Abstract
Background
The management of displaced distal tibial fractures is still controversial. The different internal fixation techniques are often burdened by relatively high complication rates. Minimally invasive techniques with ring fixators have been introduced as an alternative allowing immediate reduction and stabilization, avoiding a staged protocol. The aim of this prospective study was to analyze the clinical and radiographic outcome the Ilizarov technique in patients with distal metaphyseal tibial fractures, with or without intra-articular involvement.
Methods
Thirty-nine consecutive patients with isolated fractures treated with the Ilizarov technique were followed prospectively for one year. Depending on the type of fracture, 4 or 5 rings were used, in some cases with additional foot extension. Unrestricted weight-bearing was allowed in all cases. Pre- and post-operatively conventional radiographs, post-operative pain assessment and complications were evaluated. The function was evaluated clinically and with self-appraisal protocols: EQ-5D, NHP and FAOS.
Results
No patient developed compartment syndrome or deep venous thrombosis. Pin infections were frequent, but they were mostly superficial and were treated with antibiotics and/or the removal of isolated pins. Two patients required debridement. One of them had a deep infection and developed a residual deformity which was corrected and healed after re-operation. Another patient had a severe residual deformity. The fixator was removed after a median period of 16 weeks (range 11–30). The radiological results were poor in 5 patients but the overall self-appraisal showed satisfactory results in 36 patients.
Conclusions
The Ilizarov method allowed early definitive treatment with a low complication rate and a good clinical outcome.
Keywords: Distal tibial fractures, Ilizarov method, External fixation
Background
When treating distal tibial fractures, the goal is to achieve normal axial alignment and to reduce articular displacement if present, thereby regaining a stable, mobile and painless joint, while avoiding infections and wound complications [1].
The treatment of these fractures is challenging [2-5]. It is often difficult to assess the potential risk of surgical complications because of the variations in the clinical findings. Sometimes the injury can be more serious than initially expected, even in patients without articular involvement. One main reason is probably the underestimation of the soft-tissue injuries, not addressed in the fracture classification [6].
In intra-articular fractures, the sequential management principles outlined by Rüedi and Allgöwer [7] are generally accepted. The aim of the first step is to preserve length with a joint-bridging fixator or a fibular plate and, when the soft-tissue injuries permit, the definitive step is traditionally performed with screws and plates [8-11]. In less comminuted intra-articular fractures (Rüedi-Allgöwer types I and II), McFerran et al. reported a 54% risk of major complications [4]. There are studies indicating that it is possible to reduce the number and severity of complications using a staged protocol [9,12-15].
Even if extra-articular fractures are expected to be associated with less risk of treatment complications than intra-articular fractures, the proximity to the ankle and the vulnerable soft-tissue in the distal region increases the risk of complications compared with midshaft tibial fractures [16,17].
The union rate in these fractures is still reported as 2.4% and the malunion rate as 14.3% independent of the treatment approach [18]. The current knowledge indicates that is essential to consider the risk of soft-tissue complications and fracture malalignment when selecting the method of fixation [18,19].
When it comes to intra-articular distal tibial fractures, there are reports of the use of an initial joint-bridging fixator, subsequently converted to a non-bridging device, showing lower complication rates compared with internal fixation [20-23]. The use of primary circular fixators (in accordance with Ilizarov principles), with or without minimal internal osteosynthesis, has also been reported to reduce the complication rate in these fractures [24-28].
With the Ilizarov technique, it is always possible to treat the patients with an immediate one stage procedure [29,30], since reduction is less invasive, with minimal soft-tissue exposure and blood loss. If needed, this fixator also allows for adjustment of the alignment and for compression/distraction both during and after surgery. An additional advantage is that the fixation is stable enough to allow early weight-bearing [31,32].
At our department at the Skaraborg Central Hospital (Kärnsjukhuset) in Skövde, a referral trauma centre for a population of approximately 280.000 inhabitants, the Ilizarov external fixator was gradually introduced for complex distal tibial fractures in 2002 and since 2005, it has been the preferred treatment for displaced distal tibial fractures of all types where the soft tissues were impaired or at risk. The aim of this prospective study was to analyse the clinical and radiographic outcome using the Ilizarov technique in consecutive patients with distal metaphyseal tibial fractures, with or without intra-articular involvement.
Methods
The selection criteria in this study were as follows: patients aged 18–75 years, with displaced distal metaphyseal (defined by the Heim's square) tibial fractures with an angulation of more than 10 degrees in any plane and intra-articular fractures were included if the incongruence of the articular surface was more than 2 mm. Only patients with isolated fractures, without other disorders affecting gait, who were able to understand and follow instructions in Swedish, were enrolled after written informed consent to participate in the study was obtained.
The fractures were classified according to the AO classification [33]. Plafond fractures were also classified according to Rüedi and Allgöwer [7] and open fractures were classified according to Gustilo [34,35]. The soft-tissue damage was graded according to the Tscherne classification for closed fractures [36].
The operations were performed without a tourniquet and without any traction table. Arthroscopy or arthrotomies were not used. Biplane fluoroscopy was used during reduction, pin insertion and assembly of the frame. The fractures were reduced with traction and manual external pressure. If this did not lead to acceptable anatomical repositioning, the joint surfaces were reconstructed with percutaneously inserted elevators and/or a reduction forceps and/or wires with olives. The proximal ring was placed at the level of the fibular head. Additional stability was achieved using extra wires parallel to the articular surface with posts fixed on the distal ring (drop-wire technique). The syndesmosis and malleolar fragments could be stabilised with olive wires fixed to the ring on the lateral side or the medial side. All the wires were assembled and tensioned to a minimum of 120 kg. To achieve further stability of the system and to allow for unrestricted weight-bearing, additional rings were used in the tibia. Steel rings connected with steel rods were used (Smith & Nephew, Memphis, Tennessee, USA). Bone grafts were not used. All the operations were supervised or performed by one senior surgeon (TR).
Cloxacillin (2 g) was used as prophylaxis starting pre-operatively and continued with another two doses within 24 hours. Low-molecular heparin prophylaxis was given from the day of admission until 10 days after leaving the hospital. During the first 24 hours after surgery all patients had a postoperative continuous analgesia (PCA) pump with morphine/ketobemidon.
The “Kurgan protocol” [37] was used for postoperative dressing and the Checketts-Otterburns classification [38] was used to report pin infections.
Physiotherapy was started immediately postoperatively to maintain knee and ankle motion and the patients were allowed to start unrestricted weight-bearing.
The fractures were regarded as healed when antero-posterior and lateral radiographs showed a bridging callus in three of four cortices and/or the fracture was stable when stressed manually and the patients were able to walk without pain after the connecting rods had been removed.
The patients were followed clinically and radiographically after 2, 4, 8 and 12 weeks and one year. Additional clinical and radiographic assessments were made when necessary to evaluate fracture healing. The clinical one-year outcome, including the range of motion of the ankle, was assessed by an independent physiotherapist.
Pain and patient satisfaction were registered (VAS 100 mm) at four and 12 weeks and at the one year follow-up. The Swedish versions of the EuroQol [39] and the Nottingham Health Profile (NHP) [40,41] were used for patient self-appraisals at the same time intervals. The FAOS [42] questionnaire was added to the follow-up between 1–5 years postoperatively, Pain (VAS), EQ-5D and NHP questionnaires were repeated if the observation period exceeded one year.
Marsh and coworkers [43] modification of the criteria defined by Burwell and Charnley [44] was used to evaluate the articular reduction. This was done by one of the authors (TR) and separately by an independent surgeon for reliability. In the event of different judgements, the final evaluation was made by consensus.
Statistical analysis
Descriptive statistics as median and range was calculated. As the number of patients in the subgroups was small and as several of the variables were of ordinal data type, we decided to use non-parametric tests for statistical analysis. All the statistical tests were two-sided. For comparisons within the group we used Wilcoxon’s test and between the groups Mann–Whitney test. PASW statistics (SPSS) version 18 was used for all statistical analysis.
The study was approved by the regional ethical review board at Sahlgrenska University Hospital in Gothenburg (ID. 400–04).
Results
Between January 2005 and December 2010, 39 consecutive patients admitted to the emergency department fulfilled the inclusion criteria. Their median age was 50 years (range 20–70), 27 were women and 12 men. Nine patients were smokers. Individual data on the fractures are given in Table 1. The cause of the injury was falls in 25 patients, motor-vehicle accidents in 5, work accidents in 3, football accidents in 3 and riding accidents in 1 patient.
Table 1.
Case | Age | Injury | Energy | AO | Rüedi-Allgöwer | Gustilo | Tscherne | Extension from the joint/mm | Bone defect/mm | Ilizarov rings | Foot extension | Pin infection | Checketts-Otterbuns |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
20 |
fall |
low |
A2 |
|
|
|
117 |
|
4 |
|
2 |
III + III |
2 |
62 |
fall |
low |
C1 |
I |
|
|
109 |
|
4 |
|
1 |
II |
3 |
57 |
riding |
high |
C1 |
I |
2 |
|
58 |
|
4 |
|
0 |
|
4 |
59 |
fall |
low |
A2 |
|
|
1 |
136 |
|
4 |
|
1 |
II |
5 |
39 |
traffic |
high |
C2 |
II |
|
|
66 |
|
4 |
yes |
0 |
|
6 |
55 |
work |
low |
A2 |
|
|
|
152 |
|
4 |
|
0 |
|
7 |
56 |
fall |
low |
A2 |
|
|
|
118 |
|
4 |
|
1 |
II |
8 |
39 |
fall |
low |
C1 |
II |
|
|
122 |
|
4 |
|
2 |
III |
9 |
33 |
traffic |
high |
A3 |
|
1 |
|
75 |
|
4 |
|
1 |
II |
10 |
59 |
fall |
low |
C1 |
I |
|
|
85 |
|
4 |
|
2 |
III + III |
11 |
70 |
fall |
low |
A2 |
|
|
|
172 |
|
4 |
|
1 |
II |
12 |
61 |
work |
low |
C1 |
I |
|
1 |
123 |
|
4 |
|
1 |
II |
13 |
58 |
fall |
low |
A3 |
|
|
1 |
126 |
|
4 |
|
0 |
|
14 |
50 |
fall |
high |
C2 |
II |
1 |
|
83 |
12 × 5 |
4 |
|
1 |
III |
15 |
46 |
fall |
low |
A1 |
|
1 |
|
107 |
|
4 |
|
0 |
|
16 |
43 |
fall |
low |
C1 |
I |
|
|
168 |
|
4 |
|
3 |
II + II + III |
17 |
29 |
traffic |
high |
A3 |
|
1 |
|
241 |
|
5 |
|
1 |
II |
18 |
50 |
trafic |
high |
C2 |
II |
2 |
|
61 |
|
4 |
yes |
1 |
II |
19 |
46 |
fall |
low |
C1 |
I |
|
|
176 |
|
4 |
|
3 |
II + III + VI |
20 |
39 |
fall |
low |
A2 |
|
|
|
172 |
|
4 |
|
1 |
II |
21 |
63 |
fall |
low |
A2 |
|
|
|
127 |
|
4 |
|
0 |
|
22 |
42 |
fall |
low |
A2 |
|
1 |
|
195 |
|
5 |
|
2 |
II + II |
23 |
21 |
fall |
low |
A2 |
|
|
|
93 |
|
4 |
|
0 |
|
24 |
42 |
fall |
low |
C3 |
III |
1 |
|
59 |
|
4 |
|
0 |
|
25 |
66 |
fall |
high |
C3 |
III |
|
|
76 |
16 × 15 |
3 |
yes |
0 |
|
26 |
51 |
fall |
low |
C1 |
I |
2 |
|
147 |
|
4 |
|
1 |
III |
27 |
62 |
fall |
low |
C3 |
III |
|
|
143 |
|
4 |
yes |
2 |
II + III |
28 |
54 |
traffic |
high |
A2 |
|
|
|
176 |
|
4 |
|
2 |
II + II |
29 |
54 |
fall |
low |
C1 |
I |
|
|
158 |
|
4 |
|
2 |
II + III |
30 |
68 |
fall |
low |
A2 |
|
|
|
167 |
|
4 |
|
3 |
II + III + IV |
31 |
56 |
fall |
low |
A1 |
|
|
|
133 |
|
4 |
|
2 |
II + III |
32 |
43 |
skiing |
low |
A3 |
|
|
|
250 |
|
4 |
yes |
2 |
II + III |
33 |
44 |
skiing |
low |
A1 |
|
|
|
152 |
|
4 |
|
2 |
II + III |
34 |
48 |
fall |
low |
C1 |
I |
|
|
127 |
|
4 |
|
2 |
II + III |
35 |
56 |
traffic |
high |
C1 |
I |
|
1 |
137 |
|
4 |
|
1 |
III |
36 |
24 |
fall |
high |
C1 |
II |
|
|
147 |
8 × 5 |
4 |
yes |
1 |
III |
37 |
42 |
fall |
low |
A1 |
|
|
|
273 |
|
4 |
|
0 |
|
38 |
70 |
fall |
low |
A3 |
|
|
|
110 |
|
4 |
yes |
0 |
|
39 | 49 | fall | low | A1 | 143 | 4 | 0 |
Five patients had type A1 fractures, eleven had A2, five had A3, twelve had C1, three C2 and three C3. Of 18 patients with C-type fractures, ten had Rüedi-Allgöwer I, five had type II, and three type III. Thirty-seven fractures had a diaphyseal extension, which extended more than 10 cm above the articular surface in 30 patients. Thirty patients had closed fractures and nine patients had open fractures, six Gustilo I and three Gustilo II. The soft-tissue damage in the closed fractures was graded according to the Tscherne classification as grade 0 in twenty-six and grade I in four patients. In summary, almost all the fractures included in this study had at least one factor which could increase the risk of complication under the treatment, such as high-energy trauma, communition, soft-tissue injury or long fracture line.
The majority of the patients underwent surgery on the day of admission or within two days. In three patients, the operation was delayed for another 2–3 days because of a high load at the operation department. In the majority of cases four rings, connected with steel rods, were used. In four patients with more comminuted fractures, a foot fixation with trans-calcaneal and trans-metatarsal wire fixation without hinges (foot extension), was added to the construction. Six minor re-operations were performed under general anaesthesia because of the re-insertion of wires after breakage or to improve fracture alignment. The median duration of surgery, which includes assembling the frame and dressings, was shorter for the extra-articular fractures, 152 min (range 50–224), compared with intra-articular fractures, 165 min (range 72–314). Patients with a foot extension had this fixation removed after 4–6 weeks and the Ilizarov fixator was removed under local anaesthesia after 17 weeks (range 12–30) in the extra-articular fractures and 15 weeks (range 11–22) in the intra-articular fractures.
The total amount of morphine/ketobemidon (PCA pump) varied between 0 and 141 mg (median 43 mg). The demand for additional analgesics was low. All the patients were discharged directly to their homes after a median of 5 days post-operatively (range 2–10) when they were able to walk with crutches and independently climb stairs.
The timing of surgery and postoperative care are shown in Table 2, where the fractures have been divided in two groups, extra- and intra-articular. The differences between the groups are not statistically significant.
Table 2.
Extra-articular Factures (n = 21) | Intra-articular Fractures (n = 18) | |||
---|---|---|---|---|
|
Median |
Range |
Median |
Range |
Surgery delay (days) |
2 |
(0–24) |
1 |
(0–5) |
Operation time (min) |
152 |
(50–224) |
165 |
(72–314) |
Hospital stay (days) |
5 |
(3–10) |
5 |
(2–7) |
External fixation (weeks) | 17 | (12–30) | 15 | (11–22) |
A total of 157 rings, with 551 wires, were used, constituting 1.102 potential pin-infection sites.
One patient (# 30), with an A2 fracture, had a pin tract infection grade 4, which was successfully treated with soft-tissue curettage. After the fixator had been removed, in one patient (# 19), with a C1 fracture, a deep S.aureus infection was diagnosed in an area with a previous pin scar. The lesion was treated with curettage, but there was a progressive loss of reduction. This was treated successfully with stabilisation and progressive correction with a new Ilizarov external fixator application for a period of 23 weeks combined with antibiotic therapy (clindamycin) for 12 weeks.
Forty-two minor pin site infections were observed: 24 Checketts-Otterburns II in 19 patients which were treated with short-term antibiotics, and 18 Checketts-Otterburns III in 15 patients treated with the removal of the offending wire (Table 1).
No patients developed compartment syndrome or deep vein thrombosis.
Compared with the uninjured, 3 patients had reduced dorsiflexion of more than 10° (14°, 15°, 16°). The plantar flexion was reduced by more than 10° in 7 patients in the A group (median 15°, range 12°-23°) and in 9 patients in the C group (median 22°, range 18°- 33°). The results are shown in Table 3.
Table 3.
|
Extra-articular Fractures (n = 21) |
Intra-articular Fractures (n = 18) |
||||||
---|---|---|---|---|---|---|---|---|
Uninjured | Injured | Uninjured | Injured | |||||
Ankle dorsiflexion |
20° |
(0-50°) |
18° |
(0-50°) |
21° |
(10-29°) |
17° |
(4-26°) |
Ankle plantarflexion | 38° | (12-55°) | 30° | (11-52°) | 33° | (16-56°) | 19° | (4-48°) |
With the exception of one patient (#19), all the fractures healed when the fixator was removed (see above). According to the radiological findings using the modified Burwell and Charnley classification, 13 patients were rated as good, 21 as fair and 5 had poor results at the one-year follow-up. The radiological results are shown together with self-appraisals (FAOS and VAS-pain) in Table 4. In Table 5, the radiological results in patients with at least one parameter classified as poor and/or pin tract infection at one year are shown, together with FAOS and VAS-pain.
Table 4.
Intra-articular fractures | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Case | AO | Central fragment/mm | Talar subluxation/mm | Mortise widening (mm) | Varus | Valgus | Anterior | Posterior | Burwell & Charnley | FAOS Pain | FAOS Symptom | FAOS ADL | FAOS Sport | FAOS Qol | VAS Satisfaction/mm |
2 |
C1 |
<2 |
<0.5 |
<0.5 |
9 |
|
|
5 |
fair |
|
|
|
|
|
0 |
3 |
C1 |
<2 |
<0.5 |
<0.5 |
|
|
|
7 |
fair |
100 |
93 |
100 |
100 |
94 |
7 |
5 |
C2 |
<2 |
<0.5 |
<0.5 |
8 |
|
|
4 |
fair |
72 |
21 |
93 |
35 |
38 |
18 |
8 |
C1 |
<2 |
<0.5 |
<0.5 |
3 |
|
|
|
good |
100 |
100 |
100 |
100 |
100 |
38 |
10 |
C1 |
<2 |
<0.5 |
<0.5 |
|
10 |
10 |
|
poor |
|
|
|
|
|
8 |
12 |
C1 |
<2 |
<0.5 |
<0.5 |
11 |
|
2 |
|
poor |
72 |
89 |
90 |
60 |
75 |
31 |
14 |
C2 |
<2 |
<0.5 |
<0.5 |
8 |
|
|
|
fair |
92 |
86 |
100 |
100 |
94 |
10 |
16 |
C1 |
<2 |
<0.5 |
<0.5 |
|
|
|
|
good |
47 |
64 |
68 |
20 |
44 |
27 |
18 |
C2 |
<2 |
<0.5 |
<0.5 |
|
|
|
|
good |
61 |
75 |
85 |
35 |
56 |
7 |
19 |
C1 |
<2 |
<0.5 |
<0.5 |
|
3 |
|
7 |
fair |
33 |
61 |
85 |
40 |
63 |
49 |
24 |
C3 |
<2 |
<0.5 |
<0.5 |
|
9 |
6 |
|
fair |
33 |
14 |
71 |
0 |
19 |
54 |
25 |
C3 |
<2 |
<0.5 |
<0.5 |
|
12 |
|
3 |
poor |
31 |
21 |
60 |
5 |
0 |
47 |
26 |
C1 |
<2 |
<0.5 |
<0.5 |
6 |
|
3 |
|
fair |
39 |
64 |
72 |
5 |
75 |
76 |
27 |
C3 |
9 |
6 |
5 |
|
16 |
|
1 |
poor |
94 |
57 |
97 |
70 |
63 |
7 |
29 |
C1 |
<2 |
<0.5 |
<0.5 |
|
|
2 |
|
good |
94 |
93 |
97 |
85 |
88 |
7 |
34 |
C1 |
<2 |
<0.5 |
<0.5 |
8 |
|
2 |
|
fair |
67 |
54 |
85 |
40 |
31 |
41 |
35 |
C1 |
<2 |
<0.5 |
<0.5 |
1 |
|
|
4 |
good |
100 |
100 |
100 |
100 |
94 |
0 |
36 |
C1 |
<2 |
<0.5 |
<0.5 |
|
|
|
|
good |
89 |
54 |
100 |
70 |
56 |
2 |
Extra-articular fractures | |||||||||||||||
Case |
|
|
|
|
Varus |
Valgus |
Anterior |
Posterior |
Burwell & Charnley |
FAOS Pain |
FAOS Symptom |
FAOS ADL |
FAOS Sport |
FAOS Qol |
VAS Satisfaction/mm |
1 |
A2 |
|
|
|
|
|
7 |
|
fair |
|
|
|
|
|
0 |
4 |
A2 |
|
|
|
|
4 |
|
8 |
fair |
100 |
100 |
100 |
100 |
100 |
18 |
6 |
A2 |
|
|
|
|
8 |
1 |
|
fair |
83 |
68 |
93 |
70 |
75 |
0 |
7 |
A2 |
|
|
|
|
|
|
8 |
fair |
|
|
|
|
|
26 |
9 |
A3 |
|
|
|
|
5 |
5 |
|
fair |
|
|
|
|
|
0 |
11 |
A2 |
|
|
|
|
2 |
|
|
good |
100 |
100 |
97 |
90 |
81 |
0 |
13 |
A3 |
|
|
|
|
5 |
4 |
|
fair |
97 |
86 |
96 |
100 |
88 |
38 |
15 |
A1 |
|
|
|
5 |
|
8 |
|
fair |
100 |
86 |
100 |
100 |
100 |
0 |
17 |
A3 |
|
|
|
|
4 |
2 |
|
fair |
100 |
93 |
99 |
95 |
100 |
0 |
20 |
A2 |
|
|
|
|
|
|
|
good |
|
|
|
|
|
54 |
21 |
A2 |
|
|
|
6 |
|
4 |
|
fair |
100 |
100 |
100 |
100 |
100 |
7 |
22 |
A2 |
|
|
|
|
1 |
|
2 |
good |
67 |
36 |
81 |
25 |
44 |
30 |
23 |
A2 |
|
|
|
|
|
5 |
|
fair |
|
|
|
|
|
0 |
28 |
A2 |
|
|
|
8 |
|
|
|
fair |
81 |
75 |
94 |
60 |
56 |
47 |
30 |
A2 |
|
|
|
2 |
|
|
1 |
good |
78 |
71 |
87 |
40 |
63 |
17 |
31 |
A1 |
|
|
|
|
5 |
|
|
fair |
75 |
54 |
81 |
90 |
38 |
22 |
32 |
A3 |
|
|
|
|
|
|
12 |
poor |
64 |
57 |
79 |
20 |
38 |
11 |
33 |
A1 |
|
|
|
|
2 |
|
2 |
good |
81 |
64 |
97 |
90 |
69 |
3 |
37 |
A1 |
|
|
|
1 |
|
2 |
|
good |
100 |
86 |
100 |
80 |
69 |
4 |
38 |
A3 |
|
|
|
|
|
2 |
|
fair |
100 |
93 |
100 |
85 |
100 |
0 |
39 | A1 | 1 | 2 | good | 100 | 93 | 100 | 95 | 88 | 7 |
Table 5.
Nr | Intra/extra articular | B&C | Pin-tract infection | EQ-5D | FAOS Pain | FAOS Symptom | FAOS ADL | FAOS Sport | FAOS QoL | VAS mm |
---|---|---|---|---|---|---|---|---|---|---|
10 |
C1 |
Poor |
No |
1.000 |
— |
— |
— |
— |
— |
8 |
12 |
C1 |
Poor |
No |
0.727 |
72 |
89 |
90 |
60 |
75 |
31 |
19 |
C1 |
Fair |
Yes |
0.656 |
33 |
61 |
85 |
40 |
63 |
49 |
25 |
C3 |
Poor |
No |
0.620 |
31 |
21 |
60 |
5 |
0 |
47 |
27 |
C3 |
Poor |
No |
0.125 |
94 |
57 |
97 |
70 |
63 |
7 |
30 |
A2 |
Good |
Yes |
0.796 |
78 |
71 |
87 |
40 |
63 |
17 |
32 | A3 | Poor | No | 0.767 | 64 | 57 | 79 | 20 | 38 | 11 |
One patient (# 25) had a residual deformity and developed post-traumatic sympathetic dystrophy which was treated with an ankle joint arthrodesis after 1.5 years. This procedure did not, however, relieve the pain.
The pain (VAS), patient satisfaction (VAS), EQ5D, NHP total score at different time intervals and FAOS are shown in Table 6. The pain values (VAS) had reached acceptable levels at 4 weeks but did not improve further between 4 and 12 weeks post-operatively. Patient satisfaction (VAS) with the treatment was generally high in both groups at all follow-up assessments. The NHP total score showed a relatively moderate impact at four and twelve weeks and was almost normal at one year. The EQ-5D values showed a similar pattern. After one year, there were no clinically important differences between the A and C groups in terms of pain (VAS), patient satisfaction (VAS), EQ5D, NHP total score or FAOS. Intra-articular fractures showed a tendency to result in lower FAOS subscores, as shown in Figure 1. The groups were compared with the results from the literature [42,45,46].
Table 6.
Median with range | Time of assessment | Extra-articular fractures | Intra-articular fractures | ||
---|---|---|---|---|---|
Pain (VAS) |
4 weeks |
27 |
(7–63) |
28 |
(8–58) |
12 weeks |
29 |
(3–56) |
26 |
(0–78) |
|
1 year |
7 |
(0–54) |
14 |
(0–76) |
|
At FAOS |
6.5 |
(0–67) |
7.5 |
(0–49) |
|
Patient satisfaction (VAS) |
4 weeks |
14 |
(1–29) |
9 |
(7–47) |
12 weeks |
24 |
(0–52) |
14 |
(3–35) |
|
1 year |
8 |
(0–61) |
20 |
(0–53) |
|
At FAOS |
6.5 |
0(0–67) |
7.5 |
(0–49) |
|
NHP total |
4 weeks |
20.2 |
(4.9-83.3) |
12.4 |
(0–48.6) |
12 weeks |
16.8 |
(0–69.8) |
15.4 |
(0.-48.7) |
|
1 year |
1.8 |
(0–76.3) |
2.7 |
(0–39.8) |
|
At FAOS |
1.8 |
(0–65) |
4.1 |
(0–54) |
|
EQ5D |
4 weeks |
0.62 |
(−0.07-0.88) |
0.52 |
(0.15-0.73) |
12 weeks |
0.69 |
(0.19-1.0) |
0.62 |
(0.02-0.73) |
|
1 year |
1.0 |
(0.29-1.0) |
0.80 |
(0.20-1.0) |
|
At FAOS | 0.93 | (0.66-1.0) | 0.80 | (0-36-1.0) |
At one year, all the patients had returned to their previous jobs, while sporting activities were severely restricted in the majority of cases (Additional file 1).
Discussion
The most important finding in this study was the satisfactory outcome of the Ilizarov method, independently of fracture pattern. Using an identical protocol for both intra- and extra-articular fractures, it was possible to operate on all patients without delay, regardless of the status of soft tissues, the size of the distal fragment, and the intra-articular fracture lines or whether a staged protocol should be used. This is also emphasised by the absence of clinically important differences in the present study in terms of the results between the intra- and extra-articular fractures.
In the present study there is a mixture of fractures and from a radiological point of view the treatment of many of these fractures might seem to be uncontroversial.
However, despite the fact that the trauma in a majority of the patients was classified as low energy, most of these patients had other complicating conditions, such as soft-tissue injuries, diaphyseal fracture extension etc. (Table 1). In other words, several of the factors considered when choosing the method of treatment are difficult to evaluate.
Twenty-one of 39 patients in our study had extra-articular fractures, which could possibly have been treated with open reduction and internal fixation using intramedullary nails or plates. However, the use of intramedullary nails in extra-articular distal tibial fractures is technically demanding, because of the widening of the medullary canal in the metaphysis, which raises concern regarding the biomechanical stability and the subsequent increased risk of malunion [47]. The more modern technique with percutaneous angle stable plate fixation is more reliable with a lower rate of complications than previous plate techniques [48-50]. However, until now, both superficial and deep infections have continued to be a problem and there is also a high rate of hardware complications requiring plate removal [51-56]. In this study, thirty patients had a significant diaphyseal extension of the fracture, indicating that a fairly long plate would have to be used.
One common problem with external fixators of all types is the risk of skin-penetrating infections (pin site and pin tract infections). The incidence of pin site infections reported in the literature varies from 4.5% to 71% [57] and pin tract infection varies from 10% to 50% [58]. Parameswaran et al. [59], found that ring fixators had the lowest incidence of infection compared with unilateral and hybrid fixators. Pin site infections were frequent in the present study; however, they did not constitute a major problem, as all the infections healed following minor intervention. In the present study, 3.7% of the pin sites became infected, while only two patients had more severe pin tract infections.
Ristiniemi used hybrid ring fixators in different types of intra-articular fracture, with or without osteoinduction [60]. In the group without osteoinduction, the healing period was 21 weeks, which compares favorably with the 15 weeks for similar fractures in our study.
The amount of residual deformity that can be accepted is still controversial [43]. It is difficult to correlate the postoperative radiological findings to the clinical result and to use this as a prognostic factor. In a 10-year follow-up, Etter and Ganz [61] retrospectively examined how the fracture pattern and quality of reduction correlated to postoperative arthritis in 41 patients with plafond fractures treated with internal fixation. Anatomical reduction was correlated to a better prognosis in terms of a lower risk of post-traumatic osteoarthritis, but it did not guarantee a good clinical result. Severe osteoarthritis present at late follow-up did not correlate with poor subjective or objective function. DeCoster et al. [62] came to the same conclusions using the rank order method to assess the quality of articular reduction in the outcome of displaced intra-articular distal tibia fractures in 25 patients treated with articulated external fixation and limited internal fixation. With ten B3, three C1, ten C2 and twelve C3 fractures, Marsh et al. [63] rated the quality of reduction as good in 14 ankles, fair in 15 and poor in 6, using the same radiological evaluation method as in the present study. They did not find any association between the fracture type and the clinical outcome measures. In their study, the majority of the patients had some limitation with regard to recreational activities, with an inability to run as the most common complaint. Fourteen patients had to change jobs due to the ankle injury.
Williams et al. [64] determined which fracture- and patient-specific variables affected the outcome most in 29 patients with tibial plafond fractures. They evaluated their patients a minimum of two years from the time of the injury. Outcome was assessed by four independent measures; radiographic osteoarthritis score, subjective ankle score, the Short Form-36 (SF-36), and the patient’s ability to return to work. Interestingly, the four outcomes did not correlate with one another. They also found that the ability to return to work was affected by the patient’s level of education and highlighted the difficulties of predicting patient outcome in, these severe articular fractures.
Pollak et al. [65] evaluated eighty patients, treated with bridging external fixation and/or internal fixation, at a mean of 3.2 years after injury. They analysed general health, walking ability, range of motion, pain, and stair-climbing as well employment status. Their general conclusion was that pilon fractures could have persistent and devastating consequences for patient-health and well-being. In approximately 30% of their patients, the injury prevented a return to work.
In the present study, several self-appraisals were used in our study, both general (NHP and EQ-5D) and more specific (Pain in the affected limb -VAS and FAOS). The patients with metaphyseal fractures without joint engagement were in an almost normal situation at one year postoperatively, but the intra-articular fractures were also better than the reported by the patients in the above mentioned studies. Despite successful treatment and improvement in their outcomes, the FAOS subscores showed the lowest values for Sports and QoL activities especially in the C fractures. Apart from this, they did not differ significantly, compared with patients after operated ankle ligaments, trimalleolar or distal fibular fractures [42,45,46]. All the patients returned to work while sporting activities were severely restricted in both groups without significant differences, but we observed a trend towards more seriously affected Sports and QoL for the group with extra-articular fractures.
The results of the follow-up observed in this study might differ in the future in terms of functional outcome. Marsh et al. [63] claimed that, although tibial plafond fractures have a negative effect on ankle function and pain, at a minimum of five years after the injury, few patients required secondary reconstructive procedures because these symptoms tend to decrease during a long time period after the acute injury.
Conclusions
The study shows that it is possible to achieve a satisfactory outcome, in distal metaphyseal tibia fractures, with the Ilizarov technique allowing early definitive treatment and unrestricted weight-bearing. The fractures were treated immediately after the injury, regardless of soft-tissue damage. This was done with a similar low complication rate in both the extra-articular and the intra-articular fractures. Patient compliance was good. The residual deformities were within the range in which the risk of developing post-traumatic osteoarthritis can be expected to be low.
Abbreviations
AO: Arbeitsgemeinschaft für Osteosynthesefragen; ORIF: Open Reduction Internal Fixation.
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
TR conducted the study, treated the patients and wrote the manuscript. JK and LN participated in the design of the study which LN supervised. They both helped to analyse the results and revised the manuscript together with BE. All the authors agreed on the final content of the manuscript.
Pre-publication history
The pre-publication history for this paper can be accessed here:
Supplementary Material
Contributor Information
Telmo Ramos, Email: telmo.ramos@vgregion.se.
Jón Karlsson, Email: jon.karlsson@vgregion.se.
Bengt I Eriksson, Email: bengt.eriksson@gu.se.
Lars Nistor, Email: lars.nistor@vgregion.se.
Acknowledgements
We thank biostatistician Salmir Nasic at the Research Fund at Skaraborg Hospital, Sweden, for help with the statistical discussion of the data.
This study was supported by the Research Fund at Skaraborg Hospital, Sweden.
The funding agency was not involved in the design or the performance of the study; manuscript preparation or in the decision to submit the manuscript for publication.
References
- Rockwood and Green’s. Fractures in Adults. 6. Philadelphia: Lippincott Williams & Wilkins; 2006. [Google Scholar]
- Joveniaux P, Ohl X, Harisboure A, Berrichi A, Labatout L, Simon P, Mainard D, Vix N, Dechoux E. Distal tibia fractures: management and complications of 101 cases. Int Orthop. 2010;34–4:583–588. doi: 10.1007/s00264-009-0832-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dillin L, Slabaugh P. Delayed wound healing, infection, and non-union following open reduction and internal fixation of tibial plafond fractures. J Trauma. 1986;26–12:1116–1119. doi: 10.1097/00005373-198612000-00011. [DOI] [PubMed] [Google Scholar]
- McFerran MA, Smith SW, Boulas HJ, Schwartz HS. Complications encountered in the treatment of pilon fractures. J Orthop Trauma. 1992;6–2:195–200. doi: 10.1097/00005131-199206000-00011. [DOI] [PubMed] [Google Scholar]
- Teeny SM, Wiss DA. Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications. Clin Orthop Relat Res. 1993;292:108–117. [PubMed] [Google Scholar]
- Tull F, Borrelli. Soft-tissue injury associated with closed fractures: evaluation and management. J Am Acad Orthop Surg. 2003;11:431–438. doi: 10.5435/00124635-200311000-00007. [DOI] [PubMed] [Google Scholar]
- Ruedi TP, Allgower M. The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop Relat Res. 1979;138:105–110. [PubMed] [Google Scholar]
- Sirkin M, Sanders R, DiPasquale T, Herscovici D Jr. A staged protocol for soft tissue management in the treatment of complex pilon fractures. J Orthop Trauma. 1999;13:78–84. doi: 10.1097/00005131-199902000-00002. [DOI] [PubMed] [Google Scholar]
- Patterson MJ, Cole JD. Two-staged delayed open reduction and internal fixation of severe pilon fractures. J Orthop Trauma. 1999;13:85–91. doi: 10.1097/00005131-199902000-00003. [DOI] [PubMed] [Google Scholar]
- Blauth M, Bastian L, Krettek C, Knop C, Evans S. Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma. 2001;15–3:153–160. doi: 10.1097/00005131-200103000-00002. [DOI] [PubMed] [Google Scholar]
- Ma CH, Yu SW, Tu YK, Yen CY, Yeh JJ, Wu CH. Staged external and internal locked plating for open distal tibial fractures. Acta Orthop. 2010;81–3:382–386. doi: 10.3109/17453674.2010.487244. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sirkin M, Sanders R, DiPasquale T, Herscovici D Jr. A staged protocol for soft tissue management in the treatment of complex pilon fractures. J Orthop Trauma. 2004;18(Suppl 8):S32–S38. doi: 10.1097/00005131-200409001-00005. [DOI] [PubMed] [Google Scholar]
- Dickson KF, Montgomery S, Field J. High energy plafond fractures treated by a spanning external fixator initially and followed by a second stage open reduction internal fixation of the articular surface-preliminary report. Injury. 2001;32(Suppl 4):92–98. doi: 10.1016/s0020-1383(01)00163-2. [DOI] [PubMed] [Google Scholar]
- Gardner MJ, Mehta S, Barei DP, Nork SE. Treatment protocol for open AO/OTA type C3 pilon fractures with segmental bone loss. J Orthop Trauma. 2008;22–7:451–457. doi: 10.1097/BOT.0b013e318176b8d9. [DOI] [PubMed] [Google Scholar]
- Mauffrey C, Vasario G, Battiston B, Lewis C, Beazley J, Seligson D. Tibial pilon fractures: a review of incidence, diagnosis, treatment, and complications. Acta Orthop Belg. 2011;77:432–440. [PubMed] [Google Scholar]
- Zelle B, Bhandari M, Espiritu M, Koval K, Zlowodzki M. Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma. 2006;20–1:76–79. doi: 10.1097/01.bot.0000202997.45274.a1. [DOI] [PubMed] [Google Scholar]
- Robinson CM, McLauchlan GJ, McLean IP, Court-Brown CM. Distal metaphyseal fractures of the tibia with minimal involvement of the ankle: classification and treatment by locked intramedullary nailing. J Bone Joint Surg Br. 1995;77-B:781–787. [PubMed] [Google Scholar]
- Casstevens C, Le T, Archdeacon MT, Wyrick JD. Management of extra-articular fractures of the distal tibia: intramedullary Nailing versus Plate fixation. J Am Acad Orthop Surg. 2012;20–11:675–683. doi: 10.5435/JAAOS-20-11-675. [DOI] [PubMed] [Google Scholar]
- Newman SD, Mauffrey CP, Krikler S. Distal metadiaphyseal tibial fractures. Injury. 2011;42–10:975–984. doi: 10.1016/j.injury.2010.02.019. [DOI] [PubMed] [Google Scholar]
- Tornetta P III, Weiner L, Bergman M, Watnik N, Steuer J, Kelly M, Yang E. Pilon fractures: treatment with combined internal and external fixation. J Orthop Trauma. 1993;7–6:489–496. doi: 10.1097/00005131-199312000-00001. [DOI] [PubMed] [Google Scholar]
- Wrysch B, McFerran MA, McAndrew M, Limbird TJ, Harper MC, Johnson KD, Schwartz HS. Operative treatment of fractures of the tibial plafond. A randomized, prospective study. J Bone Joint Surg Am. 1996;78–11:1646–1657. doi: 10.2106/00004623-199611000-00003. [DOI] [PubMed] [Google Scholar]
- Ristiniemi J, Flinkkila T, Hyvonen P, Lakovaara M, Pakarinen H, Jalovvara P. RhBMP-7 accelerates the healing in distal tibial fractures treated by external fixation. J Bone Joint Surg Br. 2007;89–2:265–272. doi: 10.1302/0301-620X.89B2.18230. [DOI] [PubMed] [Google Scholar]
- Barbieri R, Schenk R, Koval K, Aurori K, Aurori B. Hybrid external fixation in the treatment of tibial plafond fractures. Clin Orthop Rel Res. 1996;332:16–22. doi: 10.1097/00003086-199611000-00004. [DOI] [PubMed] [Google Scholar]
- Mc Donald MG, Burgess RC, Bolano LE, Nicholls PJ. Ilizarov treatment of pilon fractures. Clin Orthop Rel Res. 1996;325:232–238. doi: 10.1097/00003086-199604000-00028. [DOI] [PubMed] [Google Scholar]
- Lovisetti G, Agus MA, Pace F, Capitani D, Sala F. Management of distal tibial intra-articular fractures with circular external fixation. Strategies Trauma Limb Reconstr. 2009;4–1:1–6. doi: 10.1007/s11751-009-0050-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vasiliadis ES, Grivas TB, Psarakis SA, Evangelos P, Kaspiris A, Triantafyllopoulos G. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia. J Orthop Surg Res. 2009;4:35. doi: 10.1186/1749-799X-4-35. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vidyadhara S, Rao SK. Ilizarov treatment of complex tibial pilon fractures. Int Orthop. 2006;30–2:113–117. doi: 10.1007/s00264-005-0038-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Demiralp B, Atesalp AS, Bozkurt M, Bek D, Tasatan E, Ozturk C, Basbozkurt M. Spiral and oblique fractures of distal one-third of tibia-fibula: treatment results with circular external fixator. Ann Acad Med Singapore. 2007;36–4:267–271. [PubMed] [Google Scholar]
- Ilizarov GA. In: Collected Scientific Works of the Kurgan Regional Scientific Medical Society. Ilizarov GA, editor. Kurgan: Union of Soviet Socialists Republic; 1954. A new principle of osteosynthesis using crossing wires and rings; pp. 145–160. [Google Scholar]
- Ilizarov GA. Transosseous osteosynthesis. 1. Berlin Heidelberger New York: Springer Verlag; 1992. [Google Scholar]
- Ylmaz E, Belhan O, Karakurt L, Arslan N, Serin E. Mechanical performance of hybrid Ilizarov external fixator in comparision with the Ilizarov circular external fixator. Clin Biomech. 2003;18–6:518–522. doi: 10.1016/s0268-0033(03)00073-1. [DOI] [PubMed] [Google Scholar]
- Fleming B, Paley D, Kristiansen T, Pope M. A biomechanical analysis of the Ilizarov external fixator. Clin Orthop Relat Res. 1989;241:95–105. [PubMed] [Google Scholar]
- Müller ME, Nazarian S, Koch P, Schatzker J. The comprehensive classification of fractures of long bones. New York: Springer; 1990. [Google Scholar]
- Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg Am. 1976;58–4:453–458. [PubMed] [Google Scholar]
- Gustilo RB, Mendoza RM, Williams DN. Problems in the management of type III (severe) open fractures: a new classification of type III open fractures. J Trauma. 1984;24:742–746. doi: 10.1097/00005373-198408000-00009. [DOI] [PubMed] [Google Scholar]
- Tscherne H, Oestern HJ. In: Fractures with soft tissue injuries. Tscherne H, Gotzen L, editor. Berlin: Springer Verlag; 1984. Pathophysiology and classification of soft tissue injuries associated with fractures; pp. 1–9. [Google Scholar]
- Davies R, Holt N, Nayagam S. The care of pin sites with external fixation. J Bone Joint Surg Br. 2005;87–5:716–719. doi: 10.1302/0301-620X.87B5.15623. [DOI] [PubMed] [Google Scholar]
- Checketts RG, Otterburn M, Mac Eachern AG. Pin track infection; definition, incidence and prevention. Int J Orthop Trauma. 1993;3(Suppl 3):16–18. [Google Scholar]
- Brooks R. EuroQol: the current state of play. Health Policy. 1996;37:53–72. doi: 10.1016/0168-8510(96)00822-6. [DOI] [PubMed] [Google Scholar]
- Hunt SM, McEwan T. The development of a subjective health indicator. Soc of Health and Illness. 1980;2:231–246. doi: 10.1111/1467-9566.ep11340686. [DOI] [PubMed] [Google Scholar]
- Wiklund I, Romanus B, Hunt SM. Self-assessed disability in patients with arthrosis of the hip joint. Reliability of the Swedish version of the Nottingham Health Profile. Int Disabil Studies. 1988;10:159–163. doi: 10.3109/09638288809164068. [DOI] [PubMed] [Google Scholar]
- Roos EM, Brandsson S, Karlsson J. Validation of the foot and ankle outcome score for ankle ligament reconstruction. J Foot Ankle Int. 2001;22–10:788–794. doi: 10.1177/107110070102201004. [DOI] [PubMed] [Google Scholar]
- Marsh JL, Buckwalter J, Gelberman R, Dirschl D, Olson S, Brown T, Llinias A. Articular fractures: does an anatomical reduction really change the result? J Bone Joint Surg Am. 2002;84A–7:1259–1271. [PubMed] [Google Scholar]
- Burwell HN, Charnley AD. The treatment of displaced fractures of the ankle by rigid internal fixation and early joint movement. J Bone Joint Surg. 1965;47:634–660. [PubMed] [Google Scholar]
- Krenk D, Molinero K, Mascarenhas L, Muffley M, Altman G. Results of minimally invasive distal fibular plate osteosynthesis. J Trauma-Inj Inf & Critical Care. 2009;66–2:570–575. doi: 10.1097/TA.0b013e31818936ff. [DOI] [PubMed] [Google Scholar]
- Berkes MB, Little MTM, Lazaro LE, Sculco PK, Cymerman RM, Daigl M, Helfet DL, Lorich DG. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation. J Bone Joint SurgBr. 2012;94–11:1567–1572. doi: 10.1302/0301-620X.94B11.28662. [DOI] [PubMed] [Google Scholar]
- Bedi A, Le TT, Karunakar MA. Surgical treatment of nonarticular distal tibia fractures. J Am Acad Orthop Surg. 2006;14–7:406–416. doi: 10.5435/00124635-200607000-00003. [DOI] [PubMed] [Google Scholar]
- Redfern DJ, Syed SU, Davies. Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury. 2004;35–6:615–620. doi: 10.1016/j.injury.2003.09.005. [DOI] [PubMed] [Google Scholar]
- Bahari S, Lenehan B, Khan H, McElwain J. Minimally invasive percutaneous plate fixation of distal tibia fractures. Acta Orthop Belg. 2007;73:635–640. [PubMed] [Google Scholar]
- Aksekili MA, Celik I, Arslan AK, Kalkan T, Ugurlu M. The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthop Traumatol Turc. 2012;46–3:161–167. doi: 10.3944/aott.2012.2597. [DOI] [PubMed] [Google Scholar]
- Schouten R, Vincent A. Percutaneous plating of distal tibia fractures. J Bone Joint Surg Br. 2009;93(Suppl 3):376. [Google Scholar]
- Borg T, Larsson S, Lindsjö U. Percutaneous plating of distal tibial fractures. Preliminary results. Injury. 2004;35–6:608–614. doi: 10.1016/j.injury.2003.08.015. [DOI] [PubMed] [Google Scholar]
- Ronga M, Longo UG, Maffulli N. Minimally invasive locked plating of distal tibia fractures is safe and effective. Clin Orthop Relat Res. 2010;468–4:975–982. doi: 10.1007/s11999-009-0991-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hazarika S, Schakravarthy J, Cooper J. Minimally invasive locking plate osteosynthesis for fractures of the distal tibia- results in 20 patients. Injury. 2006;37–9:877–887. doi: 10.1016/j.injury.2006.06.002. [DOI] [PubMed] [Google Scholar]
- Lau TW, Leung F, Chan CF, Chow SP. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008;32–5:697–703. doi: 10.1007/s00264-007-0384-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Collinge C, Protzman R. Outcomes of minimally invasive plate osteosynthesis for metaphyseal distal tibia fractures. J Orthop Trauma. 2010;24–1:24–29. doi: 10.1097/BOT.0b013e3181ac3426. [DOI] [PubMed] [Google Scholar]
- Cavusoglu AT, Er MS, Inal S, Ozsoy MH, Dincel VE, Sakaogullari A. Pin site care during circular external fixation using two different protocols. J Orthop Trauma. 2009;23–10:724–730. doi: 10.1097/BOT.0b013e3181abbc31. [DOI] [PubMed] [Google Scholar]
- Mahan J, Seligson D, Henry SL, Hynes P, Dobbins J. Factors in pin tract infections. Orthopaedics. 1991;14:305–308. [PubMed] [Google Scholar]
- Parameswaran AD, Roberts CS, Seligson D, Voor M. Pin tract infection with contemporary external fixation: How much of a problem? J Orthop Trauma. 2003;17–7:503–507. doi: 10.1097/00005131-200308000-00005. [DOI] [PubMed] [Google Scholar]
- Ristiniemi J. External fixation of tibial pilon fractures and fracture healing. Acta Orthop. 2007;78–326(Suppl 3):5–34. [PubMed] [Google Scholar]
- Etter C, Ganz R. Long-term results of tibial plafond fractures treated with open reduction and internal fixation. Arch Orthop Trauma Surg. 1991;110–6:277–283. doi: 10.1007/BF00443458. [DOI] [PubMed] [Google Scholar]
- DeCoster TA, Willis MC, Marsh JL, Williams TM, Nepola JV, Dirschl DR, Hurwitz SR. Rank order analysis of tibial plafond fractures: does injury nor reduction predict outcome? Foot Ankle Int. 1999;20–1:44–49. doi: 10.1177/107110079902000110. [DOI] [PubMed] [Google Scholar]
- Marsh JL, Weigel DP, Dirschl DR. Tibial plafond fractures. How do these ankles function over time? J Bone Joint Surg Am. 2003;85A-2:287–295. [PubMed] [Google Scholar]
- Williams TM, Nepola JV, DeCoster TA, Hurwitz SR, Dirschl DR, Marsh JL. Factors affecting outcome in tibial plafond fractures. Clin Orthop Relat Res. 2004;423:93–98. doi: 10.1097/01.blo.0000127922.90382.f4. [DOI] [PubMed] [Google Scholar]
- Pollak AN, McCarthy ML, Bess RS, Agel J, Swiontkowski MF. Outcomes after treatment of high-energy tibial plafond fractures. J Bone Joint Surg Am. 2003;85–10:1893–1900. doi: 10.2106/00004623-200310000-00005. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.