Abstract
Multiwavelength detection of laser induced fluorescence for dideoxynucleotide DNA sequencing with four different fluorophores and separation by capillary gel electrophoresis is described. A cryogenically cooled, low readout noise, 2-dimensional charge-coupled device is used as a detector for the on-line, on-column recording of emission spectra. The detection system has no moving parts and provides wavelength selectivity on a single detector device. The detection limit of fluorescently labeled oligonucleotides meets the high sensitivity requirements for capillary DNA sequencing largely due to the efficient operation of the CCD detector with a 94% duty cycle. Using the condition number as a selectivity criterion, multiwavelength detection provides better analytical selectivity than detection with four bandpass filters. Monte Carlo studies and analytical estimates show that base assignment errors are reduced with peak identification based on entire emission spectra. High-speed separation of sequencing samples and the treatment of the 2-dimensional electropherogram data is presented. Comparing the DNA sequence of a sample separated by slab gel electrophoresis with sequence from capillary gel electrophoresis and multiwavelength detection we find no significant difference in the amount of error attributable to the instrumentation.
Full text
PDF







Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ansorge W., Sproat B., Stegemann J., Schwager C., Zenke M. Automated DNA sequencing: ultrasensitive detection of fluorescent bands during electrophoresis. Nucleic Acids Res. 1987 Jun 11;15(11):4593–4602. doi: 10.1093/nar/15.11.4593. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brumbaugh J. A., Middendorf L. R., Grone D. L., Ruth J. L. Continuous, on-line DNA sequencing using oligodeoxynucleotide primers with multiple fluorophores. Proc Natl Acad Sci U S A. 1988 Aug;85(15):5610–5614. doi: 10.1073/pnas.85.15.5610. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cohen A. S., Najarian D. R., Karger B. L. Separation and analysis of DNA sequence reaction products by capillary gel electrophoresis. J Chromatogr. 1990 Sep 7;516(1):49–60. doi: 10.1016/s0021-9673(01)90203-1. [DOI] [PubMed] [Google Scholar]
- Cohen A. S., Najarian D. R., Paulus A., Guttman A., Smith J. A., Karger B. L. Rapid separation and purification of oligonucleotides by high-performance capillary gel electrophoresis. Proc Natl Acad Sci U S A. 1988 Dec;85(24):9660–9663. doi: 10.1073/pnas.85.24.9660. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Drossman H., Luckey J. A., Kostichka A. J., D'Cunha J., Smith L. M. High-speed separations of DNA sequencing reactions by capillary electrophoresis. Anal Chem. 1990 May 1;62(9):900–903. doi: 10.1021/ac00208a003. [DOI] [PubMed] [Google Scholar]
- Mathies R. A., Peck K., Stryer L. Optimization of high-sensitivity fluorescence detection. Anal Chem. 1990 Sep 1;62(17):1786–1791. doi: 10.1021/ac00216a012. [DOI] [PubMed] [Google Scholar]
- Prober J. M., Trainor G. L., Dam R. J., Hobbs F. W., Robertson C. W., Zagursky R. J., Cocuzza A. J., Jensen M. A., Baumeister K. A system for rapid DNA sequencing with fluorescent chain-terminating dideoxynucleotides. Science. 1987 Oct 16;238(4825):336–341. doi: 10.1126/science.2443975. [DOI] [PubMed] [Google Scholar]
- Sweedler J. V., Shear J. B., Fishman H. A., Zare R. N., Scheller R. H. Fluorescence detection in capillary zone electrophoresis using a charge-coupled device with time-delayed integration. Anal Chem. 1991 Mar 1;63(5):496–502. doi: 10.1021/ac00005a022. [DOI] [PubMed] [Google Scholar]
- Swerdlow H., Gesteland R. Capillary gel electrophoresis for rapid, high resolution DNA sequencing. Nucleic Acids Res. 1990 Mar 25;18(6):1415–1419. doi: 10.1093/nar/18.6.1415. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wu S., Dovichi N. J. High-sensitivity fluorescence detector fluorescein isothiocyanate derivatives of amino acids separated by capillary zone electrophoresis. J Chromatogr. 1989 Oct 20;480:141–155. doi: 10.1016/s0021-9673(01)84284-9. [DOI] [PubMed] [Google Scholar]
- Zagursky R. J., McCormick R. M. DNA sequencing separations in capillary gels on a modified commercial DNA sequencing instrument. Biotechniques. 1990 Jul;9(1):74–79. [PubMed] [Google Scholar]