Skip to main content
Clinical Orthopaedics and Related Research logoLink to Clinical Orthopaedics and Related Research
. 2012 Feb 11;470(8):2185–2192. doi: 10.1007/s11999-012-2277-8

Are Shoulders with A Reverse Shoulder Prosthesis Strong Enough? A Pilot Study

Tjarco D W Alta 1,, H E J Veeger 2,3, Thomas W J Janssen 2,4, W Jaap Willems 1
PMCID: PMC3392387  PMID: 22328239

Abstract

Background

It has been suggested that limited active ROM of reverse shoulder prostheses relates to lack of strength. However, the postoperative strength has not been quantified.

Questions/purposes

We therefore measured joint torques in patients with reverse shoulder prostheses and correlated torques with functional scores.

Methods

We recruited 33 patients (age, 72 ± 8 years) with a reverse prosthesis (37 shoulders, 21 primary and 16 revisions). We obtained Constant-Murley, DASH, and Simple Shoulder Test ([D]SST) scores, and performed two isokinetic protocols (abduction/adduction and external/internal rotation) at 60° per second. Minimum followup was 4 months (average, 23 months; range, 4–63 months).

Results

Twenty-three patients (24 shoulders; 13 primaries, 11 revisions) were able to perform at least one of the defined tasks. Mean abduction and adduction torques were 15 Nm ± 7 Nm and 16 Nm ± 10 Nm (19%–78% of normal shoulders). External and internal rotation tasks could be performed by only 13 patients (14 shoulders; nine primary, five revisions) generating 9 Nm ± 4 Nm and 8 Nm ± 3 Nm, respectively (13%–71% of normal shoulders). We found moderate correlations between Constant-Murley, DASH and (D)SST (D = Dutch translation) scores and abduction and external rotation.

Conclusions

Patients with a reverse prosthesis had reduced strength when compared with normal values reported in the literature (only 65% of patients could perform the protocol). This effect was greatest for external rotation and might explain clinical outcomes with which a moderately strong relationship was observed. Our observations suggest limited strength is a major factor in reduced ROM.

Introduction

The reverse shoulder prosthesis is one surgical option for treatment of cuff tear arthropathy and shoulder pseudoparalysis resulting from a massive cuff tear, severe fractures, prosthetic revision, and tumor surgery [5]. Owing to the mechanical advantage of a medialized center of rotation, the reverse shoulder prosthesis offers a potentially valuable surgical option and has become an alternative in situations in which the rotator cuff and/or the proximal humerus are destroyed or absent [5], with a satisfying reduction of pain after surgery [12, 31].

However, because of the wide variation in published values for active elevation after reverse shoulder replacement (ranging from 88° to 138° [3, 36]), the degree to which this prosthesis restores arm strength is not fully defined. Bergmann et al. previously found a better passive than active ROM [3] and presumed that the limited glenohumeral motion of the reverse prosthesis resulted from a lack of joint torque generation rather than a structural limitation caused by the prosthetic design.

Shoulder strength mostly has been evaluated using subjective methods such as traditional manual muscle testing and handheld dynamometry, which mainly focus on isometric muscle strength. The strength measure in the Constant-Murley score [8, 9] is also isometric. Because most functional activities are dynamic, evaluating isokinetic shoulder strength may be more appropriate when relating strength to functional performance and clinical outcome. However, data for isokinetic strength measurements around the shoulder are available only for normal healthy subjects [7], patients after open fixation of glenoid rim fractures [33], open [1, 10] and arthroscopic anterior stabilization [15, 21], rotator cuff surgery [4, 11, 14, 34, 43], with adhesive capsulitis [26, 27, 41], subacromial impingement [16, 24, 30], and pectoralis major muscle rupture [17], but not for patients with a reverse shoulder prosthesis.

Our objective was to perform a pilot study to measure isometric shoulder strength in patients who underwent either a primary or revision reverse shoulder replacement. We asked the following questions: (1) what joint torques can patients with a reverse shoulder prosthesis produce isokinetically, and (2) does this force-generating capacity correlate with functional scores?

Materials and Methods

Between May 2000 and September 2007, we treated 45 patients (49 shoulders) with a reverse shoulder prosthesis (Tornier®; Edina, MN, USA). Of these, 33 patients (19 women and 14 men), volunteered to participate in this study. Ten patients had surgery on the left side, 19 on the right side, and four on both sides (total of 37 shoulders). In 21 patients, the indication for the reverse prosthesis was cuff tear arthropathy, and in 16 patients the indication was revision after a failed primary placed hemiprosthesis or total shoulder prosthesis. The average time between surgery and measurement was 23 ± 14 months (range, 4–63 months). Mean age of the patients was 72 ± 8 years (range, 58–85 years). The minimum clinical followup was 4 months (mean, 23 months; range, 4–63 months). The institutional ethics committee approved the research protocol and all patients gave their written informed consent before the experiment.

All patients underwent surgery under general anesthesia with an interscalene nerve block in the beach-chair position. We used a standard deltopectoral approach in all patients. All glenoid components had been placed inferior on the glenoid surface with no inferior or superior inclination. Thirty patients had a 36-mm component implanted and seven had a 42-mm sphere diameter. The humeral components had all been placed in 10° to 20° retroversion, and in 32 patients, the teres minor and subscapularis muscles were still intact.

Postoperative management was the same for all patients, consisting of a sling and passive ROM exercises for 6 weeks. After 6 weeks, active assisted ROM exercises were started and at 3 months, strengthening exercises were added to the rehabilitation program.

Shoulder strength was measured with an isokinetic dynamometer, which provides constant velocity with accommodating resistance throughout a joint’s ROM. This resistance is provided using an electric or hydraulic servo-controlled mechanism at a user-defined constant velocity [13]. Two isokinetic protocols were performed to measure the strength of the subjects’ shoulder muscles on the surgically treated side using the Biodex System 3 Pro dynamometer (Biodex Medical Systems, New York, NY, USA). These protocols consisted of an abduction and adduction task and an external and internal rotation task with the arm in 60° abduction in a sitting position with securing bands around the subject’s chest and pelvis. For the abduction and adduction task, the chair was rotated 75° around the vertical axis with the dynamometer in neutral position and 10° tilted. For the external and internal rotation task, the chair was in the neutral position with the dynamometer rotated 20° and 50° tilted. After one session of the abduction and adduction or the external and internal rotation task, the subject had a 60-second recovery time after which the same task was repeated. All tasks were repeated five times at 60° per second with a minimum standard threshold of 15° per second to start the measurements defined by the Biodex System. For each motion, the average maximal torque (Nm) was determined over the two sessions. The subjects were instructed and encouraged to reach the highest possible force level during these tasks. Negative axial rotation was defined as external rotation and positive axial rotation as internal rotation.

Codine et al. [7] reported a systematic review of the literature on isokinetic strength of the shoulder until 2005. We used PubMed to identify other articles providing data for normal shoulder torque values from 2005 and onward [2, 20, 37, 42]. From those studies we took the abduction-adduction and/or external-internal rotation torque values for 60° per second or less and combined those to make comparison possible with our obtained data (Table 1).

Table 1.

Maximum generated force in Nm for our data compared with the literature at similar or lower velocities

Study Subject Mean age (years) Dominance or side Velocity Abduction Adduction External rotation Internal rotation
Ambrosio et al. [2] M and F wheelchair users 43 60°/second 50.0 42.5 28.2 32.3
Codine et al. [6] M volunteers 26 D 60°/second 39.8 56.4
ND 42.7 56.2
M runners 23 D 60°/second 44.6 57.2
ND 45.8 54.7
M tennis players 26 D 60°/second 39.0 57.3
ND 40.1 54.0
M baseball players 20 D 60°/second 39.9 65.3
ND 39.8 55.5
Greenfield et al. [19] M and F 25 60°/second 14.1 15.4
Harbo et al. [20] M volunteers 53 60°/second 59.5 83.1
F volunteers 52 60°/second 37.4 45.7
Ivey et al. [22] M 36 60°/second 37.5 61.0 21.8 33.2
F 26 60°/second 19.5 34.2 13.0 17.9
Sirota et al. [35] M baseball players 24 D 60°/second 48.8 51.6
ND 44.2 52.3
Stickley et al. [37] F volleyball athletes 13 60°/second 16.8 22.3
Tis and Maxwell [39] F 25 D 60°/second 24.7 23.3
ND 24.7 21.2
Verney et al. [42] M volunteers 73 60°/second 46.0
30°/second 50.0
McMaster et al. [28, 29] M water polo players 26 Right 30°/second 51.8 99.1 38.2 65.9
Left 49.4 92.7 34.8 57.8
M swimming athletes 20 Right 30°/second 48.1 99.1 33.7 66.8
Left 48.6 102.2 31.8 55.9
M volunteers 22 Right 30°/second 35.3 54.0 29.1 39.9
Left 38.2 52.7 28.1 36.8
Otis et al. [32] M 26 D 48°/second 49.6 26.6 42.2
ND 46.4 26.6 38.0
Current study M and F reverse shoulder prosthesis 72 60°/second 15.2 16.1 9.3 8.2

M = male; F = female; D = dominant; ND = nondominant.

For clinical evaluation, we obtained preoperative and postoperative (absolute and relative) Constant-Murley scores [8, 9], postoperative DASH score [23], and the (D)SST [23, 40]. The absolute Constant-Murley score assesses the overall shoulder function and has a maximum score of 100 points. The relative Constant-Murley score is corrected for the age- and sex-related decline in force-generating capacity [46]. It is expressed as a percentage of the respective reference values. The DASH is a 30-item questionnaire that evaluates functional disability in everyday activities, work, and sports. It includes symptoms, physical, social, and psychological function. A DASH score of 0 indicates good shoulder function, or no disability, and the maximum score of 100 indicates no function. The (D)SST is a questionnaire consisting of 13 yes or no questions including subjective items and items that require patients to complete a physical exercise. It evaluates shoulder function in daily activities and a maximum score of 13 indicates good shoulder function.

We used a t-test to determine the difference in mean maximum generated torque at 60° per second between primary and revision cases. For this same group, the effect size was determined by calculating the Cohen’s d. The relationship between the clinical outcome scores (Constant-Murley, DASH, and [D]SST) and strength data was evaluated on the basis of a Pearson product-moment correlation.

Results

Only 23 patients (24 shoulders; 13 primary and 11 revisions) were able to generate sufficient velocity to perform the test, resulting in a mean abduction torque of 15.2 Nm ± 6.6 Nm for the whole group with no substantially better value for the primary prostheses compared with the revisions (Table 2). For the external and internal rotation torques, these values varied between 13% and 71%. We found similar torque values for adduction also with no major difference between primary and revision cases. The external and internal rotation tasks could be performed by only 13 patients (14 shoulders; nine primaries, five revisions). Mean external rotation torque was 9.3 Nm ± 4.4 Nm for the whole group with no major differences between the primary and revision groups. Internal rotation force tended to be higher (p = 0.07) for primary prostheses with a torque of 8.2 Nm ± 2.6 Nm for the whole group (Table 2). Compared with normal healthy subjects (Table 1), patients with a reverse prosthesis who could generate sufficient force to perform the tasks had abduction and adduction torques of 19% to 78% of those of a normal shoulder at a velocity of 60° per second.

Table 2.

Mean maximum generated force (Nm) and SD at 60° per second for the whole group

Maximum torque at 60° per second All shoulders (N = 24) Primary (N = 13) Revision (N = 11) p value primary versus revision Cohen’s d primary versus revision
Abduction 15.2 ± 6.6 16.3 ± 5.6 13.4 ± 7.6 0.30 0.43
Adduction 16.1 ± 10.0 20.4 ± 11.8 11.8 ± 6.0 0.11 0.92
(N = 14) (N = 9) (N = 5)
External rotation 9.3 ± 4.4 9.3 ± 4.7 7.9 ± 4.0 0.58 0.32
Internal rotation 8.2 ± 2.6 9.2 ± 2.1 6.0 ± 2.5 0.07 1.38

We found a correlation between the postoperative Constant-Murley score and the abduction and external rotation torques (Fig. 1). Similar correlations were found for the DASH score and (D)SST (Table 3), with the maximum torque values at 60° per second. There was no major correlation for the adduction and internal rotation motions. An overview of all the clinical outcome scores of the whole group, the primary and the revision cases is presented (Table 4).

Fig. 1.

Fig. 1

Pearson’s correlation between the maximal abduction and external rotation torque at 60° per second and the postoperative Constant-Murley score show a correlation between the force-generating capacity of patients with a reverse shoulder prosthesis and their postoperative Constant-Murley score for abduction and external rotation.

Table 3.

Pearson’s correlation between maximum torque at 60° per second and the postoperative Constant-Murley score, DASH, and (D)SST

Maximum torque at 60° per second Constant-Murley score DASH (D)SST
Abduction

0.507

p = 0.014

−0.572

p = 0.004

0.519

p = 0.011

Adduction

0.393

p = 0.183

−0.319

p = 0.29

0.408

p = 0.166

External rotation

0.614

p = 0.026

−0.531

p = 0.062

0.600

p = 0.03

Internal rotation

0.441

p = 0.216

−0.498

p = 0.205

0.455

p = 0.206

(D)SST = Dutch translation of the Simple Shoulder Test.

Table 4.

Constant-Murley scores, relative Constant-Murley scores, DASH scores, and (D)SST

Scores All shoulders ± SD (range) Primary ± SD (range) Revision ± SD (range)
Constant-Murley preoperative 24 ± 11 (5–47) 28 ± 9 (13–47) 20 ± 12 (5–47)
Constant-Murley postoperative 50 ± 21 (8–87) 59 ± 20 (8–87) 38 ± 18 (11–73)
Relative Constant-Murley preoperative 33% ± 17% (7–71) 38% ± 14% (19–68) 27% ± 18% (7–71)
Relative Constant-Murley postoperative 70% ± 31% (9–124) 83% ± 30% (9–124) 53% ± 22% (14–92)
DASH postoperative 43.9 ± 25.6 (1.7–84.2) 31.5 ± 24.4 (1.7–77.5) 60.3 ± 17.1 (31.2–84.2)
(D)SST postoperative 7 ± 4 (0–13) 8 ± 4 (0–13) 4 ± 3 (1–10)

(D)SST = Dutch translation of the Simple Shoulder Test.

Discussion

The reverse shoulder prosthesis provides a surgical option for conditions such as cuff tear arthropathy, shoulder pseudoparalysis resulting from massive cuff tear, severe fractures, prosthetic revision, and tumor surgery [5] with generally satisfying postoperative results [12, 31]. However, the contribution of this prosthesis to restoration of arm function is less clear. Previous research [3] suggests the limited glenohumeral motion of the reverse prosthesis seems to be the result of a lack of joint torque generation rather than a structural limitation caused by the prosthetic design. Therefore, the evaluation of isokinetic shoulder strength after reverse shoulder replacement may be of interest in modeling dynamic upper extremity function, particularly where comparative data are not currently available for this clinical scenario. We therefore (1) determined joint torques in patients with a reverse shoulder prosthesis and (2) determined whether force-generating capacity correlates with functional scores.

We note limitations to our study, one of which is the absence of proper control data. First, ideally a comparison would be made with an age-matched control group without cuff disorders. However, with a prevalence of 31% of asymptomatic (ie, unrecognized) cuff tears in individuals between 70 and 79 years old [38] and a prevalence of 51% in individuals older than 80 years [38], this is not feasible without extensive screening. Another possibility would be to compare the outcomes with those of the contralateral side in the same patient. However, cuff disorders in the contralateral shoulder are not uncommon, as reported by Yamaguchi et al. [45] in their demographic and morphologic study of rotator cuff disease. The average age for patients with a bilateral cuff tear in their group was 67.8 years and logistic regression analysis indicated a 50% likelihood of a bilateral tear after the age of 66 years. Furthermore, patients with a full-thickness symptomatic tear had a 35.5% prevalence of a full-thickness tear on the contralateral side. In our patient population, 12% already had a reverse prosthesis on both sides, showing that our patient group was not suitable to use the contralateral side as a comparison. As a consequence data had to be compared with norm data from the literature. Second, we had a broad range of followup times for the force measurements and clinical outcome scores. Ideally the measurements should have been performed at the same time postoperatively for every patient with a minimum followup of 1 year. This is also true for the clinical outcome scores, because they require time to stabilize. In the scope of this study, it was not possible to include patients with the same followup period, as this would have required an inclusion period of several years. We therefore chose to include all patients available from our pool of treated patients, which inevitably led to a large range in followup times. It is not certain what effect the followup time will have had, which especially applies for the elderly population for whom recovery might be counteracted by ageing effects. Given the number of available patients, controlling for age and followup will be virtually impossible whereas including larger groups and testing for those factors also do not seem to be realistic options. Third, we limited our measurements to 60° per second. Isokinetic strength measurements have been performed at different velocities, mostly from 60° per second to 300° per second [7] with some exceptions at 30° per second (Table 1). In these measurements, the applied torque needs to increase above a threshold value to successfully perform a certain task at higher speeds. Because the physiologic changes at older age lead to a decline in force-generating capacity and the reverse shoulder prosthesis is implanted mainly in patients with a mean age of 72 years [18, 36], similar to the average age of the participants in our study, we decided to apply a relatively low velocity of 60° per second. Considering our data and the number of patients unable to perform the tests (Table 2), it appeared that even 60° per second was too high for most of the patients with a reverse prosthesis. Future research investigating force production of this patient population should incorporate velocities less than 60° per second. Whether a lower velocity would lead to substantially more successful tests however is unknown; in our protocol a standard threshold of 15° per second was used to start measurements, which even proved to be too much for some of our patients.

Trying to place our obtained torque values (Table 2) in perspective, we compared our data with those of normal healthy subjects (Table 1). From this comparison we can conclude that patients with a reverse prosthesis who can generate sufficient force to perform the tasks have abduction and adduction torques of 19% to 78% of those of a normal shoulder at a velocity of 60° per second. For the external and internal rotation torques, these values vary between 13% and 71%. However, those normal values were based on younger subjects than our group of patients and in most series they include groups of athletes. If we compare our data with the only age-related series of Verney et al. [42], our patients have an abduction torque of 33% of that of 10 male elderly volunteers. It is not clear what causes this relatively low abduction torque. From the total of 37 shoulders, only 23 patients (24 shoulders) could generate enough force to perform the abduction and adduction tasks and for the external and internal rotation, the number of patients was even less (Table 2). The difference between those two tasks can be explained by the changed biomechanics caused by the reverse shoulder prosthesis. By displacing the center of rotation medially, more fibers of the anterior and posterior parts of the deltoid muscle are recruited for anteflexion or abduction of the arm and therefore fewer fibers are available to internally or externally rotate the arm [5]. Our study group included patients with primary and revision implantations. In revision surgery with a reverse prosthesis, the improvement of function is reportedly only to approximately 70° of active elevation [25], with a higher complication rate [44] than with primary surgery. Therefore, we expected to find a difference in force-generating capacity between the two groups (Table 2) in favor of the primary prosthesis. However, this could not be confirmed for the abduction and adduction tasks because 62% of the primary and 69% of the revision cases were able to generate enough force. For the internal and external rotation tasks, it was 43% and 31% respectively, confirming our expectation and explained by the previously mentioned change of biomechanics after a reverse prosthesis.

Impaired shoulder strength is likely one of the causes of active ROM limitations. The correlations we found between clinical outcome scores (Constant-Murley, DASH, and [D]SST) and the abduction and external rotation torque values (Table 3) support this contention. Functional outcome probably is not determined by simple ROM ranges alone, but also by the actual capacity for material handling in elevated and axially rotated arm positions. For example, it can be expected that patients who have good anteflexion or abduction with limited external rotation strength define their functional outcome as poor. Therefore, it seems logical that greater external rotation torque provides a better functional outcome. Although our findings support this notion, only 13 of a total of 37 shoulders actually were able to generate enough force to perform the tasks at 60° per second. Testing under lighter conditions (30° per second) could have provided more data but probably would not have led to another observation.

Patients with a reverse prosthesis were moderately to strongly limited in strength, which was the case for abduction and adduction and even more for external and internal rotation. However, future isokinetic data collection in these patients should be performed at a lower velocity than 60° per second. Results for strength correlated with clinical outcome scores (Constant-Murley, DASH, and [D]SST) indicating moderately strong relationships and a moderate predictive value of the outcome scores. Although it is likely that lower isokinetic shoulder strength in patients with joint arthroplasties is a major factor in reduced ROM, the actual causes of loss of strength would need to be identified in future studies.

Acknowledgments

We thank Jeroen H. M. Bergmann PhD, Department of Cancer & Surgery, Imperial College London, UK, for assistance with the measurements and critical comments while writing the draft. We also thank Bart J. Burger MD, PhD, orthopaedic surgeon at Medic Centrum Alkmaar, The Netherlands, for allowing us to perform measurements on his patients.

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Footnotes

One of the authors (WJW) received funding for this research from Tornier SA, France.

All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research editors and board members are on file with the publication and can be viewed on request.

Each author certifies that his or her institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.

Patients were operated on at the Onze Lieve Vrouwe Gasthuis and Medisch Centrum Alkmaar, The Netherlands. The measurements were performed at Duyvensz-Nagel Research Laboratory, Reade, Centre for Rehabilitation and Rheumatology where the Biodex system is situated.

References

  • 1.Amako M, Imai T, Okamura K. Recovery of shoulder rotational muscle strength after a combined Bankart and modified Bristow procedure. J Shoulder Elbow Surg. 2008;17:738–743. doi: 10.1016/j.jse.2008.01.145. [DOI] [PubMed] [Google Scholar]
  • 2.Ambrosio F, Boninger ML, Souza AL, Fitzgerald SG, Koontz AM, Cooper RA. Biomechanics and strength of manual wheelchair users. J Spinal Cord Med. 2005;28:407–414. doi: 10.1080/10790268.2005.11753840. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Bergmann JH, de Leeuw M, Janssen TW, Veeger DH, Willems WJ. Contribution of the reverse endoprosthesis to glenohumeral kinematics. Clin Orthop Relat Res. 2008;466:594–598. doi: 10.1007/s11999-007-0091-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Bigoni M, Gorla M, Guerrasio S, Brignoli A, Cossio A, Grillo P, Marinoni EC. Shoulder evaluation with isokinetic strength testing after arthroscopic rotator cuff repairs. J Shoulder Elbow Surg. 2009;18:178–183. doi: 10.1016/j.jse.2008.09.002. [DOI] [PubMed] [Google Scholar]
  • 5.Boileau P, Watkinson DJ, Hatzidakis AM, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14(1 suppl):147S–161S. doi: 10.1016/j.jse.2004.10.006. [DOI] [PubMed] [Google Scholar]
  • 6.Codine P, Bernard PL, Pocholle M, Benaim C, Brun V. Influence of sports discipline on shoulder rotator cuff balance. Med Sci Sports Exerc. 1997;29:1400–1405. doi: 10.1097/00005768-199711000-00002. [DOI] [PubMed] [Google Scholar]
  • 7.Codine P, Bernard PL, Pocholle M, Herisson C. Isokinetic strength measurement and training of the shoulder: methodology and results] [in French. Ann Readapt Med Phys. 2005;48:80–92. doi: 10.1016/j.annrmp.2004.07.002. [DOI] [PubMed] [Google Scholar]
  • 8.Constant CR, Gerber C, Emery RJ, Sojbjerg JO, Gohlke F, Boileau P. A review of the Constant score: modifications and guidelines for its use. J Shoulder Elbow Surg. 2008;17:355–361. doi: 10.1016/j.jse.2007.06.022. [DOI] [PubMed] [Google Scholar]
  • 9.Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;214:160–164. [PubMed] [Google Scholar]
  • 10.Dauty M, Dominique H, Helena A, Charles D. Evolution of the isokinetic torque of shoulder rotators before and after 3 months of shoulder stabilization by the Latarjet technique] [in French. Ann Readapt Med Phys. 2007;50:201–208. doi: 10.1016/j.annrmp.2007.01.009. [DOI] [PubMed] [Google Scholar]
  • 11.Demirors H, Circi E, Akgun RC, Tarhan NC, Cetin N, Akpinar S, Tuncay IC. Correlations of isokinetic measurements with tendon healing following open repair of rotator cuff tears. Int Orthop. 2010;34:531–536. doi: 10.1007/s00264-009-0827-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Drake GN, O’Connor DP, Edwards TB. Indications for reverse total shoulder arthroplasty in rotator cuff disease. Clin Orthop Relat Res. 2010;468:1526–1533. doi: 10.1007/s11999-009-1188-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Drouin JM, Valovich-mcLeod TC, Shultz SJ, Gansneder BM, Perrin DH. Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements. Eur J Appl Physiol. 2004;91:22–29. doi: 10.1007/s00421-003-0933-0. [DOI] [PubMed] [Google Scholar]
  • 14.Ellenbecker TS, Elmore E, Bailie DS. Descriptive report of shoulder range of motion and rotational strength 6 and 12 weeks following rotator cuff repair using a mini-open deltoid splitting technique. J Orthop Sports Phys Ther. 2006;36:326–335. doi: 10.2519/jospt.2006.2191. [DOI] [PubMed] [Google Scholar]
  • 15.Ellenbecker TS, Mattalino AJ. Glenohumeral joint range of motion and rotator cuff strength following arthroscopic anterior stabilization with thermal capsulorraphy. J Orthop Sports Phys Ther. 1999;29:160–167. doi: 10.2519/jospt.1999.29.3.160. [DOI] [PubMed] [Google Scholar]
  • 16.Erol O, Ozcakar L, Celiker R. Shoulder rotator strength in patients with stage I-II subacromial impingement: relationship to pain, disability, and quality of life. J Shoulder Elbow Surg. 2008;17:893–897. doi: 10.1016/j.jse.2008.05.043. [DOI] [PubMed] [Google Scholar]
  • 17.Fleury AM, Silva AC, Pochini A, Ejnisman B, Lira CA, Andrade Mdos S. Isokinetic muscle assessment after treatment of pectoralis major muscle rupture using surgical or non-surgical procedures. Clinics Sao Paulo. 2011;66:313–320. doi: 10.1590/S1807-59322011000200022. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Gerber C, Pennington SD, Nyffeler RW. Reverse total shoulder arthroplasty. J Am Acad Orthop Surg. 2009;17:284–295. doi: 10.5435/00124635-200905000-00003. [DOI] [PubMed] [Google Scholar]
  • 19.Greenfield BH, Donatelli R, Wooden MJ, Wilkes J. Isokinetic evaluation of shoulder rotational strength between the plane of scapula and the frontal plane. Am J Sports Med. 1990;18:124–128. doi: 10.1177/036354659001800202. [DOI] [PubMed] [Google Scholar]
  • 20.Harbo T, Brincks J, Andersen H. Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body mass, height, and sex in 178 healthy subjects. Eur J Appl Physiol. 2011;112:267–275. doi: 10.1007/s00421-011-1975-3. [DOI] [PubMed] [Google Scholar]
  • 21.Hiemstra LA, Sasyniuk TM, Mohtadi NG, Fick GH. Shoulder strength after open versus arthroscopic stabilization. Am J Sports Med. 2008;36:861–867. doi: 10.1177/0363546508314429. [DOI] [PubMed] [Google Scholar]
  • 22.Ivey FM, Jr, Calhoun JH, Rusche K, Bierschenk J. Isokinetic testing of shoulder strength: normal values. Arch Phys Med Rehabil. 1985;66:384–386. [PubMed] [Google Scholar]
  • 23.Kirkley A, Griffin S, Dainty K. Scoring systems for the functional assessment of the shoulder. Arthroscopy. 2003;19:1109–1120. doi: 10.1016/j.arthro.2003.10.030. [DOI] [PubMed] [Google Scholar]
  • 24.Leroux JL, Codine P, Thomas E, Pocholle M, Mailhe D, Blotman F. Isokinetic evaluation of rotational strength in normal shoulders and shoulders with impingement syndrome. Clin Orthop Relat Res. 1994;304:108–115. [PubMed] [Google Scholar]
  • 25.Levy JC, Virani N, Pupello D, Frankle M. Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. J Bone Joint Surg Br. 2007;89:189–195. doi: 10.2106/JBJS.E.01310. [DOI] [PubMed] [Google Scholar]
  • 26.Liem D, Meier F, Thorwesten L, Marquardt B, Steinbeck J, Poetzl W. The influence of arthroscopic subscapularis tendon and capsule release on internal rotation strength in treatment of frozen shoulder. Am J Sports Med. 2008;36:921–926. doi: 10.1177/0363546507313090. [DOI] [PubMed] [Google Scholar]
  • 27.Lin HC, Li JS, Lo SF, Shih YF, Lo CY, Chen SY. Isokinetic characteristics of shoulder rotators in patients with adhesive capsulitis. J Rehabil Med. 2009;41:563–568. doi: 10.2340/16501977-0378. [DOI] [PubMed] [Google Scholar]
  • 28.McMaster WC, Long SC, Caiozzo VJ. Isokinetic torque imbalances in the rotator cuff of the elite water polo player. Am J Sports Med. 1991;19:72–75. doi: 10.1177/036354659101900112. [DOI] [PubMed] [Google Scholar]
  • 29.McMaster WC, Long SC, Caiozzo VJ. Shoulder torque changes in the swimming athlete. Am J Sports Med. 1992;20:323–327. doi: 10.1177/036354659202000315. [DOI] [PubMed] [Google Scholar]
  • 30.Moraes GF, Faria CD, Teixeira-Salmela LF. Scapular muscle recruitment patterns and isokinetic strength ratios of the shoulder rotator muscles in individuals with and without impingement syndrome. J Shoulder Elbow Surg. 2008;17(1 suppl):48S–53S. doi: 10.1016/j.jse.2007.08.007. [DOI] [PubMed] [Google Scholar]
  • 31.Naveed MA, Kitson J, Bunker TD. The Delta III reverse shoulder replacement for cuff tear arthropathy: a single-centre study of 50 consecutive procedures. J Bone Joint Surg Br. 2011;93:57–61. doi: 10.1302/0301-620X.93B1.24218. [DOI] [PubMed] [Google Scholar]
  • 32.Otis JC, Warren RF, Backus SI, Santner TJ, Mabrey JD. Torque production in the shoulder of the normal young adult male: the interaction of function, dominance, joint angle, and angular velocity. Am J Sports Med. 1990;18:119–123. doi: 10.1177/036354659001800201. [DOI] [PubMed] [Google Scholar]
  • 33.Raiss P, Baumann F, Akbar M, Rickert M, Loew M. Open screw fixation of large anterior glenoid rim fractures: mid- and long-term results in 29 patients. Knee Surg Sports Traumatol Arthrosc. 2009;17:195–203. doi: 10.1007/s00167-008-0677-9. [DOI] [PubMed] [Google Scholar]
  • 34.Rokito AS, Zuckerman JD, Gallagher MA, Cuomo F. Strength after surgical repair of the rotator cuff. J Shoulder Elbow Surg. 1996;5:12–17. doi: 10.1016/S1058-2746(96)80025-5. [DOI] [PubMed] [Google Scholar]
  • 35.Sirota SC, Malanga GA, Eischen JJ, Laskowski ER. An eccentric- and concentric-strength profile of shoulder external and internal rotator muscles in professional baseball pitchers. Am J Sports Med. 1997;25:59–64. doi: 10.1177/036354659702500111. [DOI] [PubMed] [Google Scholar]
  • 36.Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff: results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388–395. doi: 10.1302/0301-620X.86B3.14024. [DOI] [PubMed] [Google Scholar]
  • 37.Stickley CD, Hetzler RK, Freemyer BG, Kimura IF. Isokinetic peak torque ratios and shoulder injury history in adolescent female volleyball athletes. J Athl Train. 2008;43:571–577. doi: 10.4085/1062-6050-43.6.571. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Tempelhof S, Rupp S, Seil R. Age-related prevalence of rotator cuff tears in asymptomatic shoulders. J Shoulder Elbow Surg. 1999;8:296–299. doi: 10.1016/S1058-2746(99)90148-9. [DOI] [PubMed] [Google Scholar]
  • 39.Tis LL, Maxwell T. The effect of positioning on shoulder isokinetic measures in females. Med Sci Sports Exerc. 1996;28:1188–1192. doi: 10.1097/00005768-199609000-00016. [DOI] [PubMed] [Google Scholar]
  • 40.van Laarhoven HA, te Slaa RL, de Boer LM, Willems WJ. The Dutch Simple Shoulder Test, an efficient way of assessing shoulder function. Dutch J Orthop. 2001;8:5–8. [Google Scholar]
  • 41.van Meeteren J, Roebroeck ME, Selles RW, Stam HJ. Responsiveness of isokinetic dynamometry parameters, pain and activity level scores to evaluate changes in patients with capsulitis of the shoulder. Clin Rehabil. 2006;20:496–501. doi: 10.1191/0269215506cr983oa. [DOI] [PubMed] [Google Scholar]
  • 42.Verney J, Kadi F, Saafi MA, Piehl-Aulin K, Denis C. Combined lower body endurance and upper body resistance training improves performance and health parameters in healthy active elderly. Eur J Appl Physiol. 2006;97:288–297. doi: 10.1007/s00421-006-0175-z. [DOI] [PubMed] [Google Scholar]
  • 43.Walker SW, Couch WH, Boester GA, Sprowl DW. Isokinetic strength of the shoulder after repair of a torn rotator cuff. J Bone Joint Surg Am. 1987;69:1041–1044. [PubMed] [Google Scholar]
  • 44.Wall B, Nove-Josserand L, O’Connor DP, Edwards TB, Walch G. Reverse total shoulder arthroplasty: a review of results according to etiology. J Bone Joint Surg Am. 2007;89:1476–1485. doi: 10.2106/JBJS.F.00666. [DOI] [PubMed] [Google Scholar]
  • 45.Yamaguchi K, Ditsios K, Middleton WD, Hildebolt CF, Galatz LM, Teefey SA. The demographic and morphological features of rotator cuff disease: a comparison of asymptomatic and symptomatic shoulders. J Bone Joint Surg Am. 2006;88:1699–1704. doi: 10.2106/JBJS.E.00835. [DOI] [PubMed] [Google Scholar]
  • 46.Yian EH, Ramappa AJ, Arneberg O, Gerber C. The Constant score in normal shoulders. J Shoulder Elbow Surg. 2005;14:128–133. doi: 10.1016/j.jse.2004.07.003. [DOI] [PubMed] [Google Scholar]

Articles from Clinical Orthopaedics and Related Research are provided here courtesy of The Association of Bone and Joint Surgeons

RESOURCES