Skip to main content
Experimental and Therapeutic Medicine logoLink to Experimental and Therapeutic Medicine
. 2013 Mar 21;5(5):1486–1490. doi: 10.3892/etm.2013.1024

Predictors of diffuse-type in-stent restenosis following drug-eluting stent implantation

CHANG-BUM PARK 1,, HOON-KI PARK 2
PMCID: PMC3671824  PMID: 23737904

Abstract

Diffuse-type in-stent restenosis (ISR) is known to be associated with a higher rate of restenosis than focal-type ISR. Therefore, it is clinically important to identify the determinants of diffuse-type ISR following drug-eluting stent (DES) implantation. We investigated the clinical, procedural and angiographic variables for predicting diffuse-type ISR following DES implantation. A total of 173 ISR lesions in 159 patients (diffuse-type: 61 lesions, focal-type: 112 lesions) following DES implantation from February 2003 to May 2008 were included in this study. Clinical, procedural and quantitative coronary angiographic variables were analyzed to determine predictors of diffuse-type ISR following DES implantation. Univariate analysis showed that the absence of hypertension [odds ratio (OR), 0.493; 95% confidence interval (CI), 1.025–4.103, P=0.042], use of a paclitaxel-eluting stent (PES) (OR, 3.318; 95% CI, 1.730–6.365, P<0.001) and smaller post-stenting minimal luminal diameter (MLD; OR, 0.368, 95% CI, 0.168–0.808, P=0.013) were significantly associated with diffuse-type ISR. However, use of a PES (OR, 3.957; 95% CI, 1.977–7.922, P<0.001) and smaller post-stenting MLD (OR, 0.320; CI, 0.140–0.731, P=0.007) were only independent predictors of diffuse-type ISR by multivariate analysis. Diabetes was not a predictor of diffuse-type ISR. The use of a PES and the post-stenting MLD were related to diffuse-type ISR following DES implantation.

Keywords: stent, restenosis, predictor

Introduction

Routine stent implantation has been shown to have a better procedural success rate and clinical outcome than balloon angioplasty (1,2). However, restenosis and repeat revascularization remain significant clinical problems limiting the long-term success of stent implantation (13).

Recent development of the drug-eluting stent (DES) has reduced the incidence of stent-related restenosis to <10%, but has not eliminated it completely (4,5). Furthermore, diffuse-type in-stent restenosis (ISR; ≥10 mm in length) has also been shown to be associated with a higher rate of recurrent restenosis and poor prognosis than focal-type ISR in the DES (6), as well as in the bare metal stent (BMS) (79). However, little data is available concerning predictors of diffuse-type ISR following DES implantation.

Therefore, the present study sought to identify the predictors of diffuse-type ISR following successful DES implantation.

Patients and methods

Patients

Between February 2003 and May 2008, 2,485 consecutive patients underwent coronary DES implantation in 3,466 lesions at Seoul Veterans Hospital (Seoul, Korea). Angiographic follow-up was obtained for 2,403 eligible lesions in 1,722 patients (follow-up rate, 69.3%), and the overall angiographic restenotic rate was 7.9% [189 lesions: sirolimus-eluting stent (SES), 107 lesions (56.6%); paclitaxel-eluting stent, (PES), 82 lesions (43.4%)]. Of these patients, 159 patients with 173 ISR lesions were enrolled in this study. Patients were excluded from this study if the treatment site was in the left main coronary artery (n=12) or venous bypass graft (n=4). This study was conducted in accordance with the Declaration of Helsinki and with approval from the institutional review board from the Kyung Hee University Hospital at Gangdong (Seoul, Korea).

Stenting procedure

An SES (Cypher™; Cordis Corporation, Miami, FL, USA) or PES (Taxus™; Boston Scientific, Natric, MA, USA) was used in all patients. Stent implantation was performed according to standard techniques, and stents were selected at the physician’s discretion. Complete lesion coverage was recommended as well as angiographic optimization with <20% residual stenosis by visual estimation. During the procedure, patients received a bolus of 100 IU/kg heparin, with a repeated bolus of 2,000 IU heparin to maintain the activated clotting time of ≥300 sec. All patients were treated with aspirin 100–200 mg/day indefinitely and clopidogrel 75 mg/day for ≥6 months.

Angiographic analysis

Coronary angiograms were analyzed by two experienced investigators who were not aware of the purpose of the study. The reference vessel diameter, the percent diameter stenosis and the minimal luminal diameter were determined using an online quantitative coronary angiographic system (Xelera Cath 1.1, Philips, The Netherlands) at baseline, subsequent to the procedure and again at follow-up. The angiographic measurement was made during the end-diastole following intracoronary nitroglycerin administration.

Definitions

Demographic, clinical, angiographic and procedural characteristics were prospectively entered into the angiographic database of Seoul Veterans Hospital. Angiographic restenosis was defined as a diameter stenosis of ≥50% occurring in the segment inside the stent or a 5-mm segment proximal or distal to the stent at follow-up angiography. Patterns of restenosis were defined as follows; focal type: restenosis with a ≥50% luminal narrowing and <10 mm in length; and diffuse type: restenosis with a ≥50% lumimal narrowing and ≥10 mm in length.

Statistical analysis

Data were expressed as the mean ± SD for continuous variables and frequencies for categorical variables. Continuous variables were compared by unpaired Student’s t-test and categorical variables by Chi-square test. Univariate regression analysis was performed on variables with a P-value of less than 0.05 to identify determinants of restenosis and variables found to be significant by univariate analysis were entered into multivariate analysis to determine their independent relationship to restenosis. A P-value of <0.05 was considered to indicate a statistically significant result.

Results

Focal-type ISR developed in 112 lesions and diffuse-type ISR in 61 lesions. Follow-up angiography after coronary stenting was conducted a mean of 6.63±1.70 months after the procedure. Clinical, angiographic, and procedural variables were analyzed in this study and are summarized in Tables I and II. The diffuse-type ISR group had a lower incidence of absence of hypertension than the focal-type ISR group (37.3 vs. 54.6%, respectively, P=0.041), and a higher incidence of use of a PES (63.9 vs. 34.8%, respectively, P<0.001) and post-stenting minimal luminal diameter (MLD; 2.50±0.39 vs. 2.67±0.44 mm, respectively, P=0.011). However, diabetes was not significantly more common in diffuse-type ISR (19.6 vs. 28.7%, respectively, P=0.221).

Table I.

Clinical characteristics of 159 study patients.

Characteristics Diffuse-type ISR (n=51) Focal-type ISR (n=108) P-value
Age, years 58.0±12.4 59.0±9.9 0.602
Male gender 37 (72.5%) 76 (70.4%) 0.777
Diabetes 10 (19.6%) 31 (28.7%) 0.221
Hypertension 19 (37.3%) 59 (54.6%) 0.041
Current smoking 19 (37.3%) 32 (29.6%) 0.336
Hypercholesterolemia (≥200 mg/dl) 12 (23.5%) 28 (25.9%) 0.745
Prior PCI 11 (21.6%) 24 (22.0%) 0.926
Prior CABG 0 (0%) 1 (0.9%) 1.000
Clinical presentation 0.757
  Stable angina 27 (52.9%) 65 (60.2%)
  Unstable angina 13 (25.5%) 21 (19.4%)
  NSTEMI 4 (7.8%) 10 (9.3%)
  STEMI 7 (13.7%) 12 (11.2%)
LVEF (%) 59.2±8.8 58.3±8.5 0.540
Multivessel disease 28 (54.9%) 51 (47.2%) 0.336

Data are presented as mean ± SD or n (%). PCI, percutaneous coronary intervention; CABG, coronary artery bypass surgery; STEMI, ST-segment elevation myocardial infarction; NSTEMI, non-ST-segment elevation myocardial infarction; LVEF, left ventricular ejection fraction.

Table II.

Procedural and angiographic variables for 173 study lesions.

Variables Diffuse-type ISR (n=61) Focal-type ISR (n=112) P-value
Lesion characteristics
  Target coronary vessel 0.973
    Left anterior descending 35 (57.4%) 66 (58.9%)
    Left circumflex 7 (11.5%) 13 (11.6%)
    Right coronary 19 (31.1%) 33 (29.5%)
  Type B2/C lesions 51 (83.6%) 102 (91.0%) 0.772
  Chronic total occlusion 7 (11.5%) 12 (10.7%) 0.878
  Restenotic lesion 6 (9.8%) 13 (11.6%) 0.722
  Ostial lesion 2 (3.3%) 10 (8.9%) 0.162
  Bifurcation 7 (11.5%) 18 (16.1%) 0.411
Procedural characteristics
  Balloon/artery ratio 1.26±0.18 1.28±0.19 0.568
  Stent per lesion 1.66±0.87 1.73±0.74 0.572
  Stent length per lesion, mm 42.2±25.1 45.0±23.7 0.453
  Use of PES 39 (63.9%) 39 (34.8%) <0.001
Quantitative coronary angiography
  Lesion length, mm 35.9±19.7 38.4±20.8 0.429
  Reference vessel diameter, mm 2.71±0.53 2.77±0.43 0.448
  Pre-intervention
    Minimal luminal diameter, mm 0.71±0.49 0.80±0.55 0.286
    Diameter stenosis, % 72.3±17.4 70.5±19.6 0.544
  Post-intervention
    Minimal luminal diameter, mm 2.50±0.39 2.67±0.44 0.011
    Diameter stenosis, % 4.63±16.0 2.8±14.8 0.350
  Postprocedural TIMI 3 flow 58 (95.1%) 111 (99.1%) 0.126
  Acute gain 1.76±0.50 1.88±0.60 0.202
  IVUS guidance 36 (59.0%) 81 (72.3%) 0.074

Data are presented as mean ± SD or n (%). PES, paclitaxel-eluting stent; TIMI 3, thrombolysis in myocardial infarction grade 3; IVUS, intravascular ultrasound.

Univariate analysis revealed that the absence of hypertension [odds ratio (OR), 0.493; 95% confidence interval (CI), 1.025–4.103, P=0.042], use of a PES (OR, 3.318; 95% CI, 1.730–6.365, P<0.001), and smaller post-stenting MLD (OR, 0.368; 95% CI, 0.168–0.808, P=0.013) were significantly associated with diffuse-type ISR. However, use of a PES (OR, 3.957; 95% CI, 1.977–7.922, P<0.001) and smaller post-stenting MLD (OR, 0.320; CI, 0.140–0.731, P=0.007) were only independent predictors of diffuse-type ISR by multivariate analysis (Table III).

Table III.

Predictors of angiographic restenosis by logistic regression analysis.

Variables Univariate analysis Multivariate analysis


OR 95% CI P-value OR 95% CI P-value
Use of PES 3.318 1.730–6.365 <0.001 3.957 1.977–7.922 <0.001
Post-stenting MLD 0.368 0.168–0.808 0.013 0.320 0.140–0.731 0.007
Hypertension 0.493 0.249–0.975 0.042 0.507 0.253–1.014 0.055

OR, odds ratio; CI, confidence interval; PES, paclitaxel-eluting stent; MLD, minimal luminal diameter.

Discussion

This study showed that post-stenting MLD and the use of a PES are independent predictors of diffuse-type ISR. These results suggest that the largest possible post-stenting MLD and prudent selection of the type of DES are required to reduce the incidence of diffuse-type ISR.

Coronary stenting has become a standard therapy for coronary artery disease due to the simplicity of the procedure and its favorable outcomes. Recent randomized trials showed that the implantation of a DES dramatically reduced restenosis (4,5). However, restenosis continues to affect a significant number of patients with more complex lesions; therefore, more effective strategies are required.

Intravascular ultrasound has shown that ISR is the result of neointimal hyperplasia rather than elastic recoil (10,11). Mehran et al(9) developed an angiographic classification of ISR according to the geographic distribution of the intimal hyperplasia, demonstrating that repeat revascularization increases with increasing ISR class: pattern I (focal ISR, 19%), pattern II (diffuse ISR within the stent, 35%), pattern III (diffuse ISR outside the stent, 50%) and pattern IV (totally occluded ISR, 83%). Diffuse-type ISR reflects exaggerated neointimal hyperplasia as compared with the focal-type ISR and carries a higher rate of re-restenosis following BMS implantation and balloon angioplasty. Recently developed DESs have been shown to be effective in reducing binary restenosis in de novo lesions in randomized controlled trials by 0-9% (4,5). While this number is a great improvement over the results seen with BMS implantation, it is certainly not negligible. Furthermore, diffuse-type ISR following DES implantation is rare but continues to be associated with a higher rate of re-restenosis (6), as does BMS implantation (12,13). For these reasons, the identification of the predictors of diffuse-type ISR in DES implantation may play an important role in determining treatment strategies and prognosis.

In DES as well as BMS implantation, post-stenting MLD is one of the most powerful coronary morphologic predictors of restenosis among the many determinants of coronary morphology. Our data demonstrated that a smaller post-stenting MLD is associated with diffuse-type ISR. However, little is known concerning the relationship between diffuse-type ISR and post-stenting MLD. We suggest that a greater stent area may contribute to a decreased rate of diffuse-type ISR in patients with DES implantation but more investigative studies are required to confirm this hypothesis.

The current study also demonstrated that the use of a PES is associated with diffuse-type ISR. Other studies have reported similar results; the incidence of diffuse-type ISR following PES implantation has been reported to be 38–50% (14,15), compared with 0–14% following SES implantation (16,17). Furthermore, large clinical trials have also demonstrated that the SES is superior to the PES with regard to angiographic restenotic rate and late luminal loss (18,19). Whether this finding represents a more exaggerated neointimal response to the PES remains to be seen in the ongoing and the upcoming randomized trials between the two types of DES currently available on the market.

With DES, as with as BMS, diabetes continues to be an independent risk predictor of restenosis. Furthermore, a previous study (20) showed that diabetes was associated with diffuse-type ISR following BMS implantation. However, our results revealed that diabetes was not a predictor of restenosis following DES implantation, suggesting that the characteristics of ISR may be significantly different in the DES than in the BMS in diabetic patients but additional data are required to confirm this.

There were several potential limitations to the present study. Firstly, the choice of DES was made by the physician, which may have lead to a possible selection bias. Secondly, this study was a retrospective, single center study. Finally, our study was limited by the incomplete use of intravascular ultrasound. Despite these limitations, this study is based on one of the largest angiographic databases, and has identified independent predictors of diffuse-type ISR in DES implantation.

References

  • 1.Stone GW, Grines CL, Cox DA, Garcia E, Tcheng JE, Griffin JJ, Guagliumi G, Stuckey T, Turco M, Carroll JD, Rutherford BD, Lansky AJ, Controlled Abciximab and Device Investigation to Lower Late Angioplasty Complications (CADILLAC) Investigators Comparison of angioplasty with stenting, with or without abciximab, in acute myocardial infarction. N Eng J Med. 2002;346:957–966. [Google Scholar]
  • 2.Grines CL, Cox DA, Stone GW, Garcia E, Mattos LA, Giambartolomei A, Brodie BR, Madonna O, Eijgelshoven M, Lansky AJ, O’Neill WW, Morice MC, Stent Primary Angioplasty in Myocardial Infarction Study Group Coronary angioplasty with or without stent implantation for acute myocardial infarction. N Eng J Med. 1999;341:1949–1956. doi: 10.1056/NEJM199912233412601. [DOI] [PubMed] [Google Scholar]
  • 3.Odell A, Gudnason T, Andersson T, Jidbratt H, Grip L. One-year outcome after percutaneous coronary intervention for stable and unstable angina pectoris with or without application of general usage of stents in unselected European patient groups. Am J Cardiol. 2002;90:112–118. doi: 10.1016/s0002-9149(02)02431-1. [DOI] [PubMed] [Google Scholar]
  • 4.Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE, SIRIUS Investigators Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Eng J Med. 2003;349:1315–1323. doi: 10.1056/NEJMoa035071. [DOI] [PubMed] [Google Scholar]
  • 5.Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME, TAXUS-IV Investigators A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Eng J Med. 2004;350:221–231. doi: 10.1056/NEJMoa032441. [DOI] [PubMed] [Google Scholar]
  • 6.Saia F, Lemos PA, Arampatizis CA, Hoye A, Degertekin M, Tanabe K, Sianos G, Smits PC, van der Giessen WJ, de Feyter PJ, van Domburg RT, Serruy PW. Routine sirolimus eluting stent implantation for unselected in-stent restenosis: insights from the rapamycin eluting stent evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry. Heart. 2004;90:1183–1188. doi: 10.1136/hrt.2003.025536. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Ragosta M, Samady H, Gimple LW, Sarembock IJ, Fenster M, Powers ER. Percutaneous treatment of focal vs. diffuse in-stent restnosis: A prospective randomized comparison of conventional therapies. Catheter Cardiovasc Interv. 2004;61:344–349. doi: 10.1002/ccd.10779. [DOI] [PubMed] [Google Scholar]
  • 8.Ong AT, Aoki J, McFadden EP, Serruys PW. Classification and current treatment options of in-stent restenosis. Present status and future perspectives. Herz. 2004;29:187–194. doi: 10.1007/s00059-004-2574-4. [DOI] [PubMed] [Google Scholar]
  • 9.Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF, Pichard AD, Kent KM, Stone GW, Leon MB. Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome. Circulation. 1999;100:1872–1878. doi: 10.1161/01.cir.100.18.1872. [DOI] [PubMed] [Google Scholar]
  • 10.Hoffmann R, Mintz GS, Mehran R, Pichard AD, Kent KM, Satler LF, Popma JJ, Wu H, Leon MB. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents. J Am Coll Cardiol. 1998;31:43–49. doi: 10.1016/s0735-1097(97)00438-5. [DOI] [PubMed] [Google Scholar]
  • 11.Dussaillant GR, Mintz GS, Pichard AD, Kent KM, Satler LF, Popma JJ, Wong SC, Leon MB. Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis. J Am Coll Cardiol. 1995;26:720–724. doi: 10.1016/0735-1097(95)00249-4. [DOI] [PubMed] [Google Scholar]
  • 12.Bauters C, Banos JL, Van Belle E, McFadden EP, Lablanche JM, Bertrand ME. Six-month angiographic outcome after successful repeat percutaneous intervention for in-stent restenosis. Circulation. 1998;97:318–321. doi: 10.1161/01.cir.97.4.318. [DOI] [PubMed] [Google Scholar]
  • 13.Yokoi H, Kimura T, Nakagawa Y, Nosaka H, Nobuyoshi M. Long-term clinical and quantitative angiographic follow-up after the Palmaz-Schatz stent restenosis. J Am Coll Cardiol. 1996;27:224A. [Google Scholar]
  • 14.Iakovou I, Schmidt T, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Cosgrave J, Gerckens U, Grube E, Colombo A. Angiographic patterns of restenosis after paclitaxel-eluting stent implantation. J Am Coll Cardiol. 2005;45:805–806. doi: 10.1016/j.jacc.2004.12.012. [DOI] [PubMed] [Google Scholar]
  • 15.Stones GW, Ellis SG, Cannon L, Mann T, Greenberg JD, Spriggs D, O’Shaughnessy CD, DeMaio S, Hall P, Popma JJ, Koglin J, Russell ME, TAXUS V Investigators Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial. JAMA. 2005;294:1215–1223. doi: 10.1001/jama.294.10.1215. [DOI] [PubMed] [Google Scholar]
  • 16.Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K, Hoye A, Degertekin M, Daemen J, McFadden E, Hofma S, Smits PC, de Feyter P, van der Giessen WJ, van Domburg RT, Serruys PW. Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. Circulation. 2003;108:257–260. doi: 10.1161/01.CIR.0000083366.33686.11. [DOI] [PubMed] [Google Scholar]
  • 17.Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M, Liistro F, Carlino M, Airoldi F, Chieffo A, Mario CD. Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. Circulation. 2003;107:2178–2180. doi: 10.1161/01.CIR.0000070592.04766.36. [DOI] [PubMed] [Google Scholar]
  • 18.Windecker S, Remondino A, Eberli FR, Jüni P, Räber L, Wenaweser P, Togni M, Billinger M, Tüller D, Seiler C, Roffi M, Corti R, Sütsch G, Maier W, Lüscher T, Hess OM, Egger M, Meier B. Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization. N Eng J Med. 2005;353:653–662. doi: 10.1056/NEJMoa051175. [DOI] [PubMed] [Google Scholar]
  • 19.Dibra A, Kastrati A, Mehilli J, Pache J, Schühlen H, von Beckerath N, Ulm K, Wessely R, Dirschinger J, Schömig A, ISAR-DIABETES Study Investigators Paclitaxeleluting or sirolimus-eluting stents to prevent restenosis in diabetic patients. N Eng J Med. 2005;353:663–670. doi: 10.1056/NEJMoa044372. [DOI] [PubMed] [Google Scholar]
  • 20.Lee SG, Lee CW, Hong MK, Park HK, Kim JJ, Park SW, Park SJ. Predictors of diffuse-type in-stent restenosis after coronary stent implantation. Catheter Cardiovasc Interv. 1999;47:406–409. doi: 10.1002/(SICI)1522-726X(199908)47:4<406::AID-CCD5>3.0.CO;2-P. discussion 410. [DOI] [PubMed] [Google Scholar]

Articles from Experimental and Therapeutic Medicine are provided here courtesy of Spandidos Publications