Abstract
Transpedicular screw fixation provides rigid stabilization of the thoracolumbar spine. For accurate insertion of screws into the pedicles and to avoid pedicle cortex perforations, more precise knowledge of the anatomy of the pedicles is necessary. This study was designed to visualize graphically the surface anatomy and internal architecture of the pedicles of the thoracic spine. Fifteen vertebrae distributed equally among the upper, middle, and lower thoracic regions were used. For the purpose of mapping surface anatomy, each pedicle was cleaned, spraypainted white, and marked with more than 100 fine points. Using an optoelectronic digitizer, three-dimensional coordinates of the marked points and three additonal points, representing a coordiate system, were digitized. A solid modeling computer program was used to create three-dimensional surface images of the pedicle. To obtain cross-sectional information, each pedicle was sectioned with a thin diamond-blade saw to obtain four slices, 1 mm in thcikness and 0.5 mm apart. The pedicle slices were X-rayed and projected onto a digitizer. The internal and external contours were digitized and converted into graphs by a computer. The pedicles exhibited significant variability in their shape and orientation, not only from region to region within the thoracic spine, but also within the same region and even within the same pedicle. These variations are extremely significant in light of current techniques utilized in transpedicular screw fixation in the thoracic spine. Information documenting the three-dimensional complexity of pedicle anatomy should be valuable for surgeons and investigators interested in spinal instrumentation.
Key words: Anatomy, Pedicles, Thoracic spine, Pedicle instrumentation, Biomechanics
Full Text
The Full Text of this article is available as a PDF (1.1 MB).
References
- 1.Amiot L-P, Labelle H, DeGuise JA, Sati M, Brodeur P, Rivard C-H. Computer-assisted pedicle screw fixation. A feasibility study. Spine. 1995;20:1208–1212. doi: 10.1097/00007632-199505150-00019. [DOI] [PubMed] [Google Scholar]
- 2.Bernard TN, Seibert CE. Pedicle diameter determined by computed tomography. Its relevance to pedicle screw fixation in the lumbar spine. Spine. 1992;17:S160–S163. doi: 10.1097/00007632-199206001-00017. [DOI] [PubMed] [Google Scholar]
- 3.Berry JL, Moran JM, Berg WS, Steffee AD. A morphometric study of human lumbar and selected thoracic vertebrae. Spine. 1987;12:362–367. doi: 10.1097/00007632-198705000-00010. [DOI] [PubMed] [Google Scholar]
- 4.Dickman CA, Yahiro MA, Lu HTC, Melkerson MN. Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. A meta-analysis. Spine. 1994;19:S2266–S2273. doi: 10.1097/00007632-199410151-00003. [DOI] [PubMed] [Google Scholar]
- 5.George DC, Krag MIL, Johnson CC, Hal ME, Haugh ID, Grobler LJ. Hole preparation techniques for transpedicular screws: effect on pullout strength from human cadaveric vertebrae. Spine. 1991;16:181–184. [PubMed] [Google Scholar]
- 6.Gertzbein SD. Scoliosis Research Society multicenter spine fracture study. Spine. 1992;17:528–540. doi: 10.1097/00007632-199205000-00010. [DOI] [PubMed] [Google Scholar]
- 7.Gertzbein SD, Robbins SE. Accuracy of pedicle screw placement in vivo. Spine. 1990;15:11–14. doi: 10.1097/00007632-199001000-00004. [DOI] [PubMed] [Google Scholar]
- 8.Kothe R, O'Holleran JD, Liu W, Panjabi MM. Internal architecture of the thoracic pedicle. An anatomical study. Spine. 1996;21:264–270. doi: 10.1097/00007632-199602010-00002. [DOI] [PubMed] [Google Scholar]
- 9.Krag M, Weaver DL, Beynnon BD, Haugh LD. Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. spine. 1988;13:27–32. doi: 10.1097/00007632-198801000-00007. [DOI] [PubMed] [Google Scholar]
- 10.Misenheimer GR, Peek RD, Wiltse LL, Rothman SLG, Widell EH. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine. 1989;14:367–372. doi: 10.1097/00007632-198904000-00004. [DOI] [PubMed] [Google Scholar]
- 11.Moran JM, Berg WS, Berry JL, Geiger JM, Steffee AD. Transpedicular screw fixation. J Orthop Res. 1989;7:107–114. doi: 10.1002/jor.1100070115. [DOI] [PubMed] [Google Scholar]
- 12.Mulholland RC. Pedicle screw fixation in the spine (editorial) J Bone Joint Surg [Br] 1994;76:517–519. [PubMed] [Google Scholar]
- 13.Nolte LP, Zamorano LJ, Jiang Z, Wang Q, Langlotz F, Berlemann U. Image-guided insertion of transpedicular screws. A laboratory set-up. Spine. 1995;20:497–500. doi: 10.1097/00007632-199502001-00016. [DOI] [PubMed] [Google Scholar]
- 14.Olsewski JM, Simmons EH, Kallen FC, Mendel FC, Severin CM, Berens DL. Morphometry of the lumbar spine: anatomical perspectives related to transpedicular fixation. J Bone Joint Surg [Am] 1990;72:541–549. [PubMed] [Google Scholar]
- 15.Panjabi MM, Takata K, Goel V, Federico D, Oxland T, Duranceau J. Thoracic human vertebrae: quantitative three-dimensional anatomy. Spine. 1991;16:888–901. doi: 10.1097/00007632-199108000-00006. [DOI] [PubMed] [Google Scholar]
- 16.Panjabi MM, Oxland TR, Takata K, Goel V, Duranceau J, Krag M, Price M. Human lumbar vertebrae: quantitative three-dimensional anatomy. Spine. 1992;17:299–306. doi: 10.1097/00007632-199203000-00010. [DOI] [PubMed] [Google Scholar]
- 17.Phillips JH, Kling TF, Cohen MD. The radiographic anatomy of the thoracic pedicle. Spine. 1994;19:446–449. doi: 10.1097/00007632-199402001-00011. [DOI] [PubMed] [Google Scholar]
- 18.Roy-Camille R, Saillant G, Mazel C. Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin Orth Am. 1986;17:147–159. [PubMed] [Google Scholar]
- 19.Saillant G. Etude anatomique des pedicules vertebraux. Application chirugicale. Rev Chir Orthop. 1976;62:151–160. [PubMed] [Google Scholar]
- 20.Scoles PV, Linton AE, Latimer B, Levy ME, Digiovanni BF. Vertebral body and posterior element morphology. The normal spine in middle life. Spine. 1988;13:1082–1086. doi: 10.1097/00007632-198810000-00002. [DOI] [PubMed] [Google Scholar]
- 21.Steinmann JC, Herkowitz HN, ElKommos H, Wesolowski DP. Spinal pedicle fixation. Confirmation of an image-based technique for screw placement. Spine. 1993;18:1856–1861. [PubMed] [Google Scholar]
- 22.Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM. Placement of pedicle screws in the thoracic spine. J Bone Joint Surg [Am] 1995;77:1193–1199. doi: 10.2106/00004623-199508000-00008. [DOI] [PubMed] [Google Scholar]
- 23.Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine. 1988;13:1012–1018. doi: 10.1097/00007632-198809000-00008. [DOI] [PubMed] [Google Scholar]
- 24.Yuan HA, Garfin SR, Dickman CA, Mardjetko SM. A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusions. Spine. 1994;19:52279–S2296. doi: 10.1097/00007632-199410151-00005. [DOI] [PubMed] [Google Scholar]
- 25.Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT. Analysis of the morphomet ric characteristics of the thoracic and lumbar pedicles. Spine. 1987;12:160–166. doi: 10.1097/00007632-198703000-00012. [DOI] [PubMed] [Google Scholar]