Abstract

Sixty consecutive patients (60 hips) were allocated in two matched-pair groups. Patients were matched for age, gender, body mass index, level of activity, and bone stock. Both groups received an uncemented total hip arthroplasty with a modular press-fit cup and an alumina femoral head. In the first group, an acetabular liner made of polyethylene was used; in the second group, an alumina liner. Both groups were followed for a minimum of 5 years. No hip required revision, and there was no radiographic evidence of aseptic loosening in either group. Mean Harris hip score was 94.7 (87.1–99) points in the polyethylene group and 93 (88.5–100) points in the alumina group.

Full Text

The Full Text of this article is available as a PDF (181.7 KB).

Footnotes

Statement on conflict of interest: Although none of the authors has received or will receive benefits for personal or professional use from a commercial party related directly or indirectly to the subject of this article, benefits have been or will be received but will be directed solely to a research fund, foundation, educational institution, or other non-profit organisation with which one or more of the authors are associated.

References

  • 1.BizotClin Orthop 200037913411039800 [Google Scholar]
  • 2.Boehler Orthopedics. 1998;21:897. doi: 10.3928/0147-7447-19980801-17. [DOI] [PubMed] [Google Scholar]
  • 3.Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr (1973) Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg [Am] 55:1629–1632 [PubMed]
  • 4.Charnley J (1979) Numerical grading of clinical results. In: Charnley J (ed) Low friction arthroplasty of the hip. Springer, Berlin Heidelberg New York, pp 20–24
  • 5.Charnley Clin Orthop. 1975;112:170. [PubMed] [Google Scholar]
  • 6.DeLee Clin Orthop. 1976;121:20. [PubMed] [Google Scholar]
  • 7.Freeman J Arthroplasty. 1999;14:1. doi: 10.1016/s0883-5403(99)90195-x. [DOI] [PubMed] [Google Scholar]
  • 8.GarinoClin Orthop 20003794111039791 [Google Scholar]
  • 9.GruenClin Orthop 197914117477100 [Google Scholar]
  • 10.Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L (2000) Alumina-on-alumina total hip arthroplasty. A minimum 18.5-year follow-up study. J Bone J Surg [Am] 84:69–77 [PubMed]
  • 11.Harris WH (1969) Traumatic osteoarthritis of the hip after dislocation and acetabular fractures: Treatment by mould arthroplasty: An end-result study using a new method of result evaluation. J Bone Joint Surg [Am] 51:737–755 [PubMed]
  • 12.HendrichZ Orthop 19991373110327558 [Google Scholar]
  • 13.Hendrich C, Kaddick C, Willmann G (2000) Klinische Erfahrungen und Migrationsanalyse. Plasmacup. In: Willmann G, Zweymüller K (eds) Bioceramics in hip joint replacement. Thieme, Stuttgart, pp 26–34
  • 14.Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg [Am] 72:518–528 [PubMed]
  • 15.Pitto Chir Organi Mov. 1996;81:107. [PubMed] [Google Scholar]
  • 16.Pitto Biomed. 2001;Tech:109. doi: 10.1515/bmte.2001.46.4.109. [DOI] [PubMed] [Google Scholar]
  • 17.Riska Clin Orthop. 1993;297:87. [PubMed] [Google Scholar]
  • 18.Schneider E, Schönenberger U, Giraud P, Bürgi M (1992) Primärstabilität und Beckendeformation bei zementierten und nichtzementierten Hüftpfannen. Orthopäde 21:57–62 [PubMed]
  • 19.Sedel L (1999) Evolution of alumina-alumina implants. In: Sedel L, Willmann G (eds) Reliability and long-term results of ceramics in orthopaedics. Thieme, Stuttgart, pp 2–6
  • 20.Singh M, Nagrath AR, Maini PS (1970) Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis. J Bone Joint Surg [Am] 52:456–467 [PubMed]
  • 21.Willmann Hip Int. 2000;10:193. [Google Scholar]
  • 22.WillmannClin Orthop 20003792211039788 [Google Scholar]

Articles from International Orthopaedics are provided here courtesy of Springer-Verlag

RESOURCES