Abstract
The goal of this study was to demonstrate high-resolution anatomical, BOLD (blood-oxygenation-level-dependent), and blood-flow (BF) MRI on large non-human primate (NHP) retinas using a 3-Tesla clinical scanner as a first step toward translation. Baboon was chosen because of its evolutionary similarity to human. Anesthetized preparation, free of eye-movement artifacts, was used to evaluate clinical scanner hardware feasibility. Anatomical MRI (0.1×0.2×2.0 mm) before contrast-agent injection detected three alternating bright-dark-bright layers. The hyperintense inner strip nearest to the vitreous was enhanced by an intravascular contrast agent, likely included the ganglion and bipolar cell layer and the embedded retinal vessels. The hypointense middle strip showed no contrast enhancement, likely included the avascular outer unclear layer and photoreceptor segments. The hyperintense outer strip showed contrast enhancement, likely corresponded to the choroid vascular layer. In the posterior retina, the total thickness including the choroid was 617±101µm (±SD, n=7). BOLD fMRI (0.3×0.6×2.0 mm) of oxygen inhalation relative to air increased 6.5±1.4%. Basal BF (2×2×2mm) was 83±30mL/100g/min (air), and hypercapnia increased BF by 25±9% (P<0.05). This study demonstrates multimodal MRI to image anatomy, physiology and function on large NHP retinas using a clinical scanner, offering encouraging data to explore human applications.
Keywords: High-resolution MRI, blood oxygenation level dependent (BOLD), blood flow, choroid, retinal diseases, high-resolution fMRI, hyperoxia, hypercapnia
INTRODUCTION
The retina is composed of three highly structured cell layers: the photoreceptor layer, bipolar/amacrine cell layer, and ganglion cell layer (1). The adjacent nuclear cell layers are connected by synapses. Two separate blood supplies – the retinal and choroidal vasculatures (2) – nourish the retina. The retinal vasculature exists primarily within the ganglion cell layer, but does project a deep planar capillary bed into the bipolar cell layer. The choroidal vasculature is located directly beneath the photoreceptor layer, sandwiched between the retinal pigment epithelium and the sclera. The photoreceptor layer is completely avascular. Choroid blood flow is many times higher than retinal blood flow and they are regulated differently in responses to stimulations (2). Some retinal diseases, such as diabetic retinopathy, glaucoma and macular degeneration, may have differential effects on different vascular and/or tissue layers in terms of anatomy, blood oxygenation and blood flow (BF), and their responses to stimulations (3,4). Thus, the ability to non-invasively image these clinically relevant parameters in vivo could have important applications.
Historically, the retina has been studied using optical imaging techniques. Fundus imaging, scanning laser ophthalmoscopy, and optical coherence tomography (5) are widely used to image retinal anatomy. Life-time phosphorescent imaging (6) and spectral reflectance (7) for detecting vascular oxygenation changes. Fluorescein angiography (8), indocyanin-green angiography (9), laser Doppler flowmetry (10) and laser speckle imaging (11) are used to measure relative BF or blood velocity. Optical imaging methods have high temporal and spatial resolution but require unobstructed light paths, are usually qualitative, and have small field of view. Eye diseases, such as senile cataract and vitreous hemorrhage, often preclude applications of optical retinal imaging techniques. With the exception of optical coherence tomography which is predominantly used for anatomical imaging to date, optical imaging techniques have ambiguous depth resolution.
By contrast, magnetic resonance imaging (MRI) provides non-invasive high-resolution anatomical, physiological and functional information without depth limitation, although the spatiotemporal resolution of MRI is lower compared to that of optics. Anatomical, blood-oxygenation-level-dependent (BOLD) and blood flow MRI has been widely used to image small brain substructures including columnar (12–14) and laminar (15,16) structures in the brains of humans and animal models. More recently, multimodal MRI has been applied to study the retinas of small anesthetized animals. These included anatomical layer resolution of the rat and cat retinas (17,18), relaxation and diffusion time constants of different layers of the rat and mouse retinas (18), BOLD fMRI of physiological (17) and visual (19) stimulations of the rat and cat retinas, and quantitative blood flow MRI by continuous arterial spin labeling (20). Multimodal MRI has also been applied to study retinal degeneration (17,20), diabetic retinopathy (21), and glaucoma (22,23) on rodent models.
Translation of retinal MRI applications from rodents to humans has two major challenges: i) hardware that limits spatial resolution and signal-to-noise ratio on clinical MRI scanners, and ii) eye movement in awake humans. As a first step toward translation, we investigated the feasibility of multimodal retinal MRI on anesthetized/paralyzed large non-human primate (baboon) using a standard clinical 3-Tesla MRI scanner. Baboon was chosen because the retina of baboon, compared to rodent, is evolutionarily closer to that of human, likely better recapitulates human retinal diseases. The size of baboon eye and the thickness of baboon retina are more similar to those of humans compared to rodents. Baboons have fovea in contrast to rodents and cats. Anesthesia and paralysis were used to exclude movement artifacts, such that we could focus on evaluating hardware feasibility, pulse sequence protocols and parameters for high-resolution multimodal MRI of the retinas on a clinical scanner. These multimodal MRI protocols included anatomical MRI, basal BF MRI, BOLD fMRI of hyperoxic challenge and BF fMRI of hypercapnic challenge. This study presents a novel approach to visualize anatomical, physiological (BOLD and BF) and functional MRI of large NHP retinas on a clinical scanner, and this serves as a first step toward translation. Comparisons with published rodent and cat data are made.
METHODS
Animal preparations
Seven normal baboons (Papio hamadryas Anubis, 14–18 kg) were studied with approval of the Institutional Animal Care and Use Committee and in accordance with the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research. In Group I, anatomical scans were performed on 4 baboons in 5 sessions with a total of 8 trials. In Group II, BOLD fMRI were performed on 3 baboons in 4 sessions with a total of 10 trials. In Group III, BF measurements were obtained from 3 baboons in 3 sessions with a total of 8 trials. Each session was performed on different day.
The baboon model, which offered high degree of stability, has been described previously (24). Briefly, anesthesia was initially inducted using ketamine (1.2 cc, i.m.), followed by oral intubation and cannulation of the right saphenous vein for fluid supplement and contrast agent administration. Animals were mechanically ventilated (Aestiva 5, Datex-Ohmeda, Madison, WI) at ~10 stroke/mins and 120–180 ml/stroke. Anesthesia was maintained using 0.8~1.0% isoflurane in air. The animal was positioned supine in a custom-made animal holder and stabilized with ear bars, mouth bar and padding around the head. Rectal temperature was maintained within normal physiological ranges (37–38° C) using a custom-built feedback-regulated circulating warm-air blanket. End-tidal CO2, O2 saturation, heart rate, and respiration rate were monitored continuously using an MRI compatible physiological monitoring equipment (Precess, InVivo, Orlando, FL), and were maintained within normal physiological ranges. Vecuronium was administered immediately before placing the animal inside the scanner and was maintained throughout the entire MRI study (0.1 mg/kg initial dose, followed by 10% of initial dose every 45 min). At the end of the MRI experiments, neostigmine (0.5–2 mg, i.v.) and atropine (0.6–1.2 mg, i.v.) were administered to reverse paralysis. All animals recovered from anesthesia and paralysis.
In Group I, to enhance the anatomical retinal vascular layers, Gd-DTPA (0.2–0.3 mmol/kg, Magnevist®, N = 2 of 5 baboons) was intravenously infused over a few mins and MRI measurements were made before and immediately after Gd-DTPA injection. In Group II, to modulate the BOLD MRI signals, subjects were ventilated with air (2 mins), oxygen (3 mins) and air (5 mins) during MRI acquisition. In Group III, to modulate the BF MRI signals, subjects were ventilated with air (3 min) and 5% CO2 in air (4 min) during MRI acquisition. A break of 5–10 min was given between trials. Multiple trials were repeated on each imaging session.
To verify that BF contrast signals are genuine, BF MRI was also measured on an additional animal (N = 1) alive and postmortem in the same setting. This animal was scheduled for necropsy due to unrelated clinical reasons and was euthanized in the scanner.
MRI
MRI studies were performed on a 3T Siemens TIM Trio (Siemens, Erlangen, Germany) using a body radiofrequency coil for transmission and a Siemens small receive-only surface coil (4 cm) for anatomical MRI and BOLD fMRI, and an 8-channel transmit/receive volume coil (human kneel coil, InVivo, Orlando, FL) for BF MRI and fMRI.
Anatomical MRI was acquired using fast low angle shot (FLASH) or balanced steady-state free precession (bSSFP) (25). The FLASH parameters were: repetition time (TR) = 50 ms, echo time (TE) = 3 ms, flip angle = 50°, a single slice thickness = 2 mm, readout bandwidth (BW) =16 kHz, field of view (FOV) = 29×29 mm, and matrix size = 290×145 (0.1×0.2×2.0 mm resolution). The higher in-plane resolution was placed perpendicular to the retina (anterior-posterior direction) to minimize partial-volume effect (PVE). Pre- and post-contrast enhanced images were acquired in time series for 15 mins each. The bSSFP parameters were: TR = 12 ms, TE = 3 ms, flip angle = 40°, slice thickness = 2 mm, readout BW = 21 kHz, FOV = 50×50 mm, and matrix size = 500×250 (0.1×0.2×2.0 mm resolution). Pre- and post-contrast enhanced images were acquired in time series for 6 mins each.
BOLD MRI was acquired using a BOLD-sensitive pass-band bSSFP technique (26). The imaging parameters were: TR = 8 ms, TE = 4 ms, flip angle = 40°, a single slice thickness = 2 mm, readout BW = 36 kHz, FOV = 50×50 mm, and matrix = 150×75 (0.3×0.6×2.0 mm resolution). A non-slice selective inversion recovery pulse was employed to suppress vitreous signal (inversion delay = 1800 ms). The temporal resolution per image was 4 s. Each stimulus trial took 10 mins.
BF MRI was acquired using the pseudo-continuous arterial spin labeling (pCASL) technique with a single-shot gradient echo-planar imaging. The imaging parameters were: TR = 3500 ms, TE = 16 ms, labeling duration = 2.1 sec, labeling gradient of 0.6 G/cm, post-labeling delay = 700 ms, labeling offset = 60 mm, matrix = 64×64, FOV = 128×128 mm, and 12 contiguous slices with 2 mm slice thickness (2×2×2 mm resolution). Two of the eight trials were acquired with 4 mm slice thickness. Each stimulus trial took 7 mins. Specific absorption rate was not an issue for the pCASL protocol as the protocol was essentially identical to typical human brain pCASL BF measurements and was verified by the scanner safety monitor.
Data analysis
Image analysis was performed using Matlab (MathWorks Inc, Natick, MA) and FSL (FMRIB's Software Library, Oxford, UK). All images were acquired in time series and co-registered using custom-written algorithm in Matlab. The retina was automatically detected using an edge-detection technique as previously described (17). Radial projections perpendicular to the vitreous boundary were obtained with three or four times the sampling density of the original image, and projection profiles at different time points were then co-registered to the averaged profile by minimizing the root-mean-square distances. Time-series movies of MR images were carefully evaluated to verify the absence of gross motion or drift before further analysis.
To quantitatively determine laminar thickness, the edge-detection technique described above was employed and the projection profiles were averaged along the length of the retina. Band thicknesses were determined from the averaged projection profile using the “half height” method as commonly used to measure vessel diameters in optical imaging studies.
BOLD fMRI activation maps were generated using FSL. A cross correlation analysis was performed by matching the fMRI signal time courses to the stimulus paradigm with a background signal intensity threshold applied prior to fMRI analysis to exclude low intensity pixels (such as noisy background and the suppressed vitreous). A cluster analysis with cluster size P <0.05 was further imposed to threshold the cross correlation map. Time courses had band-pass temporal smoothing (range of 0.002~0.1Hz). Quantitative analysis of fMRI percent changes utilized a region of interest (ROI) analysis to avoid correlation bias. Percent changes were tabulated for 90% of maximal signal changes. Regional variations of the fMRI responses along the length of the retina were also evaluated.
BF in ml/100g/min was calculated pixel-by-pixel using (24), , where α is the labeling efficiency, λ is the water brain-blood partition coefficient, T1a is the longitudinal relaxation time of arterial blood, w is the post-labeling delay and τ is the labeling duration. λ of 0.9, α of 0.8, τ of 2.1 sec, and T1a of 1.66 s at 3 T were used. BF changes due to hypercapnia in the retina were also analyzed as described above for the BOLD data. For comparison, basal BF and hypercapnia-induced BF changes for gray matter and white matter from the brain were also tabulated. Gray matter and white matter of the brain were segmented based on T1-weighted anatomical MRI as described previously (24).
All statistical tests employed t-test unless otherwise specified. P < 0.05 was taken to be statistically significant.
Histology
Four eyes from two additional female baboons (both 19 years old, 14 and 18.5 kg) were enucleated and immersion fixed in 10% neutral buffered formalin immediately after post-mortem. These eyes were obtained from necropsy, different from those of the survival MRI studies. Eyes were paraffin embedded and sectioned at 12 µm and stained with H&E. Each histological section was digitally photographed within 2–5 days postmortem and laminar thicknesses were measured at 100X.
RESULTS
Anatomical MRI
The diameter of the baboon eye was 21.8 ± 0.4 mm (mean ± SD, 4 baboons) in the anterior-posterior direction as measured by MRI. Assuming a sphere, PVE due to the curvature of the retina was 15.2% of the total retinal thickness for a central imaging slice of 2 mm. Because the retina is relatively flat at the posterior pole where the fovea and optic nerve head are located, this estimate likely reflected the upper limit. Figure 1A shows a representative T1-weighted gradient-echo (FLASH) image of a normal retina revealed three distinct “layers” as indicated by the alternating bright, dark and bright bands. The adjacent vitreous and sclera appeared relatively hypointense because of the long T1 of the vitreous, and the short T2* of the sclera. The optic nerve, rectus muscles, lens, anterior chambers, iris, ciliary bodies, among others, were also clearly delineated. Administration of the intravenous contrast agent Gd-DTPA markedly enhanced the inner and outer bands, but not in the middle bands, lens or vitreous. In addition, the outer band was more enhanced than the inner band (Figure 1B). The subtraction of pre- from post-contrast images demonstrated the localization of Gd-DTPA impermeable vasculature on either side of the retina (Figure 1C).
To improve temporal resolution and to corroborate laminar resolution, we explored bSSFP acquisition. Figure 2 shows the bSSFP images before and after Gd-DTPA administration. Similar alternating bright, dark and bright bands were observed before Gd-DTPA. The two bounding layers were enhanced after Gd-DTPA. The total scan time was 6 mins compared to the 15-min FLASH acquisition. Signal-to-noise ratio was apparently improved as well, although vigorous comparison was not performed.
Retinal thickness was calculated using edge-detection technique. The group-averaged total retinal thicknesses are plotted along the length of the retina (Figure 3A). The retina is thickest around the fovea and the optic nerve head, and the thickness tapered off toward the distal edges of the retina. The thicknesses for the three “layers” were analyzed for an ROI including the fovea as shown in the inset of Figure 3B. The group-averaged thicknesses were 218 ± 42, 182 ± 40, and 217 ± 59 µm by MRI (mean ± SD, N = 8 trials), for the inner, middle and outer MRI “layers”, respectively. The total retinal thickness including the choroid was 617 ± 101 µm from the same ROI. The group-averaged inner-to-outer peak spacing was 375 ± 91 µm.
A histological section depicting different cell layers and a distinct choroidal vascular layer is shown in Figure 4. The nerve fiber layer (NFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), inner segment (IS) and outer segment (OS) and the choroid (CH) were clearly identified. Comparative analysis between MRI and histology yielded the following layer assignments. Gd-DTPA enhanced the inner band of MRI, which was assigned to include the ganglion cell layer and inner nuclear layer with embedded retinal vasculature. The middle band, which appeared relatively hypointense on anatomical imaging, was not enhanced by Gd-DTPA and was thus assigned the avascular outer nuclear layer and the photoreceptor segments. Gd-DTPA enhanced the outer band, which was assigned the choroid. The corresponding histological inner, middle and outer band thicknesses for the MRI bands were, respectively, 122 ± 7 (NFL, GCL, IPL, OPL), 113 ± 8 (ONL, IS, OS), and 91 ± 3 µm (choroid), with a total thickness of 326 ± 10 µm (mean ± SD, N = 4 eyes), including the choroid.
BOLD MRI
Dynamic BOLD fMRI was used to probe the responses to oxygen inhalation relative to air (Figure 5). BOLD fMRI responses were detected to be highly localized to the retina. The group-averaged time course from the posterior retina ROI showed increased BOLD signals during oxygen inhalation compared to air, with a mean BOLD increase of 6.5 ± 1.4% (mean ± SD, N = 10 trials). BOLD responses were also detected globally in the rectus muscles and ciliary bodies but were largely absent from the vitreous and lens as expected. The group-averaged BOLD percent changes are plotted along the length of the retina in Figure 6. BOLD percent changes showed spatial dependence, with the responses being significantly stronger around the fovea and the optic nerve head than the distal edges of the retina (P < 0.05 by Tukey Honestly Significant Difference).
BF MRI
Figure 7A shows the BF images obtained using BF MRI from one representative animal. BF contrast was reliably detected. The highest BF was at the posterior pole and dropped off distally. To verify BF contrast signals are genuine, BF was also measured in alive and post-mortem animal (N = 1) in the same setting where the animal was euthanized in the magnet for unrelated clinical reasons. The results showed no significant BF contrasts in the postmortem retina and brain (data not shown), indicating no significant unwanted magnetization-transfer effect.
Group-averaged basal blood flow and hypercapnia-induced blood-flow changes of the retina, white and gray matter of the brain were analyzed from the same animals (Figure 7B). Basal BF from the posterior retina ROI was 83 ± 30 mL/100g/min (mean ± SD, N = 8 trials). Hypercapnia increased BF by 25 ± 9% in the retina. By comparison, basal BF values of the gray and white matter were 60 ± 12 and 24 ± 3 mL/100g/min, respectively. Hypercapnia increased BF by 74 ± 13% and 85 ± 23% in the gray and white matter, respectively. The basal BF of the retina and gray matter were significantly higher than that of the white matter (P < 0.01), but no significant difference was found between the retina and the gray matter (P > 0.05). Hypercapnic-induced % BF changes were higher in the brain than in the retina (P < 0.01).
DISCUSSION
This study demonstrates hardware feasibility of high-resolution multimodal MRI of the retinas of large NHPs using a clinical 3T scanner. Anatomical MRI reveals multiple tissue and vascular “layers” in the retina. Gd-DTPA enhanced MRI corroborates layer assignments. Basal BF, hyperoxia-induced BOLD changes, and hypercapnia-induced BF changes in the retina are reliably detected. While spatial resolution needs improvement and will be the target of future investigations, this report provides encouraging data to explore retinal MRI in large NHPs and human.
The advantages of MRI include depth resolution, images unhindered by media opacity, and a large field of view, while the disadvantages of MRI include poorer spatiotemporal resolution and high cost, compared to optical imaging techniques. MRI could provide valuable, clinically relevant anatomical, physiological and functional data which may be helpful for early detection and staging of retinal diseases, as well demonstrated in many neurological disorders. This approach also has the potential to complement existing retinal imaging techniques.
Potential issues
High-resolution MRI of the NHP retina may be susceptible to hardware and eye drift artifacts because high-resolution imaging pulse sequences are more demanding on the magnetic field gradient, which can lead to temperature-induced frequency and signal drift. We confirmed on phantoms that our imaging protocols with identical parameters did not have significant hardware-related drift over half an hour of data acquisition (data not shown). The eye could drift significantly despite the animal being under anesthesia (27). To ensure the absence of movement artifacts and drifts, time-loop movies of the raw data and center-of-mass time courses were evaluated. Signal time courses were also evaluated to ensure no sudden jumps or significant drift. These precautions were necessary because signal contamination from either side of the retina due to mis-registration would markedly affect signal intensities.
Partial-volume effect due to the thin retina could be significant because the thin retina is bounded by the vitreous and the sclera, which have very different signal intensities from that of the retina. Although vitreous signals were suppressed using short TR in anatomical MRI and inversion pulse in BOLD MRI, PVE could affect retinal thickness, basal BF, BOLD and BF percent change measurements. Future studies will need to improve spatial resolution and sensitivity to improve laminar thickness quantification, and to differentiate BOLD and BF MRI signal changes between the retinal and choroidal vasculatures.
Absolute quantification of BF is generally difficult. The pCASL MRI technique to measure BF of the retina has the following limitations. BF calculation used the blood-tissue partition coefficient (λ) of the brain (28) because blood-tissue partition coefficient in the retina has not been measured. This assumption is reasonable because the retina is part of the central nervous system. In addition, brain T1 was used in the BF calculation. Retina T1 has been reported to be similar to brain T1 in animals (29). BF MRI of the brain has been cross-validated with PET and autoradiographic techniques. Ultimately, ASL MRI of the retina needs to be cross validated with microsphere or iodoantipyrine technique in animal models. Improving accuracy of quantitative BF MRI remains an active area of research.
Anatomical MRI
Three distinct “layers” of alternating bright, dark and bright bands were resolved. The vitreous and the sclera appeared relatively hypointense because of the long T1 of the vitreous water, and the low water content and short T2* of the sclera. The vitreous and sclera set the boundaries of the retina. The retinal vessels consist of non-fenestrated capillaries, forming the blood-retinal barriers, which are impervious to many tracers, including Gd-DTPA. In the choroidal circulation, tight-junctions between retinal epithelial cells prevent passages of large molecules (including Gd-DTPA) from the choriocapillaris (30). Thus, Gd-DTPA selectively enhances signal in the blood vessels, providing valuable contrast. Indeed, subtraction of post- and pre-contrast images from the Gd-DTPA experiments showed marked signal enhancement on either side of the retina, with the outer band being more enhanced than the inner band. The contrast-enhanced imaging results indicated that: i) There are two vascular layers located at either end of the retina with the middle of the retina being avascular, as expected (31). ii) The choroidal vasculature has markedly higher blood flow and blood volume than the retinal vasculature, consistent with established differences in blood flow between the two vasculatures (2). The Gd-DTPA enhancement and laminar assignments herein are in good agreement with previous MRI studies in rats (17) and cats (18).
MRI-derived total retinal thickness including the choroid was 617 ± 101 µm at the posterior retina which was thicker than that by histology of 326 ± 10 µm (P < 0.05). If PVE of 15% due to curvature was applied (17), the MRI-derived total retinal thickness including the choroid would be 537 µm, which was still significantly thicker than by histology. Discrepancy between MRI and histological thicknesses could arise from collapse of choroidal vessels after removal of orbits from the systemic circulation, histological shrinkage, differences in retinal regions analyzed, different animals being used for MRI and histology, and/or PVE due to MRI spatial resolution. To our knowledge, there are no published baboon retinal thicknesses with which to compare. By comparison with the rat retina, the inner, middle and outer band thicknesses of adult Sprague-Dawley rat retinas were, respectively, 101 ± 17, 79 ± 11, and 86 ± 10 µm by MRI (n = 24, total thickness 267 ± 31 µm), which were also thicker than those by histology, namely, 92 ± 9, 77 ± 9 and 37 ± 8 µm (SD, n = 9, total thickness = 205 ± 11 µm) (17). By appearance of histology, the baboon retina is substantially different from rat retina (32). For example, baboon NFL and OPL are comparatively thicker, whereas IPL and ONL are comparatively thinner, relative to the overall thicknesses.
There was a strong spatial dependence in the total thickness of retina/choroid complex along the length of the retina (Figure 3A). The retina/choroid complex was thicker immediate adjacent to the ONH, on the side of the fovea based on optical coherence tomography data (33). In around the expected region of the fovea, the retina/choroid was thinner slightly compared to its surrounding regions on either side, likely because the retinal thickness reach a minimum at the fovea (34). The total thickness dropped off markedly away from the macular area as expected (33,35).
BOLD MRI
Oxygen inhalation relative to air is expected to increase arteriole, capillary and venous oxygen saturation and thus is expected to increase BOLD signal, as well demonstrated in the brain (36). Oxygen inhalation has been reported to increase BOLD signals in the gray matter of the rhesus monkey brain by 2.4% at 3T (37). Because choroidal BF is much higher than retinal BF, the observed BOLD signal is likely predominantly from choroidal vasculature. The arteriovenous oxygen difference in the choroid (2) is small compared to that of the brain. Thus, one might expect a small hyperoxia-induced BOLD increase. In contrast, the group-averaged BOLD increase in the retina/choroid complex during oxygen challenge was 6.5 ± 1.4%, generally larger than those of the brain. This is likely because the choroid has a high vascular density, and thus the larger percent changes. In addition, it is worth pointing out that hyperoxia markedly decreases retinal blood flow (by 60% relative to air inhalation) (39), but has no effect on choroidal vessels (38). By comparison, hyperoxia decreases brain blood flow by ~10% (40). Such vasoconstriction would tend to counteract the BOLD signal increase from elevated oxygen tension by hyperoxia per se. The net effect observed in our study is a positive BOLD increase, suggesting that the increased oxygen delivery per se from oxygen inhalation dominates. The results herein are in good agreement with previous BOLD fMRI study of oxygen challenge in the rat retina, which also detected positive BOLD signal changes (17). Further exploration of laminar-specific BOLD and blood-flow measurements would help to detect these unique vascular responses in the retina.
There was a strong spatial dependence in the BOLD responses along the length of the baboon retina (Figure 6). The responses were the strongest around the fovea and the optic nerve head, and dropped off distally. This appeared consistent with similar profile in layer thickness (Figure 3A) and BF values (Figure 7).
Blood flow
Under normal physiological conditions, BF is intricately coupled to basal metabolism and function, as well demonstrated in the brain. Basal BF of the total retina, including the choroid was 83 ± 30 mL/100g/min in anesthetized baboon. Basal BF of the rat retina has been reported to be 630 ± 100 mL/100g/min under 1% isoflurane also using ASL MRI (20).
The anesthetized baboon brain gray-matter BF was 60 ± 12 mL/100g/min obtained in the same animals, consistent with previous brain BF data in baboon (24). By comparison, BF of the entire rat brain was ~100 ml/100g/min under similar experimental conditions (41,42). The BF retina:brain ratio was 6.3:1 in rat and 1.3:1 in baboon. This difference could be due to differences in partial volume effect and/or species.
Hypercapnic inhalation is expected to increase BF, as well demonstrated in the brain (36). In the baboon brain, BF in the gray matter increased 74 ± 13%. In the rat brain, hypercapnic (5% CO2 in air) inhalation increased cerebral BF varied over a wide range, but has been reported to increase ~50% (42) in anesthetized rats. Similar hypercapnia-induced changes in cerebral BF in humans under different anesthetics have also been reported in the literatures. Hypercapnia-induced BF increase in the baboon retina (25 ± 9%) appears to be smaller than in the brain, consistent with 16 ± 6% increase in rat retina (43). The high basal choroidal BF could reduce head room for additional vasodilation (42).
Species differences
Retinal thickness, blood flow value, and fMRI percent changes of baboon retinas differed from rat (17) and cat (18) data. Retinal thickness was about double that of rat and cat total retinal thickness. The baboon retina showed heterogeneity, revealing indentation of the fovea and optic nerve head (Figure 3A), in contrast to rat data which was relatively uniform by MRI (17). Retinal thickness in baboon showed a rapid drop off as a function of distance away from the optic nerve head, in contrast to rat data which was relatively uniform (17). There were also the marked differences in histological appearances. For example, with respect to the overall thicknesses, the baboon NFL and OPL are thicker whereas IPL and ONL are thinner compared to the rat retina. Baboon, in contrast to cat, does not have a tapetum (18). Baboon has a fovea, whereas neither rat nor cat has a fovea.
BF of the baboon retina were also lower than that in rat retina, consistent with baboon brain BF also being lower than rat brain BF. Larger animals generally have lower basal BF (which reflects lower basal metabolic rate) than smaller animals. Moreover, BF of the retina in baboon showed a rapid drop off as a function of distance from the optic nerve head, in contrast to rat BF data which appeared more uniform (43). Cognizant of more partial-volume effect in the baboon retinal data, these comparisons suggest there are species differences and warrant further investigations.
CONCLUSION
This study reports a proof-of-concept that anatomical MRI, hyperoxia-induced BOLD fMRI changes, quantitative basal blood flow and hypercapnia-induced blood-flow fMRI in the retina of anesthetized baboon can be imaged using a clinical 3-Tesla scanner. Comparison with rodent and cat data revealed some species differences in retina thickness, blood flow value, and fMRI responses. These findings offer encouraging data to explore human applications. Indeed, retinal MRI in humans has recently been reported (44–46). Translating high-resolution anatomical, physiological (BF and oxygenation tension) and functional MRI to image the unanesthetized human retina could have important applications. Irrespective of whether these approaches can be translated to humans or clinics, this approach can be utilized to study retinal diseases and to test novel therapeutic strategies in the retinas of large non-human primates, which likely better model human retinal diseases compared to rodents.
Acknowledgments
Grant support: This work was supported in part by the NIH/NEI (R01 EY014211 and EY018855), and MERIT from the Department of Veterans Affairs, as well as by a Translational Technology Research Grant via the Clinical Translational Science Award (CTSA, parent grant UL1RR025767) and American Heart Association’s Established Investigator Award (EIA 0940104N) to TQD.
REFERECES
- 1.Wassle H, Boycott BB. Functional architecture of the mammalian retina. Physiol Rev. 1991;1:447–480. doi: 10.1152/physrev.1991.71.2.447. [DOI] [PubMed] [Google Scholar]
- 2.Bill A. Circulation in the eye. In: Renkin EM, Michel CC, editors. Handbook of Physiology: Cardiovascular. Bethesda, MD: American Physiological Society; 1984. [Google Scholar]
- 3.Pemp B, Schmetterer L. Ocular blood flow in diabetes and age-related macular degeneration. Can J Ophthalmol. 2008;43(3):295–301. doi: 10.3129/i08-049. [DOI] [PubMed] [Google Scholar]
- 4.Pournaras CJ, Rungger-Brandle E, Riva CE, Hardarson SH, Stefansson E. Regulation of retinal blood flow in health and disease. Prog Retin Eye Res. 2008;27(3):284–330. doi: 10.1016/j.preteyeres.2008.02.002. [DOI] [PubMed] [Google Scholar]
- 5.Fujimoto JG, Brezinski ME, Tearney GJ, Boppart SA, Bouma B, Hee MR, Southern JF, Swanson EA. Optical biopsy and imaging using optical coherence tomography. Nat Med. 1995;1:970–972. doi: 10.1038/nm0995-970. [DOI] [PubMed] [Google Scholar]
- 6.Shonat RD, Richmond KN, Johnson PC. Phosphorescence quenching and the microcirculation: An automated, multipoint oxygen tension measuring instrument. Rev Sci Instrum. 1995;66:5075–5084. [Google Scholar]
- 7.Grinvald A, Bonhoeffer T, Vanzetta I, Pollack A, Aloni E, Ofri R, Nelson D. High-resolution functional optical imaging: from the neocortex to the eye. Ophthalmol Clin North Am. 2004;17:53–67. doi: 10.1016/j.ohc.2003.12.003. [DOI] [PubMed] [Google Scholar]
- 8.Preussner PR, Richard G, Darrelmann O, Weber J, Kreissig I. Quantitative measurement of retinal blood flow in human beings by application of digital image-processing methods to television fluorescein angiograms. Graefes Arch Clin Exp Ophthalmol. 1983;221:110–112. doi: 10.1007/BF02133848. [DOI] [PubMed] [Google Scholar]
- 9.Guyer DR, Yannuzzi LA, Slakter JS, Sorenson JA, Orlock S. The status of indocyanine-green videoangiography. Cur Opin Ophthalmol. 1993;4:3–6. doi: 10.1097/00055735-199306000-00002. [DOI] [PubMed] [Google Scholar]
- 10.Formaz F, Riva CE, Geiser M. Diffuse luminance flicker increases retinal vessel diameter in human. Curr Eye Res. 1997;16:1252–1257. doi: 10.1076/ceyr.16.12.1252.5021. [DOI] [PubMed] [Google Scholar]
- 11.Cheng H, Duong TQ. Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging. Opt Lett. 2007;32:2188–2190. doi: 10.1364/ol.32.002188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Kim D-S, Duong TQ, Kim S-G. High-resolution mapping of iso-orientation columns by fMRI. Nature Neurosci. 2000;3:164–169. doi: 10.1038/72109. [DOI] [PubMed] [Google Scholar]
- 13.Duong TQ, Kim D-S, Ugurbil K, Kim S-G. Localized blood flow response at sub-millimeter columnar resolution. Proc Natl Acad Sci USA. 2001;98:10904–10909. doi: 10.1073/pnas.191101098. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Cheng K, Waggoner RA, Tanaka K. Human ocular dominance columns as revealed by high-field functional magnetic resonance imaging. Neuron. 2001;32:359–397. doi: 10.1016/s0896-6273(01)00477-9. [DOI] [PubMed] [Google Scholar]
- 15.Silva AC, Koretsky AP. Laminar specificity of functional MRI onset times during somatosensory stimulation in rat. Proc Natl Acad Sci USA. 2002;99:15182–15187. doi: 10.1073/pnas.222561899. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Goense JB, Logothetis NK. Laminar specificity in monkey V1 using high-resolution SE-fMRI. Magn Reson Imag. 2006;24:381–392. doi: 10.1016/j.mri.2005.12.032. [DOI] [PubMed] [Google Scholar]
- 17.Cheng H, Nair G, Walker TA, Kim MK, Pardue MT, Thule PM, Olson DE, Duong TQ. Structural and functional MRI reveals multiple retinal layers. Proc Natl Acad Sci USA. 2006;103:17525–17530. doi: 10.1073/pnas.0605790103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Shen Q, Cheng H, Pardue MT, Chang TF, Nair G, Vo VT, Shonat RD, Duong TQ. Magnetic resonance imaging of tissue and vascular layers in the cat retina. J Magn Reson Imaging. 2006;23(4):465–472. doi: 10.1002/jmri.20549. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Duong TQ, Ngan S-C, Ugurbil K, Kim S-G. Functional Magnetic Resonance Imaging of the Retina. Invest Ophthalmol Vis Sci. 2002;43:1176–1181. [PMC free article] [PubMed] [Google Scholar]
- 20.Li Y, Cheng H, Shen Q, Kim M, Thule PM, Olson DE, Pardue MT, Duong TQ. Blood-Flow Magnetic Resonance Imaging of Retinal Degeneration. Invest Ophthalmol Vis Sci. 2009;50:1824–1830. doi: 10.1167/iovs.08-2188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Berkowitz BA, Roberts R, Luan H, Peysakhov J, Mao X, Thomas KA. Dynamic contrast-enhanced MRI measurements of passive permeability through blood retinal barrier in diabetic rats. Invest Ophthalmol Vis Sci. 2004;45(7):2391–2398. doi: 10.1167/iovs.03-1381. [DOI] [PubMed] [Google Scholar]
- 22.Calkins DJ, Horner PJ, Roberts R, Gradianu M, Berkowitz BA. Manganese-enhanced MRI of the DBA/2J mouse model of hereditary glaucoma. Invest Ophthalmol Vis Sci. 2008;49(11):5083–5088. doi: 10.1167/iovs.08-2205. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Chan KC, Fu QL, Hui ES, So KF, Wu EX. Evaluation of the retina and optic nerve in a rat model of chronic glaucoma using in vivo manganese-enhanced magnetic resonance imaging. Neuroimage. 2008;40(3):1166–1174. doi: 10.1016/j.neuroimage.2008.01.002. [DOI] [PubMed] [Google Scholar]
- 24.Wey HY, Wang DJ, Duong TQ. Baseline CBF, and BOLD, CBF, and CMRO2 fMRI of visual and vibrotactile stimulations in baboons. J Cereb Blood Flow Metab. 2010 doi: 10.1038/jcbfm.2010.154. in press. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Scheffler K, Lehnhardt S. Principles and applications of balanced SSFP techniques. Eur Radiology. 2003;13:2409–2418. doi: 10.1007/s00330-003-1957-x. [DOI] [PubMed] [Google Scholar]
- 26.Miller KL, Smith SM, Jezzard P, Wiggins GC, Wiggins CJ. Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths. Neuroimage. 2007;37(4):1227–1236. doi: 10.1016/j.neuroimage.2007.06.024. [DOI] [PubMed] [Google Scholar]
- 27.Duong TQ, Muir ER. Magnetic resonance imaging of the retina. Jpn J Ophthalmol. 2009;53(4):352–367. doi: 10.1007/s10384-009-0688-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Herscovitch P, Raichle ME. What is the correct value for the brain-blood partition coefficient for water? J Cereb Blood Flow Metab. 1985;5:65–69. doi: 10.1038/jcbfm.1985.9. [DOI] [PubMed] [Google Scholar]
- 29.Nair G, Shen Q, Duong TQ. Relaxation Time Constants and Apparent Diffusion Coefficients of Rat Retina at 7 Tesla. Int J Imag Syst Tech. 2010;20:126–130. [Google Scholar]
- 30.Vinores SA. Assessment of blood-retinal barrier integrity. Histol Histopathol. 1995;10:141–154. [PubMed] [Google Scholar]
- 31.Harris A, Kagemann L, Cioffi GA. Assessment of human ocular hemodynamics. Survey of Ophthalmol. 1998;42:509–533. doi: 10.1016/s0039-6257(98)00011-3. [DOI] [PubMed] [Google Scholar]
- 32.Duong TQ, Pardue MT, Thule PM, Olson DE, Cheng H, Nair G, Li Y, Kim M, Zhang X, Shen Q. Layer-specific anatomical, physiological and functional MRI of the retina. NMR Biomed. 2008;21:978–996. doi: 10.1002/nbm.1311. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Cheng S, Lam C, Yap M. Retinal thickness in myopic and non myopic eyes. Ophthalmic Physiol Opt. 2010;30(6):776–784. doi: 10.1111/j.1475-1313.2010.00788.x. [DOI] [PubMed] [Google Scholar]
- 34.Sanchez-Tocino H, Alvarez-Vidal A, Maldonado M, Moreno-Montanes J, Garcia-Layana A. Retinal thickness study with optical coherence tomography in patients with diabetes. Invest Ophthalmol Vis Sci. 2002;43(5):1588. [PubMed] [Google Scholar]
- 35.Manjunath V, Taha M, Fujimoto JG, Duker JS. Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography. Am J Ophthalmol. 2010;150(3):325–329. doi: 10.1016/j.ajo.2010.04.018. e321. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Raichle ME. Circulatory and metabolic correlates of brain function in normal humans. In: Plum F, editor. Handbook of Physiology-The Nervous System V: Higher Functions of the Brain. Bethesda: American Physiological Society; 1987. pp. 643–674. [Google Scholar]
- 37.Zhang X, Nagaoka T, Auerbach EJ, Champion R, Zhou L, Hu X, Duong TQ. Quantitative basal CBF and CBF fMRI of rhesus monkeys using three-coil continuous arterial spin labeling. Neuroimage. 2007;34(3):1074–1083. doi: 10.1016/j.neuroimage.2006.10.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Geiser MH, Riva CE, GDorner GT, Diermann U, Luksch A, Schmetterer L. Response of choroidal blood flow in the foveal region to peroxia and hyperoxia-hypercapnia. Current Eye Res. 2000;21:669–676. [PubMed] [Google Scholar]
- 39.Riva CE, Grunwald JE, Singclair SH. Laser Doppler velocimetry study of the effect of pure oxygen breathing on retinal blood flow. Invest Ophthalmol Vis Sci. 1983;24:47–51. [PubMed] [Google Scholar]
- 40.Kety SS, Schmidt CF. The effects of altered arterial tensions of carbon dioxide and oxygen on cerebral blood flow and cerebral oxygen consumption of normal young men. J Clin Invest. 1948;27:484–491. doi: 10.1172/JCI101995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Sicard K, Shen Q, Brevard ME, Sullivan R, Ferris CF, King JA, Duong TQ. Regional cerebral blood flow and BOLD responses in conscious and anesthetized rats under basal and hypercapnic conditions: implications for functional MRI studies. J Cereb Blood Flow Metab. 2003;23(4):472–481. doi: 10.1097/01.WCB.0000054755.93668.20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Sicard KM, Duong TQ. Effects of Hypoxia, Hyperoxia and Hypercapnia on Baseline and Stimulus-Evoked BOLD, CBF and CMRO2 in Spontaneously Breathing Animals. Neuroimage. 2005;25:850–858. doi: 10.1016/j.neuroimage.2004.12.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Li Y, Cheng H, Duong TQ. Blood-flow magnetic resonance imaging of the retina. Neuroimage. 2008;39:1744–1751. doi: 10.1016/j.neuroimage.2007.10.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Zhang Y, Peng Q, Kiel JW, Rosende CA, Duong TQ. Magnetic resonance imaging of vascular oxygenation changes during hyperoxia and carbogen challenges in the human retina. [online Sept 16 2010];Invest Ophthalmol Vis Sci. 2010 doi: 10.1167/iovs.10-6108. in press. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Peng Q, Zhang Y, Oscar San Emeterio Nateras O, van Osch MJP, Duong TQ. Magnetic Resonance Imaging of Blood Flow of the Human Retina. Magn Reson Med. 2010 doi: 10.1002/mrm.22763. in press. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Maleki N, Dai W, Alsop DC. Blood flow quantification of the human retina with MRI. NMR Biomed. 2010 doi: 10.1002/nbm.1564. in press. [DOI] [PubMed] [Google Scholar]