Abstract
Objective
To test whether naltrexone, an opioid receptor antagonist, affects the minimum alveolar concentration (MAC) of isoflurane in cats, a species that is relatively resistant to the general anesthetic sparing effects of most opioids.
Study design
Randomized, crossover, placebo-controlled, blinded experimental design.
Animals
Six healthy adult cats weighing 4.9 ± 0.7 kg.
Methods
The cats were studied twice. In the first study, baseline isoflurane MAC was measured in duplicate. The drug (saline control or 0.6 mg kg−1 naltrexone) was administered IV every 40–60 minutes, and isoflurane MAC was re-measured. In the second study, cats received the second drug treatment using identical methods two weeks later.
Results
Isoflurane MAC was 2.03 ± 0.12% and was unchanged from baseline following saline or naltrexone administration.
Conclusion and clinical relevance
MAC was unaffected by naltrexone. Because MAC in cats is unaffected by at least some mu-opioid agonists and antagonists, spinal neurons that are directly modulated by mu-opioid receptors in this species cannot be the neuroanatomic sites responsible for immobility from inhaled anesthetics.
Keywords: Naltrexone, Cats, Minimum alveolar concentration, Isoflurane
Introduction
Inhaled anesthetics act within the spinal cord to prevent movement during surgery, although the specific neurons and receptors responsible for this effect are unknown at present (Sonner et al. 2003). The immobilizing potency for inhaled anesthetics is commonly described in terms of the minimum alveolar concentration or MAC (Eger et al. 1965), which is equivalent to the mean effective concentration (EC50) required to prevent movement in response to a noxious stimulus.
Opioids dose-dependently decrease MAC in many species. For example, remifentanil, a mu-opioid receptor agonist, decreases halothane MAC by up to 65% in rats (Criado & Gomez e Segura 2003) and enflurane MAC by up to 71% in dogs (Michelsen et al. 1996). Nevertheless, opioid receptors are not regarded as relevant to the mechanism of inhaled anesthetic immobility since opioid receptor antagonists do not increase MAC in either rats (Harper et al. 1978) or dogs (Pace & Wong 1979).
Anesthetic effects of opioids are very different in cats than in rats or dogs. Some mu- and kappa-opioid receptor agonists cause modest or minimal reductions in isoflurane requirement in cats (Ilkiw et al. 2002). Furthermore, remifentanil in cats does not affect isoflurane MAC at all (Brosnan et al. 2009), despite an ability for selective mu-receptor agonists to modulate motor function within the cat spinal cord (Steffens & Schomburg 2011).
Since MAC-sparing effects of opioid agonists are different in cats compared to rats or dogs, the effects of opioid antagonists might likewise differ. The purpose of this study was to test whether high doses of the opioid receptor antagonist naltrexone could increase isoflurane MAC in cats.
Materials and Methods
Six healthy adult cats weighing 4.9 ± 0.7 kg (mean ± SD) were studied using a blinded, randomized, placebo-controlled, crossover design that was approved by the Animal Use and Care Committee at the University of California, Davis. Each cat was anesthetized twice, two weeks apart. Food, but not water, was withheld overnight prior to study.
Anesthesia was induced in unsedated cats using isoflurane in oxygen administered in an acrylic chamber. Cats were tracheally intubated with a cuffed 4.5 mm endotracheal tube and anesthesia was maintained using isoflurane in oxygen delivered via a coaxial Mapleson F circuit. Breathing was controlled using a pressure-cycled, flow-controlled ventilator (Mark 7, Bird Corporation, CA USA) to achieve a 10 cmH2O peak inspiratory pressure and a rate sufficient to maintain normocapnia, as measured using a Raman scatter analyzer (Rascal II, Ohmeda, UT, USA). Percent hemoglobin saturation with oxygen (SpO2) was estimated using a pulse oximeter placed on the tongue (Rascal II). End-tidal isoflurane was hand-sampled in glass syringes and measured using an infrared analyzer (Beckman LB2, Sensormedics, CA, USA) that was calibrated against multiple standard gases that spanned the range of study concentrations. Systolic arterial pressure was measured indirectly by use of a Doppler probe (Model 811-BTS, Parks Medical Electronics, OR, USA) placed over the radial artery plus a sphygmomanometer with a cuff width equal to 40% of the antebrachial circumference. Body temperature was measured using an esophageal thermistor probe (400 series, YSI, OH, USA) that was calibrated against a certified standard mercury thermometer (SRM934-FC, ERTCO, IA, USA). Heating pads and forced air warmers were used to maintain body temperature between 38 and 39 °C. Lactated Ringer’s solution was administered through a 22-gauge medial saphenous catheter at 10 mL kg−1 hour−1.
Baseline isoflurane MAC was determined using a standard bracketing design and previously described methods (Brosnan et al. 2009). Briefly, cats were equilibrated at a constant isoflurane concentration for 20 minutes. After anesthetic and physiologic measurements were collected, a Martin forceps was clamped to the first ratchet on the distal tail for 1 minute or until the cat exhibited non-reflex movement. The end-tidal isoflurane concentration then was increased by 10–15% if the cat moved or was decreased by 10–15% if the cat did not move. After 20 minutes equilibration at the new isoflurane concentration, movement in response to forceps clamping was assessed at a site immediately proximal to the previous tail test. A single MAC value equaled the mean of the highest and lowest isoflurane concentrations that respectively allowed and prevented movement in response to noxious stimulation. For each cat, MAC was measured in duplicate and averaged.
Cats were assigned a priori to receive either 0.6 mg kg−1 of naltrexone HCl (ZooPharm, CO, USA) diluted to 10 mg mL−1 or an equivalent volume of 0.9% NaCl intravenously after every other movement test (every 40–60 minutes). This dose and frequency of naltrexone administration was selected because it completely reverses analgesia from very high dose remifentanil infusions in cats (Pypendop et al. 2011). The study drug—naltrexone or saline—for each cat was prepared in individual unmarked vials by an investigator who did not participate in MAC measurements. The order of drug or saline administration among study animals was determined using a random number table. Each cat received the other study treatment during a subsequent experiment 2 weeks later in which identical methods were used to measure MAC before (baseline) and after drug administration. The investigators who measured isoflurane MAC were always unaware of which treatment was administered. Isoflurane MAC during naltrexone or control treatment was re-determined in duplicate using methods identical to those described for baseline measurements. After each experiment, cats were recovered from anesthesia and were returned to the vivarium once awake and ambulatory.
Data were summarized as mean ± SD and checked for normality using Shapiro-Wilk tests. Treatment effects were evaluated using repeated-measures ANOVA with Dunn-Sidak corrections for pairwise comparisons. Differences were statistically significant when P<0.05.
Results
Baseline minimum alveolar concentration for isoflurane was 2.03 ± 0.12 %. Neither naltrexone nor saline affected the anesthetic potency of isoflurane (Table 1). For all MAC move/no-move brackets, the average percent change in end-tidal isoflurane concentration from the previous measurement was 9 ± 5%.
Table 1.
Mean responses (±SD) measured during baseline and drug treatment in six cats during the control study with saline and during the crossover study with naltrexone. Values represent the average of physiologic responses measured prior to stimulation. Neither saline nor naltrexone treatment caused a significant change from its respective baseline for any parameter.
| Measurement | Control | Naltrexone | ||
|---|---|---|---|---|
| Baseline | Saline | Baseline | Naltrexone | |
| MAC (% atm) | 2.02 ± 0.12 | 2.11 ± 0.13 | 2.04 ± 0.14 | 2.14 ± 0.31 |
|
| ||||
| HR (minute−1) | 176 ± 28 | 179 ± 13 | 171 ± 22 | 178 ± 19 |
|
| ||||
| fR (minute−1) | 22 ± 8 | 22 ± 7 | 24 ± 9 | 26 ± 13 |
|
| ||||
| SAP (mmHg) | 91 ± 17 | 82 ± 9 | 80 ± 17 | 76 ± 15 |
|
| ||||
| SpO2 (%) | 99 ± 1 | 99 ± 1 | 99 ± 1 | 98 ± 1 |
|
| ||||
| Temp (°C) | 38.5 ± 0.2 | 38.6 ± 0.1 | 38.5 ± 0.2 | 38.7 ± 0.1 |
|
| ||||
| PE′CO2 (mmHg) | 26 ± 2 | 26 ± 3 | 28 ± 2 | 25 ± 3 |
MAC = isoflurane minimum alveolar concentration, HR=heart rate, fR= respiratory rate, SAP= systolic arterial pressure, SpO2= arterial emoglobin oxygen saturation by pulse oximetry, PE′CO2= end-tidal CO2 partial pressure
Cats were anesthetized an average of 183 ± 44 minutes from the time of the first tail clamp test. Physiologic response measurements during experiments are shown in Table 1. All cats breathed spontaneously during the ventilator expiratory pause, resulting in a higher respiratory frequency and lower PE’CO2 than targeted. Naltrexone produced no statistically significant effect in any measured response. No differences between baseline and saline control responses were found, and since baseline measurements always preceded saline measurements, there were likewise no temporal differences.
Discussion
Naltrexone does not appear to affect isoflurane MAC in cats. The effects of opioid receptor antagonists on inhaled anesthetic requirement are identical across species (Harper et al. 1978; Pace & Wong 1979), even when the effects of opioid receptor agonists on anesthetic requirement are not (Michelsen et al. 1996; Criado & Gomez e Segura 2003; Brosnan et al. 2009).
Isoflurane MAC values in the present study are within the upper range of values previously reported in the cat (Ilkiw et al. 2002; Brosnan et al. 2009). A blinded, saline-controlled study design was utilized to allow detection of possible small isoflurane MAC increases with naltrexone while minimizing experimenter bias. Even though MAC is intended to provide reproducible measurement of an anesthetic EC50 (Eger et al. 1965), the expectation of an effect may generate results that are small and statistically significant, but not real (Liao et al. 2006). Yet despite our study design and use of small isoflurane bracketing concentrations, no naltrexone effect could be detected.
In conclusion, this work supports the view that opioid receptors with respect to immobility are irrelevant to the mechanism of inhaled anesthetic action (Harper et al. 1978; Pace & Wong 1979; Sonner et al. 2003; Liao et al. 2006). However, further insight into anesthetic mechanisms is possible with the cat. Since mu-opioid receptors in cats modulate the strength of monosynaptic reflexes as well as the activity of flexor reflex afferent interneurons, nociceptive afferent neurons, and dorsal horn neurons in laminae I-II (Steffens & Schomburg 2011), the lack of an isoflurane MAC effect from either a mu-opioid receptor agonist (Brosnan et al. 2009) or antagonist should eliminate these anatomic sites as plausible determinants of inhaled anesthetic potency.
Acknowledgments
This project was supported by a grant from the U.C. Davis Center for Companion Animal Health and by a grant from the National Institutes of Health (GM092821).
References
- Brosnan RJ, Pypendop BH, Siao KT, et al. Effects of remifentanil on measures of anesthetic immobility and analgesia in cats. Am J Vet Res. 2009;70:1065–1071. doi: 10.2460/ajvr.70.9.1065. [DOI] [PubMed] [Google Scholar]
- Criado AB, Gomez De Segura IA. Reduction of isoflurane MAC by fentanyl or remifentanil in rats. Vet Anaesth Analg. 2003;30:250–256. doi: 10.1046/j.1467-2995.2003.00123.x. [DOI] [PubMed] [Google Scholar]
- Eger EI, 2nd, Saidman LJ, Brandstater B. Minimum alveolar anesthetic concentration: a standard of anesthetic potency. Anesthesiology. 1965;26:756–763. doi: 10.1097/00000542-196511000-00010. [DOI] [PubMed] [Google Scholar]
- Harper MH, Winter PM, Johnson BH, et al. Naloxone does not antagonize general anesthesia in the rat. Anesthesiology. 1978;49:3–5. doi: 10.1097/00000542-197807000-00002. [DOI] [PubMed] [Google Scholar]
- Ilkiw JE, Pascoe PJ, Tripp LD. Effects of morphine, butorphanol, buprenorphine, and U50488H on the minimum alveolar concentration of isoflurane in cats. Am J Vet Res. 2002;63:1198–1202. doi: 10.2460/ajvr.2002.63.1198. [DOI] [PubMed] [Google Scholar]
- Liao M, Laster MJ, Eger EI, 2nd, et al. Naloxone does not increase the minimum alveolar anesthetic concentration of sevoflurane in mice. Anesth Analg. 2006;102:1452–1455. doi: 10.1213/01.ane.0000204254.87933.f6. [DOI] [PubMed] [Google Scholar]
- Michelsen LG, Salmenpera M, Hug CC, Jr, et al. Anesthetic potency of remifentanil in dogs. Anesthesiology. 1996;84:865–872. doi: 10.1097/00000542-199604000-00014. [DOI] [PubMed] [Google Scholar]
- Pace NL, Wong KC. Failure of naloxone and naltrexone to antagonize halothane anesthesia in the dog. Anesth Analg. 1979;58:36–39. [PubMed] [Google Scholar]
- Pypendop BH, Brosnan RJ, Ilkiw JE. Use of naltrexone to antagonize high doses of remifentanil in cats: a dose-finding study. Vet Anaesth Analg. 2011;38:594–597. doi: 10.1111/j.1467-2995.2011.00649.x. [DOI] [PubMed] [Google Scholar]
- Sonner JM, Antognini JF, Dutton RC, et al. Inhaled anesthetics and immobility: mechanisms, mysteries, and minimum alveolar anesthetic concentration. Anesth Analg. 2003;97:718–740. doi: 10.1213/01.ANE.0000081063.76651.33. [DOI] [PubMed] [Google Scholar]
- Steffens H, Schomburg ED. Spinal motor actions of the μ-opioid receptor agonist DAMGO in the cat. Neurosci Res. 2011 doi: 10.1016/j.neures.2011.01.011. [DOI] [PubMed] [Google Scholar]
