Skip to main content
The Journal of Clinical Investigation logoLink to The Journal of Clinical Investigation
. 1983 Nov;72(5):1563–1574. doi: 10.1172/JCI111115

Effects of energy delivery via a His bundle catheter during closed chest ablation of the atrioventricular conduction system.

J L Trantham, J J Gallagher, L D German, A Broughton, T Guarnieri, J Kasell
PMCID: PMC370444  PMID: 6605367

Abstract

In this paper we summarize our experience and report the characteristics of energy delivery in 23 patients who have undergone closed chest ablation of the normal atrioventricular (AV) conduction system for the treatment of refractory supraventricular arrhythmias. The induction of AV block was achieved by the synchronous delivery of electrical energy with a damped sinusoidal waveform utilizing a standard direct current defibrillator and a standard tripolar His bundle catheter. The procedure was well tolerated, though one patient experienced ventricular fibrillation, which was uneventfully converted with external paddles. Complete AV block was achieved in 20 of 23 patients and all were rendered arrhythmia free, though two still required antiarrhythmic drugs. A stable escape rhythm was seen in all patients with a cycle length of 1,294 +/- 243 ms. Creatine phosphokinase-MB was positive at low levels in 19 of 23 patients and cleared within 24 h. 99mTc pyrophosphate scans were faintly positive in only 2 of 22 patients. Left ventricular wall motion and ejection fractions were unchanged in 19 of 19 patients, two-dimensional echocardiography with microcavitation technique was unchanged in 12 of 12 patients, and a slight increase in pulmonary artery wedge pressure was seen in only 1 of 11 patients. Current, voltage, and their product (power) waveforms were recorded in 12 patients (12 recordings at a defibrillator setting of 200 J and 5 recordings at a defibrillator setting of 300 J) and revealed a complex voltage-current relationship due to changes occurring at the catheter electrode-tissue interface. At 200 J the peak values were 42.2 +/- 3.3 A, 2.16 +/- 0.11 kV, and 87.9 +/- 4.7 kW, while at 300 J the peak values were 58.2 +/- 2.8 A, 2.40 +/- 0.10 kV, and 134.4 +/- 6.7 kW, respectively. No instance of catheter disruption was seen, though "pitting" of the distal electrode (through which current passed) occurred in all but one catheter.

Full text

PDF
1563

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Babotai I., Brownlee R. Experimental atrioventricular block without thoracotomy: a new instrument. Cardiovasc Res. 1971 Jul;5(3):416–418. doi: 10.1093/cvr/5.3.416. [DOI] [PubMed] [Google Scholar]
  2. Brodman R., Fisher J. D. Evaluation of a catheter technique for ablation of accessory pathways near the coronary sinus using a canine model. Circulation. 1983 Apr;67(4):923–929. doi: 10.1161/01.cir.67.4.923. [DOI] [PubMed] [Google Scholar]
  3. Cole J. S., Wills R. E., Winterscheid L. C., Reichenbach D. D., Blackmon J. R. The Wolff-Parkinson-White syndrome: problems in evaluation and surgical therapy. Circulation. 1970 Jul;42(1):111–121. doi: 10.1161/01.cir.42.1.111. [DOI] [PubMed] [Google Scholar]
  4. Dreifus L. S., Nichols H., Morse D., Watanabe Y., Truex R. Control of recurrent tachycardia of Wolff-Parkinson-White syndrome by surgical ligature of the A-V bundle. Circulation. 1968 Dec;38(6):1030–1036. doi: 10.1161/01.cir.38.6.1030. [DOI] [PubMed] [Google Scholar]
  5. Dunaway M. C., King S. B., Jr, Hatcher C. R., Jr, Logue R. B. Disabling supraventricular tachycardia of Wolff-Parkinson-White syndrome (type A) controlled by surgical A-V block and a demand pacemaker after epicardial mapping studies. Circulation. 1972 Mar;45(3):522–528. doi: 10.1161/01.cir.45.3.522. [DOI] [PubMed] [Google Scholar]
  6. Dymond A. M. Characteristics of the metal-tissue interface of stimulation electrodes. IEEE Trans Biomed Eng. 1976 Jul;23(4):274–280. doi: 10.1109/tbme.1976.324585. [DOI] [PubMed] [Google Scholar]
  7. Ewy G. A., Fletcher R. D., Ewy M. D. Comparative analysis of direct current defibrillators. J Electrocardiol. 1972;5(4):349–354. doi: 10.1016/s0022-0736(72)80045-1. [DOI] [PubMed] [Google Scholar]
  8. Fisher V. J., Lee R. J., Christianson L. C., Kavaler F. Production of chronic atrioventricular block in dogs without thoracotomy. J Appl Physiol. 1966 May;21(3):1119–1121. doi: 10.1152/jappl.1966.21.3.1119. [DOI] [PubMed] [Google Scholar]
  9. Gallagher J. J., Svenson R. H., Kasell J. H., German L. D., Bardy G. H., Broughton A., Critelli G. Catheter technique for closed-chest ablation of the atrioventricular conduction system. N Engl J Med. 1982 Jan 28;306(4):194–200. doi: 10.1056/NEJM198201283060402. [DOI] [PubMed] [Google Scholar]
  10. Giannelli S., Jr, Ayres S. M., Gomprecht R. F., Conklin E. F., Kennedy R. J. Therapeutic surgical division of the human conduction system. JAMA. 1967 Jan 16;199(3):155–160. [PubMed] [Google Scholar]
  11. Gonzalez R., Scheinman M., Margaretten W., Rubinstein M. Closed-chest electrode-catheter technique for His bundle ablation in dogs. Am J Physiol. 1981 Aug;241(2):H283–H287. doi: 10.1152/ajpheart.1981.241.2.H283. [DOI] [PubMed] [Google Scholar]
  12. Harrison L., Gallagher J. J., Kasell J., Anderson R. H., Mikat E., Hackel D. B., Wallace A. G. Cryosurgical ablation of the A-V node-His bundle: a new method for producing A-V block. Circulation. 1977 Mar;55(3):463–470. doi: 10.1161/01.cir.55.3.463. [DOI] [PubMed] [Google Scholar]
  13. Klein G. J., Sealy W. C., Pritchett E. L., Harrison L., Hackel D. B., Davis D., Kasell J., Wallace A. G., Gallagher J. J. Cryosurgical ablation of the atrioventricular node-His bundle: long-term follow-up and properties of the junctional pacemaker. Circulation. 1980 Jan;61(1):8–15. doi: 10.1161/01.cir.61.1.8. [DOI] [PubMed] [Google Scholar]
  14. Latour H., Puech P., Grolleau R., Chaptal P. A., Dufoix R. Le traitement chirurgical des accès de tachycardie paroxystique graves du syndrome de Wolff-Parkinson-White et ses limites. Arch Mal Coeur Vaiss. 1970 Jul;63(7):977–989. [PubMed] [Google Scholar]
  15. RUSH S., ABILDSKOV J. A., McFEER Resistivity of body tissues at low frequencies. Circ Res. 1963 Jan;12:40–50. doi: 10.1161/01.res.12.1.40. [DOI] [PubMed] [Google Scholar]
  16. Randall O. S., Westerhof N., Van den Bos G. C., Sipkema P. Production of chronic heart block in closed-chest dogs: an improved technique. Am J Physiol. 1981 Aug;241(2):H279–H282. doi: 10.1152/ajpheart.1981.241.2.H279. [DOI] [PubMed] [Google Scholar]
  17. Sealy W. C., Anderson R. W., Gallagher J. J. Surgical treatment of supraventricular tachyarrhythmias. J Thorac Cardiovasc Surg. 1977 Apr;73(4):511–522. [PubMed] [Google Scholar]
  18. Sealy W. C., Gallagher J. J., Kasell J. His bundle interruption for control of inappropriate ventricular responses to atrial arrhythmias. Ann Thorac Surg. 1981 Nov;32(5):429–438. doi: 10.1016/s0003-4975(10)61774-2. [DOI] [PubMed] [Google Scholar]
  19. Sealy W. C., Hackel D. B., Seaber A. V. A study of methods for surgical interruption of the His bundle. J Thorac Cardiovasc Surg. 1977 Mar;73(3):424–430. [PubMed] [Google Scholar]
  20. Slama R., Blondeau P., Aigueperse J., Cachera J., Degeorges M., Albou E. Création chirurgicale d'un bloc auriculoventriculaire et implantation d'un stimulateur dans deux cas de troubles du rythme irréductibles. Arch Mal Coeur Vaiss. 1967 Mar;60(3):406–422. [PubMed] [Google Scholar]
  21. Turina M., Babotai I., Wegmann W. Production of chronic atrioventricular block in dogs without thoractomy. Cardiovasc Res. 1968 Oct;2(4):389–393. doi: 10.1093/cvr/2.4.389. [DOI] [PubMed] [Google Scholar]
  22. Vedel J., Frank R., Fontaine G., Fournial J. F., Grosgogeat Y. Bloc auriculo-venticulaire intra-hisien définitif induit au cours d'une exploration endoventriculaire droite. Arch Mal Coeur Vaiss. 1979 Jan;72(1):107–112. [PubMed] [Google Scholar]

Articles from Journal of Clinical Investigation are provided here courtesy of American Society for Clinical Investigation

RESOURCES