Skip to main content
Journal of Ophthalmic & Vision Research logoLink to Journal of Ophthalmic & Vision Research
. 2011 Jan;6(1):26–31.

Effect of Cataract Type and Severity on Visual Acuity and Contrast Sensitivity

Javad Heravian Shandiz 1,, Akbar Derakhshan 2, Ameneh Daneshyar 1, Abbas Azimi 1, Hadi Ostadi Moghaddam 1, Abbas Ali Yekta 1, Seyed Hosein Hoseini Yazdi 3, Habibollah Esmaily 4
PMCID: PMC3306069  PMID: 22454703

Abstract

Purpose

To determine the effect of cataract type and severity in eyes with pure types of age-related lens opacities on visual acuity (VA) and contrast sensitivity in the presence and absence of glare conditions.

Methods

Sixty patients with senile cataracts aged 40 years or older with no other ocular pathologies were evaluated for VA and contrast sensitivity with and without glare. Lens opacities were classified according to the Lens Opacities Classification System (LOCS) III. VA was measured using the Snellen chart. Contrast sensitivity was measured with the Vector Vision CSV-1000E chart in the presence and absence of glare by calculating the area under log contrast sensitivity (log CS) function (AULCSF).

Results

Cataracts were posterior subcapsular in 26 eyes, cortical in 19 eyes and nuclear in 15 eyes. VA significantly decreased with increasing cataract severity and there was significant loss of contrast sensitivity at all spatial frequencies with increasing cataract severity. AULCSF significantly decreased with increasing cataract severity in the presence and absence of glare conditions. Contrast sensitivity was significantly reduced at high spatial frequency (18 cpd) in cortical cataracts in the presence of glare in day light and at low spatial frequency (3 cpd) in night light.

Conclusion

Increased cataract severity is strongly associated with a decrease in both VA and AULCSF. Contrast sensitivity scores may offer additional information over standard VA tests in patients with early age-related cataracts.

Keywords: Contrast Sensitivity, Glare Sensitivity, Visual Acuity, Age-Related Cataract

INTRODUCTION

Visual acuity (VA) is the conventional and standard test of visual function in patients with cataracts. However, some patients retain relatively good VA, yet complain of poor vision.13 In these patients, other tests of visual function such as contrast sensitivity (CS) should be evaluated.47

Contrast sensitivity measures visual performance under real-life conditions and therefore can better quantify patients’ capabilities.8,9 Cataracts are thought to increase intraocular light scatter, which can decrease retinal image contrast and adversely affect contrast sensitivity10, which is affected far more than visual acuity in patients with cataracts.1,10,11 Fujikado et al12 found that higher-order aberrations are significantly correlated with contrast sensitivity at intermediate to higher spatial frequencies in eyes with cataracts.

Patients with cataracts often complain of glare, for example from bright sunlight or car headlights: some find this glare more disabling than a moderate drop in visual acuity. These symptoms have been termed as glare disability.13,14

It has been reported that glare disability with cataracts does not correlate with visual acuity.1517 Therefore, a patient may have significant glare disability despite good visual acuity. Abrahamsson and Sjostrand18 found that reduced contrast sensitivity functions as a measure of glare disability in patients with early cataracts. They suggested that a normal individual has a glare score that is almost independent of luminance level, while patients with cataracts have a marked increase in glare sensitivity when luminance is decreased. Jaffe19 suggested that glare disability can be used as an adjunct to VA measurement in order to objectively assess the need for cataract surgery. There are some commercially available charts for measuring contrast sensitivity without glare source. It has been reported that a patient may have good visual acuity but significant contrast and glare disability.2024 The aim of this study was to investigate the discriminative ability of the CSV-1000E test with glare source to measure contrast sensitivity and glare disability in patients with early cataracts.

METHODS

Our patients were selected from participants of an ongoing descriptive study at Khatam-Al-Anbia Eye Hospital on the natural history of age-related cataracts. Patients aged 40 to 75 years with no other ocular diseases other than cataracts (glaucoma, optic nerve disease, macular diseases or anterior segment disease) were enrolled for the study. All subjects had at least one eye with a single type of cataract (pure cortical, pure nuclear or pure posterior subcapsular). Preference was given to the eye with the highest lens opacity grade and to the right eye when both eyes had similar degrees of lens opacities.

Each patient underwent a complete ophthalmologic and optometric eye examination. Best corrected VA (BCVA) was determined monocularly using the Snellen chart and contrast sensitivity was measured with a sine-wave grating at spatial frequencies of 3, 6, 12, and 18 cpd using the Vector Vision CSV-1000E chart (Vector Vision, Haag-Streit, Harlow, UK). Glare sensitivity was measured in day and night light. For this purpose, the Vector Vision CSV-1000E contrast test houses a series of photocells that monitor and calibrate the instrument light level to day or night light (Fig. 1). The chart is back-illuminated and viewed from 8 feet with mean luminance of 85 cd/m2 (low photopic condition).24 The chart consists of four rows of patches. Each row presents 17 circular patches 1.5 inches in diameter. The first patch on the far left in each row presents a very high contrast grating (sample patch). The remaining 16 patches appear in 8 columns across the row. In each column, one patch presents a grating and the other patch is blank. The patches that present grating decrease in contrast moving from left to right across the row. The patient indicates whether grating appears in the top patch or the bottom patch for each column.25

Figure 1.

Figure 1

Contrast sensitivity test system.

Sensitivity values were transformed into a logarithmic scale, and each subject’s area under the log contrast sensitivity (log CS) function (AULCSF) was calculated. AULCSF represents sensitivity of the entire visual system to contrast and is calculated as follows:24

AULCSF=0.5logCS(3cd)logCS(6cd)+0.75logCS(12cd)+0.25logCS(18cd)

Classification and grading of lens opacities was performed using a slitlamp and according to the Lens Opacities Classification System III (LOCS III). The grade for each feature was derived by locating the image of the patient’s lens on the scale of severity for each feature represented in the colour transparency.25

All statistical analyses were performed only for the eye with pure age-related cataract. For statistical analysis, Snellen acuities were converted to equivalent values of visual angle using the decimal scale. Descriptive and inferential data analyses were performed using SPSS, version 11.5. Correlation was tested between cataract severity and age using a general linear model to control for the effect of age and sex. Repeated measurement of analysis of variance (ANOVA) was performed to test the difference between contrast sensitivity with and without glare at all spatial frequencies for each type of cataract. Significant differences between each paired group were then evaluated by the least significant difference LSD test.

RESULTS

Sixty eyes of 60 patients with mean age of 59.0±9.6 (range, 40 to 75) years were studied. Cataracts were pure posterior subcapsular (PSC) in 26 eyes, cortical (CC) in 19 eyes and nuclear opacities (NO) in 15 eyes.

Spearman correlation coefficient showed that patients with more severe opacities were older (Fig. 2; r=0.27, P=0.036). Increasing cataract severity was also correlated with decreasing VA (P<0.001, F=14.27). Contrast sensitivity values with and without glare in day and night light were compared among different types of cataract at all spatial frequencies. Contrast sensitivity was significantly reduced in all types of cataracts at all tested spatial frequencies without glare (Table 1). LSD test of significant differences between each paired group revealed that mean contrast sensitivity was significantly reduced at high spatial frequency (18 cpd) in cortical cataracts in the presence of glare in day light (P<0.001) and at low spatial frequency (3 cpd) in night light (P<0.001).

Figure 2.

Figure 2

Correlation between age and cataract severity in patients with age-related cataract (rs=0.27).

Table 1.

Contrast sensitivity without glare and with glare in day and night light

Spatial Frequency (cpd) Cataract Type Contrast Sensitivity (Mean ± SD) P-value
Without glare Glare day light Glare night light
3 PSC 0.81 ± 0.24 1.15 ± 0.41 0.45 ± 1.32 <0.001
Cortical 0.8 ± 0.24 1.03 ± 0.38 1.25 ± 0.40
Nuclear 0.92 ± 0.35 1.26 ± 0.36 0.34 ± 1.46
6 PSC 1.036 ± 0.27 1.28 ± 0.38 1.44 ± 0.45 <0.001
Cortical 1.02 ± 0.28 1.23 ± 0.31 1.40 ± 0.40
Nuclear 1.1 ± 0.32 1.40 ± 0.40 1.44 ± 0.41
12 PSC 0.69 ± 0.21 0.96 ± 0.35 1.13 ± 0.44 <0.001
Cortical 0.71 ± 0.27 0.88 ± 0.27 1.11 ± 0.44
Nuclear 0.89 ± 0.32 1.16 ± 0.42 1.27 ± 0.47
16 PSC 0.27 ± 0.27 0.44 ± 0.42 0.66 ± 0.51 <0.001
Cortical 0.29 ± 0.26 0.38 ± 0.27 0.55 ± 0.48
Nuclear 0.51 ± 0.29 0.77 ± 0.40 0.95 ± 0.34

cpd, cycle per degree; SD, standard deviation; PSC, posterior subcapsular

Increased cataract severity was correlated with decreased AULCSF in conditions without glare (P<0.001, F=15.39). A higher correlation was found in day light glare compared to conditions without glare (P<0.001, F=21.36). The correlation between cataract severity and AULCSF in night light glare was also significant, but less than that seen without glare (P<0.001, F=12.91).

DISCUSSION

In this study, we evaluated the effect cataract type and severity on Snellen VA and contrast sensitivity with and without glare using the Vector Vision CSV-1000E. The fact that there was significant reduction in CS at intermediate and high spatial frequencies implied that CS testing may be more sensitive and serve as an adjunct to traditional acuity testing in quantifying the level of visual dysfunction in cataract patients.7 By limiting our analysis to eyes with a pure type of lens opacity, we attempted to eliminate the confounding effect of different types of coexisting opacities. The infrequent occurrence of pure PSC (only 26 eyes were available for this study) suggests that the data relating to this type of cataract must be interpreted cautiously.

Cataracts are known to increase intraocular scatter, thereby reducing retinal image contrast.26,27 Some studies suggest that contrast sensitivity should be measured at low spatial frequencies in eyes with cataract.28,29 Other studies have suggested that high spatial frequency contrast sensitivity is more informative.30 In the present study, we used Vector Vision CSV-1000E chart with contrast sensitivity at all spatial frequencies (low, intermediate and high). We found that increasing cataract severity is associated with a progressive decrease in both VA and AULCSF in conditions with and without glare. Decrease in AULCSF means that contrast sensitivity is decreased at all spatial frequencies on the Vector vision CSV-1000 chart. The effect of light scatter on the retinal image results in decreased retinal contrast.15,18

In a similar study with different methodology, Lasa et al31 found that after adjusting for visual acuity, contrast sensitivity loss was significant only in patients with advanced CC or PSC. Elliott and Gilchrist15 reported that eyes with early nuclear or cortical cataracts had no loss of contrast sensitivity at the lowest spatial frequency, whereas eyes with PSC had contrast sensitivity loss at low spatial frequencies. Stifter et al32 indicated that early PSC and CC opacities cause significant reduction in contrast sensitivity at intermediate and high spatial frequencies, but high grade cataracts reduce contrast sensitivity at all spatial frequencies. They also demonstrated that early nuclear cataracts cause no loss of contrast sensitivity at the lowest spatial frequency, whereas eyes with PSC show contrast sensitivity loss even at low spatial frequencies.

Higher-order aberrations are significantly correlated with contrast sensitivity at intermediate to high spatial frequencies in eyes with cataract. Fujikado et al12 found that loss of contrast sensitivity was closely related to the optical density of the cataract, which confirms our findings. However it is still unclear whether front or back light scatter, or higher-order aberrations contribute more significantly to optical degradation in eyes with cataract leading to decreased contrast sensitivity. In our study, contrast sensitivity without glare was reduced in all types of cataracts; but the difference in contrast sensitivity among the three types of cataract was not statistically significant.

In the current study, contrast sensitivity declined in the presence of glare (day and night light) with cortical cataracts. Cortical cataracts tend to form wedge-shaped spokes around the pupil that mainly affect high spatial frequencies. These opacities may cause significant glare when they encroach upon the visual axis.31,32 Although nuclear cataracts are located centrally, they are more diffuse in nature, unlike PSC opacities which are usually more dense and discrete.32 Measurement of CS at all spatial frequencies in the presence of glare in night or day light conditions appears to be helpful in assessment of visual function in patients with cortical and posterior subcapsular cataracts. The Vector Vision Contrast sensitivity test with glare source measures visual performance under real life conditions and gives a more complete quantification of visual function. In our study, the severity of cortical cataracts was greater than posterior subcapsular and nuclear opacities. Late cortical cataracts are associated with denser opacities in the center of the lens affecting the visual axis, therefore contrast sensitivity is more severely reduced with this type of cataracts.

Chua et al33 found no correlation between cataract type or severity and glare disability which is in contrast to our findings. Interestingly, Chua demonstrated that axially located cortical cataracts most significantly affected visual function in terms of VA, CS and glare disability.

Smith and Holladay34 have stated that the effect of a central obstruction in the aperture of a diffraction limited system is a decrease in its modulation transfer function (MTF) at low spatial frequencies. Coatings that reduce transmission at the center of the aperture tend to decrease MTF at low spatial frequencies while reduced transmission at the edge of the aperture preferentially affects high frequencies.35 In night light conditions and with a glare light source, miosis occurs resulting in decreased MTF at low spatial frequencies with significant cortical cataracts encroaching upon the pupil.

Williamson et al20 reported that all forms of cataract are associated with glare disability. They found that posterior subcapsular opacities induce more severe glare loss than cortical cataracts. In our study however, cataract severity was greatest with cortical opacities, therefore affecting glare sensitivity more than other types.

Martin et al36 demonstrated that regarding both VA and CS, the effect of increasing cataract severity was greatest for nuclear and smallest for cortical opacities, which is different from our findings.

Previous studies have suggested that cataracts predominantly affect CS at high spatial frequencies.1,8,26 We also found that contrast sensitivity is decreased at high spatial frequencies in cortical cataracts in the presence of day light glare.

The advantage of the current study is the use of AULCSF which reflects the entire sensitivity of the visual system to contrast. We also evaluated the effect of cataract type and severity on VA and CS with and without glare.

In summary, increased cataract severity, as determined by LOCS III grading, is strongly associated with a decrease in both VA and contrast sensitivity measured as AULCSF. Measurement of VA alone is insufficient for evaluating visual complaints in patients with cataracts and examinations simulating usual conditions of everyday life such as evaluation of contrast sensitivity in conjunction with a glare source may be of great utility.

Acknowledgements

The authors would like to thank the Vice Chancellor for Research at Mashhad University of Medical Sciences for financial support.

REFERENCES

  • 1.Stifter E, Sacu S, Thaler A, Weghaupt H. Contrast acuity in cataracts of different morphology and association to self-reported visual function. Invest Ophthalmol Vis Sci. 2006;47:5412–5422. doi: 10.1167/iovs.05-1564. [DOI] [PubMed] [Google Scholar]
  • 2.Koch DD. Glare and contrast sensitivity testing in cataract patients. J Cataract Refract Surg. 1989;15:158–164. doi: 10.1016/s0886-3350(89)80004-5. [DOI] [PubMed] [Google Scholar]
  • 3.Elliot DB, Hurst MA, Weatherill J. Comparing clinical tests of visual function in cataract with the patient’s perceived visual disability. Eye (Lond) 1990;4:712–717. doi: 10.1038/eye.1990.100. [DOI] [PubMed] [Google Scholar]
  • 4.Adamsons I, Rubin GS, Vitale S, Taylor HR, Stark WJ. The effect of early cataract on glare and contrast sensitivity. Arch Ophthalmol. 1992;110:1081–1086. doi: 10.1001/archopht.1992.01080200061025. [DOI] [PubMed] [Google Scholar]
  • 5.Rubin GS, Adamsons IA, Stark WJ. Comparison of acuity, contrast sensitivity, and disability glare before and after cataract surgery. Arch Ophthalmol. 1993;111:56–61. doi: 10.1001/archopht.1993.01090010060027. [DOI] [PubMed] [Google Scholar]
  • 6.Adamsons I, Vitale S, Stark WJ, Rubin GS. The association of postoperative subjective visual function with acuity, glare, and contrast sensitivity in patients with early cataract. Arch Ophthalmol. 1996;114:529–536. doi: 10.1001/archopht.1996.01100130521004. [DOI] [PubMed] [Google Scholar]
  • 7.Elliott DB, Situ P. Visual acuity versus letter contrast sensitivity in early cataract. Vision Res. 1998;38:2047–2052. doi: 10.1016/s0042-6989(97)00382-9. [DOI] [PubMed] [Google Scholar]
  • 8.Jindra LF, Zemon V. Contrast sensitivity testing: a more complete assessment of vision. J Cataract Refract Surg. 1989;15:141–148. doi: 10.1016/s0886-3350(89)80002-1. [DOI] [PubMed] [Google Scholar]
  • 9.Owsley C, Sloane ME. Contrast sensitivity, acuity, and the perception of ‘real-world’ targets. Br J Ophthalmol. 1987;71:791–796. doi: 10.1136/bjo.71.10.791. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.American Academy of Ophthalmology. Contrast sensitivity and glare testing in the evaluation of anterior segment disease. Ophthalmology. 1990;97:1233–1237. doi: 10.1016/s0161-6420(90)32431-4. [DOI] [PubMed] [Google Scholar]
  • 11.Terry CM, Brown PK. Clinical measurements of glare effect in cataract patients. Ann Ophthalmol. 1989;21:183–187. [PubMed] [Google Scholar]
  • 12.Fujikado T, Kuroda T, Maeda N, Ninomiya S, Goto H, Tano Y, et al. Light scattering and optical aberrations as objective parameters to predict visual deterioration in eyes with cataracts. J Cataract Refract Surg. 2004;30:1198–1208. doi: 10.1016/j.jcrs.2003.12.023. [DOI] [PubMed] [Google Scholar]
  • 13.Holladay JT, Lang A, Portney V. Analysis of edge glare phenomena in intraocular lens edge designs. J Cataract Refract Surg. 1999;25:748–752. doi: 10.1016/s0886-3350(99)00038-3. [DOI] [PubMed] [Google Scholar]
  • 14.Rochtchina E, Mitchell P, Coroneo M, Wang JJ, Cumming RG. Lower nasal distribution of cortical cataract: the Blue Mountains Eye Study. Clin Experiment Ophthalmol. 2001;29:111–115. doi: 10.1046/j.1442-9071.2001.00413.x. [DOI] [PubMed] [Google Scholar]
  • 15.Elliott DB, Gilchrist J, Whitaker D. Contrast sensitivity and glare sensitivity changes with three types of cataract morphology: are these techniques necessary in a clinical evaluation of cataract? Ophthalmic Physiol Opt. 1989;9:25–30. doi: 10.1111/j.1475-1313.1989.tb00800.x. [DOI] [PubMed] [Google Scholar]
  • 16.Pesudovs K, Elliott DB. Refractive error changes in cortical, nuclear, and posterior subcapsular cataracts. Br J Ophthalmol. 2003;87:964–967. doi: 10.1136/bjo.87.8.964. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Van den Brom HJ, Koojiman AC, Blanksma LJ. Clinical and physical measurements of the cataractous lens. Doc Ophthalmol. 1990;75:247–258. doi: 10.1007/BF00164838. [DOI] [PubMed] [Google Scholar]
  • 18.Abrahamsson M, Sjostrand J. Impairment of contrast sensitivity function (CSF) as a measure of disability glare. Invest Ophthalmol Vis Sci. 1986;27:1131–1136. [PubMed] [Google Scholar]
  • 19.Jaffe NS. Glare and contrast: indications for cataract surgery. J Cataract Refract Surg. 1986;12:372–375. doi: 10.1016/s0886-3350(86)80098-0. [DOI] [PubMed] [Google Scholar]
  • 20.Williamson TH, Strong NP, Sparrow J, Aggarwal RK, Harrad R. Contrast sensitivity and glare in cataract using the Pelli-Robson chart. Br J Ophthalmol. 1992;76:719–722. doi: 10.1136/bjo.76.12.719. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Ginsburg AP. A new contrast sensitivity vision test chart. Am J Ophtom Physiol Opt. 1984;61:403–407. doi: 10.1097/00006324-198406000-00011. [DOI] [PubMed] [Google Scholar]
  • 22.Corwin TR, Richman JE. Three clinical tests of the spatial contrast sensitivity function: a comparison. Am J Optom Physiol Opt. 1986;63:413–418. doi: 10.1097/00006324-198606000-00004. [DOI] [PubMed] [Google Scholar]
  • 23.Ginsburg AP, Waring GO, 3rd, Steinberg EB, Williams PA, Justin N, Deitz JR, et al. Contrast sensitivity under photopic conditions in the Prospective Evaluation of Radial Keratotomy (PERK) study. Refract Corneal Surg. 1990;6:82–91. [PubMed] [Google Scholar]
  • 24.Pomerance GN, Evans DW. Test-retest reliability of the CSV-1000 contrast test and its relationship to glaucoma therapy. Invest Ophthalmol Vis Sci. 1994;35:3357–3361. [PubMed] [Google Scholar]
  • 25.Davison JA, Chylack LT. Clinical application of the lens opacities classification system III in the performance of phacoemulsification. J Cataract Refract Surg. 2003;29:138–145. doi: 10.1016/s0886-3350(02)01839-4. [DOI] [PubMed] [Google Scholar]
  • 26.Pesudovs K, Hazel CA, Doran RM, Elliott DB. The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research. Br J Ophthalmol. 2004;88:11–16. doi: 10.1136/bjo.88.1.11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Gartaganis SP, Psyrojannis AJ, Koliopoulos JX, Mela EK. Contrast sensitivity function in patients with impaired oral glucose tolerance. Optom Vis Sci. 2001;78:157–161. doi: 10.1097/00006324-200103000-00008. [DOI] [PubMed] [Google Scholar]
  • 28.Pelli DG, Robson JG, Wilkins AJ. The design of a new letter chart for measuring contrast sensitivity. Clin Vis Sci. 1988;2:187–199. [Google Scholar]
  • 29.Brown NA, Hill AR. Cataract: the relation between myopia and cataract morphology. Br J Ophthalmol. 1987;71:405–414. doi: 10.1136/bjo.71.6.405. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Elliott DB, Hurst MA, Weatherill J. Comparing clinical tests of visual loss in cataract patients using a quantification of forward light scatter. Eye (Lond) 1991;5:601–606. doi: 10.1038/eye.1991.104. [DOI] [PubMed] [Google Scholar]
  • 31.Lasa MS, Podgor MJ, Datiles MB, 3rd, Caruso RC, Magno BV. Glare sensitivity in early cataracts. Br J Ophthalmol. 1993;77:489–491. doi: 10.1136/bjo.77.8.489. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Stifter E, Sacu S, Weghaupt H. Functional vision with cataract of different morphologies: comparative study. J Cataract Refract Surg. 2004;30:1883–1891. doi: 10.1016/j.jcrs.2004.01.038. [DOI] [PubMed] [Google Scholar]
  • 33.Chua BE, Mitchell P, Cumming RG. Effects of cataract type and location on visual function: the Blue Mountains Eye Study. Eye (Lond) 2004;18:765–772. doi: 10.1038/sj.eye.6701366. [DOI] [PubMed] [Google Scholar]
  • 34.Smith PW, Holladay JT. A clinical comparison of two methods of glare testing. Ophthalmic Surg. 1988;19:293. [PubMed] [Google Scholar]
  • 35.Franssen L, Coppens JE, van den Berg TJ. Compensation comparison method for assessment of retinal straylight. Invest Ophthalmol Vis Sci. 2006;47:768–776. doi: 10.1167/iovs.05-0690. [DOI] [PubMed] [Google Scholar]
  • 36.Martin L. Computerized method to measure glares and contrast sensitivity in cataract patients. J Cataract Refract Surg. 1999;25:411–415. doi: 10.1016/s0886-3350(99)80091-1. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Ophthalmic & Vision Research are provided here courtesy of Ophthalmic Research Center

RESOURCES