Abstract.
Twenty-eight (11 cemented and 17 noncemented) total hip arthroplasties (THA) were performed in 20 patients with rheumatoid arthritis (RA). The average age at operation was 42.1 years and the average follow-up was 10.8 years. There were two deep infections requiring removal of the prosthesis. Three cemented acetabular cups and one cemented femoral component were revised due to aseptic loosening. One cemented cup was loosened radiologically. One PCA polyethylene liner was revised because of significant wear. Both cemented and noncemented femoral components are capable of providing respectable results in RA patients. The relatively inferior results of THA among RA patients is due not only to the fixation method, but also to the poorer bone quality.
Résumé.
Vingt-huit arthroplasties totales de hanche (11 cimentées, 17 non-cimentées) ont été exécutées sur 20 malades atteints de polyarthrite rhumatoïde. L'âge moyen à l'opération était de 42,1 ans et la durée moyenne de suivi de 10,8 années. Deux infections profondes ont nécessité l'ablation de la prothèse. Trois composants cotyloidiens cimentés et un composant fémoral cimenté ont été révisé à cause d'un descellement aseptique. Un composant cotyloidien montre un descellement radiographique. Un insert de polyéthylène a été remplacé à cause d'une usure notable. Les composants fémoraux cimentés et non-cimentés ont la capacité de fournir un résultat acceptable dans le cas d'une polyarthrite rhumatoïde. Les résultats relativement inférieurs des prothèses totales chez ces malades proviennent non seulement de la méthode de fixation mais aussi d'une mauvaise qualité osseuse.
Full Text
The Full Text of this article is available as a PDF (27.7 KB).
Footnotes
Electronic Publication