TABLE I.

Experimental parameters for the working fluids used in this study.

Experimental parameter Pure water in vitro blood
Height × width × length of the microchannel before bifurcation 160 ± 1 μm × 50 ± 1 μm × 40mm 160 ± 1 μm × 50 ± 1 μm × 40mm
Flow rate 3.0 × 10−12 m3/s 3.3 × 10−12 m3/s
Mean velocity in the inlet channel 0.38 mm/s 0.41 mm/s
Particle/RBC diameter at rest 1 μm  ≈ 8 μm
Particle/RBC concentration 0.1% 14%
Dextran 40 concentration ≈ 9%
Viscosity of the suspending fluid 7.1 × 10−4 Pa·s 4.5 × 10−3 Pa·s
Temperature 37°C 37°C
Magnification (M) 32× 32×
Numerical aperture (NA) 0.75 0.75
λex excitation wavelength 532 nm 532 nm
Refractive index of PDMS (n) 1.4 1.4
Optical slice thickness (OST)a 6.94 μm 6.94 μm
Capture image rate 100 frames/s 100 frames/s
a

A detailed description to calculate the OST can be found in Lima et al.10