Abstract
Sperm were cultured at room temperature in seminal plasma, in the presence or absence of a test item or solution. Progressive motility of the sperm was measured using a Sperm Quality Analyser IIB. A progressive decline in motility of sperm was seen under control conditions from 0 hr to 24 hrs. Culture medium did not cause a significant decline in sperm survival index during the first 6 hrs of culture but did after 24 hrs. A dose dependent reduction in sperm survival index was then seen with formaldehyde. Powder-free rubber gloves proved extremely toxic unlike the associated rubber plunger of a non-pyrogenic syringe. It is concluded that the use of unwashed human sperm in survival studies allows detection of toxicity within 6 hrs, a time much less than conventional methods using washed human sperm.
Keywords: Sperm survival, toxicity
Full Text
The Full Text of this article is available as a PDF (109.4 KB).
Footnotes
Submitted in part by Melissa Iemmolo to the University of Western Australia towards her Postgraduate Diploma in Science (Zoology).
References
- 1.Claassens OE, Wehr JB, Harrison KL. Optimizing sensitivity of the human sperm motility assay for embryo toxicity testing. Hum Reprod. 2000;15:1586–1591. doi: 10.1093/humrep/15.7.1586. [DOI] [PubMed] [Google Scholar]
- 2.Critchlow JD, Matson PL, Newman MC, Horne G, Troup SA, Lieberman BA. Quality control in an in-vitro fertilization laboratory: Use of human sperm survival studies. Hum Reprod. 1989;4:545–549. doi: 10.1093/oxfordjournals.humrep.a136942. [DOI] [PubMed] [Google Scholar]
- 3.Zuvela E, Matson P. Detection of toxicity within the IVF laboratory. Art & Science. 2004;3:8–11. [Google Scholar]