Abstract
Background
The purpose of this study was to demonstrate how magnetic resonance imaging (MRI) patient position protocols influence registration quality in patients with oropharyngeal cancer undergoing radical radiotherapy and the consequences for gross tumour volume (GTV) definition and radiotherapy planning.
Methods and materials
Twenty-two oropharyngeal patients underwent a computed tomography (CT), a diagnostic MRI (MRID) and an MRI in the radiotherapy position within an immobilization mask (MRIRT). Clinicians delineated the GTV on the CT viewing the MRID separately (GTVC); on the CT registered to MRID (GTVD) and on the CT registered to MRIRT (GTVRT). Planning target volumes (PTVs) were denoted similarly. Registration quality was assessed by measuring disparity between structures in the three set-ups. Volumetric modulated arc therapy (VMAT) radiotherapy planning was performed for PTVC, PTVD and PTVRT. To determine the dose received by the reference PTVRT, we optimized for PTVC and PTVD while calculating the dose to PTVRT. Statistical significance was determined using the two-tailed Mann–Whitney or two-tailed paired student t-tests.
Results
A significant improvement in registration accuracy was found between CT and MRIRT versus the MRID measuring distances from the centre of structures (geometric mean error of 2.2 mm versus 6.6 mm). The mean GTVC (44.1 cm3) was significantly larger than GTVD (33.7 cm3, p value = 0.027) or GTVRT (30.5 cm3, p value = 0.014). When optimizing the VMAT plans for PTVC and investigating the mean dose to PTVRT neither the dose to 99% (58.8%) nor 95% of the PTV (84.7%) were found to meet the required clinical dose constraints of 90% and 95% respectively. Similarly, when optimizing for PTVD the mean dose to PTVRT did not meet clinical dose constraints for 99% (14.9%) nor 95% of the PTV (66.2%). Only by optimizing for PTVRT were all clinical dose constraints achieved.
Conclusions
When oropharyngeal patients MRI scans are performed in the radiotherapy position there are significant improvements in CT-MR image registration, target definition and PTV dose coverage.
Keywords: MRI, CT, Oropharyngeal, Radiotherapy, Image registration, Patient setup
Background
With intensity modulated radiotherapy and volumetric modulated arc therapy (VMAT), it is possible to deliver high doses of radiation to irregular target volumes whilst sparing normal tissue, which can result in reduced severity of radiation toxicities [1]. Increased dose delivery and dose conformity has led to a greater significance on the accurate localization of the gross tumour volume (GTV) and neighbouring structures.
In radiotherapy (RT) planning, computed tomography (CT) remains the first choice since it provides accurate dosimetric information. Imaging modalities such as magnetic resonance imaging (MRI) and positron emission tomography (PET) may present advantages compared to CT in terms of target definition. In particular, MRI offers improved soft tissue contrast [2,3] and reduced artefacts from dental amalgam; hence, MRI is the imaging modality of choice for oropharyngeal cancers [4]. MRI improves target definition for patients with head and neck [5-7], prostate [8,9] and brain [10,11] cancer.
Challenges with MRI in clinical practice include: geometric distortion [12,13]; motion related artefacts [14] and magnetic susceptibility [15,16]. Patient positioning must also be considered, since differing patient set-ups between modalities can result in uncertainties in the location and magnitude of the GTV and thus the dose received by the patient [17].
Patients receiving RT to the brain can undergo an MRI in the RT position within an immobilization mask, without loss of image quality over standard imaging methods [18]. An approximate image registration uncertainty of 2 mm occurs when registering CT image sets in the treatment position to a diagnostic MRI for patients with brain cancer [19] and therefore many RT centres routinely register these scans for RT planning. While it could be anticipated that imaging patients with oropharyngeal cancer in the treatment position would result in improved registration and target volume definition, to our knowledge there is no published evidence to suggest that using the diagnostic MRI provides results to the contrary. In addition, no publications have analyzed the dosimetric consequences of patient positioning during MRI scan acquisition.
The purpose of this study was to compare an MRI acquired with a diagnostic patient position on a standard MRI table to an MRI acquired on a flat table with custom immobilization and to determine how this affects CT-MRI registration, GTV definition, the resulting VMAT RT plans and the magnitude of the associated geometric and dosimetric errors. The results obtained would then provide an answer to whether it was necessary to obtain a planning MRI scan for patients with oropharyngeal cancer in the RT treatment position using an immobilization mask or whether a diagnostic patient position protocol would suffice.
Methods
Patient group and study overview
Twenty two patients with oropharyngeal cancer (age 37–72), being worked up for radical RT (patients being treated with curative intent), were identified for the study, regardless of tumour or nodal stage. The study protocol was approved by Local Ethics Committee (West of Scotland Research Ethics Service, Western Infirmary, Glasgow G11 6NT, Scotland, UK) and informed written consent was obtained from all patients. Registration quality assessment was conducted on all patients, however, in three patients a GTV evaluation was not possible, since two patients had undergone primary surgical resection and another had received induction chemotherapy, resulting in complete response.
Patients underwent a CT planning scan, and two MRI scans (patients scanned between February 2010 and January 2012; median time between CT and MRI scans = 5 days, range = 0 to 21 days). The first MRI scan was obtained with the patient in the standard diagnostic position (denoted as MRID) and the second with the patient in an immobilization mask in the RT position (MRIRT). Both MRI scans were registered separately with the CT planning scan as shown in Figure 1. The GTV was delineated on the CT images by trained Consultant Radiation Oncologists using the treatment planning system, with the aid of viewing MRID on a separate console. This patient position protocol is denoted as PPC. This is the current standard practice at out centre, and would be considered standard practice in the majority of institutions in this country. For the purposes of this study, the GTV was delineated using two other patient set-ups. Firstly, the GTV was delineated on the MRID registered to the CT datasets. This patient position protocol is denoted as PPD. The GTV was also delineated on the MRIRT registered to the CT image sets, denoted as PPRT.
CT and MRI scanning protocol
Patients were scanned on a GE Light-speed RT 16 slice CT scanner (GE Healthcare, WI, USA), using the current clinical scanning protocol, and immobilized within a full face and neck five point fixation thermoplastic beam directional shell (BDS) with appropriate head rest (CIVCO Medical Solutions, IA, USA). The scan extent was from superior orbital ridge to carina. A helical scan was acquired with a detector configuration of 16 × 1.25, pitch 0.938, matrix 512 × 512 and speed 18.75 mm/rot with a slice thickness of 2.5 mm.
Patients underwent MRI scans in two different positions during the same scan session. For the MRIRT scan, patients were positioned on a flat MRI Oncology Table (GE Healthcare, WI, USA), within a BDS, with a 4-channel flexible surface cardiac coil positioned laterally over the patient’s neck (Figure 2). The same scan extent as the CT scan was employed and the imaging parameters, chosen in accordance with local protocol, are presented in Table 1.
Table 1.
Scan type | FOV* (mm) | Slice thick (mm) | Spacing (mm) | TE† (ms) | TR†† (ms) | Bandwidth (± kHz) | Matrix size |
---|---|---|---|---|---|---|---|
2D Driven-equilibrium FSE (T2-weighted) |
400 |
2.5 |
0 |
94 |
2620 |
63 |
512 × 256 |
3D Spoiled gradient echo (T1-weighted post-contrast) | 400 | 2.5 | 0 | 2 | 15 | 50 | 256 × 256 |
* Field of view.
† Echo time.
†† Repetition time.
The scan was repeated for the MRID on a standard curved diagnostic table without BDS using a 16-channel head, neck and spine coil, with the CT scan extent. The 16-channel head, neck and spine coil was not used for the MRIRT scan since it is not compatible with the BDS. A previous investigation using test objects has shown the image quality obtained using the 4-channel cardiac coil is of diagnostic quality [18].
Image registration
The treatment planning system (Eclipse, Varian Medical Systems, Inc. CA, USA, version 10.0.39) was used to register the MRIRT and MRID T1 and T2-weighted scans to the CT data. This software enabled fully automated, mutual-information based rigid registration to be performed. While deformable registration is available for Eclipse, it does not allow inter-modality registration. Since commercial inter-modality deformable image registration is generally not available, nor employed clinically in our centre at present, this was not subject to further investigation. The volume over which the registration was performed was centred over the oropharyngeal region and chosen to include as much information for the registration algorithm as possible [6]. Fully automated registration was used without manual adjustment since, for this site, satisfactory registration for both target and nodes is not always achievable and would introduce subjective errors.
To quantitatively assess the quality of registration the orbits and the odontoid process were outlined on the CT and T1-weighted MR image sets. These three structures were delineated on the CT, for each patient, and then repeated on the MR datasets registered to the CT.
Two metrics determined the quality of registration. Firstly, the distance between the centre of the orbits and odontoid process drawn on the CT and the MRI datasets was calculated using the coordinate location of the centre of the structures determined by the treatment planning software. The geometric mean was calculated to ensure normality of the data. Secondly, the quality of registration was assessed by measuring the spatial overlap of these structures drawn on CT and MRI. The spatial overlap was assessed by calculating the Dice coefficient (spatial overlap) for each structure, which is given by,
where CT ∩ MRI is the volume of intersection between the CT and MRI structures. The value of the spatial overlap can range from zero, which indicates no spatial overlap between the CT and MRI volumes, to one, which indicates complete overlap [20]. Since structures outlined on CT and MRI may differ, even with perfect registration, a spatial overlap of one may not be achieved in practice, but will still be dependent on different patient set-up and registration quality.
Gross tumour volume, lower risk clinical target volume and organ at risk delineation
Three Oncologists were assigned five patients each and a fourth was assigned four patients. The Oncologists delineated the GTV on their patients using the three set-ups PPC, PPD and PPRT, which in this study are referred to as GTVC, GTVD and GTVRT respectively. Anonymized information sheets, containing the patient’s clinical history and radiology report, were available to the Oncologists. The clinicians generally utilized the T2-weighted MR datasets while contouring the GTV, although T1-weighted images were also referenced. A period of at least a week was given between delineations of the GTV for the same patient using a different imaging protocol and the Oncologists were blinded to previous delineations. Changes in the magnitude of the GTV were assessed. Contouring was also performed on the lower risk clinical target volume (CTV LR) of the nodal areas at risk of microscopic involvement for a randomly selected cohort of ten patients, in each of the set-ups. Nodal delineation was performed according to international consensus guidelines [21]. For these patients, the organs at risk (OARs), which included the left and right parotids, larynx, spinal cord and the brainstem, were also contoured.
The GTV and CTV LR were expanded to obtain planning target volumes, (PTV) and lower risk planning target volumes (PTV LR) respectively. To create the clinical target volume (CTV) the GTV was expanded by 1 cm isotropically, removing any overlap with bone or air cavities. The CTV was then enlarged by 3 mm isotropically and cropped from the external outline of the body to create the PTV. It is necessary to crop the PTV from the body outline to assist in the VMAT optimization process. The PTVs were generated from the GTVs using the three set-ups PPC, PPD and PPRT, which are denoted as PTVC, PTVD and PTVRT respectively. Similarly, to generate the PTV LR the CTV LR was expanded by 3 mm isotropically and cropped by an appropriate margin from the body outline. Target volumes and OARs were generated in accordance with local protocol.
Dose analysis
VMAT plans were calculated for the ten patients for whom the GTV, CTV LR and OARs were contoured, to determine the impact that changes in target volume definition have on RT planning. The VMAT plans were calculated in accordance with our centre’s clinical dose constraints using the Anisotropic Analytical Algorithm and Progressive Resolution Optimizer VMAT algorithm in Eclipse (Varian Medical Systems, Inc, CA, USA) version 10.0.28. A VMAT plan was calculated for PTVC, PTVD and PTVRT. Dose volume histograms (DVHs) were generated for PTVC, PTVD and PTVRT. A mean DVH for all ten patients was then calculated for PPC, PPD and PPRT. These results are presented using our centre’s dose constraint protocol i.e. D99 > 90%, D95 > 95%, D5 < 105% and D2 < 107%, where D99 > 90% means 99% of the total PTV volume should receive a dose > 90% of the prescribed dose. The other dose constraints are defined similarly.
Of particular interest in this study was to establish the quality of the RT plan for PPC and PPD with reference to PPRT, since our working hypothesis postulates that the optimum target volume definition is achieved with PPRT. To achieve this we optimized for PTVC and PTVD but investigated the dose coverage of PTVRT at D99 > 90%, D95 > 95%, D5 < 105% and D2 < 107%.
A quantitative comparison of the homogeneity of the dose to the PTV was completed using the sigma index. The sigma index was compared individually for PTVC, PTVD and PTVRT as well as for PTVC, PTVD with reference to PTVRT. The sigma index is equal to the standard deviation of the dose throughout the PTV, calculated on a voxel by voxel basis [22], thus the higher the sigma index, the greater the dose inhomogeneity.
Finally, the dose to the OARs was assessed by evaluating the mean and maximum dose received using PPC, PPD and PPRT.
Two-tailed paired student t-tests were performed to examine the statistical differences of the registration quality and dosimetric indices, except for the geometric mean distance from the centre of structures in CT and MRI where two-tailed Mann–Whitney tests were performed. A Mann–Whitney test was used to assess the geometric mean distance from the centre of the structures because the data was not normally distributed. The null hypothesis was rejected when the p value was less than 0.05.
Results
There was a reduction in the geometric mean distance from the centre of the orbits and odontoid process delineated on the CT and MRIRT to that delineated on the CT to MRID volumes (Figure 3) and this was significant (p value < 0.001) for each structure. Narrower error bars exist for the CT registered to the MRIRT versus the MRID, which strongly implies that the patients are positioned more closely to their CT set-up in the BDS than when using the ordinary diagnostic set-up. No correlation was found between the time from the CT and MRI scan in days and the mean registration error for either MRID (R2 = 0.06) or MRIRT (R2 = 0.02).
An improvement in the mean spatial overlap for the orbits and odontoid process was observed between CT and the CT-MRIRT over the CT to CT-MRID data sets as shown in Table 2. Analyzing the difference between the spatial overlap of CT to CT-MRID versus CT to CT-MRIRT was shown to have a p value < 0.001 for both orbits and odontoid process (Table 2). The volume of the three structures delineated on CT was larger than those delineated on MRI, however, their mean difference was within one standard deviation. Therefore, the spatial overlap is expected to give a good measure of the quality of registration.
Table 2.
CT-MRID* mean spatial overlap | CT-MRIRT† mean spatial overlap | p value | |
---|---|---|---|
Left orbit |
0.49 |
0.81 |
< 0.001 |
Right orbit |
0.48 |
0.81 |
< 0.001 |
Odontoid process | 0.37 | 0.67 | < 0.001 |
* CT registered with diagnostic MRI.
† CT registered with the radiotherapy positioned MRI.
The mean GTVC was significantly larger than the GTVD or GTVRT as shown in Table 3. The p values in Table 3 refer to the differences in the magnitude of the GTVC and the other two GTVs. There was no significant difference between GTVD and GTVRT (p value = 0.14).
Table 3.
Mean GTVC† | Mean GTVD†† (p value) | Mean GTVRT# (p value) |
---|---|---|
44.1 | 33.7 (0.027) | 30.5 (0.014) |
The p value relates to differences in the magnitude of GTVC and the other two GTVs.
* Gross tumour volume.
† GTV delineated on CT with diagnostic MRI scan viewed separately.
†† GTV delineated using the CT registered with diagnostic MRI.
# GTV delineated using the CT registered with radiotherapy positioned MRI.
Clinical dose constraints were met for the mean DVHs of PTVC, PTVD and PTVRT (columns 3–5 of Figure 4(a)), which validates the planning methodology in this study. When optimizing the RT plan for PTVC, or repeating the optimization process for PTVD, the dose to PTVRT shows that neither the D99 nor the D95 dose constraints are met for the mean DVHs of PPC or PPD (the last 2 columns of Figure 4(a) and (b)). For example, for D99 mean dose to the PTV for PTVD: PTVRT is 14.9% rather than the 90% required. Conformity to dose constraints is poorer for PTVD: PTVRT compared to PTVC: PTVRT (Figure 4(b)). Only by using PPRT can all dose constraints be achieved for PTVRT.
The justification for choosing only ten patients to perform the dose analysis was that none of the ten patients met the 90% dose constraint for PTVC: PTVRT and PTVD: PTVRT and only one of the ten patients met the 95% dose constraint for both PTVC: PTVRT and PTVD: PTVRT. This relates to a 95% confidence interval of 0.0% to 30.9% and 0.3% to 44.5% respectively. These confidence intervals demonstrate that no further cases are statistically necessary in the analysis.
Figure 5 demonstrates for a typical patient the PTVRT and the dose distributions optimized for PTVC (left) and PTVD (right). This figure shows that the 95% isodose line does not cover PTVRT entirely with a posterior proportion of the PTV receiving a dose less than 95% of the prescribed dose. Figure 5 is in agreement with the results of Figure 4 which shows that when optimizing for PTVC or PTVD not all the dose constraints are met for PTVRT.
The mean sigma indices are shown in Table 4. In the first three columns of Table 4 the sigma indices are within 3.3% again validating the planning methodology in this study. The dose homogeneity becomes considerably poorer for PTVC: PTVRT and PTVD: PTVRT at 7.3% and 9.1% respectively. A statistically significant difference between the sigma indices was found between PTVC: PTVC and PTVC: PTVRT (p value = 0.004) and between PTVD: PTVD and PTVD: PTVRT (p value = 0.008). The mean sigma index for PTVD: PTVRT is poorer than for PTVC: PTVRT in agreement with the results of Figure 4(a).
Table 4.
PTVC: PTVC* | PTVD PTVD† | PTVRT: PTVRT†† | PTVC: PTVRT | PTVD: PTVRT | |
---|---|---|---|---|---|
Mean sigma index (%) | 3.0 | 3.1 | 3.3 | 7.3 | 9.1 |
PTV left of the colon indicates the PTV for which the VMAT plan was optimized and right of the colon the PTV under examination.
* PTV delineated using the CT with diagnostic MRI viewed separately.
† PTV delineated on the CT registered with diagnostic MRI.
†† PTV delineated on the CT registered with radiotherapy positioned MRI.
Results for parotid and larynx OAR dose analyses are presented in Table 5. In situations where there was overlap between a parotid and PTV, it was considered that dose sparing to that parotid was not possible without compromising PTV dose; hence it was excluded from the analysis. The results demonstrate that in planning PTVC, PTVD and PTVRT, in all 10 patients the mean dose to the parotid was < 2400 cGy which met clinical dose constraints. However, when RT plans were optimized for PTVC and PTVD and the dose to the parotid for PPRT were analysed (PTVC: PTVRT and PTVD: PTVRT) in 5 out of 10 patients the parotid dose exceeded the tolerance. For the larynx, the tolerance of 4000 cGy was exceeded in 4 out of 10 for PPC, 3 out of 10 for PPD and 1 out of 10 patients for PPRT. However, as with the parotid, when RT plans were optimized for PTVC and PTVD and the dose to the larynx for PPRT were analysed there were more instances of unmet dose constraints (5 out of 10 patients for both PTVC: PTVRT and PTVD: PTVRT).
Table 5.
(a) |
|
||||
---|---|---|---|---|---|
Parotid mean dose (cGy) |
|||||
Mean dose constraint 2400 cGy | |||||
PPC: PPC* | PPD: PPD† | PPRT: PPRT†† | PPC: PPRT | PPD: PPRT | |
Mean |
2179.6 |
1965.5 |
1820.3 |
2233.8 |
1992.4 |
Number of patients which exceed the dose constraint |
0 |
0 |
0 |
5 |
5 |
(b) |
|
|
|
|
|
|
Larynx mean dose (cGy) |
||||
Mean dose constraint 4000 cGy | |||||
PPC: PPC |
PPD: PPD |
PPRT: PPRT |
PPC: PPRT |
PPD: PPRT |
|
Mean |
3979.6 |
3892.3 |
3613.2 |
4108.8 |
4020.6 |
Number of patients which exceed the dose constraint | 4 | 3 | 1 | 5 | 5 |
Where there was overlap between a parotid and the PTV the parotid dose was not included in the mean parotid dose. PP left of the colon indicates the patient position protocol for which the VMAT plan was optimized and right of the colon indicated the patient position protocol under examination.
* Patient position protocol: CT and diagnostic MRI scan viewed separately.
† Patient position protocol: CT registered with the diagnostic MRI.
†† Patient position protocol: CT registered with radiotherapy positioned MRI.
When the mean dose to the parotid and larynx for all 10 patients was calculated, an incrementally smaller value was seen for PTVC, PTVD and PTVRT (first 3 columns of Table 5), which can be explained by the decrease in the magnitude of the GTV. Dose to the spinal cord and brainstem were also calculated but were not found to exceed clinically relevant tolerances for any of the patient position protocols.
Discussion
Advanced imaging techniques have been shown to improve tumour and nodal staging [23] and the benefits of integrating MRI are well known [5-7,23,24]. While the advantages in positioning patients in a similar way to their CT planning scan when acquiring MR images are also known [6,17,23], this is the first study to compare the CT-MRI registration accuracy and dosimetric effects of a diagnostic versus RT positioned MRI scan in patients with oropharyngeal cancer.
During the process of registering CT to MR images, there was improved registration with fewer discrepancies using MRIRT compared to MRID, as demonstrated in Figure 1. In this example, there are registration discrepancies at the body outline and spinal cord for CT-MRID, as indicated by the arrows (Figure 1(a)), but not with MRIRT (Figure 1(b)).
A significant improvement in the registration quality of CT to MRIRT versus the MRID was demonstrated by a reduction in the geometric mean distance from the centre of the orbits and odontoid process delineated on CT and the MRIRT and an increase in the spatial overlap of these structures. These results show that patient setup significantly influences CT-MRI registration accuracy. With increased interest in the use of dose escalation and dose painting techniques within RT planning the importance of improved image registration becomes ever more relevant.
The significant difference between the magnitude of the GTVC and GTVD and between the GTVC and GTVRT implies that the GTV is significantly smaller when using registered rather than unregistered CT-MR images. This underlines the importance of registering CT to MRI for patients with oropharyngeal cancer, rather than viewing them separately. It also highlights the difficulty in delineating oropharyngeal cancers with CT due to the similarity in Hounsfield Units of tumour and surrounding tissue as well as artefacts caused by dental amalgam. While there was no significant difference between the mean GTVD and GTVRT, there were important differences in the VMAT plans, as discussed below. To achieve the clinical goal of reduced late toxicities and improved tumour control using dose escalation with tighter PTV margins, uncertainties in GTV delineation need to be minimized and our data suggest PPRT offers the optimal of the three set-ups.
The results reveal that there are potentially clinically relevant improvements to the quality of the VMAT plans when using PPRT rather than PPC or PPD. This is demonstrated by the PTV dose coverage, PTV dose homogeneity and instances of unmet dose constraints by the OARs. Due to improved registration accuracy and MRI being the recommended imaging modality for soft tissue oropharyngeal cancers [4], it may be assumed that PTVRT would be the reference PTV. To determine the dose received by the reference, PTVRT, we optimized for PTVC and PTVD while calculating the dose to PTVRT. When optimizing for PTVRT it was shown that the mean DVH for PTVD had poorer dose coverage than PTVC (Figure 4). Despite the magnitude of the mean GTVRT and GTVD being similar there may be differences in the shape and location of the GTV using these patient set-ups which would result in the DVHs of Figure 4. Neither the PPC nor the PPD VMAT plans were able to meet the clinical dose constraints of D99 and D95 for the reference, PTVRT. Furthermore, it has been argued that tumour control probability can be considerably compromised by an inhomogeneous dose to the PTV [25]. It is therefore suboptimal to use PPC or PPD rather than PPRT for RT planning of patients with oropharyngeal cancer.
Obtaining a further MRI in the RT position, rather than using the original diagnostic MRI, may place greater demands on increasingly stretched healthcare resources. However, this must be weighed against the potential advantages of improved image registration and, by consequence, superior target volume definition and dose coverage of the PTV, as these results have demonstrated. Our study suggests further research, particularly in correlating dosimetric investigations with clinical outcome data, would be warranted.
Conclusions
When MRI scans are performed in the RT position, as opposed to using diagnostic MR images not obtained in RT position, there are significant improvements in the quality of CT-MR registration. This study has also shown that RT positioned MRI scans offer improvements in target definition, dose coverage and dose homogeneity, which could have significant implications for tumour control rates. To our knowledge, this is the first study in the literature to confirm these advantages.
Abbreviations
BDS: Beam directional shell; CT: Computed tomography; CTV: Clinical target volume; CTV LR: Lower risk clinical target volume; DVH: Dose volume histograms; GTV: Gross tumour volume; GTVC: Gross tumour volume delineated using PPC; GTVD: Gross tumour volume delineated using PPD; GTVRT: Gross tumour volume delineated using PPRT; MRI: Magnetic resonance imaging; MRID: MRI with the patient in the standard diagnostic position; MRIRT: MRI with the patient in the radiotherapy position in an immobilization mask; OAR: Organ at risk; PET: Positron emission tomography; PPC: Patient position protocol with the CT and MRID on a separate console; PPD: Patient position protocol with the CT and MRID registered; PPRT: Patient position protocol with the CT and MRIRT registered; PTV: Planning target volume; PTV: LR Lower risk planning target volume; PTVC: Planning target volume generated from GTVC; PTVD: Gross tumour volume generated from GTVD; PTVRT: Gross tumour volume generated from GTVRT; RT: Radiotherapy; VMAT: Volumetric modulated arc therapy.
Competing interests
The authors declare they have no competing interests.
Authors’ contributions
SH and JF conceived the study and participated in its design. SH and MT coordinated the study. SH generated the radiotherapy plans and analyzed the data, SH, MMc, JF and MG helped draft the manuscript, LMT delineated the volumes for the radiotherapy plans and the GTVs. DG, AJ, MR and CP delineated the GTVs. All authors read and approved the final manuscript.
Contributor Information
Scott Hanvey, Email: scott.hanvey@ggc.scot.nhs.uk.
Mark McJury, Email: mark.mcjury@ggc.scot.nhs.uk.
Lye Mun Tho, Email: lyetho@gmail.com.
Martin Glegg, Email: martin.glegg@ggc.scot.nhs.uk.
Maureen Thomson, Email: maureen.thomson2@ggc.scot.nhs.uk.
Derek Grose, Email: derek.grose@ggc.scot.nhs.uk.
Allan James, Email: allan.james@ggc.scot.nhs.uk.
Mohammed Rizwanullah, Email: mohammed.rizwanullah@ggc.scot.nhs.uk.
Claire Paterson, Email: claire.paterson2@ggc.scot.nhs.uk.
John Foster, Email: john.foster@glasgow.ac.uk.
Acknowledgements
The authors would like to express their gratitude to the Beatson radiotherapy and diagnostic radiography staff and to Mr James Paul, Head of Biostatistics at the Clinical Trials Unit, Beatson West of Scotland Cancer Centre. We would also like to acknowledge financial support from the NHS Learning and Education and The Beatson Oncology Centre Fund.
References
- Staffurth JN. A review of clinical evidence for intensity-modulated radiotherapy. Clin Oncol. 2010;22:643–657. doi: 10.1016/j.clon.2010.06.013. [DOI] [PubMed] [Google Scholar]
- Lam P, Au-Yeung KM, Cheng PW, Wei WI, Yuen AP, Trendell-Smith N, Li JH, Li R. Correlating MRI and histologic tumor thickness in the assessment of oral tongue cancer. Am J Roentgenol. 2004;182:803–808. doi: 10.2214/ajr.182.3.1820803. [DOI] [PubMed] [Google Scholar]
- Tetsumura A, Yoshino N, Amagasa T, Nagumo K, Okada N, Sasaki T. High-resolution magnetic resonance imaging of squamous cell carcinoma of the tongue: an in vitro study. Dentomaxillofac Radiol. 2001;30:14–21. doi: 10.1038/sj.dmfr.4600565. [DOI] [PubMed] [Google Scholar]
- Roland NJ, Paleri V. Head and Neck Cancer: Multidisciplinary Management Guidelines. 4. London: ENT UK; 2011. [Google Scholar]
- Chung NN, Ting LL, Hsu WC, Lui LT, Wang PM. Impact of magnetic resonance imaging versus CT on nasopharyngeal carcinoma: primary tumor target delineation for radiotherapy. Head Neck. 2004;26:241–246. doi: 10.1002/hed.10378. [DOI] [PubMed] [Google Scholar]
- Ahmed M, Schmidt M, Sohaib A, Kong C, Burke K, Richardson C, Usher M, Brennan S, Riddell A, Davies M, Newbold K, Harrington KJ, Nutting CM. The value of magnetic resonance imaging in target volume delineation of base of tongue tumours – a study using flexible surface coils. Radiother Oncol. 2010;94:161–167. doi: 10.1016/j.radonc.2009.12.021. [DOI] [PubMed] [Google Scholar]
- Newbold K, Partidge M, Cook G, Sohaib SA, Charles-Edwards E, Rhys-Evans P, Harrington K, Nutting C. Advanced imaging applied to radiotherapy planning in head and neck cancer: a clinical review. Br J Radiol. 2006;79:554–561. doi: 10.1259/bjr/48822193. [DOI] [PubMed] [Google Scholar]
- Sefrova J, Odrazka K, Paluska P, Belobradek Z, Brodak M, Dolezel M, Prosvic P, Macingova Z, Vosmik M, Hoffmann P, Louda M, Nejedla A. Magnetic resonance imaging in postprostatectomy radiotherapy planning. Int J Radiat Oncol Biol Phys. 2012;82:911–918. doi: 10.1016/j.ijrobp.2010.11.004. [DOI] [PubMed] [Google Scholar]
- Smith WL, Lewis C, Bauman G, Rodrigues G, D’Souza D, Ash R, Ho D, Venkatesan V, Downey D, Fenster A. Prostate volume contouring: a 3D analysis of segmentation using 3DTRUS, CT, and MR. Int J Radiat Oncol Biol Phys. 2007;67:1238–1247. doi: 10.1016/j.ijrobp.2006.11.027. [DOI] [PubMed] [Google Scholar]
- Khoo VS, Adams EJ, Saran F, Bedford JL, Perks JR, Warrington AP, Brada M. A comparison of clinical target volumes determined by CT and MRI for the radiotherapy planning of base of skull meningiomas. Int J Radiat Oncol Biol Phys. 2000;46:1309–1317. doi: 10.1016/S0360-3016(99)00541-6. [DOI] [PubMed] [Google Scholar]
- Prabhakara R, Haresh KP, Ganesh T, Joshi RC, Julka PK, Rath GK. Comparison of computed tomography and magnetic resonance based target volume in brain tumors. J Canc Res Ther. 2007;3:121–123. doi: 10.4103/0973-1482.34694. [DOI] [PubMed] [Google Scholar]
- Doran SJ, Charles-Edwards L, Reinsberg SA, Leach MO. A complete distortion correction for MR images: I. Gradient warp correction. Phys Med Biol. 2005;50:1343–1361. doi: 10.1088/0031-9155/50/7/001. [DOI] [PubMed] [Google Scholar]
- Khoo VS, Joon DL. New developments in MRI for target volume delineation in radiotherapy. Br J Radiol. 2006;79:S2–S15. doi: 10.1259/bjr/41321492. [DOI] [PubMed] [Google Scholar]
- Tamhane1 AA, Arfanakis K. Motion correction in PROPELLER and Turboprop-MRI. Magn Reson Med. 2009;62:174–182. doi: 10.1002/mrm.22004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fransson A, Andreo P, Pötter R. Aspects of MR image distortions in radiotherapy treatment planning. Strahlenther Onkol. 2001;177:59–73. doi: 10.1007/PL00002385. [DOI] [PubMed] [Google Scholar]
- Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys. 1996;23:815–850. doi: 10.1118/1.597854. [DOI] [PubMed] [Google Scholar]
- Hanvey S, Sadozye AH, McJury M, Glegg M, Foster J. The influence of MRI scan position on image registration accuracy, target delineation and calculated dose in prostatic radiotherapy. Br J Radiol. 2012;85:e1256–e1262. doi: 10.1259/bjr/26802977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hanvey S, Glegg M, Foster J. Magnetic resonance imaging for radiotherapy planning of brain cancer patients using immobilization and surface coils. Phys Med Biol. 2009;54:5381–5394. doi: 10.1088/0031-9155/54/18/002. [DOI] [PubMed] [Google Scholar]
- Kenneth U, Urie MM, Cherlow JM. Results of a multi-institutional benchmark test for cranial CT/MR image registration. Int J Radiat Oncol Biol Phys. 2010;77:1584–1589. doi: 10.1016/j.ijrobp.2009.10.017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zou KH, Warfield SK, Bharatha A, Tempany CM, Kaus MR, Haker SJ, Wells WM 3rd, Jolesz FA, Kinis R. Statistical validation of image segmentation quality based on a spatial overlap index. Acad Radiol. 2004;11:178–178. doi: 10.1016/S1076-6332(03)00671-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Grégoire V, Levendag P, Ang KK, Bernier J, Braaksma M, Budach V, Chao C, Coche E, Cooper JS, Cosnard G, Eisbruch A, El-Sayed S, Emami B, Grau C, Hamoir M, Lee N, Maingon P, Muller K, Reychler H. CT-based delineation of lymph node levels and related CTVs in the node-negative neck: DAHANCA, EORTC, GORTEC, NCIC, RTOG consensus guidelines. Radiother Oncol. 2003;69:227–236. doi: 10.1016/j.radonc.2003.09.011. [DOI] [PubMed] [Google Scholar]
- Yoon M, Park SY, Shin D, Lee SB, Pyo HR, Kim DY, Cho KH. A new homogeneity index based on statistical analysis of the dose–volume histogram. J Appl Clin Med Phys. 2007;8:9–17. doi: 10.1120/jacmp.v8i2.2390. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Prestwich RJD, Sykes J, Carey B, Sen M, Dyker KE, Scarsbrook AF. Improving target definition for head and neck radiotherapy: a place for magnetic resonance imaging and 18-fluoride fluorodeoxyglucose positron emission tomography? Clin Oncol. 2012;24:577–589. doi: 10.1016/j.clon.2012.04.002. [DOI] [PubMed] [Google Scholar]
- Rosenman JG, Miller EP, Tracton G, Cullip TJ. Image registration: an essential part of radiation therapy planning. Int J Radiat Oncol Biol Phys. 1998;40:197–205. doi: 10.1016/S0360-3016(97)00546-4. [DOI] [PubMed] [Google Scholar]
- Goitein M, Niemierko A. Intensity-modulated therapy and inhomogeneous dose to the tumor: a note of caution. Int J Radiat Oncol Biol Phys. 1996;36:519–522. doi: 10.1016/S0360-3016(96)00348-3. [DOI] [PubMed] [Google Scholar]