Skip to main content
Springer logoLink to Springer
. 2012 Jan 10;132(5):617–625. doi: 10.1007/s00402-011-1456-5

Systematic review of the complications of plate fixation of clavicle fractures

Frans-Jasper G Wijdicks 1,4,, Olivier A J Van der Meijden 2, Peter J Millett 2,3, Egbert J M M Verleisdonk 1, R Marijn Houwert 1
PMCID: PMC3332382  PMID: 22237694

Abstract

Background

The number of displaced midshaft clavicle fractures treated surgically is increasing and plate fixation is often the treatment modality of choice. The study quality and scientific levels of evidence at which possible complications of this treatment are presented vary greatly in literature.

Purposes

The purpose of this systematic review is to assess the prevalence of complications concerning plate fixation of dislocated midshaft clavicle fractures.

Methods

A computer-based search was carried out using EMBASE and PUBMED/MEDLINE. Studies included for review reported complications after plate fixation alone or in comparison to either treatment with intramedullary pin fixation and/or nonoperative treatment. Two quality assessment tools were used to assess the methodological quality of the studies. Included studies were ranked according to their levels of evidence.

Results

After study selection and reading of the full texts, 11 studies were eligible for final quality assessment. Nonunion and malunion rates were less than 10% in all analysed studies but one. The vast majority of complications seem to be implant related, with irritation or failure of the plate being consistently reported on in almost every study, on average ranging from 9 to 64%.

Conclusion

The quantity of relevant high evidence studies is low. With low nonunion and malunion rates, plate fixation can be a safe treatment option for acute dislocated midshaft clavicle fractures, but complications related to the implant material requiring a second operation are frequent. Future prospective trials are needed to analyse the influence of various plate types and plate position on implant-related complications.

Keywords: Review, Plate fixation, Midshaft dislocated clavicle fractures, Complications

Introduction

Clavicle fractures in adults occur quite frequently; approximately 5% of all fractures concern the clavicle. The vast majority of fractures, approximately 80%, is located in the midshaft of the clavicle and half of these fractures are displaced [25, 27].

In the past, treatment of choice for most midshaft clavicle fractures was nonoperative with a sling or figure-of-eight bandage [24, 30]. Reported nonunion rates following surgical fixation of clavicle fractures were initially higher than those reported following nonoperative treatment [24, 30]. More recent studies, however, suggest higher complication and nonunion rates of up to 15% following nonoperative treatment, in particular for patients with displaced midshaft clavicle fractures (DMCF) [6, 12, 17, 22, 34, 39]. In addition, these patients are at high risk of residual pain, disappointing cosmesis and shoulder dysfunction [6, 12, 22, 39].

A regularly used surgical treatment option for DMCF is plate fixation. An advantage of plate fixation is the immediate stability it provides which enables early postoperative mobilization [13, 23, 24]. Several types of plates and fixation methods have been previously described; these include (precontoured) dynamic compression plates (DCP), tubular plates or reconstruction plates [13, 23]. Although high success rates of plate fixation of displaced clavicle fractures have been shown, reported complications of plate fixation include implant failure, (deep) infections, implant prominence, poor cosmesis, nonunions and refracture as a result of removal of the plate [4, 8, 9].The study quality and scientific levels of evidence at which complications are presented, however, vary greatly in literature. Different reviews are performed on clavicle fractures, but none of these reviews specifically address the complications of plate fixation for dislocated midshaft clavicular fractures.

This systematic review aims at answering the following questions: (1) What is the incidence of minor and major complications after surgical plate fixation of acute DMCF? (2) What is the value of reported complications in terms of the scientific level of evidence at which they are presented? (3) What are the frequency and severity of the long-term consequences of major complications after plate fixation? (4) what conclusions may be drawn from these findings and how may it influence treatment of midshaft clavicle fractures?

Methods

Search strategy

On 4th April 2011, a computer-aided search using EMBASE and PUBMED/MEDLINE was conducted using the first two phases of the optimal search strategy from the Cochrane Handbook (http://www.cochrane-handbook.com). This strategy was combined with a subject specific search (“Appendix I”). Reference and citation tracking was used to complete the search database.

Inclusion criteria

Studies included for review reported complications after acute, displaced, midshaft clavicle fractures treated with plate fixation alone or in comparison to either treatment with intramedullary pin fixation and/or nonoperative treatment. Degree of fracture displacement had to be noted in the “Materials and methods” section for studies to be enrolled for further analysis. Studies in English, Dutch, German or French were assessed for inclusion. Case reports, biomechanical studies, papers describing a surgical technique and reviews were excluded from the database. Studies reporting on complications of the operative treatment of clavicle malunions, nonunions, open fractures, multiple fractures to the shoulder girdle, pathologic fractures, additional morbidity (i.e. floating shoulder) or fractures that had initial nonoperative treatment as starting point were also excluded.

Selection of studies

After the initial search strategy was performed, the remaining studies were screened for inclusion criteria based on their title/abstract by two researchers (FJGW, OAJvdM). Studies eligible for inclusion were additionally read completely for final inclusion. Finally, (prospective) trials without any notice of ethics committee consultation or approval were excluded from further assessment. Disagreement between the reviewers was resolved by discussion with another independent reviewer (RMH).

Quality assessment

Two quality assessment tools were used to assess the methodological quality of the final selection of studies. Assessment was performed without masking the source or authorship of trial reports. The two tools used were the level of evidence (LoE) rating according to the Oxford Centre of Evidence Based Medicine (http://www.cebm.net) and the modified version of the Cochrane Bone, Joint and Muscle Trauma Group’s former quality assessment tool (QAT, http://www.cochrane-handbook.com). Studies were first labeled according to their LoE (Level I: high evidence, Level II: moderate evidence, Level III: low evidence, Level IV: very low evidence). Secondly, the QAT was used to assess the research quality into more detail. The QAT is a tool that scores an article on 11 items: 7 items on internal validity and 4 items on external validity. Disagreement between the reviewers about the quality assessment was again resolved by discussion with another independent reviewer (RM).

Data extraction and analysis

Included studies were ranked according to their levels of evidence. The study characteristics, including design, type and position of plate used for fixation and follow-up time were also taken into account.

Complications following the plate fixation of DMCF were identified and broken down into the following categories, if possible; bone-healing problems (nonunion and symptomatic malunion), infection (deep or wound), implant related problems (breakage, mechanical failure, irritation, angulation), plate debridement, removal or revision, neurovascular problems (transient or persistent brachial plexus symptoms, regional pain syndrome), refracture after plate removal and other complications. These categories were further subcategorized into two groups; major and minor complications. Major complications are characterized as a complication that needs another surgery to either remove or revise the plate as a result of the complication presented. Major complications are: nonunions, symptomatic malunion, deep infections, mechanical failure, irritation, breakage of the implant, angulation and refracture after plate removal. Minor complications are characterized as a complication that does not need another surgery and where a small intervention (i.e. oral antibiotics) may suffice. Minor complications are: wound infection and neurovascular problems. To avoid misinterpretation, the definitions of various complications stated in the reviewed studies were used in our analysis as much as possible.

Results

A total of 196 articles were identified, of which 27 were potentially relevant after screening the title and abstract and excluding doubles (Fig. 1). Full text screening resulted in 11 studies eligible for final quality assessment. There was no disagreement between the reviewers about the selection of the 11 final articles.

Fig. 1.

Fig. 1

Flowchart demonstrating the article search and appraisal process. Search was conducted on April 6th 2011. Asterisk excluded were one case report [29] and two studies in which there was no clear distinction made between postoperative complications after acute fractures and nonunions [9, 14]. Seven studies included complicated fractures and made no distinction with uncomplicated fractures when describing complications [3, 8, 15, 1820, 32]. One study was a surgical technique paper [2], one study only reported outcomes and no complications [28], two studies had no clear definition of indication for surgery [1, 38] and, finally, two studies included different kinds of clavicle fractures (pathological, distal and nonunions) [11, 26]

Level of evidence

Three studies were designed as randomized controlled trials and marked with the highest LoE (Table 1) [5, 10, 33]. All three studies report considerable wound infection rates (5–22%) [5, 10, 33]. In addition, Shen et al. [33] report high nonunion rates of 13% in comparison to Ferran et al. [10] and the COTS [5], 0 and 3%, respectively. They [5, 10], on the other hand, report significant rates of implant-related problems requiring plate debridement, removal or even revision fixation, 10 and 53%.

Table 1.

Studies graded level of evidence I according to the Oxford Centre of Evidence Based Medicine (http://www.cebm.net)

COTS [5] Ferran et al. [10] Shen et al. [33]
Study characteristics
Design RCT; plating versus nonoperative treatment RCT; plating versus pin fixation RCT; ‘normal’ plating versus 3D-aided plating
Number of plate fixations N = 62 N = 15 N = 133
Type of plate (times used) LCDCP (44), reconstruction plate (15), precontoured plate(4), Other (4) LCDCP (15) Reconstruction plate; ‘Normal’ plating (66), 3D-aided plating 67)
Plate positioning Superior Superior Superior
Mean time to follow-up in months (range) 12 12 (5–28) 12
Complication rate
Bone-healing problem
 Nonunion 2 (3%) 0 (0%) 8 (12%) versus 1 (1%)
 (Symptomatic) Malunion 0 n/a  
Infection
 Wound 3 (5%) 3 (20%) 12 (19%) versus 2 (3%)
 Deep n/a n/a n/a
Implant breakage/failure/irritation
 Irritation 6 (10%) 3 (20%) n/a
 Mechanical failure n/a n/a n/a
Plate debridement/removal/revision 6 (10%) 8a (53%) n/a
Neurovascular problems
 Brachial plexus symptoms 8 (13%) 1 (7%) n/a
 Regional pain syndrome 0 1 (7%) n/a
Refracture after plate removal 0 n/a n/a
Other 4 (6%) n/a 0

RCT randomized controlled trial, LCDCP limited contact dynamic compression plate, 3D 3-dimensional, n/a not applicable (complication not mentioned in study)

aOne plate was removed because the patient was a high level athlete

One study was graded LoE II, being designed as prospective cohort study [16] and reported complications were mainly implant related (Table 2). A total of four studies were designed as retrospective cohort studies and therefore labeled as LoE III [7, 21, 35, 36]. Again the main complications reported in these four studies were implant-related problems (Table 3). Finally, three studies were assigned to LoE IV, all of them being retrospective case series [4, 31, 37]. The majority of complications again concerned the used implants (Table 4).

Table 2.

Studies graded level of evidence I according to the Oxford Centre of Evidence Based Medicine (http://www.cebm.net)

Kuhlshrestha et al. [16]
Study characteristics
Design Prospective cohort; plating versus nonoperative treatment
Number of plate fixations N = 45
Type of plate (times used) Reconstruction plate (45)
Plate positioning Superior (15), anterior inferior (30)
Mean time to follow-up in months (range) 12
Complication rate
Bone-healing problem
 Nonunion 0
 (Symptomatic) Malunion 2 (4%)
Infection
 Wound n/a
 Deep n/a
Implant breakage/failure/irritation
 Irritation 4 (9%)
 Mechanical failure n/a
Plate debridement/removal/revision 4 (9%)
Neurovascular problems
 Brachial plexus symptoms n/a
 Regional pain syndrome n/a
Refracture after plate removal 0
Other 4 (9%)

n/a not applicable (complication not mentioned in study)

Table 3.

Studies graded level of evidence III according to the Oxford Centre of Evidence Based Medicine (http://www.cebm.net)

Vanbeek et al. [36] Cho et al. [7] Liu et al. [21]
Study characteristics
Design Retrospective cohort study; noncontoured plating versus contoured plating Retrospective cohort study; reconstruction plating versus reconstruction locking plating Retrospective cohort study; plating versus pin fixation
Number of plate fixations N = 42 N = 41 N = 59
Type of plate (times used) Noncontoured (14); DCP (4), LCP (2), LCDCP (4), reconstruction plate (4), precontoured (28); locking clavicle plate (28) Precontoured; reconstruction plate (19), reconstruction LCP (22) Reconstruction LCP (59)
Plate positioning Superior Superior Superior
Mean time to follow-up in months (range) 12 13 (7–35) versus 12 (7–24) 12
Complication rate
Bone-healing problem
 Nonunion 0 versus 1 (4%) 0 6 (10%)
 (Symptomatic) Malunion n/a 0 2 (3%)
Infection
 Wound 0 versus 1 (4%) 0 6 (10%)
 Deep n/a 0  
Implant breakage/failure/irritation
 Irritation 9 (64%)a versus 9 (32%) 0 12 (20%)
 Mechanical failure n/a 0 4 (8%)
Plate debridement/removal/revision 3 (21%) versus 3 (11%) n/a 14 (24%)
Neurovascular problems
 Brachial plexus symptoms n/a n/a n/a
 Regional pain syndrome n/a 2 (11%) versus 1 (5%) n/a
Refracture after plate removal 0 versus 1 (4%) 0 n/a
Other 0 versus 2 (7%) 7 (39%) versus 5 (23%) n/a
  Thyagarajan et al. [35]
Study characteristics
Design Retrospective cohort study; plating versus pin fixation versus nonoperative treatment
Number of plate fixations N = 16
Type of plate (times used) LCDCP (16)
Plate positioning Superior
Mean time to follow-up in months (range) 6 (4–11)
Complication rate
Bone-healing problem
 Nonunion 1 (6%)
 (Symptomatic) Malunion n/a
Infection
 Wound 1 (6%)
 Deep 1 (6%)
Implant breakage/failure/irritation
 Irritation 2 (13%)
 Mechanical failure n/a
Plate debridement/removal/revision 2 (13%)
Neurovascular problems
 Brachial plexus symptoms 4 (25%)
 Regional pain syndrome 6 (38%)
 Refracture after plate removal n/a
 Other 1 (6%)

LCDCP limited contact dynamic compression plate, n/a not applicable (complication not mentioned in study)

aRemoved noncontoured plates included DCP (1), LCDCP (1) and reconstruction plate (1)

Table 4.

Studies graded level of evidence IV according to the Oxford Centre of Evidence Based Medicine (http://www.cebm.net)

  Russo et al. [31] Verborgt et al. [37] Böstman et al. [4]
Study characteristics
Design Retrospective case series Retrospective case series Retrospective case series
Number of plate fixations N = 43 N = 39 N = 103
Type of plate (times used) Mennen-plate Precontoured; reconstruction plate (?) LCDCP (?) DCP (57), reconstruction plate (46)
Plate positioning Superior Anterior

Anterior (57)

Superior (46)

Mean time to follow-up in months (range) 12 3 23 (6–53)
Complication rate
Bone-healing problem
 Nonunion 2 (5%) 2 (5%) 3 (3%)
 (Symptomatic) Malunion n/a n/a 12 (12%)
Infection
 Wound 0 4 (10%) 3 (3%)
 Deep 0 3 (8%) 5 (5%)
Implant breakage/failure/irritation
 Irritation 0 n/a n/a
 Mechanical failure 0 2 (5%) 16 (16%)
Plate debridement/removal/revision 13a (30%) 7 (18%) 14 (14%) + 54 (52%)b
Neurovascular problems
 Brachial plexus symptoms 10 (23%) 3 (8%) 2 (2%)
 Regional pain syndrome n/a n/a n/a
Refracture after plate removal n/a 2 (5%)c 1 (1%)
Other 2 (5%) n/a n/a

LCDCP low contact dynamic compression plate, DCP dynamic compression plate, n/a not applicable (complication not mentioned in study)

a11 patients requested removal of the plate for cosmetic reasons

b54 patients underwent routine plate removal

cRefractures both after LCDCP plates

A total of 10 of the 11 assessed studies reported the usage of superior position for plate fixation [4, 5, 7, 10, 16, 21, 31 33, 35, 36]. Anterior or anterior inferior plate positioning was analyzed in three studies [4, 16, 37]. The reconstruction plate and the low-contact dynamic compression plate (LCDCP) were the two most commonly used types for plate fixation.

Quality assessment

The majority of studies had well-defined in- and exclusion criteria, interventions and outcome measures. Adequate duration of follow-up was considered a minimum of 1 year which applied to most studies (Table 5). The study by the Canadian Orthopedic Trauma Society [5] was graded the strongest of selected studies and of highest scientific quality.

Table 5.

Quality assessment outcome of all analyzed studies according to the modified version of the Cochrane Bone, Joint and Muscle Trauma Group’s former quality assessment tool (QAT, http://www.cochrane-handbook.com)

Study Allocation concealment Intention- to-treat analysis Assessor blinding Comparable baseline characteristics Participant blinding Treatment provider blinding Care program comparability Defined in - and exclusion criteria
COTS et al. [29] 2 2 0 2 0 0 2 2
Kulshrestva et al. [32] 2 2 0 2 0 0 2 2
Ferran et al. [30] 2 2 0 2 0 0 2 2
Shen et al. [31] 2 2 2 2 2 0 0 1
Liu et al. [35] 0 0 0 2 0 0 2 2
Cho et al. [34] 0 0 0 1 0 0 2 1
Vanbeek et al. [33] 0 0 0 2 0 0 2 2
Russo et al. [37] 0 0 0 0 0 0 0 1
Bostman et al. [4] 0 0 0 0 0 0 0 2
Thyagarajan et al. [36] 0 0 0 2 0 0 0 2
Verborgt et al. [38] 0 0 0 0 0 0 0 1
Study Well-defined interventions Well-defined outcome measures Clinically useful diagnostic tests Adequate duration of follow-up QAT Score
COTS et al. [29] 2 2 2 2 18
Kulshrestva et al. [32] 2 2 1 2 17
Ferran et al. [30] 2 2 1 2 17
Shen et al. [31] 2 0 0 2 15
Liu et al. [35] 2 2 2 2 14
Cho et al. [34] 2 2 2 1 11
Vanbeek et al. [33] 1 2 2 0 11
Russo et al. [37] 2 2 2 2 9
Bostman et al. [4] 2 2 1 1 8
Thyagarajan et al. [36] 1 2 0 0 7
Verborgt et al. [38] 1 2 1 2 7

Bold values indicate that the higher the value, the better methodological quality and least chance of bias, with a maximum score of 24

QAT quality assessment tool

Discussion

The goal of this systematic review was to document the (prevalence of) complications after plate fixation of DMCF. To obtain the best available evidence, relevant studies were scored on scientific methodology and the LoE they provide. We attempted to find an answer to the following questions; what is the incidence of minor and major complications after surgical plate fixation of acute DMCF? What is the value of reported complications in terms of the scientific level of evidence at which they are presented? What are the frequency and severity of the long-term consequences of major complications after plate fixation? And what conclusions may be drawn from these findings and how may it influence treatment of midshaft clavicle fractures? In response to our second question, we found that only three of the eligible studies provided the highest LoE [5, 10, 33]. Two of these studies included a sample-size calculation [5, 10]. One study was a prospective cohort study but scored very well on quality assessment [16]. Based on their quality of methodology, we believe the studies by the COTS [5] and Kulshrestha et al. [16] to provide the best available evidence.

In search of an answer to our first question, we found nonunion rates were no higher than 10% in all analysed studies but one [4, 5, 7, 10, 16, 21, 31, 33, 35, 36]. If reported on infection rates, both wound and deep infections were also below 10% in all but two studies [4, 5, 7, 10, 21, 31, 33, 35, 36]. The vast majority of these infections were wound infections, reportedly treated successfully with oral antibiotics. Neurovascular complications included brachial plexus symptoms and regional pain syndromes and ranged in prevalence from 0 to 38%, all reportedly were transient [4, 5, 7, 10, 31, 35, 37]. Based on these figures, the incidence of minor complications (wound infections and neurovascular problems) is low.

Regardless of the LoE provided, the vast majority of complications seem to be implant related, with irritation or failure of the plate being consistently reported on in almost every study, on average ranging from 9 to 64% [5, 10, 16, 21, 33, 36].This is a point of concern, considering that, even in the better designed studies, a second operation with plate debridement, removal or revision was required at best in one out of every ten patients treated, in some studies even up to one out of every two patients [4, 5, 10, 16, 21, 31, 35, 36]. There is a relatively small risk of refracture after plate removal, between 1 and 5% [4, 31, 36]. However, it must be noted that only three of the 11 analyzed studies report on these numbers. In one study, two refractures after plate removal were reported [31]. This study compared LCDCP plates and reconstruction plates, and both refractures occurred after removal of LCDCP plates. Another study had a refracture after removal of a precountoured plate; the Locking Clavicle Plate [33]. The last refracture was reported after removal of an eight-screw dynamic compression plate [4]. The numbers presented above provide us with an answer to our third question. We conclude, based on the figures of plate debridement, removal or revision, that the incidence of major complications is high, ranging up to 64%. Major complications require another surgery, but this surgery does treat the condition and complication and no long-term consequences are expected portraying low severity.

In light of our last question, this review points out that implant-related problems occur frequently. It is possible that the positioning of the plate anteriorly can decrease the number of complications. However, only one study mentioned that they felt that plate position initially influenced the outcome and complications of their treatment [16]. Additionally, plate type and pre-contouring to the anatomic shape of the clavicle may also have an influence. However, the current numbers available are too small and study designs to different to make any assumptions.

Although not optimal with regards to methodological qualities, we included retrospective case series in our analysis. In some studies, the complications were well documented and the reported complication rates were too high to ignore. In particular in the studies by Russo et al. [31] and Bostman et al. [4], the authors gave detailed descriptions of encountered complications and the complication rates are high.

There are some limitations to this review. Proceedings from annual meetings (conferences) were not included in this review. Only PUBMED, EMBASE and the Cochrane databases were used for search. Therefore, some valuable information might be lost. However, at proceedings mostly interim analyses are reported and these results might differ from the final results. PUBMED and EMBASE are the largest medical databases. We thoroughly screened the studies and submitted them to a quality assessment which results in an evidence-based conclusion to what extend complications can be attributed to plate fixation. Because of the different study designs and characteristics, data could not be pooled and the data were summarized separately per study. We used the definitions of complications set forth in the analyzed studies to divide the complications into six main categories. However, different authors may have used different definitions for complications i.e. deep, superficial and wound infections. In the future, improvements can be made concerning definitions of complications. Actual complication rates might be higher than many authors report, based on distinctions made between minor and major complications and overlap in definitions (e.g. failure or infection may result in removal, debridement or revision).

Based on the overall low numbers of reported nonunion and symptomatic malunion, we conclude and answer our final question that plate fixation is a safe treatment option for DMCF. However, this review also points out that complications related to the implant material are frequent often requiring removal, revision or debridement of the plate. The quantity of high LoE studies to support this is limited. More prospective trials with well-defined complications as outcome measurements are needed to make more specific recommendations with regard to optimum plate position, the type of plate and possible postoperative complications regarding plate fixation for DMCF.

Acknowledgments

This work was not supported directly by an outside funding or grant. However, Dr. Millett is a consultant and receives payments from Arthrex and has stock options in Game Ready. In addition, Dr. Van der Meijden’s research position was supported by Arthrex. This research was supported by The Steadman Philippon Research Institute which is a 501(c)3 nonprofit institution supported financially by private donations and corporate support from the following entities: Smith and Nephew Endoscopy, Arthrex, Arthrocare, Siemens, OrthoRehab, Ossur Americas and ConmedLinvatec.

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Appendix I

PUBMED/MEDLINE search string

(((((((((midshaft[Title/Abstract]) OR shaft[Title/Abstract]) OR shafts[Title/Abstract]) OR mid[Title/Abstract]) OR midclavicle[Title/Abstract]) OR middle[Title/Abstract]) OR mid-third[Title/Abstract]) OR diaphysis[Title/Abstract]) OR diaphyseal[Title/Abstract])

AND

(((((((clavicular[Title/Abstract]) OR clavicula[Title/Abstract]) OR claviculae[Title/Abstract]) OR clavicle[Title/Abstract]) OR clavicles[Title/Abstract]) OR collarbone[Title/Abstract]) OR collarbones[Title/Abstract])

AND

(((((plating[Title/Abstract])OR plate[Title/Abstract]) OR plate-osteosynthesis[Title/Abstract]) OR plates[Title/Abstract]) OR plate-fixation[Title/Abstract])

AND

(((fractures[Title/Abstract]) OR fracture[Title/Abstract]) OR fractured[Title/Abstract])

Embase search string

midshaft:ab,ti OR shaft:ab,ti OR shafts:ab,ti OR mid:ab,ti ORmidclavicle:ab,ti OR middle:ab,ti OR third:ab,ti OR diaphysis:ab,ti OR diaphysial;ab,ti AND (clavicular:ab,ti OR clavicula:ab,ti OR claviculae:ab,ti OR clavicle:ab,ti OR clavicles:ab,ti OR collarbone:ab,ti OR collarbones:ab,ti) AND (plating;ab,ti OR plate:ab,ti OR plate-osteosynthesis:ab,ti OR plates:ab,ti OR plate-fixation:ab,ti) AND (fractures:ab,ti OR fracture:ab,ti OR fractured:ab,ti) AND [embase]/lim

Contributor Information

Frans-Jasper G. Wijdicks, Phone: +1-31-651957012, Email: fjgwijdicks@gmail.com

Olivier A. J. Van der Meijden, Email: olivier@sprivail.org

Peter J. Millett, Email: drmillett@thesteadmanclinic.com

Egbert J. M. M. Verleisdonk, Email: ejverleisdonk@diakhuis.nl

R. Marijn Houwert, Email: marijnhouwert@hotmail.com.

References

  • 1.Ali Khan MA, Lucas HK. Plating of fractures of the middle third of the clavicle. Injury. 1978;9(4):263–267. doi: 10.1016/S0020-1383(77)80041-7. [DOI] [PubMed] [Google Scholar]
  • 2.Altamimi SA, McKee MD, Canadian Orthopaedic Trauma Society Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. Surgical technique. J Bone Joint Surg Am. 2008;90(Suppl 2 Pt 1):1–8. doi: 10.2106/JBJS.G.01336. [DOI] [PubMed] [Google Scholar]
  • 3.Böhme J, Bonk A, Bacher GO, Wilharm A, Hoffmann R, Josten C. Current treatment concepts for mid-shaft fractures of the clavicle—results of a prospective multicentre study. Z Orthop Unfall. 2011;149(1):68–76. doi: 10.1055/s-0030-1250334. [DOI] [PubMed] [Google Scholar]
  • 4.Bostman O, Manninen M, Pihlajamaki H. Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma. 1997;43:778–783. doi: 10.1097/00005373-199711000-00008. [DOI] [PubMed] [Google Scholar]
  • 5.Canadian Orthopaedic Trauma Society Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am. 2007;89(1):1–10. doi: 10.2106/JBJS.F.00020. [DOI] [PubMed] [Google Scholar]
  • 6.Chan KY, Jupiter JB, Leffert RD, et al. Clavicle malunion. J Shoulder Elbow Surg. 1999;8:287–290. doi: 10.1016/S1058-2746(99)90146-5. [DOI] [PubMed] [Google Scholar]
  • 7.Cho CH, Song KS, Min BW, Bae KC, Lee KJ. Operative treatment of clavicle midshaft fractures: comparison between reconstruction plate and reconstruction locking compression plate. Clin Orthop Surg. 2010;2(3):154–159. doi: 10.4055/cios.2010.2.3.154. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Collinge C, Devinney S, Herscovici D. Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle. J Orthop Trauma. 2006;20:680–686. doi: 10.1097/01.bot.0000249434.57571.29. [DOI] [PubMed] [Google Scholar]
  • 9.Coupe BD, Wimhurst JA, Indar R. A new approach for plate fixation of midshaft clavicular fractures. Injury. 2005;36:1166–1171. doi: 10.1016/j.injury.2005.03.007. [DOI] [PubMed] [Google Scholar]
  • 10.Ferran NA, Hodgson P, Vannet N, Williams R, Evans RO. Locked intramedullary fixation vs. plating for displaced and shortened mid-shaftclavicle fractures: a randomized clinical trial. J Shoulder Elbow Surg. 2010;19(6):783–789. doi: 10.1016/j.jse.2010.05.002. [DOI] [PubMed] [Google Scholar]
  • 11.Fuchs M, Losch A, Stürmer KM. Surgical treatment of fractures of the clavicle—indication, surgical technique and results. Zentralbl Chir. 2002;127(6):479–484. doi: 10.1055/s-2002-32618. [DOI] [PubMed] [Google Scholar]
  • 12.Hill JM, Mcguire MH, Crosby LA. Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br. 1997;79:537–539. doi: 10.1302/0301-620X.79B4.7529. [DOI] [PubMed] [Google Scholar]
  • 13.Kabak S, Halici M, Tuncel M, Avsarogullari L, Karaoglu S. Treatment of mid-clavicular nonunion: comparison of dynamic compression plating and low-contact dynamic compression plating techniques. J Shoulder Elbow Surg. 2004;13:396–403. doi: 10.1016/j.jse.2004.01.033. [DOI] [PubMed] [Google Scholar]
  • 14.Kloen P, Werner CM, Stufkens SA, Helfet DL. Anteroinferior plating of midshaft clavicle nonunions and fractures. Oper Orthop Traumatol. 2009;21(2):170–179. doi: 10.1007/s00064-009-1705-8. [DOI] [PubMed] [Google Scholar]
  • 15.Kulshrestha V. Primary plating of displaced mid-shaft clavicular fractures. Med J Armed Forces India. 2008;64(3):208–211. doi: 10.1016/S0377-1237(08)80093-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Kulshrestha V, Roy T, Audige L. Operative versus nonoperative management of displaced midshaft clavicle fractures: a prospective cohort study. J OrthopTrauma. 2011;25(1):31–38. doi: 10.1097/BOT.0b013e3181d8290e. [DOI] [PubMed] [Google Scholar]
  • 17.Lazarides S, Zawropoulos G. Conservative treatment of fractures at the middle third of the clavicle: the relevance of shortening and clinical outcome. J Shoulder Elbow Surg. 2006;15:191–194. doi: 10.1016/j.jse.2005.08.007. [DOI] [PubMed] [Google Scholar]
  • 18.Lee YS, Lin CC, Huang CR, Chen CN, Liao WY. Operative treatment of midclavicular fractures in 62 elderly patients: Knowles pin versus plate. Orthopedics. 2007;30(11):959–964. doi: 10.3928/01477447-20071101-13. [DOI] [PubMed] [Google Scholar]
  • 19.Lee YS, Huang HL, Lo TY, Hsieh YF, Huang CR. Surgical treatment of midclavicular fractures: a prospective comparison of Knowles pinning and plate fixation. Int Orthop. 2008;32(4):541–545. doi: 10.1007/s00264-007-0352-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Liu PC, Hsieh CH, Chen JC, Lu CC, Chuo CY, Chien SH. Infection after surgical reconstruction of a clavicle fracture using a reconstruction plate: a report of seven cases. Kaohsiung J Med Sci. 2008;24(1):45–49. doi: 10.1016/S1607-551X(08)70073-1. [DOI] [PubMed] [Google Scholar]
  • 21.Liu HH, Chang CH, Chia WT, Chen CH, Tarng YW, Wong CY. Comparison of plates versus intramedullary nails for fixation of displaced midshaft clavicular fractures. J Trauma. 2010;69(6):E82–E87. doi: 10.1097/TA.0b013e3181e03d81. [DOI] [PubMed] [Google Scholar]
  • 22.McKee MD, Wild LM, Schemitsch EH. Midshaft malunions of the clavicle. J Bone Joint Surg Am. 2003;85-A:790–797. doi: 10.2106/00004623-200305000-00003. [DOI] [PubMed] [Google Scholar]
  • 23.Mullaji AB, Jupiter JB. Low-contact dynamic compression plating of the clavicle. Injury. 1994;25:41–45. doi: 10.1016/0020-1383(94)90183-X. [DOI] [PubMed] [Google Scholar]
  • 24.Neer CSII. Nonunion of the clavicle. JAMA. 1960;172:1006–1011. doi: 10.1001/jama.1960.03020100014003. [DOI] [PubMed] [Google Scholar]
  • 25.Nordqvist A, Petersson C. The incidence of fractures of the clavicle. Clin Orthop Relat Res. 1994;300:127–132. [PubMed] [Google Scholar]
  • 26.Poigenfürst J, Reiler T, Fischer W. Plating of fresh clavicular fractures. Experience with 60 operations. Unfallchirurgie. 1988;14(1):26–37. [PubMed] [Google Scholar]
  • 27.Postacchini F, Gumina S, De Santis P, et al. Epidemiology of clavicle fractures. J Shoulder Elbow Surg. 2002;11:452–456. doi: 10.1067/mse.2002.126613. [DOI] [PubMed] [Google Scholar]
  • 28.Potter JM, Jones C, Wild LM, Schemitsch EH, McKee MD. Does delay matter? The restoration of objectively measured shoulder strength and patient-oriented outcome after immediate fixation versus delayed reconstruction of displaced midshaft fractures of the clavicle. J Shoulder Elbow Surg. 2007;16(5):514–518. doi: 10.1016/j.jse.2007.01.001. [DOI] [PubMed] [Google Scholar]
  • 29.Rabe SB, Oliver GD. Clavicular fracture in a collegiate football player: a case report of rapid return to play. J Athl Train. 2011;46(1):107–111. doi: 10.4085/1062-6050-46.1.107. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Rowe CR. An atlas of anatomy and treatment of midclavicular fractures. Clin Orthop Relat Res. 1968;58:29–42. doi: 10.1097/00003086-196805000-00006. [DOI] [PubMed] [Google Scholar]
  • 31.Russo R, Visconti V, Lorini S, Lombardi LV. Displaced comminuted midshaft clavicle fractures: use of Mennen plate fixation system. J Trauma. 2007;63(4):951–954. doi: 10.1097/TA.0b013e31814549e7. [DOI] [PubMed] [Google Scholar]
  • 32.Shen WJ, Liu TJ, Shen YS. Plate fixation of fresh displaced midshaft clavicle fractures. Injury. 1999;30(7):497–500. doi: 10.1016/S0020-1383(99)00140-0. [DOI] [PubMed] [Google Scholar]
  • 33.Shen JW, Tong PJ, Qu HB. A three-dimensional reconstruction plate for displaced midshaft fractures of the clavicle. J Bone Joint Surg Br. 2008;90(11):1495–1498. doi: 10.1302/0301-620X.90B11.21096. [DOI] [PubMed] [Google Scholar]
  • 34.Smekal V, Oberladstaetter J, Struve P, et al. Shaft fractures of the clavicle: current concepts. Arch Orthop Trauma Surg. 2009;129:807–815. doi: 10.1007/s00402-008-0775-7. [DOI] [PubMed] [Google Scholar]
  • 35.Thyagarajan DS, Day M, Dent C, Williams R, Evans R. Treatment of mid-shaftclavicle fractures: a comparative study. Int J Shoulder Surg. 2009;3(2):23–27. doi: 10.4103/0973-6042.57895. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Vanbeek C, Boselli KJ, Cadet ER, Ahmad CS, Levine WN. Precontoured plating of clavicle fractures: decreased hardware-related complications? Clin Orthop Relat Res. 2011;469(12):3337–3343. doi: 10.1007/s11999-011-1868-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Verborgt O, Pittoors K, Van Glabbeek F, Declercq G, Nuyts R, Somville J. Plate fixation of middle-third fractures of the clavicle in the semi-professional athlete. Acta Orthop Belg. 2005;71(1):17–21. [PubMed] [Google Scholar]
  • 38.Wang K, Dowrick A, Choi J, Rahim R, Edwards E. Post-operative numbness and patient satisfaction following plate fixation of clavicular fractures. Injury. 2010;41(7):939–942. doi: 10.1016/j.injury.2009.12.003. [DOI] [PubMed] [Google Scholar]
  • 39.Zlowodzki M, Zelle BA, Cole PA, et al. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma. 2005;19:504–507. doi: 10.1097/01.bot.0000172287.44278.ef. [DOI] [PubMed] [Google Scholar]

Articles from Archives of Orthopaedic and Trauma Surgery are provided here courtesy of Springer

RESOURCES