Skip to main content
Antimicrobial Agents and Chemotherapy logoLink to Antimicrobial Agents and Chemotherapy
. 1978 Jan;13(1):61–69. doi: 10.1128/aac.13.1.61

Evaluation of the Micro-Media System for Quantitative Antimicrobial Drug Susceptibility Testing: a Collaborative Study

A L Barry 1, R N Jones 2, T L Gavan 3
PMCID: PMC352185  PMID: 626491

Abstract

Micro-Media Systems (MMS) has developed a procedure by which microdilution trays can be filled with dilutions of antimicrobial agents, frozen, and distributed to clinical laboratories. The trays are prepared in various distribution centers throughout the United States to supply clinical laboratories in the vicinity of each center. For use, trays are removed from the freezer, allowed to thaw, and then inoculated with inocula prepared as for any other susceptibility test, using a convenient disposable inoculator (ca. 5 μl per well). A collaborative study was planned to evaluate microdilution trays prepared in three Micro-Media Systems distribution centers. Microdilution minimal inhibitory concentrations (MICs) were compared to standard tube dilution tests (the international collaborative study group method). With gram-positive cocci, the two techniques gave essentially equivalent results. With gram-negative bacilli, the microdilution MICs were generally one doubling dilution lower than the standard tube dilution MICs. Similar results were seen with microdilution trays prepared with a Cooke Dynatech MIC 2000. Inter- and intralaboratory reproducibility with the macro- and microdilution techniques were quite satisfactory, i.e., at least 96% of the end points were within a range of ±1 log2 dilution intervals.

Full text

PDF
61

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Barry A. L., Effinger L. J., Badal R. E. Short-term storage of six penicillins and cephalothin in microdilution trays for antimicrobial susceptibility tests. Antimicrob Agents Chemother. 1976 Jul;10(1):83–88. doi: 10.1128/aac.10.1.83. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Barry A. L., Garcia F., Thrupp L. D. An improved single-disk method for testing the antibiotic susceptibility of rapidly-growing pathogens. Am J Clin Pathol. 1970 Feb;53(2):149–158. doi: 10.1093/ajcp/53.2.149. [DOI] [PubMed] [Google Scholar]
  3. Bennett J. V., Brodie J. L., Benner E. J., Kirby W. M. Simplified, accurate method for antibiotic assay of clinical specimens. Appl Microbiol. 1966 Mar;14(2):170–177. doi: 10.1128/am.14.2.170-177.1966. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Ericsson H. M., Sherris J. C. Antibiotic sensitivity testing. Report of an international collaborative study. Acta Pathol Microbiol Scand B Microbiol Immunol. 1971;217(Suppl):1+–1+. [PubMed] [Google Scholar]
  5. Gavan T. L., Town M. A. A microdilution method for antibiotic susceptibility testing: an evaluation. Am J Clin Pathol. 1970 Jun;53(6):880–885. doi: 10.1093/ajcp/53.6.880. [DOI] [PubMed] [Google Scholar]

Articles from Antimicrobial Agents and Chemotherapy are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES