Abstract
Vascular disease results in the decreased utility and decreased availability of autologus vascular tissue for small diameter (< 6 mm) vessel replacements. While synthetic polymer alternatives to date have failed to meet the performance of autogenous conduits, tissue-engineered replacement vessels represent an ideal solution to this clinical problem. Ongoing progress requires combined approaches from biomaterials science, cell biology, and translational medicine to develop feasible solutions with the requisite mechanical support, a non-fouling surface for blood flow, and tissue regeneration. Over the past two decades interest in blood vessel tissue engineering has soared on a global scale, resulting in the first clinical implants of multiple technologies, steady progress with several other systems, and critical lessons-learned. This review will highlight the current inadequacies of autologus and synthetic grafts, the engineering requirements for implantation of tissue-engineered grafts, and the current status of tissue-engineered blood vessel research.
Keywords: Vascular Tissue Engineering, mechanical requirements of blood vessels, biological requirements of blood vessels, stems cells, blood vessels, cardiovascular disease
Introduction
Cardiovascular disease (CVD) affects over 71 million people in the United States of America alone and costs exceed 500 billion dollars annually. Specific to cardiovascular disease in America, the number of annual inpatient visits totaled over 7 million with over 450,000 in-patient bypass surgeries, caused in part by diet and inherited factors [1]. Despite improvements in the medical therapy of CVD, the number of vascular interventions, including bypass grafting and angioplasty with or without stenting has increased in recent years. Vascular bypass grafting and balloon angioplasty with stent placement account for a large number of procedures and are more prevalent in patients over the age of 65 years, who are less likely to have sufficient vein for use as a conduit for revascularization [2, 3]. Although autogenous veins or arteries provide the best patency rates for cardiac and peripheral vascular bypass grafting, many patients do not have suitable vessels, and autograft suitability may be difficult to define in advance of the bypass operation.
The replacement of large diameter vessels (>6 mm), such as the aorta, has been performed successfully with synthetic polymer prosthetics with long-term patency. However, most blood vessels within the peripheral, cerebral and cardiac vasculature display diameters of less than 6 mm. Several studies have shown that smalldiameter synthetic polymer grafts have rapid thrombus formation and intimal hyperplasia subsequent to bypass surgery, limiting their utility [3–5]. These acute and chronic phenomena were localized not only to the regions of graft anastomoses but also to the mid-graft region and these findings may also extend to larger diameter grafts [6, 7]. Synthetic vascular grafts also present a continued risk of bacterial colonization and subsequent graft infection and, in addition, are capable of promoting a low-level, chronic inflammatory response that may contribute to the development of neointimal hyperplasia. Mechanically, the compliance mismatch between a prosthetic graft (0.5–1.5%/100 mmHg) and the host artery (5–15%/100 mmHg) may also lead to neointimal hyperplasia and late graft failure. Finally, the inability of synthetic grafts to grow and adapt decreases the utility of prosthetic grafts in pediatric patients.
Motivated by these limitations, the development of a tissue-engineered blood vessel (TEBV) has progressed significantly over the past two decades. In concept, the TEBV will closely match the biomechanical aspects of healthy artery and be capable of growth, remodeling, and vasoactive responses. An endothelial cell (EC) layer will provide anti-platelet, anti-coagulant and pro-fibrinolytic properties that would decrease thrombogenesis and restenosis [8].
Functional requirements in blood vessel tissue engineering
Requirements for TEBV design may be conceptually divided into the linked areas of mechanical and biological performance. Biological-mechanical interconnectivity is often desirable, such as the contractile responses achieved with some TEBV [9], or an observed increase in compliance, from 2 to 9 %/100 mmHg, after 6 months in vivo remodeling [10]. However, maladaptive biological responses leading to premature biodegradation and mechanical failure are a common consideration for all degradable-scaffold grafts.
Mechanical requirements
International standards for Dacron and ePTFE prostheses provide a foundation for these requirements, although the complexity of tissue-engineering requires developers to look much further [11]. Mechanical considerations include burst pressure, fatigue-resistance, suture retention, kinking radius, and compliance. Designers must also consider homogeneity over the length of the prosthesis, which may be tens of centimeters [12], variations as the implant remodels, and lot-to-lot variability inherent to cell-based products. Despite broad and prolonged interest in this area, standardized mechanical targets and protocols are still evolving [13].
Testing of burst pressure and mechanical resistance to catastrophic rupture/ tearing of the vascular prosthesis is required to ensure the graft can withstand physiologic variations in pressure. For example, the average pressure in the arterial circulation close to the heart is 100 mmHg, but in the femoral or popliteal artery, while standing, is about 250 mmHg, owing to the contribution of hydrostatic pressure. Conversely, pressures in the cerebral vasculature are generally lower; 60–100 mmHg [14]. However, a significantly challenging vessel to replace is the common carotid. This is due not only to high flowrates (approximating 200mL/min) but turbulent and recirculating flows at the internal/external carotid bifurcation and carotid sinus [14–17]. Thus there is still much debate as to the best approach to treat carotid atherosclerotic disease; stenting, endarterectomy, with or without a patch material or bypass grafting [18–21]. High burst pressures are clearly desirable. However, whether TEBV must match native vein, artery, or simply be at a level above maximum physiologic pressure remains debated. In pigs, investigators have suggested that TEBV with burst pressures as low as 600–700 mm Hg can be implanted in the arterial circulation without observed dilatation [22]. Typical burst pressure testing involves the steady inflation of a blood vessel/ tissue engineered construct to a pressure at which the construct starts to rupture. Porous constructs are tested by inflating either a flexible elastomer, with a stiffness negligible to that of the material being tested, in the tubular construct, or sealing the pores of the construct with a material of negligible mechanical strength. Burst pressures are measured with systems that apply increasing internal pressure loads, and record outer diameter and internal pressure. Specimens are typically maintained in physiologic buffer (37°C PBS) during testing. Of particular note is the inflation rate to bursting of tissue engineered constructs: typical inflation rates that compensate for potential creep and stress relaxation of materials in a physiologic setting have been established to be around 0.2 mL/s [23]. However, faster inflation rates have been shown to drastically increase the expected burst pressure, as the material rapidly inflates with little to no deformation. Further, it is important for grafts to remain fatigue resistant, ensuring their structural components and mechanical properties do not alter with repeated cycling in a pulsatile flow setting [24, 25]. Notably, extrapolation of burst pressure from the ultimate tensile stress of flat strips or ring specimens may over-estimate direct burst pressure measurements [13]. Interestingly, for specific TEBV systems non-invasive prediction of burst pressure from stiffness measurements at low pressures has been demonstrated [26]. Typical burst pressures of native vasculature and synthetic alternatives are shown in Table 1.
Table 1.
Mechanical properties of common blood vessels and current synthetic replacements. Ranges represent average values from cited studies.
Compliance (%/100 mmHg) | Suture Retention Strength (grams- Force) |
Burst Pressure (mmHg) |
|
---|---|---|---|
Coronary: 8.0–17.0 [37, 38], | |||
Carotid: 5.0–14.7 [39, 40], | |||
Femoral: 6.0–14.1 [41, 42], | |||
Popliteal: 4.7–8.5 [41], | 2200–4225 [43, 44] | ||
Artery | Internal thoracic artery:6.5–12.0 [13, 43] | 88–200 [13, 33] | |
Saphenous: 0.7–2.6 [33, 39, 43], | 1600–2500 [33, 43, 44, 46] | ||
Vein | Umbilical: 1.5–3.7 [39, 45] | 180–250 [33, 44, 46] | |
PTFE: 0.2–0.9 [39, 47], | |||
Synthetic grafts | Dacron: 0.76–1.9 [39, 47] | 250–1200 [48, 49] | 2580–8270 [50] |
Compliance and fatigue may be evaluated with similar test fixtures. Compliance is calculated from the percent change in internal radius over a physiologic range of pressure (80–120 mmHg) and is often expressed in units of %/100 mmHg. The pressurized inner radius must often be calculated from images of the pressurized outer diameter, the inner diameter at rest, and the assumption of incompressibility of the graft wall. Typical compliances are dependent on the locale of the vessel, arterial or venous or synthetic, detailed in Table 1 [2, 27–30]. Similar to burst pressure, the mechanical response of constructs is dependant on the rate at which scaffold inflation is performed due to time-dependant phenomena such as stress relaxation [23, 31, 32]. Further, it is critical to evaluate the compliance of tissue constructs in physiologically relevant conditions that simulate the native environment: flowrates, flow medium, pulsatile flow, pressure gradients and temperature. The reader is directed to the following references for further vessel specific mechanical properties [2, 27–30]. Fatigue testing may consist of sustained static, cyclic, or stepwise pressures profiles, followed by an assessment of the burst pressure or compliance to monitor any change from initial strength. Although the importance of short-term fatigue tests is clear, when significant biodegradation and remodeling is anticipated the predictive value of long-term in vitro fatigue tests may be limited.
Suture retention strength is measured by placing a suture 2 mm from the end of a vessel specimen and measuring the force required to dislodge the suture in a physiologically relevant condition and rate: 1 mm/s, 37°C [11]. Typical suture retention strengths of native vasculature range widely depending on vessel type (Table 1) [30, 31, 33–36].
Biological requirements
Biological failure occurs due to different modes depending on whether it occurs acutely, over the first weeks/months, or longer-term over months to years. The acute response is usually characterized by blood material interactions that lead to non-specific protein adsorption and subsequent blood clotting or thrombosis on the graft luminal surface. The chronic response to vascular graft implantation is determined in part by the remodeling of the implant, as pannus tissue grows in from the anastamotic regions or transmurally, and long term material interactions with the host, such as biodegradation and scar tissue formation [51–53].
Of note is the small population of patients that have infection during implantation (eg.Staphylococcus epidermidis) which typically populates the anastamotic regions of a graft and is estimated to be as high as 1–6% [54].
The generation of a luminal layer that prevents non-specific protein adsorption and a subsequent immune response is a significant problem that has challenged the field till present, especially with the current synthetic standard of care which uses hydrophobic materials that present surfaces that are entropically more favorable for blood protein adsorption than hydrophilic surfaces. However, to circumvent the potential for thrombus formation, novel biomaterials strive to combine hydrophilicity and resistance to protein adsorption through surface modifications or the use of a luminal layer of endothelial cells. A quiescent EC layer has been shown to be vital to promoting an (i) anti-platelet, (ii) anti-coagulant and (iii)pro-fibrinolytic surface [55–60]. Conversely, occlusion due to activation of the present or neo-endothelial cells is of major concern [5, 60–63].
Biochemical and chemical modifications, including homing of cells using CD34 antibody conjugated to graft surfaces, stromal derived factor-1 (SDF-1) an inducer of endothelial progenitor cell migration from the bone marrow, and plasma treatment of surfaces facilitate neo-endothelialization of vascular grafts. Although the source of the repopulating EC is still debated (bone marrow endothelial progenitor cells/circulating progenitor cells/ECs from the nascent vasculature), endothelial cells play a pivotal role in the biocompatibility of blood-contacting materials. Moreover, the former strategies of creating a homing-like environment for cell adhesion and localization is preferred for an “off-the-shelf” product that does not require pre-seeding with ECs that often have limited proliferative potential due to the age of the patient and the time required for EC isolation, culture, seeding and preconditioning to ensure seeded cells do not slough off in a hemodynamic environment [64, 65]. Recent canine and baboon studies have suggested that immediate recapitulation of the EC layer in vitro or soon after in vivo implantation may not be required for short term (6month) graft performance [44], but is still thought to be essential for long term graft survival [66–68].
Smooth muscle cells (SMC) represent another important cellular component of the vascular wall. In normal pulsatile blood flow, the SMC layer contributes to the vascular tone and medial compliance of the vessel. However, in a variety of specific disease states, they are indicated in the progression of atherosclerosis through myointimal hyperplasia [69]. Although much work has focused on the use of luminal EC seeded grafts, SMC seeded grafts have shown the potential for improved host integration, increased medial contractility, and medial cellularization [70]. Additionally, several groups have shown the importance of SMC to aid in the development of the vascular media which is essential for biomechanical function of the vessel. Specifically, they have shown SMC secretion and rearrangement of the matrix into helical or circumferential orientations, more closely mimicking native structure [9, 71, 72]. Similar to the need to maintain a quiescent state for endothelial cells, the phenotypic expression of smooth muscle cells is critical to recapitulation of medial function. When SMCs are expanded in culture prior to seeding, they frequently adopt a non-contractile, proliferative, synthetic phenotype due to the loss of actin filaments [73, 74]. Development of a contractile SMC phenotype depends on a milieu of factors including local stress/strains, growth factors, and paracrine/ autocrine signaling [75, 76]. Correct phenotype is essential in preventing medial thickening and intimal hyperplasia from proliferative SMCs. The reader is referred to a review by Chan-Park et al for more details [77]. A variety of other cell types, both native and non-native to vasculature have been used for repopulation of tissue engineering vascular grafts. Of note, work with stem cells, including endothelial progenitor cells and mesenchymal stem cells, umbilical cord cells and peritoneal cells is discussed in detail herein.
Mediation of the immune response due to surgical trauma and foreign body reaction is critical to graft performance. Several groups have attempted to create functional tissue replacements that serve to passively prevent acute and chronic rejection. This has been done through the incorporation of bioactive materials, tailoring of degradation of biodegradable polymers to leach minimally cytotoxic degradation products, and incorporation of biomimetic moieties, such as collagen, elastin, and glycosaminoglycans [2, 3, 78–84]. However, there has been a recent trend to actively modulate the inflammatory response of tissue replacements by incorporation of moieties that strive to curtail adverse inflammatory responses such as neutrophil invasion, macrophage polarization and modulation of the adaptive immune response, notwithstanding the use of immunocompromised animal models [85–87]. Further, recent studies have demonstrated the importance of ensuring that the local environment of the graft is maintained to be non-inflammatory. Specific to macrophage polarization, Ariganello and colleagues have shown the utility of decellularized matrices to direct macrophage polarization to a non-inflammatory phenotype that would promote healing and resolution, instead of inflammation [88, 89]. The incorporation of bone marrow mesenchymal stem cells (BM-MSCs) within tissue engineered and biodegradable scaffolds has been widely reported. Specific to vascular grafts, bone marrow derived stem cells have been shown to differentiate into endothelial progenitor like-cells [90–93], as well as other vascular wall cellular constituents, smooth muscle cells [94, 95]. In addition to repopulating ECM-based scaffolds, MSC have also been shown to attenuate the inflammatory and immune responses associated with surgical trauma and implants. MSC have the ability to direct macrophage polarization toward an M2 phenotype (healing/ resolution) over an M1 phenotype (inflammatory), down-regulate MHC and co-stimulatory molecule expression, decrease inflammatory cytokine expression (TNF-α, IL-12, IFN-γ), increase anti-inflammatory cytokine expression (IL-10), promote T-regulatory cell proliferation and interfere with lymphocyte replication [96–101].
In vitro tests for TEBV include standard biocompatibility assays and, depending upon the design concept, may extend to consideration of cell supportive properties, hemocompatibility, and vasoactivity. Cytocompatibility is usually established with seeding of human EC, SMC and fibroblasts. To simulate features of the innate immune response, groups have used bio-similar environments with the addition of secretion products from inflammatory cells, such as macrophages and neutrophils, to simulate degradation in vivo and in vitro [5, 29, 53, 102–104]. In vitro hemocompatibility is typically determined with the use of whole blood clotting times, platelet adhesion and morphology, and activation states of inflammatory cells on vascular biomaterials in a variety of systems: static clotting time / platelet adhesion and morphology assays, flow loops and AV shunt models, preceding in vivo implants [5, 30, 105–108].
In vivo studies typically commence in rodents. Despite small vessels (< 1 mm), murine systems provide the potential to test constructs with human cells in nude [109] or severe combined immunodeficiency (SCID) mice [110]. Mouse models have been developed to incorporate intravital molecular imaging to track labeled cells and protease activity [109]. Rat models allow the assessment of human-cell constructs in (immune compromised) athymic animals [33], using slightly larger 1–2 mm inner diameter test vessels. A recent review highlights pitfalls to anticipate as investigators proceed to large animal models [12].
Evolving concepts and current status of TEBV technology
Collagen and other biopolymers
Traditional “cell-plus-scaffold” tissue engineering was first applied to blood vessel constructs by Weinberg and Bell in 1986 [111]. Employing a collagen gel cultured with SMC and EC, they observed a near-confluent and biologically active EC luminal surface. However, maximum burst pressures in the range of 400 mmHg necessitated the additional support of a Dacron mesh. Several other studies have used collagen or other biologically derived blood vessel constituents to recapitulate the features of a blood vessel in scaffolds, with limited success, given the weak nature of collagen gels [7, 112, 113]. Strategies incorporating cells, matrix components and intracellular biomolecules have been shown to improve the mechanical strength of collagen-based constructs by compaction and re-organization of collagen fibril architecture [114–118]. In particular, Seliktar et al. have demonstrated the ability of seeded cells and mechanical conditioning to rearrange collagen fibrils circumferentially, leading to increased strength [119]. Our research group has observed high burst pressures using a biomaterial composite consisting of crosslinked, oriented collagen microfibers reinforcing a matrix comprised of a recombinant elastin analogue [82].
Fibrin is of interest as an alternative biopolymer scaffold due to advantages including its natural role in wound healing, widespread clinical acceptance as a tissue sealant and the potential for generating an autologous biomaterial from the patients’ own blood [120]. Cummings et al. found that while fibrin vascular constructs were weaker and more extensible than collagen, fibrin-collagen composites displayed higher strength and gel compaction than collagen alone [121]. Fibrin gels have also been shown to stimulate SMC to synthesize elastin, an important component of the artery wall, which is neglected in many collagen-based TEBV [122]. Short segments (1.5 – 2.0 cm) of TEBV from fibrin cultured with either bone-marrow derived progenitor cells or SMC and seeded with EC demonstrated vasoactivity and have been implanted as interpositional grafts in the lamb external jugular vein [123, 124]. Recently, a bioreactor design capable of simultaneously processing six TEBV from fibrin with human dermal fibroblasts resulted in burst pressures of 1400 – 1600 mmHg after 5 to 7 weeks of culture [26]. The resulting compliance was 2–5 %/ mmHg and low suture retention strengths were compensated by the addition of polymeric cuffs from poly(lactic acid). Fibrin-based approaches have also been augmented through the addition of growth factors via sustained delivery systems in order to enhance and sustain cellular in-growth [125].
Biodegradable and bioresorbable synthetic polymers
In addition to biopolymers, biodegradable synthetic polymer scaffolds, such as polylactic acid (PLA), polyglycolic acid (PGA), polycaprolactone (PCL), polyurethanes (PU), and related copolymers or composites have been extensively studied [9, 72, 126–131]. Typically these scaffolds are pre-seeded with cells using a variety of techniques, including static seeding, dynamic seeding, vacuum aided seeding, or electrostatic seeding and conditioned in a bioreactor to ensure the cells can withstand physiologic blood flow [132–134]. In a well-studied example of the biodegradable polymer approach, Niklason and colleagues have fabricated TEBV using PGA seeded with SMC and cultured at 1–2% cyclic mechanical strain in a bioreactor for 7 to 8 weeks, followed by EC seeding [9]. In collaboration with Humacyte, Inc, this group has developed TEBV scaffolds generated from PGA seeded with allogeneic SMCs, conditioned in a bioreactor, and subsequently decellularized. Acellular specimens were studied in a baboon AV shunt model, and scaffolds with a luminal EC coating were investigated in a canine peripheral and coronary bypass. A potential disadvantage of this strategy is the relatively low levels of endothelialization (14±8%) [44]. Further, in a challenging model of porcine carotid grafting, they showed that decellularized, engineered grafts resisted both thrombosis and intimal hyperplasia. Head-to-head comparisons with autologous vein grafts showed that decellularized, engineered grafts had less neointima formation and superior patency rates after 30 days. The etiology of this advantage may be related to decreased activation of the mTOR pathway in engineered grafts as compared to vein, though this result remains to be confirmed in other studies (personal communication).
With respect to the proliferative capacity of the cells used in tissue engineered constructs, aging is associated with decreasing telomere length and directly related to decreased doubling capacity. To overcome this limitation, Poh et al. have demonstrated an increase in the population doublings of adult VSMCs through retroviral infection with the telomerase reverse transcriptase subunit (hTERT) [64]. Despite improvement, mechanical strength remained too low, potentially due to reduced collagen synthesis [135, 136]. To circumvent the challenges of SMCs, human mesenchymal stem cells (MSC) were used in an 8 week protocol involving proliferation and differentiation phases [80]. Collagen matrix synthesis and substantial conversion to an SMC phenotype were demonstrated, but burst pressures remained at approximately 400 mmHg. These biodegradable systems have confirmed that: (i) non-degraded polymer fragments can amplify stresses and dramatically compromise strength; (ii) collagen organization, as well as quantity, is required for strength; (iii) low compliance may be due to the absence of organized extracellular elastin sheets, as well as sub-physiologic SMC contractility [137, 138].
The vascular tissue engineering system developed by Shin’oka and colleagues uses similar biodegradable polymers. Employing porous ε-caprolactone and L-lactide copolymer reinforced with a PGA fabric, seeded with cultured autologous venous cells, they reported the first clinically effective TEBV implants [139]. By substituting autologous bone-marrow mononuclear cells (BMC), the cell culture step was avoided in subsequent implants [131]. Given the cost, delay, contamination potential, as well as dependence on xenogenic serums in culture medium, avoidance of prolonged in vitro culture represented a significant advantage. Notably, in these reports the TEBV implants repaired congenital defects in the pulmonary circulation of a pediatric population, while most TEBV applications must address more demanding mechanics of the arterial circulation, as well as the limitations of autologous cells obtained from elderly donors. Early efforts to adapt the technology to arterial implants have been reported [140]. Despite initial suggestions that BMCs differentiate and proliferate as the TEBV is incorporated [131, 141], recent analysis in SCID/beige mice found no evidence that the implanted cells persist longer than about one week [86]. BMCs appear to accelerate in vivo remodeling by paracrine recruitment of host monocytes. The authors also suggest that, in turn, accelerated monocyte infiltration triggered enhanced repopulation by host SMC and EC. Regardless of technique employed, the persistence of seeded cells and the ability to withstand hemodynamic forces (shear in the lumen or compressive in the vascular wall), remaining a desired phenotype, or differentiation along specific lineages (for stem cells), and maintainence of viable cytokine/chemokine expression, is critical to graft success [85, 134, 142].
Bioresorbable vascular grafts are incorporated into the recipient through host mediated degradation systems that include as enzymoloysis, oxidation and hydrolysis, while allowing for concomitant repopulation of the scaffold with native cells. Wolfe et al have shown that bioresorbable electrospun polydioxane (PDO) or PCL scaffolds elicited varying tissue factor expression when exposed to monocytes; demonstrating no greater risk of thrombotic occlusion than ePTFE [143]. Other groups have used a variety of bioresorbable polymeric constructs showing mechanical and biological utility [2, 144–146]. Campbell et al have developed an interesting technique wherein the host’s peritoneal cavity is used as a bioreactor to construct hierarchical tissue. They implanted silastic tubing in the peritoneal cavity of rats and rabbits for 2 weeks, which resulted in scaffolds that had developed layers of ECM, and were populated with myofibroblasts and mesothelium. 10–20 mm long grafts were subsequently implanted in the host animal, with greater than 4month patency. Their technique has been extended to the development of a variety of soft tissues including vas deferens, bladder and uterus [147, 148]. Vito’s group have developed a method for the in vivo or ex vivo stretching of arterial segments in suitable media conditions for generation of blood vessels. They have studied several aspects of the biomechanical regimes that effect remodeling and growth of vessels [149–152]. These studies were further carried into collagen based gels which have been seeded with cells and show morphological changes in ultrastructure and cellular behavior as a function of mechanical conditioning [119].
Cell-sheet tissue engineering
TEBV fabricated from cell sheet-based tissue engineering consist entirely of autologous cells and secreted matrix proteins. Initially, sheet-based TEBV consisted of SMC or fibroblasts cultured with ascorbic acid for approximately 30 days to form cohesive sheets [8]. The SMC sheet was wrapped about a tubular support to create the vessel media, matured for one week, wrapped with a fibroblast-sheet “adventitia,” matured for 7 weeks, and then seeded with EC. This process was replaced with a scheme consisting of a decellularized internal membrane fabricated from a fibroblast sheet, a living adventitial layer, and a seeded endothelial layer, requiring a total of 28 weeks of culture [33]. This design demonstrated favorable mechanics for implantation in the arterial circulation, and these TEBV have been successfully implanted as arteriovenous fistulas in high-risk patients [153]. This groundbreaking progress with a sheet-based tissue engineering system has been encouraging, although long culture times remain an important factor in keeping costs high and limiting application to non-urgent indications. Similar work has been done by other groups that have developed rolling techniques with localized regions of specific cells types or synthetic/biosynthetic materials such as PLLA, collagen and elastin [82, 85, 154].
Decellularized tissue scaffolds
This technique maintains the native extracellular matrix proteins that provide both structural integrity and instructive cues for cellular ingrowth. By incubating bone marrow derived cells in decellularized canine carotid arteries, Cho et al. demonstrated cellular incorporation into the scaffold and subsequent differentiation of these cells into endothelial and vascular smooth muscle cells and subsequently into 3 distinct vessel layers [94]. Zhou et al have shown that heparin and VEGF modified decellularized canine carotids grafts have higher 6 month patency rates than unmodified grafts [155]. In a similar study, Zhou et al showed that heparin immobilized on decellularized grafts implanted in rats supplemented with 14days of granulocyte-colony stimulating factor, had higher patency and lower neointima formation compared to controls; due to homing of circulating EPCs to the graft surface, demonstrating the potential for cytokine treatment post surgical intervention [156]. Further, potential changes in the long term mechanical response associated with decellularization protocols, specifically the shape of the pressure-diameter curves, and how they relate to compliance is of concern [157]. Other decellularized tubular conduits have been investigated for vascular tissue engineering. Specifically, aorta [158, 159], umbilical arteries [4], saphenous vein [46], ureter [160, 161], and small intestinal submucosa (SIS) [162, 163] to name a few. Cryolife, Inc, have constructed a vascular graft from decellularized bovine tissue that shows high patency in a canine model, with host cell repopulation of the prosthesis [164]. From the same company, Synergraft®, decellularized bovine ureter, has shown the potential to be used in humans as a blood vessel replacement. However, early results show the potential for aneurysm formation [165], poor long term patency as hemodialysis access shunts, (14% at 1year) [166], similar to ePTFE access grafts [167]; and infection and inflammation due to potential residual xenoantigen [168].
Translational challenges
At present, TEBV use in humans has required at least a bone marrow aspiration and brief cell seeding for pediatric pulmonary artery replacement and up to 28 weeks of maturation of rolled fibroblast sheets to withstand arterial pressures for use as arteriovenous conduits in patients requiring dialysis. Advanced cell or biomaterial technologies may drive the next generation of solutions. In particular, the recent recognition that BMC are likely to survive only transiently and cellular repopulation is driven by monocyte infiltration may suggest new cell and biomaterial strategies for TEBV researchers [86]. In addition, early results translating biodegradable polymer scaffold systems to the arterial circulation in mice suggest that protocols requiring as little as 1 week maturation in culture may be attainable [140].
Research timeline, regulatory, and economic issues
McAllister et al. have argued that the unique challenges inherent to translating cell-based therapies, including tissue-engineering, will benefit from the application of several distinct strategies [169]. In particular, the authors note that researchers should include an early focus on proof-of-principle with human cells and anticipate an extended (20 year) R&D timeline. A focus on modeling the cost-effectiveness of the technology is emphasized, but not until later in this timeline, as clinical trials are planned. Regulatory approval pathways for tissue-engineered products are still evolving, and the cost of quality assurance is expected to be a challenge given the small lot sizes of tissue-engineered products [170].
Summary and future directions
Small diameter arteries in the human body are prone to atherosclerosis depending on vessel location, size, hydrodynamic considerations, concomitant disease and a milieu of environmental and genetic factors. Peripheral artery disease is commonly treated with 3 main techniques when the patient does not respond to medication and exercise: (i) angioplasty and stenting, (ii) endarterectomy, and (iii) bypasss/interposition grafting.
The design of a tissue engineered vascular graft to supplant the diseased arteries’ function requires consideration of mechanical, biological and clinical factors that influence behavior in vitro and in vivo. To date, tissue engineered products have yet to replace the current “gold standard” of an autologous artery or vein. Much progress has been made in determining the key factors that contribute to the eventual success of a vessel graft. Mechanical considerations include (i) a sufficient burst pressure to prevent catastrophic failure of the vessel and long-term fatigue resistance, (ii) a suitable compliance that approximates that of the vessel to prevent mechanical mismatch, and (iii) a strong enough suture retention strength to permit implantation and tolerate hydrodynamic and mechanical forces at the anastomosis. Biological and clinical considerations include (i) generation of a non-fouling luminal surface to prevent from thrombosis, (ii) mediation of the immune response due to surgical trauma and potential graft rejection and regeneration, and (iii) evaluation in an in vivo environment.
Several groups have demonstrated the efficacies of various strategies that range from modifications of existing ePTFE/Dacron™ grafts to acellular/cellularized constructs to de novo engineering of tissue substitutes that mimic native vessels. TEBV derived from cell-sheet tissue engineering and degradable synthetic polymer scaffolding have demonstrated early clinical success and continued progress with several additional systems suggests that these technologies will continue to evolve. Clinical success will be determined by utilizing a “bottom-up” approach wherein recapitulation of the fundamental features of the vascular wall, incorporation of key elements that obviate thrombosis and acute graft failure, and potentially a cellular component that will direct the unavoidable inflammatory response towards healing, will be critical to the design of regenerative therapies for vascular tissue engineering.
REFERENCES
- 1.Lloyd-Jones D, et al. Heart disease and stroke statistics--2010 update: a report from the American Heart Association. Circulation. 2010;121(7):e46–e215. doi: 10.1161/CIRCULATIONAHA.109.192667. [DOI] [PubMed] [Google Scholar]
- 2.Ravi S, Qu Z, Chaikof EL. Polymeric materials for tissue engineering of arterial substitutes. Vascular. 2009;17(Suppl 1):S45–S54. doi: 10.2310/6670.2008.00084. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Mitchell SL, Niklason LE. Requirements for growing tissue-engineered vascular grafts. Cardiovasc Pathol. 2003;12(2):59–64. doi: 10.1016/s1054-8807(02)00183-7. [DOI] [PubMed] [Google Scholar]
- 4.Gui L, et al. Development of decellularized human umbilical arteries as small-diameter vascular grafts. Tissue Eng Part A. 2009;15(9):2665–2676. doi: 10.1089/ten.tea.2008.0526. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Motlagh D, et al. Hemocompatibility evaluation of poly(diol citrate) in vitro for vascular tissue engineering. J Biomed Mater Res A. 2007;82(4):907–916. doi: 10.1002/jbm.a.31211. [DOI] [PubMed] [Google Scholar]
- 6.Campbell GR, Campbell JH. Development of tissue engineered vascular grafts. Curr Pharm Biotechnol. 2007;8(1):43–50. doi: 10.2174/138920107779941426. [DOI] [PubMed] [Google Scholar]
- 7.Zhang WJ, et al. Tissue engineering of blood vessel. J Cell Mol Med. 2007;11(5):945–957. doi: 10.1111/j.1582-4934.2007.00099.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.L'Heureux N, et al. A completely biological tissue-engineered human blood vessel. FASEB J. 1998;12(1):47–56. doi: 10.1096/fasebj.12.1.47. [DOI] [PubMed] [Google Scholar]
- 9.Niklason LE, et al. Functional arteries grown in vitro. Science. 1999;284(5413):489–493. doi: 10.1126/science.284.5413.489. [DOI] [PubMed] [Google Scholar]
- 10.L'Heureux N, McAllister TN, de la Fuente LM. Tissue-engineered blood vessel for adult arterial revascularization. N Engl J Med. 2007;357(14):1451–1453. doi: 10.1056/NEJMc071536. [DOI] [PubMed] [Google Scholar]
- 11.ANSI/AAMI/ISO. Cardiovascular implants - tubular vascular prostheses. 2001 [Google Scholar]
- 12.Zilla P, Bezuidenhout D, Human P. Prosthetic vascular grafts: wrong models, wrong questions and no healing. Biomaterials. 2007;28(34):5009–5027. doi: 10.1016/j.biomaterials.2007.07.017. [DOI] [PubMed] [Google Scholar]
- 13.Konig G, et al. Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. Biomaterials. 2009;30(8):1542–1550. doi: 10.1016/j.biomaterials.2008.11.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Ku DN, et al. Hemodynamics of the normal human carotid bifurcation: in vitro and in vivo studies. Ultrasound Med Biol. 1985;11(1):13–26. doi: 10.1016/0301-5629(85)90003-1. [DOI] [PubMed] [Google Scholar]
- 15.Wootton DM, Ku DN. Fluid mechanics of vascular systems, diseases, and thrombosis. Annu Rev Biomed Eng. 1999;1:299–329. doi: 10.1146/annurev.bioeng.1.1.299. [DOI] [PubMed] [Google Scholar]
- 16.Ku DN, et al. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arteriosclerosis. 1985;5(3):293–302. doi: 10.1161/01.atv.5.3.293. [DOI] [PubMed] [Google Scholar]
- 17.Ku DN, Giddens DP. Pulsatile flow in a model carotid bifurcation. Arteriosclerosis. 1983;3(1):31–39. doi: 10.1161/01.atv.3.1.31. [DOI] [PubMed] [Google Scholar]
- 18.Goldstein LJ, et al. Carotid artery stenting is safe and associated with comparable outcomes in men and women. J Vasc Surg. 2009;49(2):315–323. doi: 10.1016/j.jvs.2008.08.110. discussion 323–4. [DOI] [PubMed] [Google Scholar]
- 19.Timaran CH, et al. Trends and outcomes of concurrent carotid revascularization and coronary bypass. J Vasc Surg. 2008;48(2):355–360. doi: 10.1016/j.jvs.2008.03.031. discussion 360–1. [DOI] [PubMed] [Google Scholar]
- 20.Dorafshar AH, et al. Interposition grafts for difficult carotid artery reconstruction: a 17-year experience. Ann Vasc Surg. 2008;22(1):63–69. doi: 10.1016/j.avsg.2007.07.038. [DOI] [PubMed] [Google Scholar]
- 21.Byrne J, Feustel P, Darling RC., 3rd Primary closure, routine patching, and eversion endarterectomy: what is the current state of the literature supporting use of these techniques? Semin Vasc Surg. 2007;20(4):226–235. doi: 10.1053/j.semvascsurg.2007.10.006. [DOI] [PubMed] [Google Scholar]
- 22.Solan A, Dahl SL, Niklason LE. Effects of mechanical stretch on collagen and cross-linking in engineered blood vessels. Cell Transplant. 2009;18(8):915–921. doi: 10.3727/096368909X471161. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Sarkar S, et al. Critical parameter of burst pressure measurement in development of bypass grafts is highly dependent on methodology used. J Vasc Surg. 2006;44(4):846–852. doi: 10.1016/j.jvs.2006.07.023. [DOI] [PubMed] [Google Scholar]
- 24.Isenberg BC, Tranquillo RT. Long-term cyclic distention enhances the mechanical properties of collagen-based media-equivalents. Ann Biomed Eng. 2003;31(8):937–949. doi: 10.1114/1.1590662. [DOI] [PubMed] [Google Scholar]
- 25.Ziegler T, Nerem RM. Tissue engineering a blood vessel: regulation of vascular biology by mechanical stresses. J Cell Biochem. 1994;56(2):204–209. doi: 10.1002/jcb.240560215. [DOI] [PubMed] [Google Scholar]
- 26.Syedain ZH, et al. Implantable arterial grafts from human fibroblasts and fibrin using a multi-graft pulsed flow-stretch bioreactor with noninvasive strength monitoring. Biomaterials. 32(3):714–722. doi: 10.1016/j.biomaterials.2010.09.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Wagenseil JE, Mecham RP. Vascular extracellular matrix and arterial mechanics. Physiol Rev. 2009;89(3):957–989. doi: 10.1152/physrev.00041.2008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Hong Y, et al. A small diameter, fibrous vascular conduit generated from a poly(ester urethane)urea and phospholipid polymer blend. Biomaterials. 2009;30(13):2457–2467. doi: 10.1016/j.biomaterials.2009.01.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Webb AR, et al. In vitro characterization of a compliant biodegradable scaffold with a novel bioreactor system. Ann Biomed Eng. 2007;35(8):1357–1367. doi: 10.1007/s10439-007-9304-z. [DOI] [PubMed] [Google Scholar]
- 30.L'Heureux N, et al. Technology insight: the evolution of tissue-engineered vascular grafts--from research to clinical practice. Nat Clin Pract Cardiovasc Med. 2007;4(7):389–395. doi: 10.1038/ncpcardio0930. [DOI] [PubMed] [Google Scholar]
- 31.Soletti L, et al. A bilayered elastomeric scaffold for tissue engineering of small diameter vascular grafts. Acta Biomater. 6(1):110–122. doi: 10.1016/j.actbio.2009.06.026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Zaucha MT, et al. A novel cylindrical biaxial computer-controlled bioreactor and biomechanical testing device for vascular tissue engineering. Tissue Eng Part A. 2009;15(11):3331–3340. doi: 10.1089/ten.tea.2008.0369. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.L'Heureux N, et al. Human tissue-engineered blood vessels for adult arterial revascularization. Nat Med. 2006;12(3):361–365. doi: 10.1038/nm1364. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Drilling S, Gaumer J, Lannutti J. Fabrication of burst pressure competent vascular grafts via electrospinning: effects of microstructure. J Biomed Mater Res A. 2009;88(4):923–934. doi: 10.1002/jbm.a.31926. [DOI] [PubMed] [Google Scholar]
- 35.Wang S, et al. Fabrication and properties of the electrospun polylactide/silk fibroin-gelatin composite tubular scaffold. Biomacromolecules. 2009;10(8):2240–2244. doi: 10.1021/bm900416b. [DOI] [PubMed] [Google Scholar]
- 36.Nieponice A, et al. Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding technique. Biomaterials. 2008;29(7):825–833. doi: 10.1016/j.biomaterials.2007.10.044. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Shaw JA, et al. Determinants of coronary artery compliance in subjects with and without angiographic coronary artery disease. J Am Coll Cardiol. 2002;39(10):1637–1643. doi: 10.1016/s0735-1097(02)01842-9. [DOI] [PubMed] [Google Scholar]
- 38.van Andel CJ, Pistecky PV, Borst C. Mechanical properties of porcine and human arteries: implications for coronary anastomotic connectors. Ann Thorac Surg. 2003;76(1):58–64. doi: 10.1016/s0003-4975(03)00263-7. discussion 64–5. [DOI] [PubMed] [Google Scholar]
- 39.Roeder R, et al. Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts. J Biomed Mater Res. 1999;47(1):65–70. doi: 10.1002/(sici)1097-4636(199910)47:1<65::aid-jbm9>3.0.co;2-f. [DOI] [PubMed] [Google Scholar]
- 40.Laurent S, et al. Carotid artery distensibility and distending pressure in hypertensive humans. Hypertension. 1994;23(6 Pt 2):878–883. doi: 10.1161/01.hyp.23.6.878. [DOI] [PubMed] [Google Scholar]
- 41.Tai NR, et al. In vivo femoropopliteal arterial wall compliance in subjects with and without lower limb vascular disease. J Vasc Surg. 1999;30(5):936–945. doi: 10.1016/s0741-5214(99)70020-0. [DOI] [PubMed] [Google Scholar]
- 42.Greenwald SE, Berry CL. Improving vascular grafts: the importance of mechanical and haemodynamic properties. J Pathol. 2000;190(3):292–299. doi: 10.1002/(SICI)1096-9896(200002)190:3<292::AID-PATH528>3.0.CO;2-S. [DOI] [PubMed] [Google Scholar]
- 43.Wise SG, et al. A multilayered synthetic human elastin/polycaprolactone hybrid vascular graft with tailored mechanical properties. Acta Biomater. 2011;7(1):295–303. doi: 10.1016/j.actbio.2010.07.022. [DOI] [PubMed] [Google Scholar]
- 44.Dahl SL, et al. Readily available tissue-engineered vascular grafts. Sci Transl Med. 2011;3(68) doi: 10.1126/scitranslmed.3001426. 68ra9. [DOI] [PubMed] [Google Scholar]
- 45.Sarkar S, et al. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. Eur J Vasc Endovasc Surg. 2006;31(6):627–636. doi: 10.1016/j.ejvs.2006.01.006. [DOI] [PubMed] [Google Scholar]
- 46.Schaner PJ, et al. Decellularized vein as a potential scaffold for vascular tissue engineering. J Vasc Surg. 2004;40(1):146–153. doi: 10.1016/j.jvs.2004.03.033. [DOI] [PubMed] [Google Scholar]
- 47.Tai NR, et al. Compliance properties of conduits used in vascular reconstruction. Br J Surg. 2000;87(11):1516–1524. doi: 10.1046/j.1365-2168.2000.01566.x. [DOI] [PubMed] [Google Scholar]
- 48.Mine Y, et al. Suture retention strength of expanded polytetrafluoroethylene (ePTFE) graft. Acta Med Okayama. 2010;64(2):121–128. doi: 10.18926/AMO/32846. [DOI] [PubMed] [Google Scholar]
- 49.Isaka M, et al. Experimental study on stability of a high-porosity expanded polytetrafluoroethylene graft in dogs. Ann Thorac Cardiovasc Surg. 2006;12(1):37–41. [PubMed] [Google Scholar]
- 50.ASTM Committee F-4 on Medical Surgical, MD. Vascular graft update : safety and performance. Philadelphia, Penn.: ASTM; 1986. [Google Scholar]
- 51.Arrigoni C, Camozzi D, Remuzzi A. Vascular tissue engineering. Cell Transplant. 2006;15(Suppl 1):S119–S125. doi: 10.3727/000000006783982430. [DOI] [PubMed] [Google Scholar]
- 52.Fidkowski C, et al. Endothelialized microvasculature based on a biodegradable elastomer. Tissue Eng. 2005;11(1–2):302–309. doi: 10.1089/ten.2005.11.302. [DOI] [PubMed] [Google Scholar]
- 53.Kaushiva A, et al. A biodegradable vascularizing membrane: a feasibility study. Acta Biomater. 2007;3(5):631–642. doi: 10.1016/j.actbio.2007.03.003. [DOI] [PubMed] [Google Scholar]
- 54.Zetrenne E, et al. Prosthetic vascular graft infection: a multi-center review of surgical management. Yale J Biol Med. 2007;80(3):113–121. [PMC free article] [PubMed] [Google Scholar]
- 55.Torikai K, et al. A self-renewing, tissue-engineered vascular graft for arterial reconstruction. J Thorac Cardiovasc Surg. 2008;136(1):37–45. doi: 10.1016/j.jtcvs.2007.06.039. 45 e1. [DOI] [PubMed] [Google Scholar]
- 56.Wang C, et al. A new vascular prosthesis coated with polyamino-acid urethane copolymer (PAU) to enhance endothelialization. J Biomed Mater Res. 2002;62(3):315–322. doi: 10.1002/jbm.10137. [DOI] [PubMed] [Google Scholar]
- 57.Yow KH, et al. Tissue engineering of vascular conduits. Br J Surg. 2006;93(6):652–661. doi: 10.1002/bjs.5343. [DOI] [PubMed] [Google Scholar]
- 58.Yu XX, Wan CX, Chen HQ. Preparation and endothelialization of decellularised vascular scaffold for tissue-engineered blood vessel. J Mater Sci Mater Med. 2008;19(1):319–326. doi: 10.1007/s10856-007-3157-8. [DOI] [PubMed] [Google Scholar]
- 59.Li C, Hill A, Imran M. In vitro and in vivo studies of ePTFE vascular grafts treated with P15 peptide. J Biomater Sci Polym Ed. 2005;16(7):875–891. doi: 10.1163/1568562054255754. [DOI] [PubMed] [Google Scholar]
- 60.Hancock WW. Delayed xenograft rejection. World J Surg. 1997;21(9):917–923. doi: 10.1007/s002689900327. [DOI] [PubMed] [Google Scholar]
- 61.Sarkar S, et al. Addressing thrombogenicity in vascular graft construction. J Biomed Mater Res B Appl Biomater. 2007;82(1):100–108. doi: 10.1002/jbm.b.30710. [DOI] [PubMed] [Google Scholar]
- 62.Salom RN, Maguire JA, Hancock WW. Endothelial activation and cytokine expression in human acute cardiac allograft rejection. Pathology. 1998;30(1):24–29. doi: 10.1080/00313029800169625. [DOI] [PubMed] [Google Scholar]
- 63.Quillard T, et al. Impaired Notch4 activity elicits endothelial cell activation and apoptosis: implication for transplant arteriosclerosis. Arterioscler Thromb Vasc Biol. 2008;28(12):2258–2265. doi: 10.1161/ATVBAHA.108.174995. [DOI] [PubMed] [Google Scholar]
- 64.Poh M, et al. Blood vessels engineered from human cells. Lancet. 2005;365(9477):2122–2124. doi: 10.1016/S0140-6736(05)66735-9. [DOI] [PubMed] [Google Scholar]
- 65.Klinger RY, et al. Relevance and safety of telomerase for human tissue engineering. Proc Natl Acad Sci U S A. 2006;103(8):2500–2505. doi: 10.1073/pnas.0508184103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Deutsch M, et al. Long-term experience in autologous in vitro endothelialization of infrainguinal ePTFE grafts. J Vasc Surg. 2009;49(2):352–362. doi: 10.1016/j.jvs.2008.08.101. discussion 362. [DOI] [PubMed] [Google Scholar]
- 67.Zilla P, Deutsch M, Meinhart J. Endothelial cell transplantation. Semin Vasc Surg. 1999;12(1):52–63. [PubMed] [Google Scholar]
- 68.Meinhart J, Deutsch M, Zilla P. Eight years of clinical endothelial cell transplantation. Closing the gap between prosthetic grafts and vein grafts. ASAIO J. 1997;43(5):M515–M521. [PubMed] [Google Scholar]
- 69.Daniel JM, Sedding DG. Circulating smooth muscle progenitor cells in arterial remodeling. J Mol Cell Cardiol. 2011;50(2):273–279. doi: 10.1016/j.yjmcc.2010.10.030. [DOI] [PubMed] [Google Scholar]
- 70.Neff LP, et al. Vascular smooth muscle enhances functionality of tissue-engineered blood vessels in vivo. J Vasc Surg. 2011;53(2):426–434. doi: 10.1016/j.jvs.2010.07.054. [DOI] [PubMed] [Google Scholar]
- 71.Yazdani SK, et al. Smooth muscle cell seeding of decellularized scaffolds: the importance of bioreactor preconditioning to development of a more native architecture for tissue-engineered blood vessels. Tissue Eng Part A. 2009;15(4):827–840. doi: 10.1089/ten.tea.2008.0092. [DOI] [PubMed] [Google Scholar]
- 72.Iwasaki K, et al. Bioengineered three-layered robust and elastic artery using hemodynamically-equivalent pulsatile bioreactor. Circulation. 2008;118(14 Suppl):S52–S57. doi: 10.1161/CIRCULATIONAHA.107.757369. [DOI] [PubMed] [Google Scholar]
- 73.Gan Q, et al. Smooth muscle cells and myofibroblasts use distinct transcriptional mechanisms for smooth muscle alpha-actin expression. Circ Res. 2007;101(9):883–892. doi: 10.1161/CIRCRESAHA.107.154831. [DOI] [PubMed] [Google Scholar]
- 74.Owens GK. Regulation of differentiation of vascular smooth muscle cells. Physiol Rev. 1995;75(3):487–517. doi: 10.1152/physrev.1995.75.3.487. [DOI] [PubMed] [Google Scholar]
- 75.Owens GK. Role of mechanical strain in regulation of differentiation of vascular smooth muscle cells. Circ Res. 1996;79(5):1054–1055. doi: 10.1161/01.res.79.5.1054. [DOI] [PubMed] [Google Scholar]
- 76.Owens GK. Molecular control of vascular smooth muscle cell differentiation and phenotypic plasticity. Novartis Found Symp. 2007;283:174–191. doi: 10.1002/9780470319413.ch14. discussion 191–3, 238–41. [DOI] [PubMed] [Google Scholar]
- 77.Chan-Park MB, et al. Biomimetic control of vascular smooth muscle cell morphology and phenotype for functional tissue-engineered small-diameter blood vessels. J Biomed Mater Res A. 2009;88(4):1104–1121. doi: 10.1002/jbm.a.32318. [DOI] [PubMed] [Google Scholar]
- 78.Ball SG, Shuttleworth CA, Kielty CM. Mesenchymal stem cells and neovascularization: role of platelet-derived growth factor receptors. J Cell Mol Med. 2007;11(5):1012–1030. doi: 10.1111/j.1582-4934.2007.00120.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Kielty CM, et al. Applying elastic fibre biology in vascular tissue engineering. Philos Trans R Soc Lond B Biol Sci. 2007;362(1484):1293–1312. doi: 10.1098/rstb.2007.2134. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.Gong Z, Niklason LE. Small-diameter human vessel wall engineered from bone marrow-derived mesenchymal stem cells (hMSCs) FASEB J. 2008;22(6):1635–1648. doi: 10.1096/fj.07-087924. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Niklason LE. Techview: medical technology. Replacement arteries made to order. Science. 1999;286(5444):1493–1494. doi: 10.1126/science.286.5444.1493. [DOI] [PubMed] [Google Scholar]
- 82.Caves JM, et al. The use of microfiber composites of elastin-like protein matrix reinforced with synthetic collagen in the design of vascular grafts. Biomaterials. 31(27):7175–7182. doi: 10.1016/j.biomaterials.2010.05.014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Allen JB, et al. Toward engineering a human neoendothelium with circulating progenitor cells. Stem Cells. 28(2):318–328. doi: 10.1002/stem.275. [DOI] [PubMed] [Google Scholar]
- 84.Allen J, et al. Characterization of porcine circulating progenitor cells: toward a functional endothelium. Tissue Eng Part A. 2008;14(1):183–194. doi: 10.1089/ten.a.2007.0265. [DOI] [PubMed] [Google Scholar]
- 85.Hashi CK, et al. Antithrombogenic property of bone marrow mesenchymal stem cells in nanofibrous vascular grafts. Proc Natl Acad Sci U S A. 2007;104(29):11915–11920. doi: 10.1073/pnas.0704581104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86.Roh JD, et al. Tissue-engineered vascular grafts transform into mature blood vessels via an inflammation-mediated process of vascular remodeling. Proc Natl Acad Sci U S A. 107(10):4669–4674. doi: 10.1073/pnas.0911465107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87.Campoccia D, et al. Human neutrophil chemokinesis and polarization induced by hyaluronic acid derivatives. Biomaterials. 1993;14(15):1135–1139. doi: 10.1016/0142-9612(93)90156-v. [DOI] [PubMed] [Google Scholar]
- 88.Ariganello MB, et al. Macrophage differentiation and polarization on a decellularized pericardial biomaterial. Biomaterials. 32(2):439–449. doi: 10.1016/j.biomaterials.2010.09.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89.Ariganello MB, Labow RS, Lee JM. In vitro response of monocyte-derived macrophages to a decellularized pericardial biomaterial. J Biomed Mater Res A. 93(1):280–288. doi: 10.1002/jbm.a.32554. [DOI] [PubMed] [Google Scholar]
- 90.Walter DH, et al. Statin therapy accelerates reendothelialization: a novel effect involving mobilization and incorporation of bone marrow-derived endothelial progenitor cells. Circulation. 2002;105(25):3017–3024. doi: 10.1161/01.cir.0000018166.84319.55. [DOI] [PubMed] [Google Scholar]
- 91.Iwakura A, et al. Estrogen-mediated, endothelial nitric oxide synthase-dependent mobilization of bone marrow-derived endothelial progenitor cells contributes to reendothelialization after arterial injury. Circulation. 2003;108(25):3115–3121. doi: 10.1161/01.CIR.0000106906.56972.83. [DOI] [PubMed] [Google Scholar]
- 92.Werner N, et al. Intravenous transfusion of endothelial progenitor cells reduces neointima formation after vascular injury. Circ Res. 2003;93(2):e17–e24. doi: 10.1161/01.RES.0000083812.30141.74. [DOI] [PubMed] [Google Scholar]
- 93.Urbich C, Dimmeler S. Endothelial progenitor cells: characterization and role in vascular biology. Circ Res. 2004;95(4):343–353. doi: 10.1161/01.RES.0000137877.89448.78. [DOI] [PubMed] [Google Scholar]
- 94.Cho SW, et al. Small-diameter blood vessels engineered with bone marrow-derived cells. Ann Surg. 2005;241(3):506–515. doi: 10.1097/01.sla.0000154268.12239.ed. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 95.Gong Z, et al. Influence of culture medium on smooth muscle cell differentiation from human bone marrow-derived mesenchymal stem cells. Tissue Eng Part A. 2009;15(2):319–330. doi: 10.1089/ten.tea.2008.0161. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 96.Shi Y, et al. Mesenchymal stem cells: a new strategy for immunosuppression and tissue repair. Cell Res. 20(5):510–518. doi: 10.1038/cr.2010.44. [DOI] [PubMed] [Google Scholar]
- 97.Uccelli A, Pistoia V, Moretta L. Mesenchymal stem cells: a new strategy for immunosuppression? Trends Immunol. 2007;28(5):219–226. doi: 10.1016/j.it.2007.03.001. [DOI] [PubMed] [Google Scholar]
- 98.Jorgensen C. Mesenchymal stem cells immunosuppressive properties: is it specific to bone marrow-derived cells? Stem Cell Res Ther. 1(2):15. doi: 10.1186/scrt15. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 99.Salem HK, Thiemermann C. Mesenchymal stromal cells: current understanding and clinical status. Stem Cells. 28(3):585–596. doi: 10.1002/stem.269. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100.Gotherstrom C. Immunomodulation by multipotent mesenchymal stromal cells. Transplantation. 2007;84(1 Suppl):S35–S37. doi: 10.1097/01.tp.0000269200.67707.c8. [DOI] [PubMed] [Google Scholar]
- 101.Noel D, et al. Multipotent mesenchymal stromal cells and immune tolerance. Leuk Lymphoma. 2007;48(7):1283–1289. doi: 10.1080/10428190701361869. [DOI] [PubMed] [Google Scholar]
- 102.Zhang X, Thomas V, Vohra YK. In vitro biodegradation of designed tubular scaffolds of electrospun protein/polyglyconate blend fibers. J Biomed Mater Res B Appl Biomater. 2009;89(1):135–147. doi: 10.1002/jbm.b.31196. [DOI] [PubMed] [Google Scholar]
- 103.Shaikh FM, et al. Fibrin: a natural biodegradable scaffold in vascular tissue engineering. Cells Tissues Organs. 2008;188(4):333–346. doi: 10.1159/000139772. [DOI] [PubMed] [Google Scholar]
- 104.Sutherland K, et al. Degradation of biomaterials by phagocyte-derived oxidants. J Clin Invest. 1993;92(5):2360–2367. doi: 10.1172/JCI116841. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105.Motlagh D, et al. Hemocompatibility evaluation of poly(glycerol-sebacate) in vitro for vascular tissue engineering. Biomaterials. 2006;27(24):4315–4324. doi: 10.1016/j.biomaterials.2006.04.010. [DOI] [PubMed] [Google Scholar]
- 106.Amarnath LP, Srinivas A, Ramamurthi A. In vitro hemocompatibility testing of UV-modified hyaluronan hydrogels. Biomaterials. 2006;27(8):1416–1424. doi: 10.1016/j.biomaterials.2005.08.008. [DOI] [PubMed] [Google Scholar]
- 107.Chuang TW, Masters KS. Regulation of polyurethane hemocompatibility and endothelialization by tethered hyaluronic acid oligosaccharides. Biomaterials. 2009;30(29):5341–5351. doi: 10.1016/j.biomaterials.2009.06.029. [DOI] [PubMed] [Google Scholar]
- 108.Goodman SL. Sheep, pig, and human platelet-material interactions with model cardiovascular biomaterials. J Biomed Mater Res. 1999;45(3):240–250. doi: 10.1002/(sici)1097-4636(19990605)45:3<240::aid-jbm12>3.0.co;2-c. [DOI] [PubMed] [Google Scholar]
- 109.Hjortnaes J, et al. Intravital Molecular Imaging of Small-Diameter Tissue-Engineered Vascular Grafts: A Feasibility Study. Tissue Eng Part C Methods. 2009 doi: 10.1089/ten.tec.2009.0466. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110.Lopez-Soler RI, et al. Development of a mouse model for evaluation of small diameter vascular grafts. J Surg Res. 2007;139(1):1–6. doi: 10.1016/j.jss.2006.07.040. [DOI] [PubMed] [Google Scholar]
- 111.Weinberg CB, Bell E. A blood vessel model constructed from collagen and cultured vascular cells. Science. 1986;231(4736):397–400. doi: 10.1126/science.2934816. [DOI] [PubMed] [Google Scholar]
- 112.Zorlutuna P, Elsheikh A, Hasirci V. Nanopatterning of collagen scaffolds improve the mechanical properties of tissue engineered vascular grafts. Biomacromolecules. 2009;10(4):814–821. doi: 10.1021/bm801307y. [DOI] [PubMed] [Google Scholar]
- 113.Chaouat M, et al. The evaluation of a small-diameter polysaccharide-based arterial graft in rats. Biomaterials. 2006;27(32):5546–5553. doi: 10.1016/j.biomaterials.2006.06.032. [DOI] [PubMed] [Google Scholar]
- 114.Lund AW, Stegemann JP, Plopper GE. Inhibition of ERK promotes collagen gel compaction and fibrillogenesis to amplify the osteogenesis of human mesenchymal stem cells in three-dimensional collagen I culture. Stem Cells Dev. 2009;18(2):331–341. doi: 10.1089/scd.2008.0075. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 115.Qi J, et al. Modulation of collagen gel compaction by extracellular ATP is MAPK and NF-kappaB pathways dependent. Exp Cell Res. 2009;315(11):1990–2000. doi: 10.1016/j.yexcr.2009.02.012. [DOI] [PubMed] [Google Scholar]
- 116.Fernandez P, Bausch AR. The compaction of gels by cells: a case of collective mechanical activity. Integr Biol (Camb) 2009;1(3):252–259. doi: 10.1039/b822897c. [DOI] [PubMed] [Google Scholar]
- 117.Jiang Z, et al. Established neointimal hyperplasia in vein grafts expands via TGF-beta-mediated progressive fibrosis. Am J Physiol Heart Circ Physiol. 2009;297(4):H1200–H1207. doi: 10.1152/ajpheart.00268.2009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Zhou M, et al. [Constructing a small-diameter decellularized vascular graft pre-loaded with bFGF] Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008;22(3):370–375. [PubMed] [Google Scholar]
- 119.Seliktar D, et al. Dynamic mechanical conditioning of collagen-gel blood vessel constructs induces remodeling in vitro. Ann Biomed Eng. 2000;28(4):351–362. doi: 10.1114/1.275. [DOI] [PubMed] [Google Scholar]
- 120.Grassl ED, Oegema TR, Tranquillo RT. Fibrin as an alternative biopolymer to type-I collagen for the fabrication of a media equivalent. J Biomed Mater Res. 2002;60(4):607–612. doi: 10.1002/jbm.10107. [DOI] [PubMed] [Google Scholar]
- 121.Cummings CL, et al. Properties of engineered vascular constructs made from collagen, fibrin, and collagen-fibrin mixtures. Biomaterials. 2004;25(17):3699–3706. doi: 10.1016/j.biomaterials.2003.10.073. [DOI] [PubMed] [Google Scholar]
- 122.Long JL, Tranquillo RT. Elastic fiber production in cardiovascular tissue-equivalents. Matrix Biol. 2003;22(4):339–350. doi: 10.1016/s0945-053x(03)00052-0. [DOI] [PubMed] [Google Scholar]
- 123.Swartz DD, Russell JA, Andreadis ST. Engineering of fibrin-based functional and implantable small-diameter blood vessels. Am J Physiol Heart Circ Physiol. 2005;288(3):H1451–H1460. doi: 10.1152/ajpheart.00479.2004. [DOI] [PubMed] [Google Scholar]
- 124.Liu JY, et al. Functional tissue-engineered blood vessels from bone marrow progenitor cells. Cardiovasc Res. 2007;75(3):618–628. doi: 10.1016/j.cardiores.2007.04.018. [DOI] [PubMed] [Google Scholar]
- 125.Ehrbar M, et al. Cell-demanded liberation of VEGF121 from fibrin implants induces local and controlled blood vessel growth. Circ Res. 2004;94(8):1124–1132. doi: 10.1161/01.RES.0000126411.29641.08. [DOI] [PubMed] [Google Scholar]
- 126.Soletti L, et al. A bilayered elastomeric scaffold for tissue engineering of small diameter vascular grafts. Acta Biomater. 2009 doi: 10.1016/j.actbio.2009.06.026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 127.Pektok E, et al. Degradation and healing characteristics of small-diameter poly(epsilon-caprolactone) vascular grafts in the rat systemic arterial circulation. Circulation. 2008;118(24):2563–2570. doi: 10.1161/CIRCULATIONAHA.108.795732. [DOI] [PubMed] [Google Scholar]
- 128.Stekelenburg M, et al. Dynamic straining combined with fibrin gel cell seeding improves strength of tissue-engineered small-diameter vascular grafts. Tissue Eng Part A. 2009;15(5):1081–1089. doi: 10.1089/ten.tea.2008.0183. [DOI] [PubMed] [Google Scholar]
- 129.Zhang L, et al. A novel small-diameter vascular graft: in vivo behavior of biodegradable three-layered tubular scaffolds. Biotechnol Bioeng. 2008;99(4):1007–1015. doi: 10.1002/bit.21629. [DOI] [PubMed] [Google Scholar]
- 130.He W, et al. Tubular nanofiber scaffolds for tissue engineered small-diameter vascular grafts. J Biomed Mater Res A. 2009;90(1):205–216. doi: 10.1002/jbm.a.32081. [DOI] [PubMed] [Google Scholar]
- 131.Shin'oka T, et al. Midterm clinical result of tissue-engineered vascular autografts seeded with autologous bone marrow cells. J Thorac Cardiovasc Surg. 2005;129(6):1330–1338. doi: 10.1016/j.jtcvs.2004.12.047. [DOI] [PubMed] [Google Scholar]
- 132.Villalona GA, et al. Cell-seeding techniques in vascular tissue engineering. Tissue Eng Part B Rev. 16(3):341–350. doi: 10.1089/ten.teb.2009.0527. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 133.Kibbe MR, et al. Citric acid-based elastomers provide a biocompatible interface for vascular grafts. J Biomed Mater Res A. 93(1):314–324. doi: 10.1002/jbm.a.32537. [DOI] [PubMed] [Google Scholar]
- 134.Bowlin GL, et al. The persistence of electrostatically seeded endothelial cells lining a small diameter expanded polytetrafluoroethylene vascular graft. J Biomater Appl. 2001;16(2):157–173. doi: 10.1106/NCQT-JFV9-2EQ1-EBGU. [DOI] [PubMed] [Google Scholar]
- 135.McKee JA, et al. Human arteries engineered in vitro. EMBO Rep. 2003;4(6):633–638. doi: 10.1038/sj.embor.embor847. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 136.Petersen TH, et al. Utility of telomerase-pot1 fusion protein in vascular tissue engineering. Cell Transplant. 19(1):79–87. doi: 10.3727/096368909X478650. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 137.Dahl SL, et al. Mechanical properties and compositions of tissue engineered and native arteries. Ann Biomed Eng. 2007;35(3):348–355. doi: 10.1007/s10439-006-9226-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138.Dahl SL, Vaughn ME, Niklason LE. An ultrastructural analysis of collagen in tissue engineered arteries. Ann Biomed Eng. 2007;35(10):1749–1755. doi: 10.1007/s10439-007-9340-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 139.Shin'oka T, Imai Y, Ikada Y. Transplantation of a tissue-engineered pulmonary artery. N Engl J Med. 2001;344(7):532–533. doi: 10.1056/NEJM200102153440717. [DOI] [PubMed] [Google Scholar]
- 140.Mirensky TL, et al. Tissue-engineered arterial grafts: long-term results after implantation in a small animal model. J Pediatr Surg. 2009;44(6):1127–1132. doi: 10.1016/j.jpedsurg.2009.02.035. discussion 1132–3. [DOI] [PubMed] [Google Scholar]
- 141.Matsumura G, et al. First evidence that bone marrow cells contribute to the construction of tissue-engineered vascular autografts in vivo. Circulation. 2003;108(14):1729–1734. doi: 10.1161/01.CIR.0000092165.32213.61. [DOI] [PubMed] [Google Scholar]
- 142.Sussman MA. Showing up isn't enough for vascularization: persistence is essential. Circ Res. 2008;103(11):1200–120l. doi: 10.1161/CIRCRESAHA.108.189076. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 143.Wolfe PS, et al. Evaluation of thrombogenic potential of electrospun bioresorbable vascular graft materials: acute monocyte tissue factor expression. J Biomed Mater Res A. 2010;92(4):1321–1328. doi: 10.1002/jbm.a.32458. [DOI] [PubMed] [Google Scholar]
- 144.Sell SA, et al. Electrospun polydioxanone-elastin blends: potential for bioresorbable vascular grafts. Biomed Mater. 2006;1(2):72–80. doi: 10.1088/1748-6041/1/2/004. [DOI] [PubMed] [Google Scholar]
- 145.Sell SA, et al. Electrospinning of collagen/biopolymers for regenerative medicine and cardiovascular tissue engineering. Adv Drug Deliv Rev. 2009;61(12):1007–1019. doi: 10.1016/j.addr.2009.07.012. [DOI] [PubMed] [Google Scholar]
- 146.Opitz F, et al. Tissue engineering of aortic tissue: dire consequence of suboptimal elastic fiber synthesis in vivo. Cardiovasc Res. 2004;63(4):719–730. doi: 10.1016/j.cardiores.2004.05.002. [DOI] [PubMed] [Google Scholar]
- 147.Campbell GR, et al. The peritoneal cavity as a bioreactor for tissue engineering visceral organs: bladder, uterus and vas deferens. J Tissue Eng Regen Med. 2008;2(1):50–60. doi: 10.1002/term.66. [DOI] [PubMed] [Google Scholar]
- 148.Campbell JH, Efendy JL, Campbell GR. Novel vascular graft grown within recipient's own peritoneal cavity. Circ Res. 1999;85(12):1173–1178. doi: 10.1161/01.res.85.12.1173. [DOI] [PubMed] [Google Scholar]
- 149.Rachev A, Dominguez Z, Vito R. System and method for investigating arterial remodeling. Journal of biomechanical engineering. 2009;131:104501. doi: 10.1115/1.3207014. [DOI] [PubMed] [Google Scholar]
- 150.Davis NP, et al. Sustained axial loading lengthens arteries in organ culture. Ann Biomed Eng. 2005;33(7):867–877. doi: 10.1007/s10439-005-3488-x. [DOI] [PubMed] [Google Scholar]
- 151.Han HC, Ku DN, Vito RP. Arterial wall adaptation under elevated longitudinal stretch in organ culture. Ann Biomed Eng. 2003;31(4):403–411. doi: 10.1114/1.1561291. [DOI] [PubMed] [Google Scholar]
- 152.Wayman BH, et al. Arteries respond to independent control of circumferential and shear stress in organ culture. Ann Biomed Eng. 2008;36(5):673–684. doi: 10.1007/s10439-008-9435-x. [DOI] [PubMed] [Google Scholar]
- 153.McAllister TN, et al. Effectiveness of haemodialysis access with an autologous tissue-engineered vascular graft: a multicentre cohort study. Lancet. 2009;373(9673):1440–1446. doi: 10.1016/S0140-6736(09)60248-8. [DOI] [PubMed] [Google Scholar]
- 154.Gauvin R, et al. A novel single-step self-assembly approach for the fabrication of tissue-engineered vascular constructs. Tissue Eng Part A. 16(5):1737–1747. doi: 10.1089/ten.TEA.2009.0313. [DOI] [PubMed] [Google Scholar]
- 155.Zhou M, et al. Development and validation of small-diameter vascular tissue from a decellularized scaffold coated with heparin and vascular endothelial growth factor. Artif Organs. 2009;33(3):230–239. doi: 10.1111/j.1525-1594.2009.00713.x. [DOI] [PubMed] [Google Scholar]
- 156.Zhou M, et al. Beneficial effects of granulocyte-colony stimulating factor on small-diameter heparin immobilized decellularized vascular graft. J Biomed Mater Res A. 2010;95(2):600–610. doi: 10.1002/jbm.a.32864. [DOI] [PubMed] [Google Scholar]
- 157.Fitzpatrick JC, Clark PM, Capaldi FM. Effect of decellularization protocol on the mechanical behavior of porcine descending aorta. Int J Biomater. 2010;2010 doi: 10.1155/2010/620503. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 158.Liu GF, et al. Decellularized aorta of fetal pigs as a potential scaffold for small diameter tissue engineered vascular graft. Chin Med J (Engl) 2008;121(15):1398–1406. [PubMed] [Google Scholar]
- 159.Heidenhain C, et al. Polymer coating of porcine decellularized and cross-linked aortic grafts. J Biomed Mater Res B Appl Biomater. 2010;94(1):256–263. doi: 10.1002/jbm.b.31650. [DOI] [PubMed] [Google Scholar]
- 160.Derham C, et al. Tissue engineering small-diameter vascular grafts: preparation of a biocompatible porcine ureteric scaffold. Tissue Eng Part A. 2008;14(11):1871–1882. doi: 10.1089/ten.tea.2007.0103. [DOI] [PubMed] [Google Scholar]
- 161.Narita Y, et al. Decellularized ureter for tissue-engineered small-caliber vascular graft. J Artif Organs. 2008;11(2):91–99. doi: 10.1007/s10047-008-0407-6. [DOI] [PubMed] [Google Scholar]
- 162.Sandusky GE, Lantz GC, Badylak SF. Healing comparison of small intestine submucosa and ePTFE grafts in the canine carotid artery. J Surg Res. 1995;58(4):415–420. doi: 10.1006/jsre.1995.1064. [DOI] [PubMed] [Google Scholar]
- 163.Badylak SF, et al. Comparison of the resistance to infection of intestinal submucosa arterial autografts versus polytetrafluoroethylene arterial prostheses in a dog model. J Vasc Surg. 1994;19(3):465–472. doi: 10.1016/s0741-5214(94)70073-7. [DOI] [PubMed] [Google Scholar]
- 164.Clarke DR, et al. Transformation of nonvascular acellular tissue matrices into durable vascular conduits. Ann Thorac Surg. 2001;71(5 Suppl):S433–S436. doi: 10.1016/s0003-4975(01)02556-5. [DOI] [PubMed] [Google Scholar]
- 165.Sharp MA, et al. A cautionary case: the SynerGraft vascular prosthesis. Eur J Vasc Endovasc Surg. 2004;27(1):42–44. doi: 10.1016/j.ejvs.2003.09.015. [DOI] [PubMed] [Google Scholar]
- 166.Das N, et al. Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas. Cardiovasc Intervent Radiol. 2011 doi: 10.1007/s00270-011-0096-z. [DOI] [PubMed] [Google Scholar]
- 167.Chemla ES, Morsy M , Randomized clinical trial comparing decellularized bovine ureter with expanded polytetrafluoroethylene for vascular access. Br J Surg. 2009;96(1):34–39. doi: 10.1002/bjs.6434. [DOI] [PubMed] [Google Scholar]
- 168.Spark JI, et al. Incomplete cellular depopulation may explain the high failure rate of bovine ureteric grafts. Br J Surg. 2008;95(5):582–585. doi: 10.1002/bjs.6052. [DOI] [PubMed] [Google Scholar]
- 169.McAllister TN, et al. Cell-based therapeutics from an economic perspective: primed for a commercial success or a research sinkhole? Regen Med. 2008;3(6):925–937. doi: 10.2217/17460751.3.6.925. [DOI] [PubMed] [Google Scholar]
- 170.Lee MH, et al. Considerations for tissue-engineered and regenerative medicine product development prior to clinical trials in the United States. Tissue Eng Part B Rev. 2010;16(1):41–54. doi: 10.1089/ten.TEB.2009.0449. [DOI] [PubMed] [Google Scholar]