Skip to main content
Indian Journal of Clinical Biochemistry logoLink to Indian Journal of Clinical Biochemistry
. 2005 Jan;20(1):98–102. doi: 10.1007/BF02893051

Arterial blood gas management during cardiopulmonary bypass

O P Sanjay 1,, Anitha Devnath 2, B C Thejas 1
PMCID: PMC3454162  PMID: 23105503

Abstract

This study sought to investigate the effects of α-stat and pH stat regimens on cardiac outcome during moderate hypothermic cardiopulmonary bypass. 100 patients undergoing elective coronary artery bypass grafting (CABG) were randomly assigned with respect to the target value for PaCO2 during cardiopulmonary bypass (CPB) into 2 groups. In 50 patients the target PaCO2 was 40 mmHg, measured at a standard electrode temperature of 37°C while in the other 50 patients the target PaCO2 was 40 mmHg, corrected to the patients nasopharyngeal temperature (lowest value reached: 32±0.5°C). There were no significant differences between groups with regards to cardiac outcome such as appearance of new ‘Q’ waves on the electrocardiogram, postoperative creatinine kinase-MB fraction, systemic vascular resistance (SVR), cardiac index (Cl), need for inotropic or intra-aortic balloon pump support and the length of postoperative ventilation or intensive care unit stay. These findings support the hypothesis that CO2 management during CPB at moderate hypothermia has no clinically significant effect on cardiac outcome.

Key Words: Arterial blood gases, cardiopulmonary bypass

Full Text

The Full Text of this article is available as a PDF (378.6 KB).

References

  • 1.White FN. A comparative physiological approach to hypothermia. J Thorac Cardiovasc Surg. 1981;82:821–828. [PubMed] [Google Scholar]
  • 2.Ream AK, Reitz BA, Silverberg G. Temperature correction of Pco2 and pH in estimating acid-base status; An example of the emperors new clothes. Anesthesiology. 1982;56:41–44. doi: 10.1097/00000542-198201000-00009. [DOI] [PubMed] [Google Scholar]
  • 3.Williams JJ, Marshall BE. A fresh look at an old question. Anesthesiology. 1982;56:1–2. doi: 10.1097/00000542-198201000-00001. [DOI] [PubMed] [Google Scholar]
  • 4.White FN, Weinstein Y. Carbon Dioxide transport and acid-base balance during hypothermia. In: Utley JR, editor. Pathophysiology and techniques of cardiopulmonary bypass. Baltimore: Williams and Wilkins; 1983. pp. 40–48. [Google Scholar]
  • 5.Swan H. The importance of acid-base management for cardiac and cerebral preservation during open-heart operations. Surg Gynecol Obstet. 1984;158:391–414. [PubMed] [Google Scholar]
  • 6.Swain JA. Hypothermia and blood pH. Arch Intern Med. 1988;148:1643–1646. doi: 10.1001/archinte.148.7.1643. [DOI] [PubMed] [Google Scholar]
  • 7.Rahn H, Reeves RB, Howell BJ. Hydrogen ion regulation, temperature and evolution. Am Rev Respir Dis. 1975;112:165–172. doi: 10.1164/arrd.1975.112.2.165. [DOI] [PubMed] [Google Scholar]
  • 8.Becker H, Vinten-Johansen J, Buckberg GD, Robertson JM, Leaf JD, Lazar HL, Manganaro AJ. Myocardial damage caused by keeping pH 7.40 during deep hypothermia. J Thorac Cardiovasc Surg. 1981;82:810–820. [PubMed] [Google Scholar]
  • 9.McConnell DH, White F, Nelson RL, Goldstein SM, Maloney JV, DeLand EC, Buckberg GD. Importance of alkalosis in maintenance of ‘ideal’ blood pH during hypothermia. Surg Forum. 1975;26:263–265. [PubMed] [Google Scholar]
  • 10.Swain JA, White FN, Peters RM. The effect of pH on hypothermic ventricular fibrillation threshold. J Thorac Cardiovasc Surg. 1984;87:445–451. [PubMed] [Google Scholar]
  • 11.Sinet M, Muffat-Joly M, Bendaace T, Pocidalo JJ. Maintaining blood pH at 7.4 during hypothermia has no significant effect on work of the isolated rat heart. Anesthesiology. 1985;62:582–587. doi: 10.1097/00000542-198505000-00007. [DOI] [PubMed] [Google Scholar]
  • 12.Stephan H, Weyland A, Kazmaeir S, Henze T, Menck S, Sonntag H. Acid base management during hypothermic cardiopulmonary bypass does not effect cerebral metabolism but does effect blood flow and neurological outcome. Br J Anaesth. 1992;69:51–7. doi: 10.1093/bja/69.1.51. [DOI] [PubMed] [Google Scholar]
  • 13.Alston RF, Murray L, McLaren AD. Changes in haemodynamic variables during hypothermic cardiopulmonary bypass. J Thorac Cardiovasc Surg. 1990;100:134–44. [PubMed] [Google Scholar]
  • 14.Hickey PR, Buckley MJ, Philbin DM. Pulsatile and non-pulsatile cardiopulmonary bypass: review of a counterproductive controversy. Ann Thorac Surg. 1983;36:720–37. doi: 10.1016/s0003-4975(10)60286-x. [DOI] [PubMed] [Google Scholar]
  • 15.Stephan H, Sonntag H, Lange H, Rieke H. Cerebral effects of anesthesia and hypothermia. Anaesthesia. 1989;44:310–16. doi: 10.1111/j.1365-2044.1989.tb11284.x. [DOI] [PubMed] [Google Scholar]
  • 16.Rahn H. Body temperature and acid base regulation. Pneumonologie. 1974;151:87–94. doi: 10.1007/BF02097155. [DOI] [PubMed] [Google Scholar]
  • 17.Reeves RB. An imidazole alpha stat hypothesis for vertebrate acid-base regulation: tissue carbon dioxide content and body temperature in bullfrogs. Respir Physiol. 1972;14:219–236. doi: 10.1016/0034-5687(72)90030-8. [DOI] [PubMed] [Google Scholar]
  • 18.Cullen DJ, Eger EL, Smith NT, Cullen BF. The cardiovascular effects of carbon dioxide in man awake and during ether anesthesia. Anesthesiology. 1974;41:301–4. doi: 10.1097/00000542-197403000-00022. [DOI] [PubMed] [Google Scholar]
  • 20.Kazmaier S, Stephan H, Spiegel T, Sonntag H. Effects of different PaCO2 values on myocardial haemodynamics and energetics in patients with coronary artery disease. Br J Anaesth. 1995;76:A24–A24. [Google Scholar]
  • 21.Mundemann A, Stephan H, Weyland A, Wellhausen A, Sonntag H. Effects of acid base management on whole body oxygen uptake during hypothermic cardiopulmonary bypass in humans. Anesthesia. 1991;40:530–36. [PubMed] [Google Scholar]
  • 22.Paterson RW. Effect of PaCO2 on oxygen consumption during cardiopulmonary bypass in man. Anesth Analg. 1976;55:269–73. doi: 10.1213/00000539-197603000-00032. [DOI] [PubMed] [Google Scholar]
  • 23.Buhre W, Weyland F, Velde J, Schom B, Kazmaier S, Sonntag H. Influence of arterial carbon dioxide tension on systemic vascular resistance in patients undergoing cardiopulmonary bypass. Acta Anaesth Scand. 1998;42:167–71. doi: 10.1111/j.1399-6576.1998.tb05103.x. [DOI] [PubMed] [Google Scholar]
  • 24.DeBois WJ, Sharon I, Shevde K. Improved circulation during cardiopulmonary bypass utilizing a pulsatile device. Anaesth Analg. 1987;66:39–39. [Google Scholar]

Articles from Indian Journal of Clinical Biochemistry are provided here courtesy of Springer

RESOURCES