Skip to main content
Annals of The Royal College of Surgeons of England logoLink to Annals of The Royal College of Surgeons of England
. 2011 May;93(4):326. doi: 10.1308/003588411X570909g

A simple technique to avoid blockage of the suction system in laparoscopic procedures

Hany Balamoun 1, Samer Doughan 1, Mansoor Akhtar 1
PMCID: PMC3363093  PMID: 21944809

A tonsil swab is inserted through a 10–12mm port and the suction tip is placed over the swab to get rid of any fluid. In such a technique, the swab will act as a barrier and the fluid can be sucked in all areas of the abdominal cavity without allowing omentum or fat to cause blockage of the suction tip (Fig 1).

Figure 1.

Figure 1

The area is dry after suction through the tonsil swab.


Articles from Annals of The Royal College of Surgeons of England are provided here courtesy of The Royal College of Surgeons of England