Abstract
We report a case of infectious endocarditis attributable to Legionella longbeachae. L. longbeachae is usually associated with lung infections. It is commonly found in composted waste wood products. L. longbeachae should be regarded as an agent of infectious endocarditis, notably in the context of gardening involving handling of potting soils.
Keywords: endocarditis, Legionella longbeachae, potting mixes, respiratory infections, bacteria
Legionella longbeachae is a facultative intracellular gram-negative bacillus commonly found in composted waste wood products used in potting mixes. It is usually associated with lung infections. We report a case of infectious endocarditis attributable to L. longbeachae 6 months after the patient had an aortic valve bioprothesis replacement.
The Patient
In July 2008, a 73-year-old man was admitted to La Timone Hospital, Marseille, France; it was suspected that an aortic bioprosthetic valve had become displaced. The patient had received an aortic bioprosthetic valve replacement in January 2008 for aortic insufficiency. After he returned home in March, he carried out gardening activities and used potting mixes to plant flowers. In April 2008, he was admitted to the emergency department of a general hospital for fever (38.9°C). At admission, his leukocyte count was 12 × 109 cells/L. He was empirically treated with amoxicillin/clavulanic acid plus ciprofloxacin. Results of clinical examination and all investigations (chest radiograph, transesophageal echocardiograph, 3 blood cultures, urine analysis, and Legionella urinary antigen test) did not identify an infectious agent, and antimicrobial drug treatment was stopped after 24 hours.
In May 2008, the patient had a new episode of fever (39°C), with a weight loss of 20 kg within 3 months. He was admitted to the cardiology department of La Timone Hospital. An endocarditis diagnostic kit was used. The endocarditis kit included, besides blood cultures, tubes to collect a serum sample, which was used to detect rheumatoid factor and estimate specific antibodies against Coxiella burnetii, Bartonella spp., Brucella spp., Chlamydia spp., Mycoplasma pneumoniae, Legionella pneumophila, L. anisa, and Aspergillus spp (1). Results of all tests (including transesophageal echocardiograph) were negative. The modified Durack score (2) showed that only 2 minor criteria were met (and no major criteria), and the Richet score was 3 (fever = 1, male = 1, previous valvular pathology = 1), with a positive predictive value of 0.28 and a negative predictive value of 0.82 (3). He was discharged without receiving any antimicrobial drugs.
In July 2008, the patient was hospitalized at La Timone Hospital for heart failure. A transesophageal echocardiograph showed an aortic bioprothesis displacement with a false aneurysm and 9 mm of vegetation (Figure). At admission, leukocyte count was 9.4 × 109 cells/L, hemoglobin level was 9.8 gm/dL, erythrocyte sedimentation rate was 53 mm, and C-reactive protein level was 126 mg/L. A new endocarditis diagnostic kit was used. The blood cultures remained sterile. Results of serologic tests for L. pneumophila and the urinary antigen test for Legionella spp. were negative. Only the serologic test for L. anisa was positive (titer 256). The diagnosis of blood culture–negative endocarditis was established, and intravenous antibiotherapy was begun with vancomycin (30 mg/kg/d) plus gentamicin (3 mg/kg/d).
Cardiac surgery was performed after 30 days because of heart failure. The aortic bioprothesis was replaced. We conducted bacterial 16S rDNA amplification and sequencing on the valvular tissue as reported (4) and found a sequence 100% similar to that of L. longbeachae (GenBank accession no. AY444741). The valvular culture grew gram-negative bacilli that were catalase positive and oxidase negative after 10 days on buffered charcoal yeast extract medium (AES Chemunes, Bruz, France). The strain was identified as L. longbeachae by 16S rDNA (5) and mip gene (6) amplification and sequencing (GenBank accession no. AJ810226).
Histologic examination of the removed valve was performed, and findings were compatible with the diagnosis of infective endocarditis. Results of immunohistochemical analysis performed on the valvular tissue were positive for L. longbeachae. Results of immunofluorescence and Western blot of the patient’s blood were positive for the same strain.
The patient recently used only Australian potting mixes, which may contain L. longbeachae, although we were not able to cultivate L. longbeachae or other Legionella spp. from the potting mix. Vancomycin administration was stopped, and the patient’s treatment was changed to erythromycin (3 g/d intravenously for 6 weeks) and ciprofloxacin (400 mg/d intravenously for 15 days and 1.5 g/d by mouth for 1 month). The patient recovered. At a 3-month follow-up visit, he had gained 6 kg, and no inflammatory syndrome was found. At 6 months, he had gained 13 kg and felt well.
Conclusions
L. longbeachae was first described as a new species in 1981 after it was isolated from a patient with pneumonia in Long Beach, California, USA (7–9). A second serogroup was described in 1981 (10). This species is common in composted wood products used in potting mixes in Australia and in Japan (11,12). Although the composition of potting soil used in Europe is different, Legionnaires’ disease has also been described in Scotland in connection with the use of potting soil (13). A case of pneumonia caused by L. longbeachae associated with gardening was described in 2006 in the Netherlands. L. longbeachae was cultured from the patient’s sputum and from the commercial potting soil he had used (14). The source of contamination for the patient described could be the Australian potting mixes he had used for 1 month before the first symptoms, although a culture of potting soil was negative. The patient did not experience cutaneous inoculation or a wound during gardening, although minor trauma is a possibility.
Noninvasive diagnosis for this patient was not successful: the results of serologic immunofluorescence testing for L. pneumophila and the urinary antigen test for Legionella spp. were negative. Only the serologic testing was positive for L. anisa (titer 256). Cross-reactivity between L. anisa and L. longbeachae should be considered.
In a previous report, a patient with aortic valve endocarditis showed an increase in titers of antibodies against L. bozemanii, L. longbeachae, and L. jordanis, but the infection was not confirmed by the isolation of bacteria (15). The patient was a 38-year-old woman with type 1 diabetes mellitus and bronchial asthma but no medical history of heart disease. She was hospitalized 2 months before acquiring infectious endocarditis for pneumonia and fever caused by M. pneumoniae. Transesophageal echocardiograph showed a thickened bicuspid aortic valve with 5–7-mm vegetation. The serologic test results were positive only for L. bozemanii, L. longbeachae, and L. jordanis. She was treated with erythromycin (1 g 4×/d intravenously, then orally, for 6 weeks, then 1 g 3×/d orally for 2 weeks). For the patient reported here, the diagnosis of infectious endocarditis was definitive because results of PCR, serologic testing, and valvular culture were positive for L. longbeachae.
L. longbeachae should be regarded as an agent of infectious endocarditis, notably in context of gardening involving handling potting soils. Definitive identification was possible only by using molecular biology–based methods on the removed valve and on culture. As mentioned by other investigators, L. pneumophila urinary antigen test should not be used to rule out L. longbeachae infection (13).
Biography
Dr Leggieri has completed internships in internal medicine and infectious diseases in Switzerland. He is completing a postgraduate specialization in endovascular infections at the Fédération de Microbiologie Clinique in Timone’s University Hospital, Marseille, France. His research interests include legionellosis.
Footnotes
Suggested citation for this article: Leggieri N, Gouriet F, Thuny F, Habib G, Raoult D, Casalta J-P. Legionella longbeachae and endocarditis. Emerg Infect Dis [serial on the Internet] 2012 Jan [date cited]. http://dx.doi.org/eid1801.110579
References
- 1.Raoult D, Casalta JP, Richet H, Khan M, Bernit E, Rovery C, et al. Contribution of systematic serological testing in diagnosis of infective endocarditis. J Clin Microbiol. 2005;43:5238–42. 10.1128/JCM.43.10.5238-5242.2005 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Fournier PE, Casalta JP, Habib G, Messana T, Raoult D. Modification of the diagnostic criteria proposed by the Duke Endocarditis Service to permit improved diagnosis of Q fever endocarditis. Am J Med. 1996;100:629–33. 10.1016/S0002-9343(96)00040-X [DOI] [PubMed] [Google Scholar]
- 3.Richet H, Casalta JP, Thuny F, Merrien J, Harle JR, Weiller PJ, et al. Development and assessment of a new early scoring system using non-specific clinical signs and biological results to identify children and adult patients with a high probability of infective endocarditis on admission. J Antimicrob Chemother. 2008;62:1434–40. 10.1093/jac/dkn423 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Greub G, Lepidi H, Rovery C, Casalta JP, Habib G, Collard F, et al. Diagnosis of infectious endocarditis in patients undergoing valve surgery. Am J Med. 2005;118:230–8. 10.1016/j.amjmed.2004.12.014 [DOI] [PubMed] [Google Scholar]
- 5.Weisburg WG, Barns SM, Pelletier DA, Lane DJ. 16S ribosomal DNA amplification for phylogenetic study. J Bacteriol. 1991;173:697–703. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Ratcliff RM, Lanser JA, Manning PA, Heuzenroeder MW. Sequence-based classification scheme for the genus Legionella targeting the mip gene. J Clin Microbiol. 1998;36:1560–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Steele TW, Lanser J, Sangster N. Isolation of Legionella longbeachae serogroup 1 from potting mixes. Appl Environ Microbiol. 1990;56:49–53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Steele TW, Moore CV, Sangster N. Distribution of Legionella longbeachae serogroup 1 and other legionellae in potting soils in Australia. Appl Environ Microbiol. 1990;56:2984–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Lanser JA, Adams M, Doyle R, Sangster N, Steele TW. Genetic relatedness of Legionella longbeachae isolates from human and environmental sources in Australia. Appl Environ Microbiol. 1990;56:2784–90. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Bibb WF, Sorg RJ, Thomason BM, Hicklin MD, Steigerwalt AG, Brenner DJ, et al. Recognition of a second serogroup of Legionella longbeachae. J Clin Microbiol. 1981;14:674–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Hughes MS, Steele TW. Occurrence and distribution of Legionella species in composted plant materials. Appl Environ Microbiol. 1994;60:2003–5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Koide M, Arakaki N, Saito A. Distribution of Legionella longbeachae and other legionellae in Japanese potting soils. J Infect Chemother. 2001;7:224–7. 10.1007/s101560170017 [DOI] [PubMed] [Google Scholar]
- 13.Pravinkumar SJ, Edwards G, Lindsay D, Redmond S, Stirling J, House R, et al. A cluster of Legionnaires' disease caused by Legionella longbeachae linked to potting compost in Scotland, 2008–2009. Euro Surveill. 2010;15:19496. [DOI] [PubMed] [Google Scholar]
- 14.den Boer JW, Yzerman EP, Jansen R, Bruin JP, Verhoef LP, Neve G, et al. Legionnaires' disease and gardening. Clin Microbiol Infect. 2007;13:88–91. 10.1111/j.1469-0691.2006.01562.x [DOI] [PubMed] [Google Scholar]
- 15.Littrup P, Madsen JK, Lind K. Aortic valve endocarditis associated with Legionella infection after Mycoplasma pneumonia. Br Heart J. 1987;58:293–5. 10.1136/hrt.58.3.293 [DOI] [PMC free article] [PubMed] [Google Scholar]