Abstract

Speech recognition reporting for chest examinations was introduced and tightly integrated with a Radiology Information System (RIS) and a Picture Archiving and Communications System (PACS). A feature of this integration was the unique one-to-one coupling of the workstation displayed case and the reporting via speech recognition for thatand only that particular examination and patient. The utility of the resulting, wholly integrated electronic environment was then compared with that of the previous analog chest unit and dedicated wet processor, with reporting of hard copy examinations by direct dictation to a typist. Improvements in quality of service in comparison to the previous work environment include (1) immediate release of the patient, (2) decreased rate of repeat radiographs, (3) improved image quality, (4) decreased time for the examination to be available for interpretation, (5) automatic hanging of current and previous images, (6) ad-hoc availability of images, (7) capability of the radiologist to immediately review and correct the transcribed report, (8) decreased time for clinicians to view results, and (9) increased capacity of examinations per room.

Key Words: chest imaging, RIS, PACS, speech recognition, selenium, image quality, workflow

Full Text

The Full Text of this article is available as a PDF (1.3 MB).

References

  • 1.Swensen SJ, Gray JE, Brown LR, et al. A new asymmetric screen-film combination for conventional chest radiography: evaluation in 50 patients. AJR. 1993;160:483–486. doi: 10.2214/ajr.160.3.8430540. [DOI] [PubMed] [Google Scholar]
  • 2.Bunch P. Performance characteristics of asymmetric zerocrossover screen-film systems. Proc SPIE. 1992;1653:46–65. doi: 10.1117/12.59484. [DOI] [Google Scholar]
  • 3.Bauman RA. Reporting and communications. Radiol Clin North Am. 1996;34:597–606. [PubMed] [Google Scholar]
  • 4.Williamson B. Picture archiving and communication system activities at the Mayo Clinic Rochester. J Digit Imaging. 1998;11:12–15. doi: 10.1007/BF03168171. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Neitzel U, Maack I, Gunther-Kohfahl S, et al. Image quality of a digital chest radiography system based on a selnium detector. Med Phys. 1994;21:509–516. doi: 10.1118/1.597389. [DOI] [PubMed] [Google Scholar]
  • 6.Pavlicek W, Zavalkovskiy B, Eversman W, et al. Performance and function of a multiple star topology image management system at Mayo Clinic Scottsdale. J Digit Imaging. 1999;12:168–174. doi: 10.1007/BF03168791. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Rosenthal DI, Chew FS, Dupuy DE, et al. Computer-based digital radiography of the chest: Radiologists' preference compared with film-screen radiographs. AJR. 1995;165:1353–1358. doi: 10.2214/ajr.165.6.7484562. [DOI] [PubMed] [Google Scholar]
  • 8.Collins J: Personal communication, March 29, 1999
  • 9.Launders J: An evaluation of the clinical and technical performance of Philips Medical Systems Thoravision chest x-ray system. FAXiL Medical Devices Agency (MDA), Evaluation Report 96/31, 1996
  • 10.Blume H: Thoravision—The algorithms in digital chest system. Philips Medical Systems Digital Radiography 1996, pp 2–15
  • 11.Floyd CE, Baker JA, Chotas HG, et al. Selenium-based digital radiography of the chest: Radiologists' preference compared with film-screen radiographs. AJR. 1995;165:1353–1358. doi: 10.2214/ajr.165.6.7484562. [DOI] [PubMed] [Google Scholar]
  • 12.Gay SB, Sobel AH, Young LQ, et al. Processes involved in reading imaging studies: Workflow analysis and implications for workstation development. J Digit Imaging. 1997;10:40–45. doi: 10.1007/BF03168549. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Stuck BW, Arthurs E. A Computer and Communications Network Performance Analysis Primer. New Jersey: Bell Laboratories; 1985. Mean value analysis; pp. 140–205. [Google Scholar]
  • 14.Metter R, Dickerson R. Objective performance characteristics of a new asymmetric screen-film system. Med Phys. 1994;21:1483–1490. doi: 10.1118/1.597407. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Digital Imaging are provided here courtesy of Springer

RESOURCES