Skip to main content
European Spine Journal logoLink to European Spine Journal
. 2000 Jun;9(3):235–240. doi: 10.1007/s005860000146

Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients

T Laine 1, T Lund 1, M Ylikoski 1, J Lohikoski 1, D Schlenzka 1
PMCID: PMC3611394  PMID: 10905443

Abstract

We performed a randomised controlled study to assess the accuracy of computer-assisted pedicle screw insertion versus conventional screw placement under clinical conditions. One hundred patients scheduled for posterior thoracolumbar or lumbosacral pedicle screw instrumentation were randomised into two groups, either for conventional pedicle screw placement or computer-assisted screw application using an optoelectronic navigation system. From the computer-assisted group, nine patients were excluded: one because of an inadequate preoperative computed tomography study, seven because of problems with the specific instruments or the computer system, and one because of an intraoperative anesthesiological complication. Thus, there were 50 patients in the conventional group and 41 in the computer-assisted group, and the number of screws inserted was 277 and 219, respectively. There was no statistical difference between the groups concerning age, gender, diagnosis, type of operation performed, mean operating time, blood loss, or number of screws inserted. The time taken for screw insertion was significantly longer in the computer-assisted group. Postoperatively, screw positions were assessed by an independent radiologist using a sophisticated CT imaging protocol. The pedicle perforation rate was 13.4% in the conventional group and 4.6% in the computer-assisted group (P = 0.006). Pedicle perforations of more than 4 mm were found in 1.4% (4/277) of the screw insertions in the conventional group, and none in the computer-assisted group. Complications not related to pedicle screws were two L5 nerve root lesions, one end plate fracture, one major intraoperative bleeding and one postoperative death in the conventional group, and one deep infection in the computer-assisted group. In conclusion, pedicular screws were inserted more accurately with image-guided computer navigation than with conventional methods.

Keywords: Key words Spine surgery, Computer-assisted surgery, Pedicle screws, Image guidance, Randomised controlled trial

Full Text

The Full Text of this article is available as a PDF (35.0 KB).

Footnotes

Received: 11 October 1999 Revised: 2 February 2000 Accepted: 15 February 2000


Articles from European Spine Journal are provided here courtesy of Springer-Verlag