Skip to main content
Journal of Digital Imaging logoLink to Journal of Digital Imaging
. 1998 Nov;11(4):176–181. doi: 10.1007/BF03178080

Clinical evaluation of irreversible data compression for computed radiography of the chest

Kanji Egashira 1, Hajime Nakata 1, Hideyuki Watanabe 1, Kazuhiko Uchida 1, Katsumi Nakamura 1, Yoichi Ishino 1, Kenji Horino 1, Rie Yoshikawa 1
PMCID: PMC3453153  PMID: 9848050

Abstract

Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal cases, with an additional 15 cases of lung cancers with solitary lung nodules, were selected from the file. A pair of hard copies of original images and images reconstructed using type III compression was made for each case. Six radiologists evaluated the image quality by visual rating and receiver operating characteristic (ROC) curve analysis. For all five anatomic regions of normal cases, “original equal to compressed” was the most common response, followed by “original significantly better than compressed.” When abnormal cases were evaluated for diagnostic information, there was no significant difference between the compressed and original images. ROC curve analysis on lung nodules with lung cancer showed no significant difference between the two. Compressed CR images using the type III irreversible technique are clinically applicable and acceptable despite slight degradation of image quality.

Key words: computed radiography, data compression, chest

Full Text

The Full Text of this article is available as a PDF (660.0 KB).

References

  • 1.Sonoda M, Takano M, Miyahara J, et al. Computed radiography utilizing scanning laser stimulated luminiscence. Radiology. 1983;148:833–838. doi: 10.1148/radiology.148.3.6878707. [DOI] [PubMed] [Google Scholar]
  • 2.Schaefer CM, Greene R, Oestmann JW, et al. Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease. Radiology. 1990;174:207–210. doi: 10.1148/radiology.174.1.2294549. [DOI] [PubMed] [Google Scholar]
  • 3.Niklason LT, Chan H-P, Cascade PN, et al. Portable chest imaging: Comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems. Radiology. 1993;186:387–393. doi: 10.1148/radiology.186.2.8421740. [DOI] [PubMed] [Google Scholar]
  • 4.MacMahon, Vyborny C. Technical advances in chest radiography. AJR. 1994;163:1049–1059. doi: 10.2214/ajr.163.5.7976874. [DOI] [PubMed] [Google Scholar]
  • 5.Ishigaki T, Endo T, Ikeda M, et al. Subtle pulmonary disease: Detection with computed radiography versus conventional chest radiography. Radiology. 1996;201:51–60. doi: 10.1148/radiology.201.1.8816520. [DOI] [PubMed] [Google Scholar]
  • 6.MacMahon H, Doi K, Sanada S, et al. Data compression: Effect on diagnostic accuracy in digital chest radiography. Radiology. 1991;178:175–179. doi: 10.1148/radiology.178.1.1984299. [DOI] [PubMed] [Google Scholar]
  • 7.Ishigaki T, Sakuma S, Ikeda M, et al. Clinical evaluation of irreversible image compression: Analysis of chest imaging with computed radiography. Radiology. 1990;175:739–743. doi: 10.1148/radiology.175.3.2343125. [DOI] [PubMed] [Google Scholar]
  • 8.Goldberg MA, Pivovarov M, Mayo-Smith WW, et al. Application of wavelet compression to digitized radiographs. AJR. 1994;163:463–468. doi: 10.2214/ajr.163.2.8037051. [DOI] [PubMed] [Google Scholar]
  • 9.Mori T, Nakata H. Irreversible data compression in chest imaging using computed radiography: An evaluation. J Thorac Imaging. 1994;9:23–30. [PubMed] [Google Scholar]
  • 10.Kido S, Ikezoe J, Kondoh H, et al. Detection of subtle interstitial abnormalities on digital chest radiographs: Acceptable data compression ratios. AJR. 1996;167:111–115. doi: 10.2214/ajr.167.1.8659352. [DOI] [PubMed] [Google Scholar]
  • 11.Uchida K. Evaluation of data compression in gastrointestinal examinations using computed radiography. Nippon Acta Radiol. 1996;56:482–489. [PubMed] [Google Scholar]
  • 12.Uchida K, Nakamura K, Watanabe H, et al. Clinical evaluation of irreversible data compression for computed radiography in excretory urography. J Digit Imaging. 1996;9:145–149. doi: 10.1007/BF03168610. [DOI] [PubMed] [Google Scholar]
  • 13.Uchida K, Watanabe H, Aoki T, et al. Clinical evaluation of irreversible data compression for computed radiography of the hand. J Digit Imaging. 1998;11:121–125. doi: 10.1007/BF03168735. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 1982;143:29–36. doi: 10.1148/radiology.143.1.7063747. [DOI] [PubMed] [Google Scholar]
  • 15.Metz CE. ROC methodology in radiologic imaging. Invest Radiol. 1986;21:720–733. doi: 10.1097/00004424-198609000-00009. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Digital Imaging are provided here courtesy of Springer

RESOURCES