Abstract
Between September 2000 and February 2002 we inserted 120 total knee arthroplasties. In 60 patients we used the standard technique, and in 60 patients we used the OrthoPilot navigation system. Postoperatively all patients had standing long radiographs of the lower extremity from the hip joint to the ankle. We considered the ideal value of the anatomic lateral tibiofemoral angle (LTFA) to be 174°. In the standard group the mean value of LTFA was 174.9° and in the navigation group 174.3°. A deviation between 0° and 2° from the ideal value was seen in 42 cases in the standard group and in 53 cases in the navigation group. In the standard group 18 cases had a deviation of more than 2.1°, whereas there were only seven cases in the navigation group with a deviation exceeding 2.1°. There were no complications related to the use of the navigation system. The system affords a possibility to place femoral and tibial components precisely with less axis deviation than with the conventional technique.
Résumé
Entre septembre 2000 et février 2002 nous avons implanté 120 arthroplasties totales du genou. Chez 60 malades nous avons utilisé la technique standard et chez 60 malades nous avons utilisé le système de navigation OrthoPilot. Après l'opération tous les malades avaient une grande radiographie du membre inférieur, de la hanche à la cheville. Nous avons considéré que la valeur idéale de l'angle tibiofémoral latéral (LTFA) était de 174°. Dans le groupe standard la valeur moyenne de LTFA était 174.9°, dans le groupe navigation de 174.3°. Une déviation entre 0° et 2° de la valeur idéale a été notée dans 42 cas dans le groupe standard et dans 53 cas dans le groupe navigation. Dans le groupe standard 18 cas avaient une déviation de plus que 2.1°, alors qu'il y avait seulement 7 cas dans le groupe navigation avec une déviation dépassant 2.1°. Il n'y avait pas de complications relatives à l'usage du système de navigation. Le système offre une possibilité de placer les composants fémoral et tibial précisément avec moins de déviation de l'axe qu'avec la technique conventionnelle.
Full Text
The Full Text of this article is available as a PDF (142.6 KB).
References:
- 1.BargrenClin Orthop 19831731786825330 [Google Scholar]
- 2.Delp Clin Orthop. 1998;354:49. doi: 10.1097/00003086-199809000-00007. [DOI] [PubMed] [Google Scholar]
- 3.Elloy J Biomed. 1992;14:363. [Google Scholar]
- 4.Gossé F, Brack C, Gotte H, Roth M, Ruhmann O, Schweikard A, Vahldiek M (1997) Roboterunterstützung in der Knieendoprothetik. Orthopäde 26:258–266 [DOI] [PubMed]
- 5.Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg [Br] 73:709–714 [DOI] [PubMed]
- 6.Jenny Z Orthop. 2001;139:117. doi: 10.1055/s-2001-15041. [DOI] [PubMed] [Google Scholar]
- 7.Katz MM, Hungerford DS, Krakow KA, Lennox DW (1987) Results of total knee arthroplasty after failed proximal tibial osteotomy for osteoarthritis. J Bone Joint Surg [Am] 69:225–233 [PubMed]
- 8.Lonner Clin Orthop. 1996;331:102. doi: 10.1097/00003086-199610000-00014. [DOI] [PubMed] [Google Scholar]
- 9.Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59:77–79 [PubMed]
- 10.Mielke Z Orthop. 2001;139:100. [Google Scholar]
- 11.Oswald J Arthroplasty. 1993;8:419. doi: 10.1016/s0883-5403(06)80042-2. [DOI] [PubMed] [Google Scholar]
- 12.Patel Int Ortop. 1991;15:209. doi: 10.1007/BF00192296. [DOI] [PubMed] [Google Scholar]
- 13.PetersenJ Arthroplasty 19881673361322 [Google Scholar]
- 14.Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg [Br] 83:819–824 [DOI] [PubMed]
- 15.RitterClin Orthop 19942991538119010 [Google Scholar]
- 16.Saleh KJ, Sherman P, Katkin P, Windsor R et al (2001) Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg [Am] 83:1144–1148 [DOI] [PubMed]
- 17.Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84:90–98 [PubMed]
- 18.Toksvig-Larsen S et al (1998) Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg [Br] 80:295–297 [DOI] [PubMed]
- 19.Townley Clin Orthop. 1985;192:82. [PubMed] [Google Scholar]
- 20.Waugh MTW (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg [Br] 67:551–556 [DOI] [PubMed]
- 21.Windsor RE, Insall JN, Vince KG (1988) Technical considerations of total knee arthroplasty after proximal tibial osteotomy. J Bone Joint Surg [Am] 70:547–555 [PubMed]