Abstract
Cerebral 3D time of flight (TOF) angiography significantly benefits from ultra high fields, mainly due to higher SNR and to longer T1 relaxation time of static brain tissues, however, SAR significantly increases with B0. Thus, additional RF pulses commonly used at lower field strengths to improve TOF contrast such as saturation of venous signal and improved background suppression by magnetization transfer typically cannot be used at higher fields. In this work we aimed at reducing SAR for each RF pulse category in a TOF sequence. We use the VERSE principle for the slab selective TOF excitation as well as the venous saturation RF pulses. Additionally, MT pulses are implemented by sparsely applying the pulses only during acquisition of the central k-space lines to limit their SAR contribution. Image quality, angiographic contrast and SAR reduction were investigated as a function of VERSE parameters and of the total number of MT pulses applied. Based on these results, a TOF protocol was generated that increases the angiographic contrast by more than 50% and reduces subcutaneous fat signal while keeping the resulting SAR within regulatory limits.
Keywords: time of flight, SAR, RF power, VERSE, MR angiography, ultra-high field MRI
Introduction
Time of flight (TOF) imaging is the most commonly used non-contrast enhanced MR angiography technique (1). In 3D TOF MR angiography a slab selective 3D steady state gradient echo sequence with a TR much shorter than the T1 relaxation time of static tissue is used. A sufficiently large flip angle, typically 20°–40° (2), is applied to suppress MR signals of static tissue, whereas fully relaxed inflowing blood entering the excitation slab provides strong MR signal, resulting in a positive vessel contrast suitable for maximum intensity projection (MIP) reconstruction. TOF angiography has been shown to substantially benefit from high magnetic field of 7T, because of increased signal-to-noise ratio (SNR) (3) and longer T1 relaxation times (4). However, for a given flip angle the specific absorption rate (SAR) of an RF pulse increases with B0 (5), which may preclude the use at 7T of lower field protocol parameters.
Clinical TOF protocols at B0 ≤ 3T already apply relatively high average RF power levels for several reasons. First, a short TR is used in combination with a relatively high flip angle. Second, the background signal suppression is routinely improved with Magnetization Transfer (MT) preparation pulses (2,6,7) that require high RF power. Third, to selectively image the intracranial arteries while reducing venous contributions, RF power-intensive spatial saturation pulses are used to saturate e.g. venous signal in the sagittal sinus. Because of these SAR constraints, TOF angiograms at 7T (8–13) were often obtained with suboptimal TR or excitation flip angle, and with venous saturation and MT pulses that were either absent, applied less frequently (9,12) or limited to narrow slabs of tissue using reduced bandwidth pulses (11), all tradeoffs that limit the capability of suppressing residual tissue background and venous blood signals.
The aim of this study was to implement SAR reduction strategies to use both venous saturation and MT pulses in TOF MRA protocols at 7T. For this purpose, the variable-rate selective excitation (VERSE) principle (14) was used to design excitation and saturation RF pulses, and a sparse excitation scheme was used to apply MT RF pulses (15). The impact of B0 inhomogeneity and fat chemical shift on VERSE RF pulse excitation profiles at 7T was also investigated.
Methods
Experiments were performed on a whole body 7T system (Siemens Medical Solutions, Germany) equipped with either a whole body gradient or a head gradient coil, using a homebuilt 16-channel transceiver head coil similar to (16) powered with 16×1 kW RF amplifiers (Communication Power Corporation, USA). Healthy volunteers, who signed a consent form approved by the Institutional Review Board (University of Minnesota), were imaged in supine position. Using initial cerebral scout images the patient table was moved to position the Circle of Willis approximately at iso-center of the gradient coil.
VERSE RF pulse design
A VERSE RF pulse design algorithm, similar to the original proposal (14), was implemented in a TOF sequence using the manufacturer’s programming tools (IDEA VB15). A standard RF pulse b1 (n), available within the IDEA framework, was chosen as the starting point for the VERSE algorithm. The complex-valued RF pulse and the corresponding scalar gradient waveform g(n) calculated by the sequence were defined for N samples of duration Δt (RF dwell time) with n ∈ [1,2,….,N]. For simplicity, both b1 (n) and g(n) are assumed to be defined with same N and Δt values, thus with same duration T = N · Δt. Gradient ramps before and after the RF pulse are not considered through the manuscript, thus the gradient amplitude during a standard RF pulse is constant with g(n) = ĝ. A VERSE RF pulse and the corresponding VERSE gradient waveform gV (n) with slew rate sV (n) are then calculated based on b1 (n) and g(n), fulfilling four constraints:
(1) |
(2) |
(3) |
(4) |
Here TV denotes the duration of the final VERSE pulse, gmax, smax and bmax denote the maximum gradient, slew rate and RF amplitude, respectively. smax is set to a value of 100mT/m/ms and bmax is set to a fraction κ of the maximal RF amplitude of the initial pulse: bmax = κ · max[b1 (n)]. The κ values utilized in our simulations and experiments were 100%, 50%, 33% and 25% for excitation RF pulses (κEXC), and 25% for saturation RF pulses (κSAT). The value of gmax is determined in order to keep the total RF pulse duration constant (Eq. 1). The VERSE RF pulse design essentially consists of stretching (shrinking) in time the segments of the initial RF pulse having high (low) amplitude, while RF and gradient amplitude are simultaneously decreased (increased) inversely to maintain the zeroth b1 moment (i.e., the flip angle). To satisfy hardware constraints, RF and gradient waveforms are finally re-sampled on equidistant time raster with dwell times of for VERSE RF pulses and for VERSE gradient waveforms. More details of the algorithm can be found in (17).
Initial and VERSE excitation RF pulses, both having a duration of 1536µs, are shown together with the corresponding gradient waveforms in Fig. 1 for κEXC= 100% (no VERSE), κEXC=50% and κEXC=25%. Under ideal conditions, the excitation pulses generate a rectangular shaped excitation profile. We refrained from using tilted optimized non-saturating excitation (TONE) RF pulses (18) to better estimate profile distortions resulting from ΔB0. The same VERSE algorithm was applied to the venous saturation pulse targeting a 40mm-thick travelling slab, placed cranially to the excitation slab. The initial RF pulse shape was identical to Fig. 1 with a duration of 3584 µs for VERSE and non-VERSE RF pulse. Further details on RF pulse-related parameters are given in Table 1.
Table 1.
Initial excitation pulse |
VERSE excitation pulse 1 |
VERSE excitation pulse 2 |
Initial saturation pulse |
VERSE saturation pulse |
|
---|---|---|---|---|---|
bmax/max[b1(n)]† | 100% | 50% | 25% | 100% | 25% |
Duration [µs] | 1536 | 1536 | 1536 | 3584 | 3584 |
Slice thickness [mm] | 24 | 24 | 24 | 40 | 40 |
Gmax [mT/m] | 6.04 | 6.76 | 11.61 | 1.28 | 2.35 |
Gmin [mT/m] | - | 3.02 | 1.51 | - | 0.32 |
pulse energy | 100% | 57.6% | 33.9% | 772% | 296 % |
the ratio κ=bmax/max[b1(n)] corresponds to κEXC and κSAT for excitation and saturation RF pulses, respectively. By our definition κ=100% when the VERSE algorithm is not applied.
Excitation and saturation RF pulse profiles
Simulations
The impact of B0 inhomogeneities on VERSE RF excitation profiles was investigated with numerical simulations of the Bloch equations. Transverse magnetizations after RF excitation were calculated using MATLAB (The MathWorks Inc., USA). In a first series of simulations, the value of κEXC was fixed to 25%, and the resonance frequency offset (Δfoff) was varied: −1kHz, 0Hz, +150Hz or +300Hz. (−1kHz approximates the fat chemical shift (~3.5ppm) at 7T). In a second series, Δfoff was set to 300Hz while the VERSE algorithm was applied with a κEXC value of 25%, 33% or 50%. All other simulation parameters are listed in Table 1.
Distortions of the resulting VERSE excitation profiles in the presence of a frequency offset were characterized by three parameters: average slope, slab center shift and side-lobe amplitude. The average slope of the slab profile was calculated from a linear fit to the slice profile using data points only within an interval of ±5mm around the slab center. Results are expressed as percentage of signal variation over the 10mm interval, relative to the signal amplitude at the slab center. The expected slab center position was determined based on the FWHM boundaries of the initial (ideal) profile, and the signal amplitude at these boundaries was used to calculate the slab center position of the distorted profile. The corresponding slab center shift was calculated relative to the ideal profile. The maximum side-lobe amplitude was normalized to the profile intensity at the center of the ideal slab. Numerical simulations were also performed to calculate longitudinal magnetization profiles when applying VERSE to saturation RF pulses with κSAT=25%.
Phantom and In-Vivo Experiments
Slab excitation profiles were measured for excitation RF pulses designed with κEXC=25%, using identical RF pulse parameters as in numerical simulations, with a modified version of the 3D TOF sequence allowing for imaging a larger FOV than the excitation slab along the slab direction. Prior to applying this TOF sequence, a multi-slice ΔB0 map (dual gradient echo images, TE1/TE2=5.0/6.0ms) was acquired after second order B0 shimming, and a 3D magnitude transmit B1 (B1+) map was obtained using the Actual Flip Angle (AFI) technique (19). For in-vitro experiments, excitation profiles were measured in a doped phantom (3.75g NiSO4 + 5g NaCl per 1000g H20; measured T1=80ms) with imaging parameters listed in Table 2. The imaging FOV along the slab direction was set to 72mm, i.e. three times the nominal 24mm excitation thickness of the axial slab, to visualize profile side-lobes and to avoid aliasing. To remove spatial transmit and receive variations of the RF coil from the profile, an additional 3D acquisition was obtained using identical imaging parameters except for a non-selective RF excitation, and a large FOV of 240mm in slab direction to avoid aliasing. Saturation effects were reduced by using a phantom with a short T1 together with a relatively small flip angle (20°) and a TR≈T1 (80ms). The total acquisition time for the 3D dataset was 41min. The difference between measured and simulated profiles was quantified by root mean square error (RMSE).
Table 2.
Sequence | Excitation profile in phantom† |
Excitation profile in-vivo† |
TOF in-vivo |
---|---|---|---|
Parameters | |||
FOV x,y,z | 160×160×72 mm3 | 220×165×72 mm3 | 220×172×78 mm3 |
Resolution: | 2.50×2.50×0.50 mm3 | 3.43×3.43×1.00 mm3 | 0.49×0.49×0.50 mm3 |
Slab Thickness | 24 mm | 24 mm | 24 mm |
Slabs | 1 | 1 | 4 (or 1‡) |
TR / TE [ms] | 80 ms / 2.8 ms | 80 ms / 2.8 ms | 33 ms / 3 ms |
alpha (nominal) | 20° | 8° | 24° |
Slab oversampling | 300% | 300% | 125% |
Slab overlap | - | - | −25% |
GRAPPA | 1 | 1 | 3 |
Partial Fourier | - | 6/8 (phase only) | 6/8 (slab only) |
a modified 3D TOF sequence was used to measure the excitation profiles with larger imaging FOV along the slab axis
only one slab was used when investigating the impact of applying VERSE on SAT pulses
In-vivo excitation profiles were obtained in the human brain. To reduce the acquisition time while limiting the impact of long T1 relaxation times (about 1220ms/2132ms/4200ms in gray-matter/white-matter/CSF at 7T (4)), acquisitions were performed at a lower spatial resolution (cf. Table 2) and with a smaller flip angle (8°). For further analysis of profile distortions resulting from ΔB0 inhomogeneities, two 3-by-3 pixel ROIs were defined: one in the frontal lobe, above the nasal cavity where ΔB0 is typically ~1ppm, the other in the center of the brain, where the transmitter frequency was calibrated. Average profiles along the slab direction were calculated for both ROIs.
TOF acquisition
3D TOF data sets were acquired as multiple, partially overlapping thin slabs merged during image post-processing (20). Prior to TOF measurements, ΔB0 and B1+ maps were acquired and the transmitter frequency was set to the Larmor frequency in the center of the brain, based on the measured ΔB0 maps. The transmitter voltage was calibrated for the nominal flip angle at the Circle of Willis. Different TOF acquisitions, described below, were performed to investigate the impact of using VERSE excitation pulses, of applying VERSE venous saturation pulses and of including sparse MT pulses. Based on these results, a trade-off was determined to acquire high contrast, multi-slab TOF angiograms within acceptable SAR limits.
Impact of κEXC in the presence of ΔB0
To study in-vivo the impact of κEXC on the signal at slab overlaps, TOF datasets were acquired using three different κEXC values for VERSE excitation RF pulse design: 100% (no VERSE), 50% and 25%. Neither venous saturation nor MT was enabled for this acquisition. Because errors in the excitation slab profile can especially alter image quality at slab junctions, the inter-slab overlap, usually set to 25% (default value) to ensure smooth transitions through slabs, was reduced to 15% to better identify profile errors close to slab edges. Imaging parameters for this acquisition were: TR/TE=27ms/2.7ms, α=20, FOV=220×172×65mm3, 3 slabs of 24mm thickness, 0.6mm isotropic voxels.
Impact of VERSE saturation pulses
Four different TOF acquisitions were compared to investigate the impact of applying VERSE on saturation pulses: i) TOF sequence with initial excitation pulses (no VERSE) and without venous saturation pulses, ii) VERSE applied on excitation pulses (κEXC=50%) but no saturation pulses were used, iii) VERSE applied on excitation and saturation pulses (κEXC=50%, κSAT=25%), iv) same acquisition as iii but with reversed polarity of saturation slab selection gradient (together with opposite sign of transmitter frequency offset). The latter acquisition was performed to investigate the effects of the saturation RF pulses on fat signal within the imaging slab. Other imaging parameters are summarized in the rightmost column of Table 2 except that only one slab was acquired to reduce the acquisition time. In five subjects the venous signal suppression was quantified by calculating a venous vessel-to-background-ratio (vVBR), i.e. the ratio of the average signal in the sagittal sinus and the average signal from static background tissue surrounding the sinus.
Impact of MT pulses
MT pulses were applied sparsely, i.e. only on NMT central k-space lines out of NTOT total lines. In this study the ratio NMT/NTOT was increased from 0% to 36% and the highest NMT value was determined based on the maximum acceptable SAR. No venous saturation was applied; imaging parameters were identical to Table 2 (rightmost column) but with one slab. To optimize the TOF contrast, an arterial vessel-to-background ratio (aVBR) was determined as a function of NMT/NTOT by dividing the average signal in the basilar artery close to the Circle of Willis by the average signal from the surrounding background tissue. For comparison, aVBR was also calculated in other protocols, either with VERSE saturation pulses enabled (κSAT=25%), or without saturation and without MT pulses.
TOF Tradeoff
Based on the results of the previous measurements a TOF protocol was defined, using the acquisition parameters listed in Table 2 (rightmost column), and including VERSE excitation, VERSE saturation and sparse MT pulses. For contrast comparison, this protocol was acquired with two different settings: i) without VERSE, without saturation pulses and without MT pulses, ii) with VERSE excitation/saturation pulses and with sparse MT pulses. In the latter case NMT/NTOT was set to 10% using 17 and 38 k-space lines in slab selection (SL) and phase encoding (PE) direction. The acquisition time for this high resolution protocol was 14min 36s. All SAR values are given in units of the maximum acceptable limit (SARMAX) as provided by the system software.
Results
Excitation and saturation VERSE RF pulse profiles
In general, with decreasing κEXC or increasing ΔB0 VERSE excitation profiles show an increased average slope, slab center shift and side-lobe amplitude (Fig. 2a+b). With κEXC=25%, a 300Hz frequency offset generates an excitation profile with a slope of 45.5%, a side-lobe amplitude of 21.9% and a slab shift of 11.1%. By comparison, without VERSE (κEXC=100%) there is no slope trend, the side-lobe amplitude is 2.3%, and a 4.9% shift of the slab center is seen (Fig. 2a). The excitation profile for fat signal (−1kHz offset) shows a strongly distorted, asymmetric shape with the maximum signal peak shifted by −13.7mm from the original slice center (Fig. 2b).
Similar distortions are observed for the longitudinal magnetization profile of a venous saturation RF pulse with a target slab thickness of 40mm, as shown in Fig. 2c for κSAT=25%. As expected, both the slope and the center slab shift vary as a function of the resonance offset. Note that the gradient polarity determines the relative shift direction of the saturation profile for fat protons, i.e., either towards or away from the TOF imaging slab. This shift can be used to intentionally overlap the fat saturation of the venous saturation pulse with the TOF imaging slab to suppress fat in the final TOF images (21). This is illustrated in Fig. 2c where the fat saturation is strongest at −59mm from the center of the venous saturation slab.
Experimental and simulation profiles for VERSE RF pulses were in good agreement, as illustrated in Fig. 2d where measured (in a phantom) and simulated profiles are shown for κEXC=25% in the absence of significant ΔB0 (<0.1ppm). An RMSE between simulation and experiment of 0.7% was found for the total acquisition window, and of 0.5% within the slice. The same reference voltage was used for all subjects, with a mean flip angle value measured within the Circle of Willis of 24.1°±1.4° (minimum 22.7°, maximum 26.2°) for a nominal flip angle of 24°. SAR generated by excitation and saturation pulses is dependent on κEXC and κSAT: applying the VERSE principle neither to saturation nor to excitation would yield SAR values at 119% of SARMAX for a protocol given in Table 2 (TOF protocol). By contrast, using VERSE with κEXC=50% and κSAT=25% (as used in our TOF tradeoff protocol), results in 49% of SARMAX. In-vivo slice profiles are demonstrated in Fig. 3 for two ROIs: one positioned in the frontal lobe where strong off-resonances between 245Hz and 48Hz occur, one positioned close to the center of the brain, where the off-resonance is between −9.0Hz and −2.7Hz. For the ROI in the frontal lobe with large offset frequencies the slice profiles agree qualitatively with the simulations and the phantom experiments even though a highly heterogeneous ΔB0 distribution is present over the slab. The impact of ΔB0 on multi-slab TOF images acquired with VERSE pulses is especially noticeable in the sagittal MIP images at the junctions between adjacent slabs (Fig. 4). Note that a reduced slab overlap was used intentionally to visualize the slab boundaries, which resulted in dark stripes between adjacent slabs (‘venetian blind’ artifact). Slab edges were most distorted at the lowest κEXC value (25%) in regions with high ΔB0 (frontal lobe above the nasal cavity, white arrows). This dependence on κEXC is further emphasized in the line plots obtained from the source images at the same location (dashed line): noticeable distortions are observed with κEXC=25%, whereas no significant alterations are seen with κEXC=50% compared to κEXC=100%.
Based on these findings, in all subsequent TOF acquisitions a value of κEXC=50% was chosen. For venous saturation pulses, however, κSAT was set to 25% because venous slab profile accuracy is not as critical as TOF slab profile accuracy. Additionally, the spatially shifted fat suppression profile generated by VERSE saturation may overlap with the excitation slab, resulting in improved MIP image quality, and the large SAR reduction allows for applying sparse MT pulses, which further contribute to a better image quality.
Contrast enhancement within SAR limits
Figure 5 compares 3D TOF datasets obtained with a) no VERSE excitation and no saturation, b) with κEXC=50% and no saturation, c) with κEXC=50% and κSAT=25%, d) with same parameters as in c but with reversed polarity of the saturation slab selection gradient (and transmitter frequency offset). The comparison of Fig. 5a with Fig. 5b shows that VERSE excitation does not reduce the image quality: the mean aVBR of the 5 subjects was 6.07±0.53 for κEXC=50% and 6.26±0.54 for κEXC=100%. At the same time, the corresponding relative SAR reduction to 58%, even though relatively limited, provided more flexibility for further usage of saturation (or MT) pulses.
VERSE saturation pulses effectively suppressed venous signals for example in the sagittal sinus (Figs. 5c and 5d). Here, the mean vVBR, determined in 5 subjects, was significantly reduced from 3.72±0.17 without saturation to 0.29±0.03 with κSAT=25%. Furthermore, fat signals were strongly reduced within the imaging slab when the correct gradient polarity was chosen (Fig. 5d), consistent with the spatial shift observed in the fat saturation profiles simulated with VERSE saturation pulses (Fig. 2c). At the slab center the fat signal reduction was larger than 80%, whereas no fat suppression was observed with opposite gradient polarity (Fig. 5c). Note that in the latter case signals from brain tissues (instead of signals from fat) in areas of large ΔB0 variations were partially saturated, as for example in the inferior part of the frontal lobe (Fig. 5c). In addition to the saturation of venous blood and fat, a visible reduction in background signal was obtained improving the contrast from aVBR = 6.07±0.53 without saturation to 7.59±0.73 with VERSE saturation.
On coronal and sagittal views of 3D TOF datasets, signal aliasing in slab direction was seen with VERSE excitation pulses and without saturation pulses (Fig. 5b, white arrows), identified as fat signals excited outside the imaging slab. The chemical shift between water and fat is only 2.2mm when κEXC=100% is used, thus with 25% oversampling (8mm) in the slab direction no aliasing artifact is seen without VERSE excitation (Fig. 5a). Interestingly, the aliased fat signal was strongly reduced in Fig. 5d due to the shifted fat saturation slab with VERSE saturation. As demonstrated in Fig. 6 and Table 3 additional gains in aVBR can be obtained with sparse MT pulses. Figure 6 shows aVBR (circles) as a function of NMT/NTOT with κEXC=50% and without saturation pulse. It can be seen that aVBR first increases from about 6 to 7.25 in the range of 0% to 10%, and then only gradually for NMT/NTOT>10%. Simultaneously, the relative SAR of the MT pulses (dashed line) increases linearly with NMT/NTOT, theoretically reaching up to 204% of SARMAX for NMT/NTOT=100%. Therefore, a value of NMT/NTOT=10% was used in all further in-vivo measurements with MT. Table 3 (rightmost column) summarizes the mean aVBR over all 5 subjects for different combinations of excitation, saturation and MT pulses. The use of VERSE excitation pulses alone does not significantly alter aVBR, but with VERSE saturation or sparse MT aVBR increases by approximately 19% or 21%, respectively. With both saturation and sparse MT, aVBR reaches values of 9.40±1.03, an increase of about 50% compared to the initial TOF settings.
Table 3.
Excitation κEXC |
Saturation κSAT |
MT NMT/NTOT |
SAR (% of SARMAX) |
aVBR |
---|---|---|---|---|
100% | 100% | 100% | 319% | — |
100% | 100% | — | 115% | — |
100% | — | — | 18% | 6.3± 0.5 |
50% | — | — | 11% | 6.1 ± 0.5 |
50% | — | 10% | 31% | 7.6 ± 0.7 |
50% | 25% | — | 49% | 7.5 ± 0.8 |
50% | 25% | 10% | 69% | 9.4 ± 1.0 |
The overall improvement when VERSE excitation, VERSE saturation and MT are simultaneously applied is seen in the MIP images in Fig. 7. Background and fat signals are reduced, especially in the brain periphery, smaller vessels become visible, and bright venous signal is effectively suppressed. This combination of contrast enhancement would not have been possible without the implementation of substantial SAR reduction strategies, as can be seen in Table 3, showing that using saturation and MT pulses with the initial TOF sequence (no VERSE) would yield 319% of SARMAX.
Discussion
Increasing spatial resolution in cerebral MRA can have a significant clinical impact, as it allows detecting lesions or anomalies of brain vessels of very small diameter. This provides a strong rationale to investigate cerebral TOF at ultra high field where gains in SNR and longer tissue T1 relaxation times may help improving spatial resolution and vessel depiction. However, due to SAR limitations at higher field, sequence components that substantially improve TOF contrast and are commonly utilized at 1.5T and 3T have been omitted, or utilized at a suboptimal level, in TOF studies reported so far at 7T (8–13). Our results indicate, that indeed such contrast enhancement modules in their native form would generate about 319% of SARMAX in our 7T TOF protocol. In this study, we aimed at reducing SAR for each RF pulse category in a TOF pulse sequence that includes, as in lower field protocols, venous saturation and MT. Most of the components used in this work to increase TOF contrast have been individually investigated at lower field (6,7,14,15,21,22). However, to our knowledge, is has not been reported that VERSE applied on single slab selective RF saturation pulses in TOF can be used to limit SAR while providing simultaneously venous saturation above the imaging slab, fat saturation within the imaging slab and MT for enhanced background suppression.
For excitation and saturation pulses, SAR was reduced by applying the VERSE principle. It was important to investigate at 7T the impact of ΔB0 on the slice profile quality. Based on simulations and experiments, excitation and saturation profile distortions induced by VERSE in the presence of off-resonance spins were characterized by a global spatial shift, larger side-lobes and overall ramp shaped profiles. All these effects were inversely dependent on the maximum allowed B1 amplitude, controlled by the factor κEXC (or κSAT), which determines how aggressively the VERSE algorithm is applied to reduce SAR. Severe distortions of the excitation profile may cause signal drops at junctions of overlapping slabs, as seen in Fig. 4, and may reduce signal homogeneity in vessels traversing the slab, depending on blood velocity. In addition, side-lobes may cause aliasing artifacts. For TOF MRA applications, excitation profiles were satisfactory as long as VERSE excitation pulses were designed with κEXC≥50%.
In clinical applications, TONE pulses with ramp shaped excitation profiles are often used to reduce arterial blood saturation through the imaging slab. In this work however, only RF pulses with rectangular excitation profile were used to obtain a better estimation of excitation profile alterations when using VERSE pulses. Similar profile alterations however have been reported with VERSE TONE RF pulses at 7T (23).
With VERSE, saturation pulse side-lobes resulting from off-resonance offsets impair neither venous saturation nor image quality as long as they do not reach into the imaging slab. Ramps and spatial shifts may in principle alter the effectiveness of the venous saturation, but this effect was found to be moderate as long as a sufficiently large mean saturation flip angle was maintained. Thus, VERSE saturation pulses designed with κSAT≥25% provided satisfactory quality.
From an SAR level perspective, applying VERSE on saturation pulses resulted in larger total SAR reduction than on excitation pulses, as expected, given the typically high RF power demand for saturation pulses. This, together with the sensitivity of the VERSE excitation profile to ΔB0, could be seen as a reason to apply VERSE only to saturation pulses and not to excitation pulses. However, there are situations where the additional SAR reduction from the VERSE excitation pulses can provide an extra degree of freedom. For example, it has been shown that B1 shimming can improve TOF contrast homogeneity (24). Homogeneous B1 shimming solutions, however, tend to result in higher RF power, thus higher SAR, for a given flip angle.
Note that the TOF protocols were limited by SAR, not by RF amplifiers. The maximum total RF peak power was always below 400W; it is thus anticipated that with a single transmit channel head coil, a 8kW amplifier would be sufficient, even considering losses on the transmit RF path. Regarding the saturation pulses, SAR reduction could in principle be obtained by lowering the saturation flip angle, thus the RF voltage. For example a saturation flip angle of 45° instead of 90° may provide sufficient venous blood suppression. However, at 7T B1+ profiles in the head typically present large spatial heterogeneities. In this study, flip angles through the brain could vary as much as between 12° and 90° for a nominal value of 60°. Reducing the overall saturation RF power in this case may not provide satisfactory saturation in locations of low B1+ magnitude. (Note that a somewhat weaker fat suppression observed in the frontal part of the head is possibly the result of a weaker local B1+).
Another, well known alternative to reduce SAR consists of prolonging RF pulses to the cost of increasing minimum TR and TE. In this work, however, we demonstrated that even under the more demanding constraint of constant minimum TR, TOF contrast enhancement can successfully be obtained at 7T without reaching SAR limits. We found that the shortest possible TR with saturation and MT pulses (TR=33ms), together with a flip angle of 24°, provided a satisfactory tradeoff between TOF contrast and acquisition time. To reduce SAR with longer pulses at a similar spatial fat chemical shift, saturation pulses without VERSE would require a 3.1 times longer duration.
Because of the large fat chemical shift at 7T, the profile of VERSE excitation pulse also shows a spatial shift for fat protons along the slab direction (Fig. 2b). This causes the aliasing artifacts from fat in Fig. 5, despite the 25% image slab oversampling (8mm) along the slab direction. Cerebral TOF MIP angiograms are not directly impaired by these artifacts, because aliased subcutaneous fat signals are still restricted outside brain tissues. Furthermore, this fat artifact was suppressed by up to 90% by the shifted fat profile of VERSE saturation pulse with correct slab selective gradient polarity. Additional control on the location of maximum fat signal suppression is obtained by adjusting the distance between imaging and saturation slabs. In this work we used an inter-slab distance of 10mm, resulting in fat suppression peak localized at 5mm below the imaging slab, a combination that provided strong attenuation of fat aliasing artifacts while preserving efficient vein suppression. Finally, the fat saturation profile can also be tailored by adjusting saturation slab thickness and/or κSAT.
As seen in Fig. 5, venous saturation RF pulses do not only reduce signals from venous blood and aliased fat, they also significantly enhance the arterial contrast due to an increased background suppression that results from MT properties of saturation pulses. This effect has been reported by Miyazaki (22) with a slab selective MT pulse reducing background signals without affecting inflowing arterial blood spins. In our experiments the ratio of background signal with saturation to background signal without saturation amounted to 0.778±0.074, whereas the corresponding ratio of signal intensity within the arterial vessel remained unchanged.
Besides the magnetization transfer component of saturation pulses, the addition of sparse MT pulses significantly increased the angiographic contrast, as previously reported at lower field (15,25). However, even after the large SAR reduction obtained when applying VERSE on excitation and saturation pulses, MT pulses could only be applied to a small fraction of k-space without exceeding SARMAX. As shown in Fig. 6, the main contrast improvement was obtained with MT applied to 10% of the k-space lines (a level at which SAR increases about 20%). Increasing the fraction beyond 10% only modestly improved the angiographic contrast, at the cost of substantial increase in SAR. Interestingly, the contrast improvement from sparse MT pulses and from the MT component of the saturation pulses appear to add up, as seen in Table 3, resulting in 50% higher angiographic contrast when using both VERSE saturation and sparse MT pulses compared to the initial TOF sequence. Corresponding enhanced visibility of smaller vessels can be visually appreciated in Fig. 7.
In summary, enabling VERSE for excitation (κEXC=50%) and saturation pulses (κSAT=25%) reduced SAR by a factor of more than 2.3 in a 3-slab TOF 7T protocol at 0.49×0.49×0.50mm3 resolution. Simultaneously the artery-to-background contrast ratio was improved and signals from veins and subcutaneous fat were attenuated. The SAR reduction allowed for implementing sparse MT pulses (10% of k-space lines) for additional background suppression, with the total SAR amounting to 69% of SARMAX; this number preserves some flexibility for clinical situations where higher SAR levels may be reached for a given protocol (e.g. larger RF coil load).
Acknowledgements
This work was funded by: German Research Foundation, grant number DFG SCHM 2677/1-1; National Institutes of Health, grant numbers P41 RR008079, P30 NS057091, R01 EB000331; Keck Foundation.
References
- 1.Miyazaki M, Lee VS. Nonenhanced MR angiography. Radiology. 2008;248(1):20–43. doi: 10.1148/radiol.2481071497. [DOI] [PubMed] [Google Scholar]
- 2.Bernstein MA, King KF, Zhou XJ. Handbook of MRI Pulse Sequences. Elsevier Academic Press; 2004. [Google Scholar]
- 3.Ugurbil K, Adriany G, Andersen P, Chen W, Garwood M, Gruetter R, Henry PG, Kim SG, Lieu H, Tkac I, Vaughan T, Van De Moortele PF, Yacoub E, Zhu XH. Ultrahigh field magnetic resonance imaging and spectroscopy. Magn Reson Imaging. 2003;21(10):1263–1281. doi: 10.1016/j.mri.2003.08.027. [DOI] [PubMed] [Google Scholar]
- 4.Rooney WD, Johnson G, Li X, Cohen ER, Kim SG, Ugurbil K, Springer CS., Jr Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo. Magn Reson Med. 2007;57(2):308–318. doi: 10.1002/mrm.21122. [DOI] [PubMed] [Google Scholar]
- 5.Vaughan JT, Garwood M, Collins CM, Liu W, DelaBarre L, Adriany G, Andersen P, Merkle H, Goebel R, Smith MB, Ugurbil K. 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn Reson Med. 2001;46(1):24–30. doi: 10.1002/mrm.1156. [DOI] [PubMed] [Google Scholar]
- 6.Lin W, Tkach JA, Haacke EM, Masaryk TJ. Intracranial MR angiography: application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity-compensated sequences. Radiology. 1993;186(3):753–761. doi: 10.1148/radiology.186.3.8430184. [DOI] [PubMed] [Google Scholar]
- 7.Edelman RR, Ahn SS, Chien D, Li W, Goldmann A, Mantello M, Kramer J, Kleefield J. Improved time-of-flight MR angiography of the brain with magnetization transfer contrast. Radiology. 1992;184(2):395–399. doi: 10.1148/radiology.184.2.1620835. [DOI] [PubMed] [Google Scholar]
- 8.Kang CK, Park CW, Han JY, Kim SH, Park CA, Kim KN, Hong SM, Kim YB, Lee KH, Cho ZH. Imaging and analysis of lenticulostriate arteries using 7.0-Tesla magnetic resonance angiography. Magn Reson Med. 2009;61(1):136–144. doi: 10.1002/mrm.21786. [DOI] [PubMed] [Google Scholar]
- 9.Conijn MM, Hendrikse J, Zwanenburg JJ, Takahara T, Geerlings MI, Mali WP, Luijten PR. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study. Eur Radiol. 2009;19(12):2986–2992. doi: 10.1007/s00330-009-1485-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Heverhagen JT, Bourekas E, Sammet S, Knopp MV, Schmalbrock P. Time-of-flight magnetic resonance angiography at 7 Tesla. Invest Radiol. 2008;43(8):568–573. doi: 10.1097/RLI.0b013e31817e9b2c. [DOI] [PubMed] [Google Scholar]
- 11.Maderwald S, Ladd SC, Gizewski ER, Kraff O, Theysohn JM, Wicklow K, Moenninghoff C, Wanke I, Ladd ME, Quick HH. To TOF or not to TOF: strategies for non-contrast-enhanced intracranial MRA at 7 T. MAGMA. 2008;21(1–2):159–167. doi: 10.1007/s10334-007-0096-9. [DOI] [PubMed] [Google Scholar]
- 12.Zwanenburg JJ, Hendrikse J, Takahara T, Visser F, Luijten PR. MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7 T: comparison with time-of-flight. J Magn Reson Imaging. 2008;28(6):1519–1526. doi: 10.1002/jmri.21591. [DOI] [PubMed] [Google Scholar]
- 13.von Morze C, Xu D, Purcell DD, Hess CP, Mukherjee P, Saloner D, Kelley DA, Vigneron DB. Intracranial time-of-flight MR angiography at 7T with comparison to 3T. J Magn Reson Imaging. 2007;26(4):900–904. doi: 10.1002/jmri.21097. [DOI] [PubMed] [Google Scholar]
- 14.Conolly S, Nishimura DG, Macovski A, Glover G. Variable-rate selective excitation. J Magn Reson. 1988;78:440–477. [Google Scholar]
- 15.Parker DL, Buswell HR, Goodrich KC, Alexander AL, Keck N, Tsuruda JS. The application of magnetization transfer to MR angiography with reduced total power. Magn Reson Med. 1995;34(2):283–286. doi: 10.1002/mrm.1910340221. [DOI] [PubMed] [Google Scholar]
- 16.Adriany G, Van de Moortele PF, Ritter J, Moeller S, Auerbach EJ, Akgun C, Snyder CJ, Vaughan T, Ugurbil K. A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla. Magn Reson Med. 2008;59(3):590–597. doi: 10.1002/mrm.21488. [DOI] [PubMed] [Google Scholar]
- 17.Schmitter S, Bock M. Acoustic noise-optimized VERSE pulses. Magn Reson Med. 2010;64(5):1446–1452. doi: 10.1002/mrm.22549. [DOI] [PubMed] [Google Scholar]
- 18.Atkinson D, Brant-Zawadzki M, Gillan G, Purdy D, Laub G. Improved MR angiography: magnetization transfer suppression with variable flip angle excitation and increased resolution. Radiology. 1994;190(3):890–894. doi: 10.1148/radiology.190.3.8115646. [DOI] [PubMed] [Google Scholar]
- 19.Yarnykh VL. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med. 2007;57(1):192–200. doi: 10.1002/mrm.21120. [DOI] [PubMed] [Google Scholar]
- 20.Parker DL, Yuan C, Blatter DD. MR angiography by multiple thin slab 3D acquisition. Magn Reson Med. 1991;17(2):434–451. doi: 10.1002/mrm.1910170215. [DOI] [PubMed] [Google Scholar]
- 21.Doyle M, Matsuda T, Pohost GM. SLIP, a lipid suppression technique to improve image contrast in inflow angiography. Magn Reson Med. 1991;21(1):71–81. doi: 10.1002/mrm.1910210110. [DOI] [PubMed] [Google Scholar]
- 22.Miyazaki M, Kojima F, Ichinose N, Onozato Y, Igarashi H. A novel saturation transfer contrast method for 3D time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique. Magn Reson Med. 1994;32(1):52–59. doi: 10.1002/mrm.1910320108. [DOI] [PubMed] [Google Scholar]
- 23.Schmitter S, Johst S, Bock M, Ugurbil K, Van de Moortele PF. Implementing VERSE for Time of Flight RF Pulses at 7Tesla: Methodological Considerations. Proceedings of the 18th Annual Meeting of ISMRM; Stockholm, Sweeden. 2010. (Abstract 4424) [Google Scholar]
- 24.Schmitter S, Auerbach EJ, Adriany G, Ugurbil K, Van de Moortele PF. Improving TOF angiography contrast homogeneity with B1+ shimming at 7 Tesla: benefits and challenges. Proceedings of the 19th Annual Meeting of ISMRM; Montral, Canada. 2011. (Abstract 1287) [Google Scholar]
- 25.Lin C, Bernstein MA, Gibbs GF, Huston J., 3rd Reduction of RF power for magnetization transfer with optimized application of RF pulses in k-space. Magn Reson Med. 2003;50(1):114–121. doi: 10.1002/mrm.10513. [DOI] [PubMed] [Google Scholar]