Skip to main content
European Spine Journal logoLink to European Spine Journal
. 2000 Feb;9(Suppl 1):S126–S130. doi: 10.1007/PL00008318

Posterior percutaneous spine instrumentation

G L Lowery 1, S S Kulkarni 1
PMCID: PMC3611442  PMID: 10766069

Abstract

Eighty consecutive cases of suprafascial pedicle screw stabilization were reviewed. Intraoperative fluoroscopy aided the percutaneous screw placement after structural anterior interbody graft(s) were placed. During routine outpatient hardware removal, all intradiscal fusions were stressed via the Shanz screws under fluoroscopy. Anterior reconstruction via a mini open approach coupled with this minimally invasive posterior approach led to a 96% successful fusion rate.

Keywords: Key words Minimally invasive, Posterior instrumentation, Percutaneous, Suprafascial, Pedicle screw