Abstract
Infants spend most of their indoor time at home; however, residential air quality is poorly understood. We investigated the air quality of infants’ homes in the New England area of the U.S. Participants (N = 53) were parents of infants (0–6 months) who completed telephone surveys to identify potential pollutant sources in their residence. Carbon monoxide (CO), carbon dioxide (CO2), particulate matter with aerodynamic diameter ≤0.5 µm (PM0.5), and total volatile organic compounds (TVOCs) were measured in 10 homes over 4–7 days, and levels were compared with health-based guidelines. Pollutant levels varied substantially across homes and within homes with overall levels for some homes up to 20 times higher than for other homes. Average levels were 0.85 ppm, 663.2 ppm, 18.7 µg/m3, and 1626 µg/m3 for CO, CO2, PM0.5, and TVOCs, respectively. CO2, TVOCs, and PM0.5 levels exceeded health-based indoor air quality guidelines. Survey results suggest that nursery renovations and related potential pollutant sources may be associated with differences in urbanicity, income, and presence of older children with respiratory ailments, which could potentially confound health studies. While there are no standards for indoor residential air quality, our findings suggest that additional research is needed to assess indoor pollution exposure for infants, which may be a vulnerable population.
Keywords: indoor air, infants, nurseries, carbon dioxide, carbon monoxide, volatile organic compounds, particulate matter
1. Introduction
Residential indoor air quality is not regulated, and the levels of indoor pollution are not widely known. Some sources of indoor air pollution in homes are solvents used in cleaning, building materials, paint, radon, allergens, cooking, smoking, plastics, carpets, and biomass burning for fuel or cooking [1,2,3,4,5]. Levels are affected by trends in building design and construction practices, such as reduced ventilation rates, more tightly sealed buildings, and synthetic building materials and furnishings. Solvents involved in renovations and painting in homes have been associated with increased risk of general respiratory symptoms for children under 5 years [1]. Volatile organic compounds (VOCs) are found in sources such as paints, furnishings, carpets, and household cleaning products. Many can be respiratory and sensory irritants, carcinogens, developmental toxins, neurotoxins, hepatotoxins, and immunosuppressants, and may cause symptoms that manifest as sick building syndrome [6].
Most people in the U.S. spend 90% or more of their time indoors [7]. A recent review of scientific literature on indoor air identified the study of how indoor air affects health as one of the greatest research needs [8]. The health effects of indoor air pollutants are not fully understood, but indoor air quality has been linked with a wide array of health outcomes including deficits in lung function, chronic respiratory disease, lung cancer, heart disease, developmental disorders, and damage to the brain, nervous system, liver, or kidneys [9,10,11,12]. Health consequences from indoor air can result from cumulative exposure possibly starting in infancy [13].
Children’s health outcomes have been associated with exposure to hazardous chemicals, many of which are present indoors. These health impacts include asthma, behavioral disorders, learning disabilities, autism, cancer, dysfunctional immune systems, neurological impairments and reproductive disorders [14]. A review of studies on air pollution exposure and sudden infant death syndrome (SIDS) concluded that while more research is needed, there exists suggestive evidence that air pollution affects SIDS [15,16]. The authors recommended further research on indoor air quality.
Infants are a unique and important subpopulation to study with respect to indoor air pollution for several reasons. They spend a majority of their time indoors [17]. Their exposures can deliver higher doses as infants breathe more air per body weight than adults. Their respiratory and other systems are under development. Mouth breathing, which bypasses the filter of the nose, is more common in infants than adults. Mouth breathing may pull air pollutants deeper into the respiratory system, which could result in a different composition of the pollutant mixture at the alveolar level [18]. Homes of newborn infants are of special interest because parents may consider renovation and redecoration that impacts indoor air quality, such as through indoor painting.
Little research has been conducted on infant exposures to indoor air pollution and consequent health outcomes, partially due to the lack of available monitoring data analogous to that for ambient pollution, the heterogeneity in exposures across homes, ethical considerations regarding human exposure studies for infants, and the challenges of using animal models due to the animal and human differences of gestation periods and developmental stages at birth [19]. To help address the significant gap in the scientific literature on infants’ exposure to indoor air pollution, we performed a study of indoor air pollution in homes of newborn infants in the New England area of the U.S. using monitoring data to quantify exposures and survey data to assess potential sources of exposures.
2. Experimental Section
2.1. Recruitment
Subjects were required to live in the northeastern U.S. and have an infant age 0–6 months at the time of enrollment. No other exclusion criteria were applied. Recruitment began June 2009 and continued until October 2009 and was conducted through distribution of flyers in thirteen maternity clinics, hospitals, and birthing classes throughout the northeastern U.S. Consent was obtained from the places of business where the flyers were posted. Advertisements were posted online on new mother websites and community billboards. In exchange for participation in the phone survey, each participant was offered $20 to be paid after the survey. At the conclusion of the study, all participants were offered results from the study and a brochure on indoor air quality. Subjects who participated in the air monitoring were offered the monitoring results for their home. The Yale Human Subjects Committee approved this study. The five stages of the study design were thus: recruitment; phone survey; indoor air monitoring; data analysis; and information distribution to study participants.
2.2. Indoor Air Quality Monitoring
Indoor air monitoring was conducted for carbon monoxide (CO), carbon dioxide (CO2), particulate matter with aerodynamic diameter ≤0.5 (PM0.5), total volatile organic compounds (TVOCs), temperature, and humidity. These pollutants were chosen based on previous observed health impacts and compatibility with available monitors [15,20,21,22,23,24,25,26]. Measurements were taken between June 19 and August 9, 2009 in ten homes: three homes in Connecticut, three in New York, two in Vermont, and two in Massachusetts. The air monitor was placed in the nursery approximately two feet above the floor on a horizontal surface (e.g., chair, shelf, table) away from windows and doors, and measurements were taken for 4 to 7 days in each home. For the purpose of this study, the term “nursery” is used to describe the area in the home where the infant spends the majority of his/her time, as identified by the participants.
Monitoring was conducted with an AirAdvice M7100 [20,21]. TVOCs and PM0.5 are reported in µg/m3 and CO2 and CO in ppm. This monitor does not measure other forms of PM, such as particulate matter with aerodynamic diameter ≤2.5 µm or ≤10 µm (PM2.5 or PM10). For measurements that exceeded the CO2 monitor limit of 2000 ppm, summary measures (e.g., overall average of CO2 in a home during the monitoring period) were calculated with these values as 2000 ppm, which underestimates the true pollution levels. The pollutant measurements were analyzed to determine the variability and overall levels of each pollutant within the nurseries and among the participants. Variability was assessed by summary statistics, boxplots, analysis of variance, and coefficient of variance (COV), which is the standard deviation divided by the mean ×100%, with larger values indicating higher variability in relation to the mean value.
2.3. Survey of Potential Indoor Pollutant Sources
A telephone survey of 53 study subjects was conducted to assess potential sources of residential indoor air pollution, and to investigate the degree to which the arrival of a new infant coincided with activities that may relate to indoor air pollution (e.g., indoor painting). The 10 subjects who participated in air pollution monitoring also participated in the survey, and were randomly selected. Questions elicited information on the parent characteristics (e.g., mother’s education) and household characteristics (e.g., type of heating fuel). The survey focused on aspects of the home that may impact air quality, such as renovation prior to or shortly after the infant’s arrival, air purifiers, and presence of cockroaches [27,28,29,30,31,32]. Questions pertaining to renovation refer to activities taking place in the last six months of pregnancy to the time of the survey. All surveys were conducted by a single investigator to ensure consistency.
2.4. Dissemination of Results to Participants
At the conclusion of the study, each participant was offered the results from the study for overall findings and a U.S. Environmental Protection Agency (U.S. EPA) brochure providing general information on indoor air quality [33]. Participants in the monitoring phase of the study were offered monitoring results for their own home.
3. Results and Discussion
3.1. Indoor Air Quality Monitoring Results
Monitoring for indoor air quality was conducted in the room in which the infant spends the most time for 10 homes. Table 1 summarizes the pollutant levels, temperature, and humidity in each home. Pollutant levels varied greatly across homes with overall levels for some homes up to 20 times higher than for another home (e.g., TVOCs for Participants D and E). The homes with the highest levels varied by pollutant (Participants F and I for CO, D and I for CO2, B and C for PM0.5, and D and F for TVOCs). Those with the highest overall levels were not necessarily those with the highest peak levels. For instance, Participant A’s average PM0.5 level was lower than that of most other homes (6 of 9), but had the highest hourly value.
Figure 1 provides boxplots of hourly pollutant levels for each pollutant and home, and illustrates the variability of pollutant levels within a given nursery and across homes. Ninety percent of hourly measurements were between 0.37 and 1.93 ppm for CO, 411.9 and 1194 ppm for CO2, 4.4 and 53.3 µg/m3 for PM0.5, and 124.0 and 5171 μg/m3 for TVOCs. Figure 1 also provides the COV for each pollutant and home. Participant G had the highest variability, based on the COV, for CO, CO2, and TVOCs, and the second highest variability for PM0.5. CO2 exhibited the lowest average variability in relation to the mean and PM0.5 the highest. Between participant variability was larger than within participant variability for all pollutants, based on analysis of variance (p-value <0.001). TVOC levels appeared highly variable both across the nurseries and within individual nurseries (Figure 1d), with average levels within a home ranging from 210.8 to 4683 µg/m3 and some measurements exceeding 6000 µg/m3.
Table 1.
CO [ppm] | CO2 [ppm] | PM0.5 [μg/m3] | TVOCs [μg/m3] | Temperature [°F] | Relative humidity [%] | |
---|---|---|---|---|---|---|
Participant A | 1.04, 0.92 | 603.7, 556.3 | 13.8, 6.2 | 459.6, 442.5 | 74.0, 74.1 | 64.6, 64.6 |
(0.57 to 2.78) | (419.9 to 1102) | (2.6 to 143.9) | (241.2 to 811.4) | (68.3 to 78.6) | (60.5 to 68.0) | |
Participant B | 0.71, 0.63 | 494.9, 487.4 | 25.0, 23.0 | 328.6, 285.5 | 79.3, 79.7 | 59.0, 59.6 |
(0.35 to 3.52) | (396.8 to 994.4) | (8.3 to 83.4) | (95.2 to 104.8) | (72.4 to 83.6) | (44.2 to 72.7) | |
Participant C | 0.52, 0.52 | 484.5, 450.1 | 32.2, 19.7 | 346.1, 242.9 | 80.5, 80.1 | 54.1, 57.3 |
(0.25 to 1.13) | (382.3 to 784.4) | (4.2 to 104.1) | (105.8 to 1253) | (77.2 to 83.9) | (37.0 to 69.3) | |
Participant D | 0.48, 0.47 | 934.6, 847.0 | 18.4, 13.7 | 4683, 5031 | 76.1, 76.7 | 60.8, 61.0 |
(0.30 to 0.74) | (445.2 to 1999) | 4.5 to 92.6) | (993.4 to 8321) | (72.1 to 80.0) | (49.1 to 67.0) | |
Participant E | 0.49, 0.47 | 491.5, 480.1 | 11.7, 11.0 | 210.8, 168.7 | 77.0, 77.1 | 53.4, 54.9 |
(0.34 to 0.81) | (415.3 to 709.7) | (3.9 to 45.4) | (89.2 to 1351) | (72.1 to 80.4) | (40.4 to 64.4) | |
Participant F | 1.76, 1.65 | 932.7, 935.9 | 12.6, 8.79 | 3722, 3627 | 75.4, 75.4 | 60.7, 60.0 |
(0.97 to 4.69) | (573.5 to 1638) | (3.5 to 53.6) | (2730 to 5941) | (72.6 to 76.2) | (51.2 to 68.1) | |
Participant G | 0.79, 0.59 | 745.3, 582.7 | 21.8, 15.6 | 1343, 791.8 | 74.4, 74.5 | 68.0, 67.6 |
(0.35 to 3.88) | (433.3 to >2000) | (2.0 to 95.7) | (382.8 to 6171) | (67.8 to 79.5) | (61.3 to 74.1) | |
Participant H | 0.53, 0.48 | 506.0, 523.2 | 23.6, 18.9 | 1862, 1660 | 71.3, 71.3 | 72.1, 70.9 |
(0.32 to 0.85) | (382.5 to 703.3) | (7.5 to 57.8) | (327.2 to 7363) | (68.1 to 77.5) | (65.0 to 80.0) | |
Participant I | 1.70, 1.45 | 974.1, 1011 | 19.1, 19.1 | 3020, 2635 | 72.1, 72.2 | 53.3, 52.5 |
(1.04 to 3.94) | (544.0 to 1458) | (3.94 to 43.2) | (1658 to 9168) | (69.7 to 74.4) | (47.9 to 60.6) | |
Participant J | 0.51, 0.44 | 464.2, 471.0 | 8.7, 6.7 | 287.2, 60.0 | 74.0, 74.6 | 59.8, 60.3 |
(0.30 to 2.37) | (382.1 to 671.1) | (3.2 to 46.0) | (117.4 to 858.7) | (67.8 to 79.0) | (46.9 to 71.3) | |
All participants 1 | 0.85, 0.79 | 663.2, 646.8 | 18.7, 13.8 | 1626, 1498 | 75.4, 76.0 | 60.5, 59.8 |
(0.25 to 4.69) | (382.1 to >2000) | (2.0 to 143.9) | (89.2 to 9186) | (70.8 to 79.3) | (50.4 to 69.6) |
1 The number of measurements varied by participant. Averages across all participants represent the average of each participant’s overall average. The minimum and maximum for all participants represent the lowest and highest values recorded for any participant.
We calculated Pearson’s correlations among all pollutant pairs for each home (Table 2). The highest correlations were among TVOC and CO2 although this relationship varied across homes (average correlation 0.68, range 0.42 to 0.94). Other high correlations were noted for CO and CO2 (average 0.60, range 0.06 to 0.90). Table 2 also shows the correlations between pollutant levels and weather variables. On average across the 10 homes, pollutants were not correlated with temperature or relative humidity, although one home had a correlation of 0.71 for humidity and CO2, and another of 0.81 for humidity and PM0.5.
Table 2.
CO2 | PM0.5 | TVOC | Temperature | Relative humidity | |
---|---|---|---|---|---|
CO | 0.60 | 0.20 | 0.42 | 0.08 | 0.14 |
(0.06 to 0.90) | (−0.27 to 0.48) | (−0.14 to 0.83) | (−0.19 to 0.35) | (−0.34 to 0.49) | |
CO2 | 0.11 | 0.68 | −0.02 | 0.25 | |
(−0.70 to 0.66) | (0.42 to 0.94) | (−0.49 to 0.58) | (−0.23 to 0.71) | ||
PM0.5 | 0.13 | 0.01 | 0.29 | ||
(−0.17 to 0.71) | (−0.59 to 0.39) | (−0.22 to 0.81) | |||
TVOC | 0.01 | 0.11 | |||
(−0.35 to 0.50) | (−0.35 to 0.52) | ||||
Temperature | −0.08 | ||||
(−0.65 to 0.89) |
Note: The minimum and maximum represent the smallest and largest correlations within a given home.
Results indicate that the daily pattern of exposure to indoor air pollution in nurseries also differs across homes. As an example, Figure 2 shows hourly average levels of TVOC concentrations across time in three homes. Levels in Participant D’s home averaged 4683 μg/m3 and exceeded 6000 μg/m3 at some point each day. Levels for Participant E followed a different pattern, averaging 210.8 μg/m3 and below 500 μg/m3 for most of the measurement period, then rising sharply to an hourly average >1,300 μg/m3 during the final day.
TVOCs in Participant G’s home averaged 1343 μg/m3 and varied widely with full-day (24-h) daily averages ranging from 832 to 1638 μg/m3 and hourly averages >5000 μg/m3 on two days. Supplemental Figures 1–4 provide similar graphs for all four pollutants and homes.
3.2. Comparison of Monitoring Results to Air Quality Guidelines
Indoor air quality in residences is not regulated; however for context, we compared the measured levels to several air quality guidelines and standards including health-based regulations for outdoor air, regulations for indoor air in occupational settings, and indoor air quality guidelines. Table 3 provides air quality guidelines developed by AirAdvice using information from the U.S. EPA; the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE); World Health Organization (WHO); Leadership in Environmental and Ecological Design (LEED); Indoor Air Quality Association; California Air Resources Board; Health Canada; European Union; U.K. Department of Health; state governments; and scientific experts [20,21]. Table 4 provides the air quality metrics for each pollutant based on the exposure timeframe used in Table 3 (i.e., daily average for PM0.5, CO2, and TVOCs; maximum 1-h and 8-h average for CO) for each participant and each day (Table 4). We also compared measurements to air quality guidelines developed by the Occupational Safety and Health Administration (OSHA), the American Conference of Governmental Industrial Hygienists (ACGIH), and the National Institute for Occupational Safety and Health (NIOSH) for indoor air in occupational settings. Other comparisons include guidelines from the Consumer Product Safety Commission, residential air quality guidelines from Health Canada, and U.S. EPA health-based regulations and WHO guidelines for outdoor air.
Table 3.
CO | CO2 | PM0.5 | TVOCs | Indoor Air Quality Rating |
---|---|---|---|---|
<5 ppm, 8-h average | ≤750 ppm, daily average | ≤10 μg/m3, daily average | ≤500 μg/m3, daily average | Acceptable |
5–9 ppm, 8-h average | 751–999 ppm, daily average | 11–25 μg/m3, daily average | 501–3000 μg/m3, daily average | Action recommended for sensitive groups 1 |
26–35 μg/m3, daily average | Action recommended | |||
>20 ppm, 1-h average and/or >9 ppm, 8-h average | >999 ppm, daily average | >35 μg/m3, daily average | >3000 μg/m3, daily average | Action necessary |
Table 4.
a. CO daily 1-h maximum (ppm) | ||||||||
Participant | Day 1 | Day 2 | Day 3 | Day 4 | Day 5 | Day 6 | Day 7 | Day 8 |
A | 2.0 | 1.5 | 2.8 | 0.9 | 0.9 | |||
B | 3.5 | 1.2 | 1.0 | 0.9 | 0.8 | 1.0 | 1.1 | 0.6 |
C | 0.6 | 0.6 | 0.6 | 1.1 | 0.6 | |||
D | 0.5 | 0.7 | 0.6 | 0.7 | ||||
E | 0.8 | 0.6 | 0.6 | 0.6 | 0.6 | 0.4 | ||
F | 4.7 | 2.2 | 2.0 | 2.3 | ||||
G | 0.7 | 0.8 | 2.0 | 1.5 | 3.9 | |||
H | 0.7 | 0.7 | 0.5 | 0.8 | ||||
I | 1.9 | 1.8 | 3.9 | 1.5 | ||||
J | 1.0 | 0.6 | 2.4 | 0.7 | ||||
b. CO2 daily average (ppm) | ||||||||
Participant | Day 1 | Day 2 | Day 3 | Day 4 | Day 5 | Day 6 | Day 7 | Day 8 |
A | 763 | 555 | 653 | 538 | 528 | |||
B | 511 | 519 | 487 | 481 | 482 | 497 | 483 | 483 |
C | 475 | 456 | 443 | 525 | 517 | |||
D | 872 | 1111 | 765 | 973 | ||||
E | 496 | 485 | 468 | 474 | 479 | 629 | ||
F | 1148 | 965 | 872 | 841 | ||||
G | 575 | 712 | 697 | 557 | 1238 | |||
H | 509 | 482 | 477 | 582 | ||||
I | 1040 | 1057 | 1059 | 767 | ||||
J | 469 | 444 | 467 | 492 | ||||
c. PM0.5 daily average (μg/m3) | ||||||||
Participant | Day 1 | Day 2 | Day 3 | Day 4 | Day 5 | Day 6 | Day 7 | Day 8 |
A | 5.8 | 13.1 | 20.3 | 9.1 | 21.7 | |||
B | 23.9 | 30.3 | 19.0 | 22.1 | 28.3 | 20.4 | 27.2 | 35.3 |
C | 7.2 | 9.0 | 29.7 | 57.1 | 36.6 | |||
D | 20.8 | 16.4 | 18.7 | 18.7 | ||||
E | 14.4 | 10.8 | 8.3 | 13.4 | 14.6 | 7.9 | ||
F | 8.3 | 9.1 | 16.5 | 14.7 | ||||
G | 16.4 | 15.7 | 38.9 | 16.0 | 19.3 | |||
H | 23.2 | 37.2 | 17.3 | 13.1 | ||||
I | 11.2 | 15.5 | 18.5 | 25.9 | ||||
J | 14.7 | 7.8 | 7.1 | 6.4 | ||||
d. TVOC daily average (μg/m3) | ||||||||
Participant | Day 1 | Day 2 | Day 3 | Day 4 | Day 5 | Day 6 | Day 7 | Day 8 |
A | 771 | 520 | 811 | 749 | 570 | |||
B | 1000 | 933 | 584 | 512 | 1042 | 644 | 463 | 348 |
C | 265 | 514 | 509 | 937 | 1253 | |||
D | 6919 | 8321 | 7048 | 6953 | ||||
E | 360 | 593 | 586 | 504 | 428 | 1351 | ||
F | 4270 | 5148 | 5941 | 3753 | ||||
G | 1148 | 2843 | 6171 | 1688 | 5148 | |||
H | 678 | 3042 | 2390 | 7363 | ||||
I | 2009 | 9186 | 4613 | 3095 | ||||
J | 483 | 476 | 363 | 859 |
Each day is color coded corresponding to the indoor air quality guidelines from Table 3.
The daily maximum 1-h CO level for each day and nursery are provided in Table 4a. CO levels for all nurseries met the guidelines in Table 3 with all hourly values <20 ppm and 8-hour values <5 ppm. Measurements of CO met the Consumer Product Safety Commission recommended maximum levels of 15 ppm for 1 h and 25 ppm for 8 h, and the Health Canada recommendations for residential air quality at 25 ppm for 1 h and 10 ppm for 24 h [34]. The measured levels also were well within standards and guidelines for occupational settings: the OSHA permissible exposure limit (PEL) for general industry of 50 ppm for an 8-h exposure [35], the NIOSH recommended exposure limit (REL) of 35 ppm 8-h average based on cardiovascular response [36], and ACGIH threshold limit value of 25 ppm 8-h average based on risk of elevated carboxyhemoglobin levels [37]. Measured CO was below EPA’s National Ambient Air Quality Standards of 9 ppm for 8 h and 35 ppm for 1 h [38] and the WHO’s guidelines for ambient air for 10 ppm for 8-h and 25 ppm for 1 h [39].
Table 4b compares daily CO2 levels for a given nursery to air quality guidelines. For four nurseries at least one daily CO2 level exceeded the guideline for action needed, >999 ppm as per Table 3, and for one of these homes, that level was reached three out of four days measured. An additional household had one daily average at a level for recommended action for sensitive individuals. For four of the homes, CO2 levels exceeded ASHRAE recommendations that indoor levels be ≤1000 ppm for schools and ≤800 ppm for offices [40]. Recommendations for occupational settings are much higher at NIOSH guidelines of 5000 ppm for an 8-h exposure and 30,000 ppm for any 10-min period, OSHA PEL of 5000 ppm for an 8-h period [35]. Levels were also well below ACGIH guidelines of 5000 ppm for an 8-h exposure and 30,000 ppm for a short-term exposure limit [41]. Based on AirAdvice criteria, all homes had PM0.5 and TVOC levels above the threshold for action recommended for sensitive groups (Table 4c,d). The levels for action necessary were exceeded by three homes for PM0.5 and half of the homes for TVOCs.
3.3. Survey Results
Supplemental Table 1 describes the participants in the telephone survey (N = 53). Most respondents were mothers, with average age of 31.3 years (range 19–43 years) and infants with an average age of 97 days (range 6–192 days). No participants were pregnant at the time of the survey. Participants were predominately white (85%). The subjects’ educational levels were high with all mothers having completed at least one year of college, and almost 19% with 20 or more years of school. More than 79% of participant households had annual incomes exceeding $50,000. Of the 25% of homes with older siblings, 15% of those siblings had asthma and 38% had allergies. The infants spent most of their time in the home, with 9.4% in daycare (average 36 h/week).
Table 5 describes housing characteristics for the study participants. Most houses were older (average year built was around the early 1940s, range 1810–2005). The most common home heating sources were oil, gas, and electric, with only 5.7% for wood, and some homes having multiple heating sources. Other potential sources of indoor air pollution identified by 20% or more of participants were fireplaces (21%), gas stoves (62%), attached garage (28%), mice (32%), and indoor pesticides (21%). Of the 51% with pets, 44% had cats and 63% had dogs. Aromatic candles were in the nursery for 15.1% of the nurseries. Of the candle users, 38% kept the candles unlit. Smoking took place in 3.8% of the homes. Survey participants estimated the distance between the home and the nearest road at an average of 63 feet, with 53% less than 25 feet away.
Table 5.
Number of participants (%) | |||
---|---|---|---|
All participants (N = 53) | Monitoring participants (n = 10) | Non-monitoring participants (n = 43) | |
Neighborhood environment | |||
Urban | 26 (49.1%) | 6 (60%) | 20 (46.5%) |
Suburban | 18 (34.0%) | 3 (30%) | 6 (14.0%) |
Rural | 9 (17.0%) | 1 (10%) | 17 (39.5%) |
Home structure | |||
Single-family detached dwelling | 19 (35.8%) | 4 (40%) | 15 (34.9%) |
Townhouse or duplex | 12 (22.6%) | 1 (10%) | 11 (25.6%) |
Multiple story apartment building | 22 (41.5%) | 5 (50%) | 17 (39.5%) |
Year home built | |||
<1900 | 8 (15.1%) | 1 (10.0%) | 7 (16.3%) |
1900–1949 | 19 (35.8%) | 1 (10.0%) | 18 (41.9%) |
1950–2000 | 24 (45.3%) | 7 (70.0%) | 17 (39.5%) |
>2000 | 2 (3.8%) | 1 (10.0%) | 1 (2.3%) |
Distance to roadway (feet) | |||
<10 | 9 (17.0%) | 2 (20.0%) | 7 (16.3%) |
10–25 | 19 (35.8%) | 3 (30.0%) | 16 (37.2%) |
26–50 | 13 (24.5%) | 1 (10.0%) | 12 (27.9%) |
51–200 | 9 (17.0%) | 3 (30.0%) | 6 (14.0%) |
>200 | 3 (5.7%) | 1 (10.0%) | 2 (4.7%) |
Heating source (homes may have multiple sources) | |||
Oil | 16 (30.2%) | 2 (20.0%) | 14 (32.6%) |
Gas | 22 (41.5%) | 5 (50.0%) | 17 (39.5%) |
Electric | 13 (24.5%) | 2 (20.0%) | 11 (25.6%) |
Wood | 3 (5.7%) | 4 (5.7%) | 2 (4.7%) |
Unknown | 1 (1.9%) | 0 (0%) | 1 (2.3%) |
Stove type | |||
Electric | 19 (35.8%) | 3 (30.0%) | 16 (37.2%) |
Gas | 33 (62.3%) | 7 (70.0%) | 26 (60.5%) |
Propane | 1 (1.9%) | 0 (0.0%) | 1 (2.3%) |
Presence in home | |||
Smoker living in home | 2 (2.3%) | 0 (10.0%) | 2 (4.7%) |
Smoking in home | 2 (3.8%) | 1 (10.0%) | 1 (2.3%) |
Fireplace (used) | 11 (20.8%) | 2 (20.0%) | 9 (20.9%) |
Attached garage | 15 (28.3%) | 5 (50.0%) | 10 (23.3%) |
Cockroaches | 4 (7.5%) | 1 (10.0%) | 3 (7.0%) |
Mice | 17 (32.1%) | 3 (30.0%) | 14 (32.6%) |
Pesticides | 11 (20.8%) | 1 (10.0%) | 10 (23.3%) |
Pets (any) | 27 (50.9%) | 5 (50.0%) | 22 (51.2%) |
Cats | 12 (22.6%) | 4 (40.0%) | 8 (18.6%) |
Dogs | 17 (32.1%) | 1 (10.0%) | 16 (37.2%) |
Plants | 35 (66.0%) | 8 (80.0%) | 27 (62.8%) |
Presence in nursery | |||
Room deodorizers | 4 (7.5%) | 1 (10.0%) | 3 (7.0%) |
Air purifiers | 7 (13.2%) | 1 (10.0%) | 6 (14.0%) |
Aromatic candles (lit) | 5 (9.4%) | 0 (0%) | 2 (4.7%) |
Aromatic candles (unlit) | 3 (5.7%) | 0 (0.0%) | 6 (14.0%) |
Table 6 describes renovation characteristics for the study participants. Of the 53 participants, 66% had remodeled the nursery at some point during the last six months of pregnancy to the time of the survey, with fewer (42%) having remodeled another portion of the house. Of those that remodeled the nursery, 11% of participants responded that renovations were complete before the infant’s arrival, on average 52 days prior to birth (range 24–92 days). Painting had taken place in the nursery for 49% of the participants, with interior walls painted more often than furniture, floor, or trim. Of those who painted, 46% reported using low-VOC paint. Area rugs were added to 28% of nurseries, 73% of which were new. Those who renovated the nursery did not differ from those who did not by mother’s demographics (age, race, or education) or the age of the home age. Similarly, those who painted the nursery and those who did not were similar on these factors (results not shown).
Table 6.
Number of participants (%) | |||
---|---|---|---|
All participants (N = 53) | Monitoring participants (n = 10) | Non-monitoring participants (n = 43) | |
Remodeled nursery | 35 (66.0%) | 8 (80.0%) | 27 (62.8%) |
Remodeled another part of house | 22 (41.5%) | 5 (50.0%) | 17 (39.5%) |
Renovations complete before birth | 4 (7.5%) | 4 (40.0%) | 0 (0.0%) |
Painting in nursery | 26 (49.1%) | 4 (40.0%) | 22 (51.2%) |
Interior walls | 13 (24.5%) | 4 (40.0%) | 9 (20.9%) |
Furniture | 3 (5.7%) | 0 (0.0%) | 3 (7.0%) |
Floor | 1 (1.9%) | 0 (0.0%) | 1 (2.3%) |
Trim | 4 (7.5%) | 1 (10.0%) | 2 (7.0%) |
Low VOC paint | 12 (22.6%) | 3 (30.0%) | 9 (20.9%) |
Wallpaper | 7 (13.2%) | 2 (20.0%) | 5 (11.6%) |
Decals | 2 (3.8%) | 0 (0.0%) | 2 (4.7%) |
Used area rug | 4 (7.5%) | 1 (10.0%) | 3 (7.0%) |
New area rug | 11 (20.8%) | 2 (20.0%) | 9 (20.9%) |
Carpet | 4 (7.5%) | 1 (10.0%) | 3 (7.0%) |
Several general trends were observed in the survey data, although differences are not statistically significant and sample size is limited. Those in rural environments were more likely to renovate (89%) or paint (78%) the nursery than those in urban environments (6.7% renovated, 44% painted). Of those with household annual income <$40,000, 71% renovated the nursery and 75% lived in rural environments, compared to 55% and 0% of those with annual income >$100,000, respectively. A similar fraction of those with income <$40,000 painted the nursery (57%) as those with incomes >$100,000 (50%); however, painters in the lower income group were more likely to select low-VOC paint (75%) than painters in the higher income group (40%). Those with older children with asthma or allergies were less likely to have potential indoor air pollution sources than those without older children with these health concerns for: wallpaper installation in the nursery (0% vs. 15%), painting of the nursery (40% vs. 50%), use of indoor pesticides (0% vs. 23%), smoking in the home (0% vs. 4.2%), and room deodorizers in the nursery (0% vs. 8.3%). Those with older children with asthma or allergies were more likely to have air purifiers in the nursery (20% vs. 13%) and less likely to have pets (40% vs. 52%).
4. Conclusions
The main goal of this research is to expand the scientific literature on indoor air pollution, with a focus on infants’ exposure and source identification in the home. Little research has been conducted on residential indoor air environments for infants compared to the literature on ambient air, occupational indoor exposure, or other studies of exposure in other age groups. To date, most studies of infants and air pollution have been based on ambient pollution, with links to apnea and bradycardia [42] and infant mortality [43,44,45]. Several studies have investigated indoor air in homes for children. For example, Hulin et al. measured NO2, PM2.5, and VOCS in urban and rural homes in France for 51 children (mean age 12.6 years), finding associations with asthma and VOCs [46]. In Taiwan, the presence of mold in homes of children ages 4–7 years was not associated with biomarkers of allergic response [47]. Researchers have investigated air in other settings for children, including childcare centers. These studies include measures of phenols in North Carolina and Ohio [48]; radon, lead, asbestos, and mold in New York State [49]; CO2 in a Midwestern county in the U.S. [50]; and ozone in Singapore [51].
Studies have examined infants’ health in relation to indoor air pollution from biomass burning in India [52], Kenya [53], and Gambia [54]. One of the few studies to examine infants’ exposure in to indoor air pollution in homes in an industrialized country measured long-term exposure to NOx, NO2, formaldehyde, PM2.5, and black smoke in homes of 411 infants in Denmark, finding no association with risk of wheezing [55]. Raaschou-Nielsen et al. measured PM2.5 and black smoke in homes of 389 infants in Denmark, identifying a variety of sources, such as frying without a range hood, smoking, renovation, and local traffic [56]. Exposure to indoor pollutants of allergens (e.g., dust mite, cat, dog) and mold have been examined in relation to respiratory symptoms in infants [57,58]. A recent study of infants’ homes in Syracuse, New York, U.S., found that levels of PM10 and PM2.5 varied substantially across homes and within homes [59], which is consistent with our results. Higher levels of indoor PM2.5 was associated with infant wheeze. In that study, 68% of participants were smokers, compared to 2.3% of homes with smokers in our study [59].
The survey results show that in this limited sample, main sources of indoor pollutants may include renovation, which was conducted prior to or shortly after the infant’s arrival in 66.0% of homes. The potential factors affecting indoor air quality that were present in more than half the homes surveyed are gas stoves, pets, and remodeling of the nursery. General trends in survey results suggest that some populations may be more likely to conduct renovations of the nursery than others, potentially introducing sources of indoor air pollution such as through painting. This result indicates the potential for confounding if those populations (e.g., socio-economic conditions, urbanicity, existing health conditions in the family) are associated with the outcomes of interest in studies of infants’ health.
The limited sample size and narrow variation in participants’ demographics limit the generalizability of this study, as the population is mostly non-Hispanic white, highly educated, and high income. Participants who responded to the recruitment advertisements may have been drawn to volunteer for this study because they previously were interested in environmental issues and therefore may have taken more precautions to limit air pollution in their homes. Future efforts are needed with larger sample sizes to permit study of pollutant levels in relation to various household activities and characteristics, as well as different populations. For instance, our study population had a low reported rate of smoking in the home (3.8%), although environmental tobacco smoke is associated with a range of health outcomes for infants, such as low birth weight [60,61,62].
Research is needed to assess infants’ exposure to a more comprehensive set of indoor air pollutant measurements, such as biological contaminants including mold, dust mites, pet dander, pollen, dust, environmental tobacco smoke, other size fractions of particles (PM2.5, PM10), specific VOCs, dust, and radon. Data on home activities that could relate to indoor air quality could include detailed information on cooking, smoking, and cleaning. Future work could incorporate the penetration of ambient air pollution into the indoor environment, including differences by season, and information such as information on proximity to various types of roadways. Additional efforts are needed to better understand infants’ exposure to various pollutants in the indoor environment, including techniques to estimate levels with limited monitoring. For example, a microenvironment approach was developed for assessing infants’ exposure to indoor air pollution for respirable suspended particles and CO based on mobility patterns of infants and mothers [63]. Our findings indicate heterogeneity both within and across homes, suggesting the need for individual-level exposure assessments considering a wide range of settings, including different seasons, regions, demographics, and time-activity information that may affect pollutant levels (e.g., cooking, cleaning, opening windows). The time-activity data are particularly important to help understand the variation and large peaks that occur in pollutant concentrations throughout the day.
This study provides individual-level data that is illustrative of the ranges of pollutant levels that can be found in nurseries, with variation across homes and throughout the day within a single home. Although indoor air quality is not regulated, we observed levels of CO2, VOCs, and PM0.5 that exceeded health-based guidelines, indicating that residential air pollution may pose a health risk for infants. Given the limited sample size of this study, linking these exposure measurements to health outcomes is not appropriate. However, these results provide some of the first measurements of indoor air quality in homes of infants, and are valuable given the paucity of existing data. Understanding exposure assessment can be one of the first steps toward understanding how those exposures affect infants’ health.
Acknowledgments
This work was supported by the Jubitz Family Foundation and the Carpenter Sperry Fund. We thank AirAdvice for air monitoring equipment and technical support. We thank the U.S. EPA for providing brochures with general information on indoor air quality.
Supplementary Files
Conflict of Interest
The authors declare no conflict of interest.
References
- 1.Ballester F., Fuentes-Leonarte V., Tenías J.M. Sources of indoor air pollution and respiratory health in preschool children. J. Environ. Public Health. 2009;2009:727516:1–727516:19. doi: 10.1155/2009/727516. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Brown T., Holmes P., Harrison P.T.C. Review: The applicability of epidemiological methods to the assessment of the risks to human health of indoor air pollution: An overview. Indoor Built Environ. 2010;19:311–326. [Google Scholar]
- 3.Kaplan C. Indoor air pollution from unprocessed solid fuels in developing countries. Rev. Environ. Health. 2010;25:221–242. doi: 10.1515/reveh.2010.25.3.221. [DOI] [PubMed] [Google Scholar]
- 4.Roberts J.W., Dickey P. Exposure of children to pollutants in house dust and indoor air. Rev. Environ. Contam. Toxicol. 1995;143:59–78. doi: 10.1007/978-1-4612-2542-3_3. [DOI] [PubMed] [Google Scholar]
- 5.Zhang J., Smith K.R. Indoor air pollution: A global health concern. Br. Med. Bull. 2003;68:209–225. doi: 10.1093/bmb/ldg029. [DOI] [PubMed] [Google Scholar]
- 6.Prazad P., Cortes D.R., Puppala B.L., Donovan R., Kumar S., Gulati A. Airborne concentrations of volatile organic compounds in neonatal incubators. J. Perinatol. 2008;28:534–540. doi: 10.1038/jp.2008.75. [DOI] [PubMed] [Google Scholar]
- 7.United State Environmental Protection Agency (U.S. EPA) The Inside Story: A Guide to Indoor Air Quality. U.S. EPA Office of Air and Radiation, & Consumer Product Safety Commission; Washington, DC, USA: 1995. Report No. 402-K-93-007. [Google Scholar]
- 8.Weschler C.J. Chemistry in indoor environments: 20 years of research. Indoor Air. 2011;21:205–218. doi: 10.1111/j.1600-0668.2011.00713.x. [DOI] [PubMed] [Google Scholar]
- 9.Grandjean P., Landrigan P.J. Developmental neurotoxicity of industrial chemicals. Lancet. 2006;368:2167–2178. doi: 10.1016/S0140-6736(06)69665-7. [DOI] [PubMed] [Google Scholar]
- 10.Landrigan P.J., Kimmel C.A., Correa A., Eskenazi B. Children’s health and the environment: Public health issues and challenges for risk assessment. Environ. Health Perspect. 2004;112:257–265. doi: 10.1289/ehp.6115. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Perera F.P. Children are likely to suffer most from our fossil fuel addiction. Environ. Health Perspect. 2008;116:987–990. doi: 10.1289/ehp.11173. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Wang L., Pinkerton K.E. Air pollutant effects on fetal and early postnatal development. Birth Defects Res. Part C, Embryo Today: Rev. 2007;81:144–154. doi: 10.1002/bdrc.20097. [DOI] [PubMed] [Google Scholar]
- 13.Trasande L., Boscarino J., Graber N., Falk R., Schechter C., Galvez M., Dunkel G., Geslani J., Moline J., Kaplan-Liss E., et al. The environment in pediatric practice: A study of New York pediatricians’ attitudes, beliefs, and practices towards children’s environmental health. J. Urban Health. 2006;83:760–772. doi: 10.1007/s11524-006-9071-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Lloyd-Smith M., Sheffield-Brotherton B. Children’s environmental health: Intergenerational equity in action—a civil society perspective. Ann. NY Acad. Sci. 2008;1140:190–200. doi: 10.1196/annals.1454.051. [DOI] [PubMed] [Google Scholar]
- 15.Klonoff-Cohen H., Lam P.K., Lewis A. Outdoor carbon monoxide, nitrogen dioxide, and sudden infant death syndrome. Arch. Dis. Child. 2005;90:750–753. doi: 10.1136/adc.2004.057091. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Tong S., Colditz P. Air pollution and sudden infant death syndrome: a literature review. Paediatr. Perinat. Epidmiol. 2004;18:327–335. doi: 10.1111/j.1365-3016.2004.00565.x. [DOI] [PubMed] [Google Scholar]
- 17.Jones J., Stick S., Dingle P., Franklin P. Spatial variability of particulates in homes: Implications for infant exposure. Sci. Total Environ. 2007;376:317–323. doi: 10.1016/j.scitotenv.2007.01.060. [DOI] [PubMed] [Google Scholar]
- 18.Bateson T.F., Schwartz J. Children’s response to air pollutants. J. Toxicol. Environ. Health, Part A. 2008;71:238–243. doi: 10.1080/15287390701598234. [DOI] [PubMed] [Google Scholar]
- 19.Mitchell B.F., Tarragt M.J. Are animal models relevant to key aspects of human parturition? Am. J. Physiol. 2009;300:R525–R545. doi: 10.1152/ajpregu.00153.2009. [DOI] [PubMed] [Google Scholar]
- 20.AirAdivce. Building Advice: Advancing Building Performance, Owner’s Manual. AirAdvice; Portland, OR, USA: 2010. [Google Scholar]
- 21.AirAdvice. Model 7100 IEQ Monitor Specification & Sensor Descriptions. AirAdvice; Portland, OR, USA: 2010. [Google Scholar]
- 22.Bell M.L., Peng R.D., Dominici F., Samet J.M. Emergency hospital admissions for cardiovascular diseases and ambient levels ofcarbon monoxide: Results for 126 United States urban counties, 1999–2005. Circulation. 2009;120:949–955. doi: 10.1161/CIRCULATIONAHA.109.851113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Dashdendev B., Fukushima L.K., Woo M.S., Ganbaatar E., Warburton D. Carbon monoxidepollution and lung function in urban compared with rural Mongolian children. Respirology. 2011;16:653–658. doi: 10.1111/j.1440-1843.2011.01958.x. [DOI] [PubMed] [Google Scholar]
- 24.Pope C.A., III, Dockery D.W. Health effects of fine particulate air pollution: Lines that connect. J. Air Waste Manag. Assoc. 2006;56:709–742. doi: 10.1080/10473289.2006.10464485. [DOI] [PubMed] [Google Scholar]
- 25.Rumchev K., Spickett J., Bulsara M., Phillips M., Stick S. Association of domestic exposure to volatile organic compounds with asthma in young children. Thorax. 2004;59:746–751. doi: 10.1136/thx.2003.013680. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Wolkoff P. Trends in Europe to reduce the indoor air pollution of VOCs. Indoor Air. 2003;13:5–11. doi: 10.1034/j.1600-0668.13.s.6.1.x. [DOI] [PubMed] [Google Scholar]
- 27.Chew G.L., Correa J.C., Perzanowski M.S. Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools. Indoor Air. 2005;15(Suppl. 6):228–234. doi: 10.1111/j.1600-0668.2005.00363.x. [DOI] [PubMed] [Google Scholar]
- 28.Esposito W.A., Chew G.L., Correa J.C., Chillrud S.N., Miller R.L., Kinney P.L. Quantitative measurement of airborne cockroach allergen in New York City apartments. Indoor Air. 2011;21:512–520. doi: 10.1111/j.1600-0668.2011.00728.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Moriske H.J., Drews M., Ebert G., Menk G., Scheller C., Schöndube M., Konieczny L. Indoor air pollution by different heating systems: Coal burning, open fireplaceand central heating. Toxicol. Lett. 1996;88:349–354. doi: 10.1016/0378-4274(96)03760-5. [DOI] [PubMed] [Google Scholar]
- 30.Raaschou-Nielsen O., Sørensen M., Hertel O., Chawes B.L.K., Vissing N., Bønnelykke K., Bisgaard H. Predictors of indoor fine particulate matter in infants’ bedrooms in Denmark. Environ. Res. 2011;111:87–93. doi: 10.1016/j.envres.2010.10.007. [DOI] [PubMed] [Google Scholar]
- 31.Silva G.V., Vasconcelos M.T.S.D., Santos A.M., Fernandes E.O. Comparison of the substrate effect on VOC emissions from water based varnish and latex paint. Environ. Sci. Pollut. Res. 2003;10:209–216. doi: 10.1065/espr2002.12.144. [DOI] [PubMed] [Google Scholar]
- 32.Song J.E., Kim Y.S., Sohn J.Y. The impact of plants on the reduction of volatile organic compounds in a small space. J. Physiol. Anthropol. 2007;26:599–603. doi: 10.2114/jpa2.26.599. [DOI] [PubMed] [Google Scholar]
- 33.United State Environmental Protection Agency (U.S. EPA) Care for Your Air: A Guide to Indoor Air Quality. U.S. EPA; Washington, DC, USA: 2008. EPA402/F-08/008. [Google Scholar]
- 34.Health Canada. Residential Indoor Air Quality Guidelines: Carbon Monoxide. Health Canada; Ottawa, Canada: 2010. Cat.: H128-1/10-603E. [Google Scholar]
- 35.Occupational Safety and Health Administration (OSHA) Occupational Safety and Health Standards, Toxic and Hazardous Substances. OSHA; Washington, DC, USA: 1999. 29 CFR Table Z-1. [Google Scholar]
- 36.National Institute for Occupational Safety and Health (NIOSH) Recommendations for Occupational Safety and Health: Compendium of Policy Documents and Statements. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, NIOSH; Cincinnati, OH, USA: 1992. DHHS (NIOSH) Publication No. 92-100. [Google Scholar]
- 37.American Conference of Governmental Industrial Hygienists (ACGIH) ACGIH; Cincinnati, OH, USA: 1994. Threshold Limit Values for Chemical Substances and Physicalagents and Biological Exposure Indices for 1994-1995. [Google Scholar]
- 38.United State Environmental Protection Agency (U.S. EPA) Air Quality Criteria for Carbon Monoxide. U.S. EPA Office of Research and Development; Washington, DC, USA: 2000. EPA 600/P-99/001F. [Google Scholar]
- 39.World Health Organization (WHO) Air Quality Guidelines for Europe; WHO Regional Publications, European Series, No. 91. WHO; Copenhagen, Denmark: 2000. [PubMed] [Google Scholar]
- 40.American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) Ventilation for Acceptable Indoor Air Quality. ASHRAE; Atlanta, GA, USA: 1989. ANSI/ASHRAE 62-1989. [Google Scholar]
- 41.American Conference of Governmental Industrial Hygienists (ACGIH) The Threshold Limit Values (TLVs) and Biological Exposure Indices (BEIs) ACGIH; Cincinnati, OH, USA: 1999. [Google Scholar]
- 42.Peel J.L., Kelin M., Flanders W.D., Mulholland J.A., Freed G., Tolbert P.E. Ambient air pollution and apnea and bradycardia in high-risk infants on home monitors. Environ. Health Perspect. 2011;119:1321–1327. doi: 10.1289/ehp.1002739. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Kaiser R., Romieu I., Medina S., Schwartz J., Krzyzanowski M., Kunzli N. Air pollution attributable postneonatal infant mortality in U.S. metropolitan areas: A risk assessment study. Environ. Health. 2004;3 doi: 10.1186/1476-069X-3-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Son J.Y., Bell M.L., Lee J.T. Survival analysis of long-term exposure to different sizes of airborne particulate matter and risk of infant mortality using a birth cohort in Seoul, Korea. Environ. Health Perspect. 2011;119:725–730. doi: 10.1289/ehp.1002364. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Woodruff T.J., Darrow L.A., Parker J.D. Air pollution and postneonatal infant mortality in the United States, 1999–2002. Environ. Health Perspect. 2008;116:110–115. doi: 10.1289/ehp.10370. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Hulin M., Caillaud D., Annesi-Maesano I. Indoor air pollution and childhood asthma: Variations between urban and rural areas. Indoor Air. 2010;20:502–514. doi: 10.1111/j.1600-0668.2010.00673.x. [DOI] [PubMed] [Google Scholar]
- 47.Hsu N.Y., Wang J.Y., Su H.J. A dose-dependent relationship between the severity of visible mold growth and IgE levels of pre-school-aged resident children in Taiwan. Indoor Air. 2010;20:392–398. doi: 10.1111/j.1600-0668.2010.00663.x. [DOI] [PubMed] [Google Scholar]
- 48.Wilson N.K., Chuang J.C., Morgan M.K., Lordo R.A., Sheldon L.S. An observational study of the potential exposures of preschool children to pentachlorophenol, bisphenol-A, and nonylphenol at home and daycare. Environ. Res. 2007;103:9–20. doi: 10.1016/j.envres.2006.04.006. [DOI] [PubMed] [Google Scholar]
- 49.Laquatra J., Maxwell L.E., Pierce M. Indoor air pollutants: Limited-resource households and child care facilities. J. Environ. Health. 2005;67:39–43. [PubMed] [Google Scholar]
- 50.Ferng S.F., Lee L.W. Indoor air quality assessment of daycare facilities with carbon dioxide, temperature, and humidity as indicators. J. Environ. Health. 2002;63:14–18. [PubMed] [Google Scholar]
- 51.Karthikeyan S., Perumal S.V., Balasubramanian R., Zuraimi M.S., Tham K.W. Determination of ozone in outdoor and indoor environments using nitrate-impregnated passive samplers followed by ion chromatography. J. Air Waste Manage. Assoc. 2007;57:974–980. doi: 10.3155/1047-3289.57.8.974. [DOI] [PubMed] [Google Scholar]
- 52.Tielsch J.M., Katz J., Thulasiraj R.D., Coles C.L., Sheeladevi S., Yanik E.L., Rahmathullah L. Exposure to indoor biomass fuel and tobacco smoke and risk of adverse reproductive outcomes, mortality, respiratory morbidity and growth among newborn infants in south India. Int. J. Epidemiol. 2009;38:1351–1363. doi: 10.1093/ije/dyp286. [DOI] [PubMed] [Google Scholar]
- 53.Ezzati M., Kammen D.M. Indoor air pollution from biomass combustion and acute respitaory infections in Kenya: An exposure-response study. Lancet. 2001;358:619–624. doi: 10.1016/s0140-6736(01)05777-4. [DOI] [PubMed] [Google Scholar]
- 54.Dionisio K.L., Howie S., Fornace K.M., Chimah O., Adegbola R.A., Ezzati M. Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia. Indoor Air. 2008;18:317–327. doi: 10.1111/j.1600-0668.2008.00533.x. [DOI] [PubMed] [Google Scholar]
- 55.Raaschou-Nielsen O., Hermansen M.N., Loland L., Buchvald F., Pipper C.B., Sørensen M., Loft S., Bisgaard H. Long-term exposure to indoor air pollution and wheezing symptoms in infants. Indoor Air. 2010;20:159–167. doi: 10.1111/j.1600-0668.2009.00635.x. [DOI] [PubMed] [Google Scholar]
- 56.Raaschou-Nielsen O., Sørensen M., Hertel O., Chawes B.L., Vissing N., Bønnelykke K., Bisgaard H. Predictors of indoor fine particulate matter in infants’ bedrooms in Denmark. Environ. Res. 2011;111:87–93. doi: 10.1016/j.envres.2010.10.007. [DOI] [PubMed] [Google Scholar]
- 57.Belanger K., Beckett W., Triche E., Bracken M.B., Holford T., Ren P., McSharry J.-E., Gold D.R., Platts-Mills T.A.E., Leaderer B.P. Symptoms of wheeze and persistent cough in the first year of life: Associations with indoor allergens, air contaminants, and maternal history of asthma. Am. J. Epidemiol. 2003;158:195–202. doi: 10.1093/aje/kwg148. [DOI] [PubMed] [Google Scholar]
- 58.Leaderer B.P., Belanger K., Triche E., Holford T., Gold D.R., Kim Y., Jankun T., Ren P., McSharry J.-E., Platts-Mills T.A.E., et al. Dust mite, cockroach, cat, and dog allergen concentrations in homes of asthmatic children in the northeastern United States: Impact of socioeconomic factors and population density. Environ. Health Perspect. 2002;110:419–425. doi: 10.1289/ehp.02110419. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Hunt A., Crawford J.A., Rosenbaum P.F., Abraham J.L. Levels of household particulate matter and environmental tobacco smoke exposure in the first year of life for a cohort at risk for asthma in urban Syracuse, NY. Environ. Int. 2011;37:1196–1205. doi: 10.1016/j.envint.2011.04.013. [DOI] [PubMed] [Google Scholar]
- 60.Jedrychowski W., Perera F., Maugeri U., Mrozek-Budzyn D., Miller R.L., Flak E., Mroz E., Jacek R., Spengler J.D. Effects of prenatal and perinatal exposure to fine air pollutants and maternal fish consumption on the occurrence of infantile eczema. Int. Arch. Allergy Immunol. 2011;155:275–281. doi: 10.1159/000320376. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Pogodina C., Brunner Huber L.R., Racine E.F., Platonova E. Smoke-free homes for smoke-free babies: The role of residential environmental tobacco smoke on low birth weight. J. Community Health. 2009;34:376–382. doi: 10.1007/s10900-009-9169-1. [DOI] [PubMed] [Google Scholar]
- 62.Salmasi G., Grady R., Jones J., McDonald S.D., Knowledge Synthesis Group Environmental tobacco smoke exposure and perinatal outcomes: A systematic review and meta-analyses. Acta Obstet. Gynecol. Scand. 2010;89:423–441. doi: 10.3109/00016340903505748. [DOI] [PubMed] [Google Scholar]
- 63.Anderson M.E., Bogdan G.M. Environments, indoor air quality, and children. Pediatr. Clin. N. Am. 2007;54:295–307. doi: 10.1016/j.pcl.2007.01.003. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.