Hörning, M., S. Kidoaki, …, K. Yoshikawa, 2012. Rigidity Matching between Cells and the Extracellular Matrix Leads to the Stabilization of Cardiac Conduction. Biophys. J. 102:379–387.
Eq. 1 in the paper of Hoerning et al. should be corrected as
(1) |
The same mistake on the factor is found in the quoted paper (1). Through this correction, all measured substrate and cell rigidities should be increased by a factor 3. Thus, the cell rigidity changes to (13.2+/− 1.8) kPa. This error does not affect the results or the conclusions that were stated in the manuscript.
Reference
- 1.Sneddon I. The Relation between Load and Penetration in the Axisymmetric Boussinesq Problem for a Punch of Arbitrary Profile. Inter. J. Engineer. Sci. 1965;3:47–57. [Google Scholar]