Skip to main content
Clinical Endoscopy logoLink to Clinical Endoscopy
. 2013 May 31;46(3):219–223. doi: 10.5946/ce.2013.46.3.219

Optimal and Safe Bowel Preparation for Colonoscopy

Won Moon 1,
PMCID: PMC3678056  PMID: 23767029

Abstract

Effective colonoscopy requires an adequate level of cleansing as a basic component. This review will describe a compact review about general considerations in bowel preparation for colonoscopy and specific considerations for various patients. A low-fiber diet instead of a regular diet on the day before colonoscopy is an independent predictor of adequate bowel preparation. Improved bowel cleansing does not result from the routine use of enemas or prokinetics in addition to oral bowel preparation. For morning colonoscopy, a split method of 4 L polyethylene glycol on the day before and the day of colonoscopy is recommended, while patients scheduled for afternoon colonoscopy typically receive a full method of 4 L polyethylene glycol on the day of the procedure. Valid alternatives are 2 L polyethylene glycol plus ascorbic acid or 2 L sodium picosulphate plus magnesium citrate. Although there are no statistically significant differences between polyethylene glycol and oral sodium phosphate for colon cleansing, polyethylene glycol-based bowel preparation is advisable in most situations because of safety concerns.

Keywords: Colonoscopy, Preparation, Polyethylene glycols, Ascorbic acid, Magnesium

INTRODUCTION

Colonoscopy is the standard method for evaluating the colon. Cecal intubation and polyp detection rates are two key indicators associated with the quality of bowel cleansing prior to this procedure. Effective colonoscopy requires an adequate level of cleansing.1,2 Patients with inadequate levels of bowel cleansing may need examinations rescheduled or force practitioners to organize alternative investigations.3

At the same time, the discomfort from bowel preparation may affect the acceptability of colonoscopy for colon cancer screening.4 Although these preparations are generally safe and well-tolerated, there are potential risks associated with the use of oral bowel-cleansing agents. Harm is more likely to result from bowel preparation in patients who have definite contraindications (gastrointestinal obstruction or perforation, ileus or gastric retention, severe acute inflammatory bowel disease or toxic megacolon, reduced levels of consciousness, hypersensitivity to any of the ingredients, inability to swallow without aspiration, and ileostomy). Common complications in those without contraindications include hypovolemia and electrolyte disturbances, such as hypokalemia, hyponatremia and hypermagnesemia.5 The aim of this article was to review general considerations for colonoscopy bowel preparations and more focused concerns for specific patients.

GENERAL CONSIDERATIONS

Diet

A low-fiber diet on the day before colonoscopy is an independent predictor of adequate bowel preparation rather than a regular diet and is more frequent in satisfactory colon cleanliness; it is also better tolerated than a clear liquid diet.6-9 A low-fiber diet for more than 24 hours prior to colonoscopy has not shown a relationship with any aspect of the colonoscopy process.

Adjuncts

Improved bowel cleansing does not result from the routine use of enemas or prokinetics in addition to oral bowel preparation.10,11 However, mosapride or itopride may reduce nausea, vomiting, bloating, and abdominal pain that may be experienced during bowel preparation.12,13 The administration of simethicone with bowel preparation may decrease the amount of bubbles in the colon, and it has no impact on colon cleanliness and the definite efficacy of colonoscopy for detection of lesions.14

Main oral bowel-cleansing solution and timing

Patients scheduled for a morning colonoscopy are often prescribed a split method of 4 L polyethylene glycol (PEG) on the day before and again on the day of the procedure. When compared with a full dosage of 4 L PEG on the previous day, the split method significantly improves the incidence of satisfactory colon cleanliness, significantly increases patient compliance and significantly decreases nausea.15 In the case of afternoon colonoscopy, a full dose of 4 L PEG on the day of colonoscopy provides better colon cleanliness, less sleep disturbances, and less bloating.16,17

Valid alternatives may include a split method for morning colonoscopy or a full-dose method for afternoon colonoscopy of 2 L PEG plus ascorbic acid (PEGA) or of 2 L sodium picosulphate plus magnesium citrate (SPMC), particularly for elective outpatient colonoscopy.18 The time interval between the last dose of bowel preparation agents and the colonoscopy start time should be no longer than 4 hours.19-21 SPMC provides similar colon cleansing results with less frequent adverse events, nausea, vomiting, abdominal pain, and sleep disturbances and a higher degree of willingness to repeat the same bowel preparation than PEG. However, mucosal inflammation may be more frequent with magnesium-based bowel preparations.22-24 Compared with PEG, PEGA provides similar colon cleanliness for the entire colon with a higher proportion of patients being willing to repeat the same bowel preparation.25-27 However, PEG tends to produce more satisfactory cleanliness in the right colon than PEGA.27-29

While no statistically significant differences between PEG and oral sodium phosphate (OSP) for overall colon cleansing have been reported, the routine use of OSP for bowel preparation should be avoided because of safety concerns.30,31 Although a meta-analysis found no statistically significant association between OSP and kidney injury, 171 cases of renal failure were reported between 2006 and 2007 with the use of OSP. Only 10 were identified with PEG.32,33 Furthermore, an Iceland study estimated that the risk of biopsy-proven acute phosphate nephropathy was approximately 1 per 1,000 OSP doses.34 Other complications of OSP are hyperphosphatemia, hypocalcemia, hypokalemia, hypernatremia, and hyponatremia.33 To prevent complications associated with OSP, physicians need to be aware of the contraindications of OSP and also the risk factors for acute phosphate nephropathy, and they must carefully screen patients before prescribing OSP. The absolute contraindications to OSP are pregnancy, age <18 years, stage 3 to 5 chronic kidney disease (glomerular filtration rate [GFR] <60 mL/min/1.73 m2), inability to maintain adequate fluid intake, pre-existing electrolyte disturbances, ascites, symptomatic congestive heart failure, and recent (within <6 months) symptomatic ischemic heart disease (unstable angina or myocardial infarction). Relative contraindications include active inflammatory bowel disease, parathyroidectomy, and delayed bowel transit.35 The risk factors for acute phosphate nephropathy associated with OSP are age >55 years, hypovolemia, baseline kidney disease, bowel obstruction, active colitis, and the intake of drugs that affect renal perfusion or function, such as diuretics, angiotensin-converting enzyme inhibitors (ACEI), angiotensin receptor blockers (ARB), and nonsteroidal anti-inflammatory drugs (NSAIDs).36 Minimizing the dose of OSP and requiring a minimum of 12 hours between the administration of the two OSP doses are essential.37 Modification of the standard dose of OSP 45/45 mL 9 to 12 hours apart to 45/30 mL should be considered; each method provides equally effective bowel cleansing with significantly lower serum phosphate levels. In addition, increasing the interval to 24 hours reduces the incidence of significant hyperphosphatemia (>2.1 mmol/L) without compromising its efficacy.38 Therefore, OSP should be used in limited cases that are not met by other bowel preparation agents in patients without risks of OSP-associated side effects.

SPECIFIC CONSIDERATIONS

Previous failure of adequate bowel preparation

Inadequate bowel preparation has been reported in up to one third of colonoscopies. Therefore, identification of its risk factors could be very important. However, a model based on risk factors, such as male gender, inpatient status, and older age, correctly predicted inadequate bowel preparation in only 60% of patients.39 An intensive bowel preparation should be prescribed for patients scheduled for a colonoscopy who have experienced previous inadequate bowel preparation, which might be a predictor of inadequate bowel preparation.40,41

Pregnancy and breastfeeding

PEG is considered safe during pregnancy.42 During and after the bowel preparation, it may be advisable to pause breastfeeding.

In conditions of suspicious inflammatory bowel disease

With OSP and SPMC, preparation-induced mucosal inflammation has been reported 10 times more frequently than with PEG.24 Erosion, aphthoid lesions, and ulcers are often multiple and occur primarily in the distal sigmoid colon and rectum.43

Lower gastrointestinal bleeding

In emergent colonoscopy to evaluate a patient with lower gastrointestinal bleeding, PEG is advisable. Urgent colonoscopy following a rapid colon preparation performed within 24 hours of admission is safe and may facilitate the detection and management of bleeding lesions. In a report regarding patients with acute lower intestinal bleeding, the cecal intubation rate was 41% without full bowel preparation compared with 74% in the PEG group.44,45

Situations bring out hypovolemia

Comorbidities bring out hypovolemia such as diarrhea, vomiting, dysphagia, hyperglycemia, and diuretics use, which should be evaluated before the administration of bowel preparation agents. Isotonic electrolyte-mixed fluid is advisable for intravenous fluid replacement.46 Fluid intake should continue until 2 hours before the colonoscopy, and isotonic electrolyte oral rehydration solutions may be of more benefit than plain water.47 With SPMC or OSP, isotonic electrolyte oral rehydration solutions should be taken to prevent hyponatremia rather than plain water. Some patients receiving PEG may achieve adequate bowel preparation without consuming the full 4 L. Therefore, patients should discontinue the oral bowel-cleansing agent if their diarrhea becomes clear.48

Chronic kidney disease

Information about renal function in patients is important in order to identify an appropriate bowel preparation agent. The most important factor in acute phosphate nephropathy after OSP use is pre-existing chronic kidney disease. Kidney function should be evaluated in patients with any of the known predisposing conditions of kidney disease. With chronic kidney disease, OSP should be avoided. For early chronic kidney disease, PEG or SPMC are acceptable. Cases with late chronic kidney disease without dialysis should be prescribed with PEG or PEGA. SPMC have a risk of hypermagnesemia in patients with kidney disease without dialysis. Thrombosis through arteriovenous fistulae for hemodialysis could be accompanied with dehydration and hypotension. Because PEG may expand intravascular volume, the schedule of dialysis should be adjusted according to the intravascular volume status. In order to preserve the residual renal function, intravascular volume depletion should be avoided in patients with peritoneal dialysis.

Heart failure

PEG is the best oral bowel preparation agent for patients with heart failure. Because heart failure, a risk factor of acute phosphate nephropathy, is accompanied by a reduction in GFR, patients with significant heart failure should not receive OSP.

Liver cirrhosis

Because liver cirrhosis is a risk factor for acute phosphate nephropathy by OSP, PEG is the best oral bowel preparation agent.

Use of ACEI or ARB, diuretics, and NSAID

ACEI or ARB use should be discontinued on the day of administration of oral bowel preparation agents and until 3 days following the colonoscopy. Renal function during ACEI use is prone to aggravate during hypovolemia. ARB intensifies bicarbonaturia by promoting calcium and phosphate precipitation, the risk of acute phosphate nephropathy with OSP. PEG is advisable in patients who use diuretics. In patients taking diuretics, intravascular volume status and electrolyte balance may be imbalanced. Therefore, discontinuation of diuretics should be considered with bowel preparation agent. NSAIDs should be discontinued on the day of administration of oral bowel preparation agents and until 3 days after the colonoscopy.5

CONCLUSIONS

Effective colonoscopy requires an adequate level of cleansing as a basic component. A low-fiber diet is an independent predictor of adequate bowel preparation. Improved bowel cleansing does not result from the routine use of enemas or prokinetics in addition to oral bowel preparation. Generally, a split method of 4 L PEG on the day before and the day of colonoscopy is recommended and valid alternatives are 2 L PEGA or 2 L SPMC. PEG-based bowel preparation is advisable in most situations in terms of safety concerns.

Footnotes

The author has no financial conflicts of interest.

References

  • 1.Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76–79. doi: 10.1067/mge.2003.294. [DOI] [PubMed] [Google Scholar]
  • 2.Froehlich F, Wietlisbach V, Gonvers JJ, Burnand B, Vader JP. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointest Endosc. 2005;61:378–384. doi: 10.1016/s0016-5107(04)02776-2. [DOI] [PubMed] [Google Scholar]
  • 3.Rex DK, Imperiale TF, Latinovich DR, Bratcher LL. Impact of bowel preparation on efficiency and cost of colonoscopy. Am J Gastroenterol. 2002;97:1696–1700. doi: 10.1111/j.1572-0241.2002.05827.x. [DOI] [PubMed] [Google Scholar]
  • 4.Senore C, Ederle A, Fantin A, et al. Acceptability and side-effects of colonoscopy and sigmoidoscopy in a screening setting. J Med Screen. 2011;18:128–134. doi: 10.1258/jms.2011.010135. [DOI] [PubMed] [Google Scholar]
  • 5.Connor A, Tolan D, Hughes S, Carr N, Tomson C. Consensus guidelines for the safe prescription and administration of oral bowel-cleansing agents. Gut. 2012;61:1525–1532. doi: 10.1136/gutjnl-2011-300861. [DOI] [PubMed] [Google Scholar]
  • 6.Wu KL, Rayner CK, Chuah SK, Chiu KW, Lu CC, Chiu YC. Impact of low-residue diet on bowel preparation for colonoscopy. Dis Colon Rectum. 2011;54:107–112. doi: 10.1007/DCR.0b013e3181fb1e52. [DOI] [PubMed] [Google Scholar]
  • 7.Adams WJ, Meagher AP, Lubowski DZ, King DW. Bisacodyl reduces the volume of polyethylene glycol solution required for bowel preparation. Dis Colon Rectum. 1994;37:229–233. doi: 10.1007/BF02048160. [DOI] [PubMed] [Google Scholar]
  • 8.Soweid AM, Kobeissy AA, Jamali FR, et al. A randomized single-blind trial of standard diet versus fiber-free diet with polyethylene glycol electrolyte solution for colonoscopy preparation. Endoscopy. 2010;42:633–638. doi: 10.1055/s-0029-1244236. [DOI] [PubMed] [Google Scholar]
  • 9.Park DI, Park SH, Lee SK, et al. Efficacy of prepackaged, low residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation: a randomized trial. J Gastroenterol Hepatol. 2009;24:988–991. doi: 10.1111/j.1440-1746.2009.05860.x. [DOI] [PubMed] [Google Scholar]
  • 10.Lever EL, Walter MH, Condon SC, et al. Addition of enemas to oral lavage preparation for colonoscopy is not necessary. Gastrointest Endosc. 1992;38:369–372. doi: 10.1016/s0016-5107(92)70435-0. [DOI] [PubMed] [Google Scholar]
  • 11.Børkje B, Pedersen R, Lund GM, Enehaug JS, Berstad A. Effectiveness and acceptability of three bowel cleansing regimens. Scand J Gastroenterol. 1991;26:162–166. doi: 10.3109/00365529109025026. [DOI] [PubMed] [Google Scholar]
  • 12.Golub RW, Kerner BA, Wise WE, Jr, et al. Colonoscopic bowel preparations: which one? A blinded, prospective, randomized trial. Dis Colon Rectum. 1995;38:594–599. doi: 10.1007/BF02054117. [DOI] [PubMed] [Google Scholar]
  • 13.Tasci I, Altinli E, Sirin F. Bowel cleansing for diagnostic colonoscopy: which method is preferable? Istanbul experience. Tech Coloproctol. 2003;7:18–21. doi: 10.1007/s101510300003. [DOI] [PubMed] [Google Scholar]
  • 14.Wu L, Cao Y, Liao C, Huang J, Gao F. Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility. Scand J Gastroenterol. 2011;46:227–235. doi: 10.3109/00365521.2010.525714. [DOI] [PubMed] [Google Scholar]
  • 15.Kilgore TW, Abdinoor AA, Szary NM, et al. Bowel preparation with split-dose polyethylene glycol before colonoscopy: a meta-analysis of randomized controlled trials. Gastrointest Endosc. 2011;73:1240–1245. doi: 10.1016/j.gie.2011.02.007. [DOI] [PubMed] [Google Scholar]
  • 16.Church JM. Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy: timing is the key. Dis Colon Rectum. 1998;41:1223–1225. doi: 10.1007/BF02258217. [DOI] [PubMed] [Google Scholar]
  • 17.Varughese S, Kumar AR, George A, Castro FJ. Morning-only one-gallon polyethylene glycol improves bowel cleansing for afternoon colonoscopies: a randomized endoscopist-blinded prospective study. Am J Gastroenterol. 2010;105:2368–2374. doi: 10.1038/ajg.2010.271. [DOI] [PubMed] [Google Scholar]
  • 18.Longcroft-Wheaton G, Bhandari P. Same-day bowel cleansing regimen is superior to a split-dose regimen over 2 days for afternoon colonoscopy: results from a large prospective series. J Clin Gastroenterol. 2012;46:57–61. doi: 10.1097/MCG.0b013e318233a986. [DOI] [PubMed] [Google Scholar]
  • 19.Marmo R, Rotondano G, Riccio G, et al. Effective bowel cleansing before colonoscopy: a randomized study of split-dosage versus non-split dosage regimens of high-volume versus low-volume polyethylene glycol solutions. Gastrointest Endosc. 2010;72:313–320. doi: 10.1016/j.gie.2010.02.048. [DOI] [PubMed] [Google Scholar]
  • 20.Eun CS, Han DS, Hyun YS, et al. The timing of bowel preparation is more important than the timing of colonoscopy in determining the quality of bowel cleansing. Dig Dis Sci. 2011;56:539–544. doi: 10.1007/s10620-010-1457-1. [DOI] [PubMed] [Google Scholar]
  • 21.Siddiqui AA, Yang K, Spechler SJ, et al. Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality. Gastrointest Endosc. 2009;69(3 Pt 2):700–706. doi: 10.1016/j.gie.2008.09.047. [DOI] [PubMed] [Google Scholar]
  • 22.Tan JJ, Tjandra JJ. Which is the optimal bowel preparation for colonoscopy: a meta-analysis. Colorectal Dis. 2006;8:247–258. doi: 10.1111/j.1463-1318.2006.00970.x. [DOI] [PubMed] [Google Scholar]
  • 23.Worthington J, Thyssen M, Chapman G, Chapman R, Geraint M. A randomised controlled trial of a new 2 litre polyethylene glycol solution versus sodium picosulphate+magnesium citrate solution for bowel cleansing prior to colonoscopy. Curr Med Res Opin. 2008;24:481–488. doi: 10.1185/030079908x260844. [DOI] [PubMed] [Google Scholar]
  • 24.Lawrance IC, Willert RP, Murray K. Bowel cleansing for colonoscopy: prospective randomized assessment of efficacy and of induced mucosal abnormality with three preparation agents. Endoscopy. 2011;43:412–418. doi: 10.1055/s-0030-1256193. [DOI] [PubMed] [Google Scholar]
  • 25.Jansen SV, Goedhard JG, Winkens B, van Deursen CT. Preparation before colonoscopy: a randomized controlled trial comparing different regimes. Eur J Gastroenterol Hepatol. 2011;23:897–902. doi: 10.1097/MEG.0b013e32834a3444. [DOI] [PubMed] [Google Scholar]
  • 26.Pontone S, Angelini R, Standoli M, et al. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol. 2011;17:4689–4695. doi: 10.3748/wjg.v17.i42.4689. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol. 2010;45:1380–1386. doi: 10.3109/00365521003734158. [DOI] [PubMed] [Google Scholar]
  • 28.Singh H, Turner D, Xue L, Targownik LE, Bernstein CN. Risk of developing colorectal cancer following a negative colonoscopy examination: evidence for a 10-year interval between colonoscopies. JAMA. 2006;295:2366–2373. doi: 10.1001/jama.295.20.2366. [DOI] [PubMed] [Google Scholar]
  • 29.Baxter NN, Goldwasser MA, Paszat LF, Saskin R, Urbach DR, Rabeneck L. Association of colonoscopy and death from colorectal cancer. Ann Intern Med. 2009;150:1–8. doi: 10.7326/0003-4819-150-1-200901060-00306. [DOI] [PubMed] [Google Scholar]
  • 30.Belsey J, Epstein O, Heresbach D. Systematic review: oral bowel preparation for colonoscopy. Aliment Pharmacol Ther. 2007;25:373–384. doi: 10.1111/j.1365-2036.2006.03212.x. [DOI] [PubMed] [Google Scholar]
  • 31.Belsey J, Crosta C, Epstein O, et al. Meta-analysis: the relative efficacy of oral bowel preparations for colonoscopy 1985-2010. Aliment Pharmacol Ther. 2012;35:222–237. doi: 10.1111/j.1365-2036.2011.04927.x. [DOI] [PubMed] [Google Scholar]
  • 32.Brunelli SM. Association between oral sodium phosphate bowel preparations and kidney injury: a systematic review and meta-analysis. Am J Kidney Dis. 2009;53:448–456. doi: 10.1053/j.ajkd.2008.09.022. [DOI] [PubMed] [Google Scholar]
  • 33.Belsey J, Epstein O, Heresbach D. Systematic review: adverse event reports for oral sodium phosphate and polyethylene glycol. Aliment Pharmacol Ther. 2009;29:15–28. doi: 10.1111/j.1365-2036.2008.03837.x. [DOI] [PubMed] [Google Scholar]
  • 34.Pálmadóttir VK, Gudmundsson H, Hardarson S, Arnadóttir M, Magnússon T, Andrésdóttir MB. Incidence and outcome of acute phosphate nephropathy in Iceland. PLoS One. 2010;5:e13484. doi: 10.1371/journal.pone.0013484. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Hookey LC, Vanner S. Recognizing the clinical contraindications to the use of oral sodium phosphate for colon cleansing: a case study. Can J Gastroenterol. 2004;18:455–458. doi: 10.1155/2004/787515. [DOI] [PubMed] [Google Scholar]
  • 36.Wexner SD, Beck DE, Baron TH, et al. A consensus document on bowel preparation before colonoscopy: prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) Gastrointest Endosc. 2006;63:894–909. doi: 10.1016/j.gie.2006.03.918. [DOI] [PubMed] [Google Scholar]
  • 37.Markowitz GS, Perazella MA. Acute phosphate nephropathy. Kidney Int. 2009;76:1027–1034. doi: 10.1038/ki.2009.308. [DOI] [PubMed] [Google Scholar]
  • 38.Rostom A, Jolicoeur E, Dubé C, et al. A randomized prospective trial comparing different regimens of oral sodium phosphate and polyethylene glycol-based lavage solution in the preparation of patients for colonoscopy. Gastrointest Endosc. 2006;64:544–552. doi: 10.1016/j.gie.2005.09.030. [DOI] [PubMed] [Google Scholar]
  • 39.Hassan C, Fuccio L, Bruno M, et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012;10:501–506. doi: 10.1016/j.cgh.2011.12.037. [DOI] [PubMed] [Google Scholar]
  • 40.Ben-Horin S, Bar-Meir S, Avidan B. The outcome of a second preparation for colonoscopy after preparation failure in the first procedure. Gastrointest Endosc. 2009;69(3 Pt 2):626–630. doi: 10.1016/j.gie.2008.08.027. [DOI] [PubMed] [Google Scholar]
  • 41.Ibáñez M, Parra-Blanco A, Zaballa P, et al. Usefulness of an intensive bowel cleansing strategy for repeat colonoscopy after preparation failure. Dis Colon Rectum. 2011;54:1578–1584. doi: 10.1097/DCR.0b013e31823434c8. [DOI] [PubMed] [Google Scholar]
  • 42.Briggs GG, Freeman RK, Yaffe SJ. Drugs in Pregnancy and Lactation. 9th ed. Philadelphia: Lippincott Williams & Wilkins; 2011. [Google Scholar]
  • 43.Rejchrt S, Bures J, Siroký M, Kopácová M, Slezák L, Langr F. A prospective, observational study of colonic mucosal abnormalities associated with orally administered sodium phosphate for colon cleansing before colonoscopy. Gastrointest Endosc. 2004;59:651–654. doi: 10.1016/s0016-5107(04)00158-0. [DOI] [PubMed] [Google Scholar]
  • 44.Colacchio TA, Forde KA, Patsos TJ, Nunez D. Impact of modern diagnostic methods on the management of active rectal bleeding. Ten year experience. Am J Surg. 1982;143:607–610. doi: 10.1016/0002-9610(82)90175-1. [DOI] [PubMed] [Google Scholar]
  • 45.Saito K, Inamori M, Sekino Y, et al. Management of acute lower intestinal bleeding: what bowel preparation should be required for urgent colonoscopy? Hepatogastroenterology. 2009;56:1331–1334. [PubMed] [Google Scholar]
  • 46.Powell-Tuck J, Gosling P, Lobo DN, et al. British Consensus Guidelines on intravenous fluid therapy for adult surgical patients [Internet] Petersfield: The Renal Association; 2009. [cited 2009 Aug 10]. Available from: http://www.renal.org/pages/media/Guidelines/GIFTASUP%20FINAL_31-10-08.pdf. [Google Scholar]
  • 47.Tjandra JJ, Tagkalidis P. Carbohydrate-electrolyte (E-Lyte) solution enhances bowel preparation with oral fleet phospho-soda. Dis Colon Rectum. 2004;47:1181–1186. doi: 10.1007/s10350-004-0559-2. [DOI] [PubMed] [Google Scholar]
  • 48.Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol. 2006;20:101–105. doi: 10.1155/2006/621367. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Clinical Endoscopy are provided here courtesy of Korean Society of Gastrointestinal Endoscopy