A suite of performance tests are defined and performed on a total of 10 primary diagnostic image review workstations. System architectures, user interface, image manipulation tools, and data retrieval rates are discussed and analyzed. Performance timings are normalized to MB/sec to remove image file size dependencies from the data analysis. Although it is likely that some performance and capacity data may be dated as this article goes to press, it is hoped that the test definitions, methodology, and baseline data will aid those contemplating equipment purchases to make a more informed choice.
Key Words: PACS, teleradiology, workstations, performance evaluation, computers, radiology
Full Text
The Full Text of this article is available as a PDF (1.8 MB).
References
- 1.Langer S, Wang J. A goal based cost-benefit analysis for film vs. filmless radiology departments. J Digit Imaging. 1996;9:104–112. doi: 10.1007/BF03168604. [DOI] [PubMed] [Google Scholar]
- 2.Beard D, Parrish D, Stevenson D. A cost analysis of film image management and four PACS based on different network protocols. J Digit Imaging. 1990;3:108–118. doi: 10.1007/BF03170570. [DOI] [PubMed] [Google Scholar]
- 3.Langer S, Wang J. Purchasing guidelines for information system software in a filmless radiology environment. J Digit Imaging. 1996;9:113–118. doi: 10.1007/BF03168605. [DOI] [PubMed] [Google Scholar]
- 4.Kodak Health Imaging Systems, PDS V2.5.6 Rochester NY, 1-800-KHIS-009
- 5.ICON Medical Systems, Telemax V2.0, Campbell CA 95008
- 6.EMED, StatView/DX for Windows V1.1A, San Antonio TX 78230-1024
- 7.GE Medical Systems, Advantage Windows V1.2, P.O. Box 414, Milwaukee WI 53201
- 8.CEMAX, VIP Release 1.41, 47291 Mission Falls Court, Fremont, CA, 94539
- 9.ALI, UltraPACS V2.43.03, Richmond BC, Canada, 1800 663 2533
- 10.Acuson Corp, Aegis, 1220 Charleston Road, P.O. Box 7393, Mountain View CA 94039
- 11.ATL, Access, Bothell WA 98041-3003
- 12.Lockheed Martin Medical Imaging Systems, LiteBox V5.3, 2501 North Barrington Road, Hoffman Estates, IL 60195, 1-800-449-7811
- 13.Siemens Medical Engineering, MagicView VA02D, Erlangen, Germany