9 8.0 4.9
33. L. iliac-femoral III 4.7 4.0 11.2 9.1 3.5 3.4 7.8 7.8 1.2 1.2 9.5 7.7 0.8 0.6 7.0 2.9
34. R. anterior tibial 5.6 4.7 11.9 9.1 2.4 2.3 8.3 8.3 4.8 4.5 4.6 3.7 1.6 1.1 5.2 3.7
35. R. posterior tibial 3.0 2.3 8.2 6.7 3.1 3.0 7.7 7.7 1.8 1.7 5.5 5.3 1.4 1.1 3.7 2.3
36. L. posterior tibial 5.9 4.6 11.4 10.3 2.0 2.0 8.0 8.0 5.4 5.4 6.2 6.0 1.5 1.3 4.3 2.4
a

We did not take in vitro measurements at the celiac II (Segment 19), abdominal aorta II (Segment 25) and left anterior tibial (Segment 37).

Table 4.

Average relative errors (in %) of the numerical pulse waveforms over all 70 measuring sites, and over all the sites in the aorta and the vessels of the first, second and third generation of bifurcations. Single errors were calculated as described in Table 2. The standard deviation is given for each error. The probability p of the two-sample t-test is given for the average errors over all 70 measuring sites assuming equal variances.

Arterial segments EP (%)
EQ (%)
EP¯ (%)
EQ¯ (%)
EP^ I (%) 1–5 harm.
EQ^ I (%) 1–5 harm.
EP^ II (%) 5–20 harm.
EQ^ II (%) 5–20 harm.
elas visc elas visc elas visc elas visc elas visc elas visc elas visc elas visc
All 3.0 2.5 15.7 10.8 2.8 2.8 7.1 7.0 1.6 1.5 13.4 12.4 0.7 0.5 7.0 3.3
±1.0 ±1.0 ±5.6 ±5.5 ±0.8 ±0.8 ±6.0 ±5.9 ±1.3 ±1.2 ±11.5 ±10.1 ±0.6 ±0.5 ±3.6 ±1.7
p<0.012 p<0.002 p<0.414 p<0.458 p<0.339 p<0.231 p<0.107 p<106
Aorta 1.7 1.5 13.6 11.4 1.3 1.3 4.9 4.9 0.7 0.6 20.5 20.0 0.3 0.2 4.5 3.0
±0.5 ±0.5 ±6.9 ±6.5 ±0.8 ±0.8 ±6.0 ±5.8 ±0.2 ±0.2 ±13.5 ±12.1 ±0.1 ±0.0 ±2.6 ±1.3
1st generation 3.5 3.2 18.8 13.1 3.0 3.0 9.7 9.7 1.7 1.7 14.4 13.1 0.9 0.7 9.3 4.7
±1.2 ±1.0 ±7.6 ±6.9 ±0.6 ±0.6 ±7.5 ±7.2 ±1.2 ±1.2 ±11.1 ±9.3 ±0.9 ±0.8 ±3.1 ±1.8
2nd generation 3.5 3.0 15.8 11.0 3.0 3.0 6.9 6.9 2.1 2.0 9.7 8.6 0.8 0.6 6.6 3.2
±1.4 ±1.2 ±5.8 ±4.9 ±0.7 ±0.7 ±4.6 ±4.6 ±1.4 ±1.4 ±9.2 ±7.2 ±0.5 ±0.4 ±3.8 ±1.1
3rd generation 2.3 1.1 11.3 6.6 1.6 1.5 6.8 6.7 1.5 1.2 5.1 4.5 0.5 0.2 4.6 1.9
±0.5 ±0.5 ±3.1 ±2.2 ±0.3 ±0.3 ±1.6 ±1.6 ±0.2 ±0.2 ±1.7 ±1.6 ±0.2 ±0.1 ±2.7 ±0.4

For both formulations, relative errors are larger for the flow rate than for pressure. If visco-elasticity is modelled, the averaged pressure EP and flow EQ errors over all measuring sites are significantly decreased (from 3.0% to 2.5% and from 15.7% to 10.8%, respectively). Variations in φ of ±0.3kPas (the standard deviation of the measured φ) leads to non-significant changes in the previous errors of less than 0.05% for pressure and 0.2% for the flow rate. Changes in the errors for mean pressures EP¯ and flow rates EQ¯ are not significant if visco-elasticity is modelled (Table 4).

In the frequency domain, the visco-elastic formulation produces greater decreases in the relative errors of the amplitudes from the 5th to the 20th pressure EP^ and flow EQ^ harmonics than for the first five harmonics (Tables 3 and 4). Fig. 4 compares the amplitudes of the first 20 experimental flow harmonics in the midpoint of a vessel of the first generation of bifurcations, with the numerical predictions obtained using the elastic and the visco-elastic formulations. The latter captures these amplitudes better, especially with the increasing frequency. Similar results were obtained at the other locations studied.

Fig. 4.

Fig. 4

Spectrum of the flow harmonics Q^ on a semi-logarithm scale in the midpoint of the left renal artery (Fig. 1) of the experimental (crosses) and simulated elastic (circles) and visco-elastic (triangles) models.

The AP curves obtained using the visco-elastic model present an area of hysteresis that is much smaller than the area obtained from in vivo measurements (Armentano et al., 1995a,b; Valdez-Jasso et al., in press), as Fig. 5 shows in an aortic location. The numerical formulation predicts an increase in this area with the increasing wall viscosity φ (Fig. 5).

Fig. 5.

Fig. 5

Area–pressure curve in the midpoint of the thoracic aorta I (Fig. 1) simulated using the elastic (elas) and visco-elastic (visc) numerical models. We also show the curve obtained using the visco-elastic model with eight times the measured viscosity of silicone (8φ).

4. Discussion

We have shown that simulation of wall visco-elasticity decreases the relative root-mean-square errors of numerical pressure and flow predictions in the aorta and all the generations of bifurcations of the silicone model, in both the frequency and time domains.

According to our frequency–domain analysis, the damping effect due to visco-elasticity is more significant from the 5th flow harmonic (Table 4). This leads to a decrease in the high-frequency oscillations of the purely elastic model and supports the hypothesis suggested in Matthys et al. (2007) that visco-elasticity has a more significant effect on damping oscillations predicted by the purely elastic formulation (with higher amplitudes than those observed in vivo) than energy losses at junctions and peripheral compliances in the overflow reservoirs. The damping effect in the visco-elastic model is greater in distal vessels, which is in agreement with the increase in the viscous term of the tube law (5) with the decreasing cross-sectional area toward distal locations. The minor reductions in the relative errors of mean pressure and flow rate when visco-elasticity was modelled suggest that the effect of visco-elasticity on mean pressures and flow rates is secondary.

The relative errors of flow rate predictions were larger than corresponding pressure predictions, which is consistent with the larger uncertainty of the experimental flow measurements compared with the experimental pressure measurements discussed in Matthys et al. (2007). Additional uncertainties were introduced by changes in the boundary conditions of the experimental setup every time the pressure and flow transducers were repositioned. Indeed, significantly different errors were obtained between measured and predicted mean flow rates EQ¯ at several locations within the same vessel (e.g. Segments 31–33 in Table 3). The uncertainties in the measurement of the visco-elastic modulus were relatively small and did not introduce large errors in the numerical results. However, the uniaxial extension tests were carried out at a slower speed (about 6 s for a load–unload cycle) than the experimental inflow imposed by the pump (70 beats per minute). This difference may be responsible for some of the errors observed in the visco-elastic pressure and flow predictions.

Another limitation of this study is the use of a linear model to describe the dynamics of the vessel walls (Eq. (2)) that does not account for the stress relaxation observed in the uniaxial tests (Fig. 2, top). Models accounting for stress relaxation (Bessems et al., 2008; Devault et al., 2008; Valdez-Jasso et al., 2009), and the nonlinear behaviour of the wall (Reymond et al., 2009; Valdez-Jasso et al., in press) have been proposed, but their applicability to patient-specific 1-D modelling is more challenging, since more parameters must be estimated than in the Voigt model. We believe that a linear constitutive model is a reasonable approach, since wall deformations are small under normal physiological conditions. According to the 1-D visco-elastic results, changes in the diameter of the ascending aorta over the cardiac cycle are less than 6.5% of its mean diameter. These changes decrease toward distal locations.

Although the areas of hysteresis produced by the visco-elastic formulation (Fig. 5) are smaller than those observed in vivo, they are in agreement with the corresponding areas measured experimentally (Fig. 2, bottom). We could not assess the accuracy of the diameter waveforms predicted by the 1-D model, since we did not measure them experimentally. However, the area of hysteresis increases if a greater wall visco-elasticity φ=24kPas is used. This is a more physiological value according to data in Armentano et al. (1995b) and Gariepy et al. (1993) for the carotid and femoral arteries of normotensive men.

Using an anatomically realistic model of the arterial network, we have shown that wall viscosities about an order of magnitude smaller than those measured in the human play a significant role in shaping the high-frequency components of the pressure and flow waveforms, especially in the periphery. This result supports the qualitative observations by Reymond et al. (2009) in the human and our previous conclusion that energy losses at bifurcations have a secondary effect on the blood flow in large arteries compared to visco-elasticity (Matthys et al., 2007).

We have provided further evidence to support the conclusions given in the previous works (Segers et al., 1998; Segers and Verdonck, 2000; Olufsen et al., 2000; Alastruey, 2006; Matthys et al., 2007; Steele et al., 2007; Bessems et al., 2008; Reymond et al., 2009) about the ability of the 1-D formulation to capture the main features of pressure and flow wave propagation in large arteries (and hence the use of this mathematical model to simulate clinically relevant problems), if accurate measurements of the parameters of the model are provided. The 1-D formulation is computationally inexpensive (it takes the order of minutes to solve one cardiac cycle for a whole body model) and, hence, offers a good balance between accuracy and computational cost when a global assessment of pressure wave propagation in the cardiovascular system is required.

Conflict of interest statement

There are no conflicts of interest between the authors of this paper and other external researchers or organisations that could have inappropriately influenced this work.

Acknowledgements

The authors would like to acknowledge Ms. Ye Li, PhD candidate, for the excellent technical assistance in the mechanical testing, and our two anonymous reviewers for their valuable comments and suggestions. Jordi Alastruey acknowledges the support of a British Heart Foundation Intermediate Basic Science Research Fellowship (FS/09/030/27812).

Contributor Information

Jordi Alastruey, Email: jordi.alastruey-arimon@imperial.ac.uk.

Ashraf W. Khir, Email: ashraf.khir@brunel.ac.uk.

Koen S. Matthys, Email: koen.matthys@brunel.ac.uk.

Patrick Segers, Email: patrick.segers@ugent.be.

Spencer J. Sherwin, Email: s.sherwin@imperial.ac.uk.

Pascal R. Verdonck, Email: pascal.verdonck@ugent.be.

Kim H. Parker, Email: k.parker@imperial.ac.uk.

Joaquim Peiró, Email: j.peiro@imperial.ac.uk.

References

  1. Alastruey, J., 2006. Numerical Modelling of Pulse Wave Propagation in the Cardiovascular System: Development, Validation and Clinical Applications. Ph.D. Thesis, Imperial College London, University of London, UK.
  2. Alastruey J., Parker K., Peiro J., Sherwin S. Can the modified Allen's test always detect sufficient collateral flow in the hand? A computational study. Comp. Meth. Biomech. Biomed. Eng. 2006;9:353–361. doi: 10.1080/10255840600985477. [DOI] [PubMed] [Google Scholar]
  3. Alastruey J. Numerical assessment of time-domain methods for the estimation of local arterial pulse wave speed. J. Biomech. 2011;44:885–891. doi: 10.1016/j.jbiomech.2010.12.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Armentano R., Barra J., Levenson J., Simon A., Pichel R. Arterial wall mechanics in conscious dogs: assessment of viscous, inertial, and elastic moduli to characterize aortic wall behavior. Circ. Res. 1995;76:468–478. doi: 10.1161/01.res.76.3.468. [DOI] [PubMed] [Google Scholar]
  5. Armentano R., Megnien J., Simon A., Bellenfant F., Barra J., Levenson J. Effects of hypertension on viscoelasticity of carotid and femoral arteries in humans. Hypertension. 1995;26:48–54. doi: 10.1161/01.hyp.26.1.48. [DOI] [PubMed] [Google Scholar]
  6. Bessems D., Giannopapa C., Rutten M., van de Vosse F. Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels. J. Biomech. 2008;41:284–291. doi: 10.1016/j.jbiomech.2007.09.014. [DOI] [PubMed] [Google Scholar]
  7. Čanić S., Tambača J., Guidoboni G., Mikelić A., Hartley C., Rosenstrauch D. Modeling viscoelastic behavior of arterial walls and their interaction with pulsatile blood flow. SIAM J. Appl. Math. 2006;67:164–193. [Google Scholar]
  8. Cockburn B., Shu C.-W. The local discontinuous Galerkin method for time-dependent convection-diffusion systems. SIAM J. Numer. Anal. 1998;35:2440–2463. [Google Scholar]
  9. Craiem D., Graf S., Pessana F., Grignola J., Bia D., Gines F., Armentano R. Cardiovascular engineering: modelization of ventricular arterial interaction in systemic and pulmonary circulation. Latin Am. Appl. Res. 2005;35:111–114. [Google Scholar]
  10. Devault K., Gremaud P., Novak V., Olufsen M., Vernières G., Zhao P. Blood flow in the circle of Willis: modeling and calibration. Multiscale Model. Simul. 2008;7:888–909. doi: 10.1137/07070231X. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Formaggia L., Lamponi D., Quarteroni A. One-dimensional models for blood flow in arteries. J. Eng. Math. 2003;47:251–276. [Google Scholar]
  12. Fung Y. second ed. Springer-Verlag; New York: 1993. Biomechanics: Mechanical Properties of Living Tissues. [Google Scholar]
  13. Gariepy J., Massonneau M., Levenson J., Heudes D., Simon A. Evidence for in vivo carotid and femoral wall thickening in human hypertension. Groupe de Prevention Cardio-vasculaire en Medecine du Travail. Hypertension. 1993;22:111–118. doi: 10.1161/01.hyp.22.1.111. [DOI] [PubMed] [Google Scholar]
  14. Karamanoglu M., Gallagher D., Avolio A., O'Rourke M. Functional origin of reflected pressure waves in a multi-branched model of the human arterial system. Am. J. Physiol. Heart Circ. Physiol. 1994;267:H1681–H1688. doi: 10.1152/ajpheart.1994.267.5.H1681. [DOI] [PubMed] [Google Scholar]
  15. Karniadakis G., Sherwin S. Oxford University Press; New York: 2005. Spectral/hp Element Methods for Computational Fluid Dynamics. [Google Scholar]
  16. Liang F., Takagi S., Himeno R., Liu H. Biomechanical characterization of ventricular–arterial coupling during aging: a multi-scale model study. J. Biomech. 2009;42:692–704. doi: 10.1016/j.jbiomech.2009.01.010. [DOI] [PubMed] [Google Scholar]
  17. Matthys K., Alastruey J., Peiró J., Khir A., Segers P., Verdonck P., Parker K., Sherwin S. Pulse wave propagation in a model human arterial network: assessment of 1-D numerical simulations against in vitro measurements. J. Biomech. 2007;40:3476–3486. doi: 10.1016/j.jbiomech.2007.05.027. [DOI] [PubMed] [Google Scholar]
  18. Mynard J., Nithiarasu P. A 1D arterial blood flow model incorporating ventricular pressure, aortic valve and regional coronary flow using the locally conservative Galerkin (LCG) method. Commun. Numer. Methods Eng. 2008;24:367–417. [Google Scholar]
  19. Olufsen M., Peskin C., Kim W., Pedersen E., Nadim A., Larsen J. Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions. Ann. Biomed. Eng. 2000;28:1281–1299. doi: 10.1114/1.1326031. [DOI] [PubMed] [Google Scholar]
  20. Quarteroni A., Tuveri M., Veneziani A. Computational vascular fluid dynamics: problems, models and methods. Comput. Visual. Sci. 2000;2:163–197. [Google Scholar]
  21. Reymond P., Merenda F., Perren F., Rüfenacht D., Stergiopulos N. Validation of a one-dimensional model of the systemic arterial tree. Am. J. Physiol. Heart Circ. Physiol. 2009;297:208–222. doi: 10.1152/ajpheart.00037.2009. [DOI] [PubMed] [Google Scholar]
  22. Segers P., Dubois F., Wachter D.D., Verdonck P. Role and relevancy of a cardiovascular simulator. Cardiovasc. Eng. 1998;3:48–56. [Google Scholar]
  23. Segers P., Verdonck P. Role of tapering in aortic wave reflection: hydraulic and mathematical model study. J. Biomech. 2000;33:299–306. doi: 10.1016/s0021-9290(99)00180-3. [DOI] [PubMed] [Google Scholar]
  24. Sherwin S., Franke V., Peiró J., Parker K. One-dimensional modelling of a vascular network in space–time variables. J. Eng. Math. 2003;47:217–250. [Google Scholar]
  25. Steele B., Olufsen M., Taylor C. Fractal network model for simulating abdominal and lower extremity blood flow during resting and exercise conditions. Comput. Methods Biomech. Biomed. Eng. 2007;10:39–51. doi: 10.1080/10255840601068638. [DOI] [PubMed] [Google Scholar]
  26. Stergiopulos N., Young D., Rogge T. Computer simulation of arterial flow with applications to arterial and aortic stenoses. J. Biomech. 1992;25:1477–1488. doi: 10.1016/0021-9290(92)90060-e. [DOI] [PubMed] [Google Scholar]
  27. Trachet B., Reymond P., Kips J., Swillens A., Buyzere M.D., Suys B., Stergiopulos N., Segers P. Numerical validation of a new method to assess aortic pulse wave velocity from a single recording of a brachial artery waveform with an occluding cuff. Ann. Biomed. Eng. 2010;38:876–888. doi: 10.1007/s10439-010-9945-1. [DOI] [PubMed] [Google Scholar]
  28. Valdez-Jasso D., Haider M., Banks H., Santana D., German Y., Armentano R., Olufsen M. Analysis of viscoelastic wall properties in ovine arteries. IEEE Trans. Biomed. Eng. 2009;56:210–219. doi: 10.1109/TBME.2008.2003093. [DOI] [PubMed] [Google Scholar]
  29. Valdez-Jasso, D., Bia, D., Zócalo, Y., Armentano, R., Haider, M., Olufsen, M. Linear and nonlinear viscoelastic modeling of aorta and carotid pressure—area dynamics under in vivo and ex vivo conditions. Ann. Biomed. Eng., in press, doi:10.1007/s10439-010-0236-7. [DOI] [PMC free article] [PubMed]
  30. Wang J.-J., Parker K. Wave propagation in a model of the arterial circulation. J. Biomech. 2004;37:457–470. doi: 10.1016/j.jbiomech.2003.09.007. [DOI] [PubMed] [Google Scholar]
  31. Zienkiewicz O., Taylor R., Sherwin S., Peiró J. On discontinuous Galerkin methods. Int. J. Numer. Methods Eng. 2003;58:1119–1148. [Google Scholar]